ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

Similar documents
ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

Plug-in modules for total pressure gauges and controllers TPG 300 and IMG 300

Vacuum measurement and control units

IONIVAC Transmitter ITR 90

Operating manual incl. Declaration of conformity

Single Point Flow Monitor SW118 SW119

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Product Data Sheet 4656 EZ

02/11/2015

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

Free Call: l

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Product Data Sheet 8506 VW-691

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

TELEDYNE HASTINGS INSTRUMENTS

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Process Transmitter RMA 422

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Solenoid valves VZWD, directly actuated

ODW-621. RS-232 Point-to-point applications

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Product Data Sheet 4656 ZW

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Absolute Encoders Multiturn

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

AC diagonal module Ø 200 mm

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Absolute encoders multiturn

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Fibre Optic Modem ODW-611

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Process transmitter RMA422

Linear flow controls VFC Linear flow controls with actuator IFC

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Solenoid valves VZWD, directly actuated

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Operating Instructions

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Operating instructions Electronic preset counter Type series 717

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Model KBF 115 Constant climate chambers with large temperature / humidity range

DMP 331i / DMP 333i LMP 331 i

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

SIMATRIX NEO V2 Modular Video Matrix

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Photoelectric Sensors E3F2

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Linear flow control with actuator IFC

Emergency lighting units EM powerled

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

PROPORTIONAL VALVES Sentronic plus

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Type SCH94FO. Type SCH94FO. Description

Mechanical flow switch for On/Off control

Modular pulse operated latching relay 16 A

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Selection matrix for electronic pressure switches

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Model KT 53 Cooling incubators with thermoelectric cooling

Fibre Optic Modem ODW-622

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Horn loudspeaker, Ex proof, short/long flare

Okta 1000, Roots pump without motor

Model KBF P 240 Humidity test chambers with ICH-compliant light source

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LAUREL ELECTRONICS, INC.

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

e-vap 3kW Evaporation Sources

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Bayard-Alpert Pirani Gauge

Transcription:

ITER Product Catalogue V20170405 Page 1 / 15

Content TPG 300 Passive Gauge Controller... 3 Pirani/Cold Cathode Measurement Board... 5 Interface and Relay Boards... 6 Pirani Gauge TPR 018... 7 Cold Cathode Gauge IKR 085... 9 Cables... 11 Cable Connectors Controller Side... 14 Cable Connectors Gauge Head Side... 14 Conversion Tables... 15 Page 2 / 15

TPG 300 Passive Gauge Controller Ideal controller for gauges under extreme conditions such as radiation and high temperature bake out. Modular plug-in circuit boards for measurement and communication. DIMENSIONS Page 3 / 15

SPECIFICATION Display Range 1000 1x10-11 mbar (depends on used gauge and boards) Measured value display 15 mm high numbers / 7 segment LED Unit of measure mbar, Torr, Pa Set point / relays 8 parameters - lower and upper threshold / 4 relays Error display / relay Red LED / 1 relay Measurement rate 100 Hz Display rate 5 Hz Temperature: Storage -40 to +65 C Operating +5 to +50 C Radiation resistant no Max. vertical magnetically field 21 mt (3 db), 15 mt (6 db) tbd Max. horizontal magnetically field 11 mt (3 db), 8 mt (6 db) tbd Main requirement: Voltage (range) 90 264 VAC ±10% Frequency (range) 47 63 Hz Power consumption <55 VA Overvoltage category II Relative humidity 80% at temperatures up to +31 C decreasing to 50% at +40 C Use Indoors only, height up to 2000 m Safety IEC384, class 1,VDE 0411, part 2.80 Filter time constant 16 ms, 160 ms (standard), 16.6 s Weight (without boards) 1.35 kg Controller Unit TPG 300 IO546900 Delivery time 2 weeks ITER Status Existing TPG300 is qualified, except for SIL-2 and magnetically shielding. Shielding tests ahead in May. New controller under and in concept phase (SIL-2 in clarification) ACCESSORIES Mains cable, German plug, 2.5 m 303-350 Mains cable, U.S. plug, 2.5 m 303-353 Mains cable, U.K. plug, 2.5 m 303-354 Mains cable, Japan 303-352 Mains cable, Korea plug, 2,5 m 303-351 Rack 19 for 3 TPG300 in IT491211 CABLES Please see page 11 and following Note: New controller expected to be available in 2019 Page 4 / 15

