bio bas.1 USER S MANUAL

Similar documents
bio bas. 2 USER S MANUAL

CA-50 OPERATOR S MANUAL SYSMEX CORPORATION KOBE, JAPAN. Automated Blood Coagulation Analyzer

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

RQflex 10. Manual English

This document courtesy of:

WQ Series Water Quality Bench top Meters

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

VPM2. Operation Manual

SUMMARY OF THE METHOD SAMPLE PREPARATION

HulaMixer Sample Mixer

Quick Start Operating Instructions

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution

SediVue Dx * Urine Sediment Analyzer User Guide

LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Style 5S Clock / Timer

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Magnetic Stirrers Magnetic Stirr

Orbit TM DIGITAL SHAKERS

Sofia Strep A FIA Page 1 of 5

BLUNIK II ACCESSORIES SPORT DRIVE SPORT CALCULATOR... 49

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Vinmetrica SC-200 User Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

SECTOR Imager Performance Qualification Kit

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

DH551C/DH550C/DL550C Double Sided Display User Manual

VPM2. Operator's Manual

Blown Film Extrusion. Line Control. 5 Layers CD Series IBC Temperature USER MANUAL

CDV07. Analog video distribution amplifier(s)

ASSEMBLY AND CALIBRATION

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

HD-CM HORIZON DIGITAL CABLE METER

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Model KT 53 Cooling incubators with thermoelectric cooling

USER MANUAL Full HD Widescreen LED Monitor L215ADS

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

MT03A Electronic converter for flow rate transmitters

DEEPFRAME BASIC KIT- USER MANUAL VERSION ORIGINAL USER MANUAL

721N Spectrophotometer. Operating Manual

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

USER MANUAL Full HD Widescreen LED Monitor L236VA

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

Magnetic Field Generator 1000

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Part names (continued) Remote control

DCL9AW. User Manual. English

Operation/Users Manual

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

2013, 2014 Hewlett-Packard Development Company, L.P.

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

Total Chlorine Sensor

User's Guide to the PROLITE-30B

USER GUIDE. for. Automated purification of DNA from human or animal blood samples with

I.Safety Prevention Measures

ISC202 Quick Start Guide

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Electronic converter for level transmitters MT03L Instructions manual

Set Point Controller OC557. Operator s Manual

UNIGAS Hand-held combustion gas analyzer with 3 sensors

KNX Dimmer RGBW - User Manual

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Ambient Temperature...3 Electromagnetic Compliance...3

PSM-003. Micro Polarization Controller/Scrambler. User Guide

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

GLog Users Manual.

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

MULTIS L72. Operating instructions

Please read this manual before operating XB PRIME, and keep it for future reference. Referez-vous au mode d emploi avant d utilizer la XB PRIME.

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Noise Detector ND-1 Operating Manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Tube Rotator. User Guide. Version 1.2

multi-function meters

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

Fragment Analyzer Genomic DNA Analysis Kit

ZoneTouch V2 Zone Control System User Manual

Video Wall Display User s Manual

Digital differential Pressure switch Model DPS Instruction manual

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

17" & 19" Color TFT LCD Monitor

USER MANUAL. VP-424 HDMI to HDMI Scaler MODEL: P/N: Rev 2

CardioChek TM Analyzer

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

USER MANUEL. SNIPE 2 Ref R13

28 4K LED monitor. User Manual M284K

TABLE OF CONTENTS. Instructions:

Transcription:

Ctra. Santa Coloma, 7. E-17176, Sant Esteve de Bas. Girona. Spain. Tel. + 34 972.69.08.00-Fax. + 34.972.69.00.99 www.spinreact.com bio bas.1 USER S MANUAL

INDEX 1. INTRODUCTION 3 1.1 General 3 1.2 Theory of the instrument functioning 3 1.3 General description of the instrument 3 1.4 Functioning criteria and limitations 4 2. INSTALLATION 5 2.1 Recommendations on reception 5 2.2 Preparation before the installation 5 3. WORKING 6 3.1 Samples and reagents 6 3.2 Measurement 6 3.3 Switching on 7 3.4 Prothrombin Time 8 3.5 Activated Partial Thromboplastin Time 10 3.6 Fibrinogen 11 3.7 Time 13 4. SPECIAL UTILITIES 15 4.1 Prothrombin Time 15 4.2 Activated Partial Thromboplastin Time 17 4.3 Fibrinogen 18 4.4 Time 20 4.5 Language 21 4.6 By default 21 5. CONSUMABLES 23 6. MAINTENANCE 23 7. PROBLEMS AND SOLUTIONS 24 8. COMPLEMENTARY INFORMATION 24 2

