Ghielmetti Connecting System

Similar documents
ASF 1x32 AV 3/1 xxx Blueline ASF 1x32 AV 3/1 xxx Light ** ASF 1x24 AV 3/1 xx Econom

BNC-Panel-16-TTL User Manual

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

INSTRUCTION MANUAL NPPA-TT-S PATCH PANEL Easy Patch 96 Bantam (TT) Jacks, Solder lugs

HighBand 25. TrueNet Category 6 Solutions

Introduction. Audio Normalling

NewScope-7A Operating Manual

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

randomrhythm Bedienungsanleitung User Guide

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

The Audio Mixer from Switzerland. User Manual. Ab Seriennummer MI

DIN Connectors DIN06 E-03

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

SPECIAL SPECIFICATION 6686 BSIF CCTV Central Equipment

Medium Box for Cable Termination

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Class E A / Cat.6A Screened Coupler

TeamWork Installation Guide

SOURCE COMMANDER MSS433 A/V SELECTOR OWNER S MANUAL INSTALLATION GUIDE

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

TeamWork Kits Installation Guide

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

High-Performance Patching Systems

COMBINATION UNITS MARCH 2018

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity


Volition TM RJ45 K5e Jacks

INSTALLATION INSTRUCTIONS MO023A

Multi-Key v2.4 Multi-Function Amplifier Keying Interface

3M Distribution Box (DDB)

CYBER PAK. User Instructions.

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

VITEK VTM-TLM191 VTM-TLM240

CONNECTIVITY. The ultimate in cable performance

MRX1 1. Getting to know your MRX1 wireless controller

ROSIE Limited Warranty Installation

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

2002 Martin Professional A/S, Denmark.

Ribbon Cable connector Compliant with MIL Standard

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last.

VIDEO DOOR PHONE CAV-51M

Electrical 25 C Operating Temperature 0 C to +70 C TX RX L/R. RJ45 Durability Testing Rating

Limited WARRANTY: Make Noise implies and accepts no responsibility for harm to person or apparatus caused through operation of this product.

Connection Guide of the MOTOTRBO radio to the radioserver as a control station

RCA Epitome Audio Connectors (Good) Quantities of 10 each. These (Good) connectors appear in kit only.

Ribbon Cable connector Compliant with MIL Standard

SECTION COMMUNICATIONS HORIZONTAL CABLING

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

Jinyoung Contech Co., Ltd.

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Connectivity accessories by Nestor Cables

MIXING CONSOLE. Owner s Manual. Keep This Manual For Future Reference.

MAXX BOX. MX102/202 Series. MAXX Box

Colour Control48 Order Code: Control48

IP-LINX. Installation Guide

Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

NewTek SX-SDI Serial Digital Switcher INSTALLATION

User's Manual. Multi-Function ALTO PATCH LTO R. Version 2.0 August 2002 English

VMA ACTIVE MATRIX TFT COLOR LCD MONITOR OWNER S MANUAL INSTALLATION GUIDE

Video Patching Systems ProPatch Miniature (PPM) Series

C Connectors. Automatic Connector. Introduction. Contents. C Interface Options. 631/ FAX 631/

CATEGORY 6 CABLING SOLUTIONS

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

QUICK PATCH Coaxial Patch Panels

Summit Audio Model TLA-50 Tube Leveling Amplifier

DIN EUROCARD CONNECTORS

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

1. SAFETY & WARRANTY 2 2. WHAT IS CGM 3 3. SYSTEM SETUP (LINKING) Master to Group(s) Group to Channel(s) 3 4. CONNECT THE POWER 4

M-16DX 16-Channel Digital Mixer

DATA SHEET. DisplayPort1.2 to HDMI 2.0 Converting Active Optical Cable, DHFC-200D. Contents

ELECTRONIC CONNECTOR ASSEMBLY TRAINING CERTIFICATION EXAM (DVD-62C) v.1

MCM-20.4 PRELIMINARY USER GUIDE v1.1

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Technical Specifications

HDMI Cross Converter

INSTALLATION MANUAL FOR THE TIMING LIGHT

Unipole and Multipole Connectors

Video Door Entry System Kits 2 Wires Installation

Connecting cables NEBS, for sensors

IP-LINX Fiber :: X-XXXX

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

HI-DEX PRODUCT SET DATASHEET

20/20 -a phono preamplification instrument by Sutherland Engineering

0.4 mm Pitch, Horizontal mating, Board- to-fine Coaxial Cable Connectors

Everybody has seen Telechron clocks and even. US Navy Warren Telechron Clock System. by Robert Simon (CA)

Type "N" Connectors. Type "N" Interface Dimensions

MUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

MPO Technology Connectivity & Application

CATEGORY 5e CABLING SOLUTIONS

Connecting cables for valve terminals, M9x0.5 Type codes

Transcription:

Signal layer 1 (input) Contact pin gold plated insertion force 4.5 N Ghielmetti Connecting System Since many years already Ghielmetti products are used in radio and T stations, sound studios, theatres as well as in data and signal networks. Hereafter the advantages of Ghielmetti Panels - High durability and reliability - No moving parts, wearless - Self cleaning at each insertion withdrawal operation - Gold plated double contact system - nalog and digital application, ES/EBU - 3 pole signal lead, ground is activated - 2 pole switching, to prevent ground loops - Optional: High Performance with integrated channel shielding - 2 years guarantee Functionality Basis of the Ghielmetti Systems are alloyed beryllium bronze ribbons, bent and gold plated. These metal ribbons are inserted in patented plastic vats, 2 layers each compose together with front and rear plate a patch panel. To each wire is dedicated a pair of contact ribbons. s shown in the drawing, these ribbons run in the 2nd layers vertically. The connection is made by contact pins, which are inserted in the front resp. rear side. lso the contact pins are gold plated. Because of the bending the ribbons are compressed outwards by the contact pins. Thus ensures a absolutely safe and electrical clean connection. Due to the gold plating the surface is so smooth, that galvanic relevant humidity cannot affect the contacting. Dust and other impureness are wiped away during the insertion withdrawal operation, the system is self cleaning. Thanks to this functional principle the mentioned advantages result against the common jack fields actually available on the market. cut Beryllium bronce ribbons double contact system gold plated Signal layer 2 (output) Front view 1st layer cut Coding hole for reverse polarity protection of the pach cord cut B Top view plastic wat 1st layer plastic wat rear panel Gold plated ribbons 1st layer Gold plated ribbons

udio @ ideo @ Data Communications 1. Normal Patch Panel SF- For incoming and outgoing lines, which can be ranged on the patch panel by patching operations. s shown on section drawing B, the contacts of the patchcord reach only the 1 st layer. On normal patch panels the 2 nd layer is not populated, and therefore inactive. Cut Patch Cord udio connection Contact ribbon Cut contact ribbon 1 st layer 2. Normal Patch Panel with parallel tap: SF-P The functionality corresponds to the normal patch panel, though for incoming resp. outgoing signals 2 parallel connections are available for patch lines. Cut Patch Cord udio connection Contact ribbon Cut contact ribbon 1 st layer 3. Connecting Patch Panel SF- udio connection IN On the connecting patch panels incoming signals are on the top row, and outgoing signals on the buttom row. connection between incoming and outgoing lines can be realised on 2 ways. s shown on the section drawing, the signal of the outgoing line is on the 2 nd layer. Cut Normalling plug The input is on layer 1 same as with the normal patch panel. The direct connection between in- and output is made with a 3 pole normalling plug. The pins of the normalling plug are twice as long as those on the patchcord. This way 1 st layer is connected to 2 nd layer. Cut contact ribbon 1 st layer udio connection OUT Naturally the patching operations on the first layer are also possible as shown on the drawing. Patch Cord udio connection IN udio connection OUT 2/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14

udio @ ideo @ Data Communications Patch and connecting functions with Ghielmetti Patch Bays Single access point Double access point Parallel contact P Single access point Single access point ccess point to incoming line Connecting point incoming-outgoing line ccess point to outgoing line Double access point to incoming line Parallel contact to incoming line Connecting point incoming-outgoing line ccess point to outgoing line P ccess point to incoming line Connecting point incoming-outgoing line ccess point to outgoing line ccess point to outgoing line 1 Connecting point incoming-outgoing line 1 1 ccess point to incoming line Connecting point incoming-outgoing line 2 ccess point to outgoing line 2 2 3/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14

udio @ ideo @ Data Communications Source Network Electronic Routing Electronic Mixing Normalling at this point results in mixing of two source signals! NOTE: with digital signals this may result in an undefined destination signal. For rerouting, distributing No parallel connecting of two signals is available Destination Network 4/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14

udio @ ideo @ Data Communications Pin layout GHIELMETTI Patch Panels Back view G - + G - + G - + G - + G - + G - + G - + G - + Front view a b G a b G a b G a b G Ghielmetti Patch Panel front view GHIELMETTI - STECKFELD (Front nsic ht/front iew) PTCH CORD MLE HOT (+ /a) FEMLE COLD (-/b) GND (G) FEMLE NC FX bushing chuck insert housing MLE NC MX 5/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14

udio @ ideo @ Data Communications The most sophisticated Patch and Connecting Systems The basic construction of all Ghielmetti patch panels results from a same effect: Self-cleaning multi-level gold plated contact system with a flexible bus structure Therefore the patch panels can be built and delivered in several different types. lso customized devices can be easily realized. The basic elements exist of: Normal contact ccess to this contact are made by a patch cord. Two contacts in parallel P ccess to this contacts are made by patch cords. Connecting contact Connection is made by a connecting plug. unplugged, the connection is separated. NOTE: The pins of the connecting plugs and the pins of the patch cord connectors have different lengths. Therefore there is no direct connection when the patch cord is inserted into the connecting contact. On the other hand, there is a direct connection between the incoming and outgoing line when a connecting plug is inserted. Connecting and switching functions Standard pin out: a / + b / - shield locking pin (not used) 6/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14

udio @ ideo @ Data Communications Ghielmetti G Switzerland, Headquarter Tel: +41 32 671 13 13 Fax: +41 32 671 13 14 info@ghielmetti.ch www.ghielmetti.ch O:\Marketing\Datenblätter\GHIELMETTI Documentation\GHIELMETTI Documentations - english\dokumentationen e - Originale!\ghielmetti_interconnecting_system.doc - 02.02.16 7/7 GHIELMETTI G, Industriestrasse 6, CH-4562 Biberist, Schweiz - www.ghielmetti.ch - info@ghielmetti.ch - Tel.: +41 32 671 13 13 - Fax.: +41 32 671 13 14