Pirani/Cold Cathode Measurement Board TPG 300 Measurement Unit Measurement and control down to 10-9 mbar SPECIFICATION Measurement Boards Number of measuring circuits Gauge Measurement range max. Measurement range min. Temperature: Operating Radiation resistant Max. applicable magnetic field Sensor cable length max. Reaction time of the output signal: Rise Weight CP 300 C9 Pirani / Cold Cathode 1 Pirani and 1 Cold Cathode ITER TPR018 and IKR085 1000 mbar 5x10-9 mbar 5 to 50 C no See TPG300 100 m 10 ms (Sudden pressure changes: Rise (10-90% from <10-9 to <10-3 mbar) 0.21 kg Measurement Board IO441000 Delivery time 2 weeks ITER Status Qualified ACCESSORIES Pirani connector Amphenol C91 Cold Cathode connector Lab plug 2mm LS205 Red isolation KT205 Black isolation KT205 IT4722796CA under IT47111152MA IT4711152NZ IT4711152NZ CABLES Please see page 11 and following Page 5 / 15

Interface and Relay Boards TPG 300 Measuring systems ProfiBus communication with control system and Hard wired set point relay outputs. SPECIFICATION Relay Connector Relay Numbers Max. applicable magnetic field Max. applicable magnetic field Relay: Switching voltage Relay: Switching current Relay: Switching power Relay: Resistance (with connector) Interface Interface: Connection IF 300 P D-sub 15 pin, male 4 relay for set point, 1 error relay all with changeover contacts, potential free See TPG300 See TPG300 30 V DC / 50 V AC 1.5 A 45W, 75VA 125 mohm ProfiBus-DP D-sub-connector, 9-pin, male Interface: Baud rates 1200, 2400, 4800, 9600, 19200 Interface: Data format Interface: Cable length max. Weight Interface and Relay Board Delivery time ITER Status ProfiBus protocols 1200 m 0.16 kg IO441395 8 weeks after final test In Qualification (magnetically shielding) ACCESSORIES Mating connector, D-Sub, male, 9 poles Mating connector, D-Sub, female, 15 poles IT941145 IT441129 Page 6 / 15

Pirani Gauge TPR 018 for TPG 300 measuring system Bake able and radiation resistant DIMENSIONS Page 7 / 15

SPECIFICATION TPR 018 TPR 018 Flange DN 16 ISO-KF DN 40 CF-F Display range Measurement range 5x10-4... 1000 mbar 1x10-2 100 mbar Operating temperature, high temperature sensor cable 0 to 120 C Operating temperature, standard sensor cable 0 to 80 C Bake out temperature (with high temperature cable or without cable) 250 C Mechanical Integrity 300 C * Radiation resistance Pressure deviation due to external magnetic field @ 10-2 mbar @ 1 mbar @ 10 2 mbar 1x10 7 Gy Up to 480 mt: < 5% Up to 300 mt: < 2.5% Always positive Accuracy: at room temp. and cable length <20m =±10% of reading in the range of 1x10-2 100 mbar Accuracy: at 0 +70 C and within the entire range of specified cable length =±20% of reading in the range of 1x10-2 100 mbar Accuracy: within the entire specified range of temperatures and cable length =±35% of reading in the range of 1x10-2 100 mbar Repeatability with air =±5% of reading in the range of 1x10-2 100 mbar Materials: Internal seal Al, Ni90 Overpressure Insulator Filament / holder Al 2 O 3, NiFeCo W/Ni Chamber wall, Housing feed through St. Steel 1.4435, 1.4306 9 bar (ltd. to inert gases) Protection category IP 40 Mounting orientation We recommend mounting the gauge aligned with the magnetic field. Weight 0.6 kg 0.85 kg Limited measurement and switching accuracy at pressures above 100 and below 10-3 mbar Gauge IOG15020 IOG15024 Delivery time 6 weeks 6 weeks ITER Status Qualified Qualified CABLES Please see page 11 and following no accidental cold cathode activation *Mechanical integrity vacuum tightness Page 8 / 15