1.INTRODUCTION 1.1 GENERAL: SPINREACT, bio bas.1 coagulometer is an instrument created to determinate the most important parameters run in plasma coagulation methods: Prothrombin Time or Quick Time (PT), Activated Partial Thromboplastin Time (APTT), Thrombin Time (TT), Fibrinogen Concentration (FB), and all coagulation methods whose principle is the determination of a clotting time. bio bas.1 stores the calibration curves for Prothrombin Time and Fibrinogen Concentration, which means no calculation is needed to be done by the user because it gives the result in time, activity, concentration, RATIO and INR. (different parameters, depending on the method). 1.2 THEORY OF THE INSTRUMENT FUNCTIONING: bio bas.1 has an optical measurement system which detects a sudden variation of the optical density when a clot is formed. The chronometer and the stirring system are activated by a sudden change of the optical density. This permits the initiation of the time measurement when the starter is added and to stop the measurement time at the moment the clot is formed. The continuous mixing guarantees a perfect homogenisation and makes possible the measurement of low concentrations of Fibrinogen by grouping the fibrin filaments in the centre of the optical path. The system has a programmable security time during which variations of the optical density, when the reagent and the plasma are still in the homogenisation phase, can not activate the detection cell. 1.3 GENERAL DESCRIPTION OF THE INSTRUMENT: Dimensions: 16.5 x 29 x 12.8 cm. Voltage and frequency: 220 V 50 Hz, 60 Hz Power data: 100 VA bio bas.1 has the following elements: Incubation zone for 10 cuvettes and one reagent. Reading zone. Keyboard. 3

Description of the keyboard functions: KEYS: VAL: used to display the result in Time, Percentage, Ratio, INR, concentration, : increases the sample identification number. : decreases the sample identification number. N: changes the method. Y: changes the method. OK: validation. RESET: reset the chronometer to zero. 1.4.FUNCTIONING CRITERIA AND LIMITATIONS The instrument has an accuracy of 1 tenth of a second. As it is a manual instrument, the influence of pipetting and the reagents conditions are very important, and to obtain a good repeatability on results, it is necessary to always follow the manufacturer s indications and the working method. 4

2. INSTALLATION bio bas. 1- User s manual 2.1. RECOMMENDATIONS ON RECEPTION: bio bas.1 should be stored in a dry place, no extreme temperatures and if it possible not directly under the sunlight. During the unpacking, the instrument and all accessories should be checked and in good conditions. The starter kit accessories are: 2 fuses of 2 amperes 1 plastic cover 1 user s manual 1 connection cable 1 black cap 50 coagulation cuvettes 50 stirring bars In case of any anomaly, please contact your distributor and fulfil the return tag included in the box. Store it in its box. It is recommended to keep it covered when no working to avoid dust to get into the reading zone. 2.2. PREPARATION BEFORE THE INSTALLATION: a) Conditions of the installation place: bio bas.1 should be installed in a place free of vibrations and without direct light, as the detection system is based on the variation of the absorbance of light and therefore all external interferences should be avoided. The surrounding temperature should be between 15 and 35 ºC without excessive humidity. b) Technical requirements: The connection to the electrical power should be made with the included connection cable and only if earth connection exists. 5