Cold Cathode Gauge IKR 085 for TPG 300 measuring system Bake able and radiation resistant Magnetically fully shielded Lemo Triax P&P connector DIMENSIONS Page 9 / 15

SPECIFICATION IKR 085 IKR 085 Flange DN 40 ISO-KF DN 40 CF-F Display range Measurement range Operating temperature, with normal cable Operating temp., high temp. cable and Magnet 1x10-9 1x10-2 mbar 1 x 10-8 5 x10-3 mbar +5 C +80 C +5 C +250 C Bake out temperature with -Magnet 250 C Mechanical Integrity Radiation resistance 300 C* 1x10 7 Gy Accuracy in measurement range Approx. ± 30% Max. external magnetical field, axial direction (-3 db) Max. external magnetical field, axial direction (-6 db) Max. external magnetical field, radial direction (-3 db) Max. external magnetical field, radial direction (-6 db) Fully reversible recovery from external magnetic field, any orientation 180 mt (<10% deviation), 280 mt (< factor 2 dev.) 120 mt (<10% deviation), 200 mt (< factor 2 dev.) 150 mt (<10% deviation), 180 mt (< factor 2 dev.) 100 mt (<10% deviation), 120 mt (< factor 2 dev.) Tested up to 600 mt Materials: Vacuum connection St. steel (1.4306) Measuring chamber St. steel (1.4306) Feedthrough isolation Ceramic (Al 2 O 3 ) Internal seal Anode 316 L, Ag plating, Ni90 Ignition aid St. steel (1.4330) Magnet Sm Co 2:17 Electrical connection (Connector/Type) Overpressure Mo Triaxial connector female/ Lemo 9 bar, for inert gases and temp. <55 C only Protection category IP 40 Mounting orientation We recommend mounting the gauge aligned with the magnetic field. xxxxxxx Weight 0.6 kg 0.85 kg Gauge IOG18772 IOG18773 Delivery time 8 weeks after final test 8 weeks after final test ITER Status In Qualification In Qualification CABLES Please see page 13 only with SHV and Triaxial connector cable ITC240xxx to use. Tested at room temperature (~25 C) *Mechanical integrity vacuum tightness Page 10 / 15

Cables Connecting TPG300 with Gauges Pirani Cable TPR018 Max. bake out temperature 80 C 250 C Mechanical Integrity 80 C 250 C Radiation resistant to 1x10 3 Gy 1x10 6 Gy Max. measuring cable length Reduced flame propagation (according IEC 60332 or NF 32070 C1) Flame retardant (acc. IEC 60332-1 flame propagation on single cables) Low smoke (according to IEC 61034) Zero Halogen (according to IEC 60754-1) Non toxicity (according to IEC 60754-2) Max. measuring cable length 100 100 RoHS X X Material Amphenol C91 and Lemo (standard plugs on each side) Sensor cable TPR, 3 m, 80 C Sensor cable TPR, 10 m, 80 C Sensor cable TPR, 15 m, 80 C Sensor cable TPR, 20 m, 80 C Sensor cable TPR, 25 m, 80 C Sensor cable TPR, 30 m, 80 C Sensor cable TPR, 35 m, 80 C Sensor cable TPR, 40 m, 80 C Sensor cable TPR, 45 m, 80 C Sensor cable TPR, 50 m, 80 C Other cable length on request ITC548308 ITC548456 ITC548457 ITC548458 ITC548459 ITC548460 ITC548461 ITC548462 ITC548463 ITC548464 ITC154xxx High temperature sensor cable TPR, 3 m, 250 C High temperature sensor cable TPR, 5 m, 250 C High temperature sensor cable TPR, 10 m, 250 C High temperature sensor cable TPR, 15 m, 250 C High temperature sensor cable TPR, 20 m, 250 C High temperature sensor cable TPR, 25 m, 250 C High temperature sensor cable TPR, 30 m, 250 C High temperature sensor cable TPR, 35 m, 250 C High temperature sensor cable TPR, 40 m, 250 C High temperature sensor cable TPR, 45 m, 250 C High temperature sensor cable TPR, 50 m, 250 C Other cable length on request ITC548414 ITC548465 ITC448047 ITC448043 ITC448044 ITC120025 ITC120030 ITC120035 ITC120040 ITC120045 ITC120050 ITC120xxx Delivery time 4 to 6 weeks 4 to 6 weeks ITER Status none None Page 11 / 15

Cold Cathode Cable Max. bake out temperature 250 C Mechanical Integrity 250 C Radiation resistant to 1x10 6 Gy Max. measuring cable length 100 Reduced flame propagation (according IEC 60332 or NF 32070 C1) X Flame retardant (acc. IEC 60332-1 flame propagation on single cables) X Low smoke (according to IEC 61034) Zero Halogen (according to IEC 60754-1) X Non toxicity (according to IEC 60754-2) RoHS X Material Peek With SHV and Triax Lemo Sensor cable CC, 3 m Sensor cable CC, 5 m Sensor cable CC, 10 m Sensor cable CC, 15 m Sensor cable CC, 20 m Sensor cable CC, 25 m Sensor cable CC, 30 m Sensor cable CC, 35 m Sensor cable CC, 40 m Sensor cable CC, 45 m Sensor cable CC, 50 m Other cable length On request Delivery time ITER Status ITC230003 ITC230005 ITC230010 ITC230015 ITC230020 ITC230025 ITC230030 ITC230035 ITC230040 ITC230045 ITC230050 ITC230xxx under under Page 12 / 15

ITER irani Cable TPR018 ITER Pirani cable Max. bake out temperature 250 C 200 C Mechanical integrity 250 C 320 C ITER CC Cable Radiation resistant to 1x10 7 Gy 5x10 7 Gy Max. measuring cable length 100 100 Reduced flame propagation (according IEC 60332 or NF 32070 C1) X X Flame retardant (acc. IEC 60332-1 flame propagation on single cables) X X Low smoke (according to IEC61034) Zero Halogen (according to IEC 60754-1) X X Non toxicity (according to IEC 60754-2) X X RoHS X X Material PI Capton Special cable (Standard plugs controller side, gauge side P&P special) ITER Sensor cable TPR, 3 m, standard connector ITER Sensor cable TPR, 5 m, standard connector ITER Sensor cable TPR, 10 m, standard connector ITER Sensor cable TPR, 15 m, standard connector ITER Sensor cable TPR, 20 m, standard connector ITER Sensor cable TPR, 25 m, standard connector ITER Sensor cable TPR, 30 m, standard connector ITER Sensor cable TPR, 35 m, standard connector ITER Sensor cable TPR, 40 m, standard connector ITER Sensor cable TPR, 45 m, standard connector ITER Sensor cable TPR, 50 m, standard connector Other cable length On request X ITC130003 ITC130005 ITC130010 ITC130015 ITC130020 ITC130025 ITC130030 ITC130035 ITC130040 ITC130045 ITC130050 ITC130xxx ITER Cold Cathode Cable ITER Sensor cable CC, 3 m, SHV and triaxial connector ITER Sensor cable CC, 5 m, SHV and triaxial connector ITER Sensor cable CC, 10 m, SHV and triaxial connector ITER Sensor cable CC, 15 m, SHV and triaxial connector ITER Sensor cable CC, 20 m, SHV and triaxial connector ITER Sensor cable CC, 25 m, SHV and triaxial connector ITER Sensor cable CC, 30 m, SHV and triaxial connector ITER Sensor cable CC, 35 m, SHV and triaxial connector ITER Sensor cable CC, 40 m, SHV and triaxial connector ITER Sensor cable CC, 45 m, SHV and triaxial connector ITER Sensor cable CC, 50 m, SHV and triaxial connector Other cable length On request Delivery time ITER Status Under ITC240003 ITC240005 ITC240010 ITC240015 ITC240020 ITC240025 ITC240030 ITC240035 ITC240040 ITC240045 ITC240050 ITC240xxx Under Page 13 / 15