3. WORKING 3.1 SAMPLES AND REAGENTS: Samples: Citrate plasma is used, poor in platelets, obtained from venous puncture. The anticoagulant used should be Sodium Citrate 3.8%, in a ratio 1 part of citrate and 9 parts of blood. Centrifuge as soon as possible, for 10 at 3.000 r.p.m, in polystirene tubes. Quickly prepare the plasma, transfer it into clean and dry polystirene tubes, for better conservation and homogenisation. The maximum time recommended from extraction till measurement is 3-4 hours. Samples could be stored in the fridge, but never frozen. Reagents: The thermostatisation time should be well controlled if indicated in the packaging insert. Reagents must be all at room temperature and well homogenised before using them. Accessories: The plastic black cap is used to fix the pipette tip and maintain it in vertical position when adding the starter. It could not be necessary if pipetting is done in the middle of the reaction cuvette, in vertical position and without touching the reagent/plasma on the cuvette. 3.2. MEASUREMENT: Place the reaction cuvettes required for the samples to be run in the thermostat. Add a stirring bar into every cuvette and wait for the instrument to be at 37ºC (the asterisk indicates so). Dispense into the cuvettes the needed volume of reagent or sample. Look the specific packaging s. It is very important to avoid air bubbles formation, because they can stop the instrument before the clotting time. It is recommended to use a pipetting system that does not introduce bubbles. The cause is very often the pipetting pressure. That is why it is recommended to pipette AGAINST THE CUVETTES WALL or use a piston pipette when first reagent/plasma is added and PIPETTE IN A COMPLETE VERTICAL POSITION when adding the starter. Do not pipette with a disposable tip pipette on the cuvette bottom, because bubbles will be formed. In case any air bubble is formed, gently knock the cuvette bottom against any table or any flat surface, to make the bubbles to reach the surface of the liquid. When the thermostatisation time is finished, the cuvette is placed on the reading well. Be sure that it reaches well the bottom. Cover it with the cap, press RESET. The chronometer remains inactive for some seconds (delay time programmed, on the display it appears ---:-) and then it shows 000:0. At 6

this moment the reagent or plasma is added with a disposable tip pipette, leaving the liquid to get down with one blow and all the reaction starts at the same time. The addition MUST be done with a disposable tip pipette. DO NOT USE piston pipettes nor glass ones, because the liquid falls drop by drop, not with a blow, and all the reaction does not start at the same time. The addition is done introducing the tip of the pipette through the cap orifice and maintaining the pipette in vertical position, pipette for the dosage to fall in the central part of the cuvette (a pipette inclination would make the sample slide on the cuvette wall producing wrong results). The pipetting MUST NOT BE energetic nor extremely gently. If the cap is lost or it is not wanted to be used, do always pipette in the CENTRAL PART OF THE CUVETTE AND IN VERTICAL POSITION. When the reagent and the plasma are in contact a O.D. variation is produced, that automatically activates the digital chronometer and the magnetic mixer. When the clot starts to be formed, an O. D. variation is produced and stops the chronometer and the mixer. The clotting time is displayed. NOTE: Plasma thermostatisation: The reagents producers indicate the incubation time rules. This time must not be higher than the established one. If the plasma remains more than 5 minutes on the thermostat, an evaporation of the aqueous part takes place; often this phenomena can be observed on the cuvette wall and it makes the times to be shorter due to the plasma concentration. It is also important to obtain a perfect repeatability. All the plasmas must have the same incubation time, because if one plasma is thermostated at 3 and another one at 5, the results will be different. In case the working volume makes difficult to follow the incubation standardisation, it is possible to work with plasmas at room temperature (20 25 ºC), after taking the reference at the same temperature. 3.3. SWITCHING ON: Place the instrument on a stable place, away from direct light. Plug it and switch it on using the switch placed on the left rear side. 1 PT T: ---:-< The first number (1) indicates the sample identification. PT indicates the method T:---:- is the chronometer When the working temperature is reached, the final signal is an asterisk: 1 PT T: --- : -* 7

3.4 PROTHROMBIN TIME: bio bas. 1- User s manual Press N or Y keys till PT is displayed. 1 PT T: --- : -* Calibration: If calibration is wanted, press OK: CALIBRATE (Y/N) For an affirmative answer press Y. The first calibration point (100%) is displayed: % : 100 1 When pressing OK, the defined time is showed: TIME: (12.00) 1 The cursor is placed on the first number. With keys and it can be increased or decreased. The order is: blank space, decimal point, 0,1,.., 9. To go to next number press Y. When finished press OK. The second calibration point is displayed: % : 25 2 The cursor is placed in the tens of percentage. To modify it, use the arrows and. To go to units, press Y. To validate press OK. The programmed time is displayed: TIME: (23.00) 2 8

Modify it as done for the first point of calibration. Finally press OK. It goes to the main display of PT: 1 PT T: --- : -* Measuring: If the sample identification is wanted to be changed, press to increase it and to decrease it. Press RESET to activate the chronometer (If the incubation time was programmed, it will be displayed. To start the countdown press OK. At 20 left, a bip will sound. When the countdown will be finished, it will be set to zero). It is displayed: 1 PT T: 000 : 0* Dispense the starter reagent for the chronometer to start. When the clot is detected, the chronometer stops: 1 PT T: 12.9 * If result is wanted to be shown as percentage, ratio and INR, the VAL key should be pressed. The following displays will appear in a consecutive way: 1 PT % 80.3 * 1 PT R: 1.07 * 1 PT I: 1.16 * If a new sample is wanted to be run, press RESET and the chronometer will be activated. The sample identification is increased in one unit from the previous one. 2 PT T: 000 : 0* Once all readings are done, to exit from the PT program, press N and Y. 9

3.5 ACTIVATED PARTIAL THROMBOPLASTIN TIME: bio bas. 1- User s manual Press the keys N or Y till PTT is displayed: 1 PTT T: --- : -* Calibration If calibration is wanted, press OK: CALIBRATE (Y/N) When pressing Y it is displayed: REF. T.: (0) The cursor is placed on the first number. With keys and it can be increased or decreased. To go to next number (units) press Y. When finished press OK. It goes to the PTT main menu: 1 PTT T: --- : -* Measuring: If the sample identification is wanted to be changed, press to increase it and to decrease it. Press RESET to activate the chronometer. (If the incubation time was programmed, it will be displayed. To start the countdown press OK. At 20 left, a bip will sound. When the countdown will be finished, it will be set to zero). It is displayed: 1 PTT T: 000 : 0* Dispense the starter reagent for the chronometer to start. When the clot is detected, the chronometer stops: 1 PTT T: 30.4 * Pressing VAL, the result is shown as RATIO, if a reference time was introduced: 10

1 PTT R: 1.09 * If a new sample is wanted to be run, press RESET and the chronometer will be activated. The sample identification is increased in one unit from the previous one. 2 PTT T: 000 : 0* Once all readings are done, to exit from the PTT program, press N and Y. 3.6 FIBRINOGEN: Press the keys N or Y till Fibrinogen is displayed: 1 FB T: --- : -* Calibration If calibration is wanted, press OK: CALIBRATE (Y/N) When answering YES, it is displayed: CONC: (400) 1 The cursor is placed in the first number (hundreds). Using the keys and the value is increased or decreased. To go to the next number (tens) press Y. If it is needed, go to the third number. When finished press OK. The time is displayed: TIME: (8 ) If it is necessary to change the time, use the keys, and Y. To finish press OK. 11

The second point is displayed: bio bas. 1- User s manual CONC: (200) 2 It is modified like the first point. The time for the second calibration point is showed: TIME: (15 ) The time is modified as for the first point. Press OK to confirm it, and it goes to the measuring display. Measuring: If the sample identification is wanted to be changed, press to increase the value or to decrease it. Press RESET to activate the chronometer. (If the incubation time was programmed, it will be displayed. To start the countdown press OK. At 20 left, a bip will sound. When the countdown will be finished, it will be set to zero). It is displayed: 1 FB T: 000 : 0* Dispense the starter reagent for the chronometer to start. When the clot is detected, the chronometer stops: 1 FB T: 9.3 * When VAL is pressed, the result is shown as CONCENTRATION: 1 FB C: 337.3 * If a new sample is wanted to be run, press RESET and the chronometer will be activated. The sample identification is increased in one unit from the previous one. 2 FB T: 000 : 0* 12