Cable Connectors Controller Side Cable Connectors Controller Side Pirani Connector at Controller - Amphenol C91 Pirani Connector at Controller Crimp contact C91 plug connector IT4722125 IT4722841 CC Plug at Controller 11_SHV-50- Peek CC Plug at Controller 11_SHV-50- Capton IT4726605 IT4728606 Delivery time ITER Status Under Under Cable Connectors Gauge Head Side Cable Connector Gauge Head Side Pirani Gauge Standard Plug Lemo 4.3 5.2 mm Pirani Gauge Standard Plug Lemo 5.3 6.2 mm IT4722062 IT4722063 CC Push Pull Triax Connector CC Push Pull Triax Connector New IT1001030 IT1001031 Delivery time ITER Status Under Under Page 14 / 15

Conversion Tables Mass kg lb slug oz cwt sh cwt kg 1 2.205 68.522 10-3 35.274 19.684 10-3 22.046 10-3 lb 0.454 1 31.081 10-3 16 8.929 10-3 10 10-3 slug 14.594 32.174 1 514.785 0.287 0.322 oz 28.349 10-3 62.5 10-3 1.943 10-3 1 0.588 10-3 0.625 10-3 cwt 50.802 112 3.481 1.792 10 3 1 1.12 sh cwt 45.359 100 3.108 1.6 10 3 0.893 1 Pressure N/m 2, Pa bar mbar Torr at lbf/in 2, psi N/m 2, Pa 1 10 10-6 10 10-3 7.5 10-3 9.869 10-6 0.145 10-3 bar 100 10 3 1 10 3 750.062 0.987 14.504 mbar 100 10-3 1 750.062 10-3 0.987 10-3 14.504 10-3 Torr 133.322 1.333 10-3 1.333 1 1.316 10-3 19.337 10-3 at 101.325 10 3 1.013 1.013 10 3 760 1 14.696 lbf/in 2, psi 6.895 10 3 68.948 10-3 68.948 51.715 68.046 10-3 1 Pressure Units used in the Vacuum Industry mbar Pascal Torr mmws psi inch of merc. mbar 1 100 750.062 10-3 10.2 14.504 10-3 2.95 10-2 Pascal 10 10-3 1 7.5 10-3 0.102 0.145 10-3 2.95 10-4 Torr 1.333 133.332 1 13.595 19.337 10-3 3.937 10-2 mmws 9.81 10-2 9.81 7.356 10-2 1 1.422 10-3 2.896 10-3 psi 68.948 6.895 10 3 51.715 703 1 2.036 inch of merc. 33.86 3.386 10 3 25.4 345 0.491 1 Dimension mm m inch ft mm 1 10-3 39.37 10-3 3.281 10-3 m 10 3 1 39.37 3.281 inch 25.4 25.4 10-3 1 8.333 10-2 ft 304.8 0.305 12 1 Temperature Kelvin Celsius Rankine Fahrenheit Kelvin 1 C+273.15 R 5/9 ( F+459.67) 5/9 Celsius K-273.15 1 ( R-491.69) 5/9 5/9 F-17.778 Rankine K 9/5 ( C 9/5)+491.69 1 F+459.67 Fahrenheit 9/5 K-459.67 9/5 ( C+17.778) R-459.67 1 Page 15 / 15