Once all readings are done, to exit from the FB program, press N and Y. bio bas. 1- User s manual 3.7 TIME: Press the keys N or Y till Time is displayed: 1 T T: --- : -* Calibration: If calibration is wanted, press OK: CALIBRATE (Y/N) When pressing Y it is displayed: REF. T.: (0) The cursor is placed in the tens of percentage. To modify it, use the arrows and. To go to units, press Y. To validate press OK. The programmed time is displayed: It goes to the main display for Time: 1 T T: --- : -* Measuring: If the sample identification is wanted, press to increase it or to decrease it. Press RESET to activate the chronometer. (If the incubation time was programmed, it will be displayed. To start the countdown press OK. At 20 left, a bip will sound. When the countdown will be finished, it will be set to zero). It is displayed: 1 T T: 000 : 0* Dispense the starter reagent to activate the chronometer. When the clot is detected, the chronometer stops: 13

1 T T: 16.9 * If a reference time has been previously programmed, the ratio is displayed when pressing VAL: 1 T R: 0.84 * If a new sample is wanted to be run, press RESET and the chronometer will be activated. The sample identification is increased in one unit from the previous one. 2 T T: 000 : 0* Once all readings are done, to exit from the T program, press N and Y. 14

4. SPECIAL UTILITIES bio bas. 1- User s manual Pressing at the same time both arrows ( and ) from the main menu, it is possible to get into a technical menu that allows to change certain parameters of the instrument configuration. It is displayed: PT Pressing the key (Y ), the parameters change following this order (it is possible to go back pressing ( N)): PT PTT FB T LANGUAGE BY DEFAULT After BY DEFAULT, it goes to the main program. To choose any of the parameters, press OK when it is displayed. 4.1 PROTHROMBIN TIME: When PT is chosen, it is displayed: N. POINTS: (...) When pressing the keys ( and ), the number of points is increased or decreased. To accept press OK. The percentage of first point will appear: %: (100 ) 1 To modify the value use the vertical arrows ( and ), to change the number press the horizontal arrow 15

The time defined for the first point is displayed: T.: (12) 1 To modify the value use the vertical arrow ( and ), to change the number use the horizontal arrow The activity percentage for the second point is displayed: %: (25) 2 The defined time for the second point is displayed: T.: (24) 2 Then the ISI is requested. It is a value given by the reagents manufacturer and it is used to calculate the INR. To modify the value use the vertical arrows ( and ), to change the number use the horizontal arrow ISI: ( 2) The security time is requested. It is the time during which optical variations do not stop the instrument. By default is 5. SEF. T.: ( 5 ) 16

The delay time is requested. It is the time since RESET is pressed, after placing the cuvette in the reading position, till the chronometer is set to zero. By default is 3, but it could be longer if the reagent presents a high turbidity. DELAY: ( 3 ) At the end, the incubation time is requested. In case it is programmed a value different from zero, the chronometer will make a countdown to indicate the exact moment the starter should be added. The minimum value that may be introduced is 30 seconds. INCUB. T.: ( ) It goes to the initial display where PT is displayed. Pressing several times Y it goes to the main display. 4.2 ACTIVATED PARTIAL THROMBOPLASTIN TIME: From the PTT display, press OK to get into the configuration parameters to be modified. PTT Pressing OK again, the reference time is requested. It is optional and it is used to give the final result as a RATIO between the sample time and the time of a normal pool of plasmas. REF.T.: (0 ) 17

The security time is requested. It is the time during which optical variations do not stop the instrument. By default is 5. SEF. T.: ( 5 ) The delay time is requested. It is the time since RESET is pressed, after placing the cuvette in the reading position, till the chronometer is set to zero. By default is 3, but it could be longer if the reagent presents a high turbidity. DELAY: ( 3 ) At the end, the incubation time is requested. In case it is programmed a value different from zero, the chronometer will make a countdown to indicate the exact moment the starter should be added. The minimum value that may be introduced is 30 seconds. INCUB.T.: ( ) It goes to the initial display where PTT is displayed. Pressing several times Y it goes to the main display. 4.3 FIBRINOGEN: From the FB display, press OK to get into the configuration parameters to be modified. FB Then the number of points for the calibration is requested. 18

N. POINTS: (...) When pressing the vertical arrows ( and ), the number of points is increased or decreased. For acceptation, press OK. The concentration for the first point appears. CONC.: (400) 1 The time defined for the first point is displayed: TIME: (8) 1 The concentration for the second point is displayed: CONC.:(200) 2 The time defined for the second point is displayed: TIME: (5) 2 The security time is requested. It is the time during which optical variations do not stop the instrument. By default is 5. SAFE T.: ( 5 ) 19

The delay time is requested. It is the time since RESET is pressed, after placing the cuvette in the reading position, till the chronometer is set to zero. By default is 3, but it could be longer if the reagent presents a high turbidity. DELAY: ( 3 ) At the end, the incubation time is requested. In case it is programmed a value different from zero, the chronometer will make a countdown to indicate the exact moment the starter should be added. The minimum value that may be introduced is 30 seconds. INCUB.T.: ( ) It goes to the initial display where FB is displayed. Pressing several times Y it goes to the main display. 4.4 TIME: From the T display, press OK to get into the configuration parameters to be modified. T Pressing OK again, the reference time is requested. It is optional and it is used to present the final result as a RATIO between the sample time and the time of a normal pool of plasmas. REF. T. : (0) 20

The security time is requested. It is the time during which optical variations do not stop the instrument. By default is 5. SAFE T.: ( 5 ) The delay time is requested. It is the time since RESET is pressed, after placing the cuvette in the reading position, till the chronometer is set to zero. By default is 3, but it could be longer if the reagent presents a high turbidity. DELAY: ( 3 ) At the end, the incubation time is requested. In case it is programmed a value different from zero, the chronometer will make a countdown to indicate the exact moment the starter should be added. The minimum value that may be introduced is 30 seconds. INCUB.T.: ( ) It goes to the initial display where T is displayed. Pressing several times Y it goes to the main display. 4.5 LANGUAGE: It is displayed: LANGUAGE 21

When pressing OK the Spanish option appears: SPANISH To see the other options press Y. The different options are displayed: ENGLISH FRENCH Press OK to accept the wanted option. When pressing Y again, it goes to the main display. 4.6 BY DEFAULT: Pressing OK to this option, all introduced parameters will be removed and the original values for calibrations, reference times, incubation times, etc, will be re-installed. BY DEFAULT 22

5. CONSUMABLES: bio bas.1only requires the reagents and samples needed to run the tests and the accessories to take the samples, dilute them and make the reading. Reagents: P.T.: Calcium Thromboplastin, physiological saline solution and control plasma. P.T.T.: activator (cephaline-kaolin, ellagic acid, etc...), Calcium Chloride, physiological saline solution and control plasma. Fibrinogen: Thrombine reagent, buffer and calibrator. Accessories: Automatic micropipettes: to take the required volume of sample and reagents for every method. Cuvettes: to read the reaction. Ref FC 5200007 Magnetic stirrers: to homogenise the solution. Ref. FC 5200008 6. MAINTENANCE: A. Preventive maintenance: See table enclosed. B. Cleaning instructions: When the instrument does not work, should be protected with the plastic cover to avoid dust, specially in the reading zone. The a.m. cover should be placed some minutes after switching the instrument off. Be aware to not pipette any product in the instrument if the cuvette is not placed in the reading zone. C. Recommended spare parts: It is recommended to have a couple of fuses. 23

7 PROBLEMS AND SOLUTIONS: PROBLEMS POSSIBLE CAUSES SOLUTIONS Time obtained too short Air bubbles in the cuvette Eliminate the air bubbles Clot not detected No magnetic stirrer placed No reagent added No sample added RESET not pressed Add the component missing Press RESET It does not repeat Pipetting problems Review the method and the Chronometer starts when placing the cuvette in the reading position The specified way of work was not followed material used for pipetting Press RESET again The chronometer does not start RESET was not pressed before adding the starter Repeat the sample 8. COMPLEMENTARY INFORMATION 8.1 WARRANTY: bio bas.1 has one year warranty, excluding all damages done by a bad use of the instrument. 8.2 PC CONNECTION: bio bas.1 has a RS 232 exit to be connected to a PC. 8.3 ASSISTANCE: Contact your local supplier. 24

NOTES: 25

MAINTENANCE MANUAL Period month: Year: LABORATORY DAILY CONTROL Read a control. INSTRUMENT: bio bas.1 Nº: INSTALLED: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 MONTHLY CONTROL Read a high control. Read a low control. ANNUAL CONTROL Clean the optical group. Read a high control. Read a low control. Operator TAS NOTES