Eddy Current Probe System

Similar documents
DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

IEPE Premium Accelerometer, Top Connector

IEPE Premium Accelerometer, Side Connector

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

MODEL HS35 DRAWWORKS OPTICAL ENCODER

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

3500/42M Proximitor*/Seismic Monitor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI3-EG08K-Y1-H1341

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

EXPlora. Introduction

Quality products from a single source

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Type SCH94FO. Type SCH94FO. Description

3500/72M Rod Position Monitor

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Gear Pump Units For single-line centralized lubrication systems

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Absolute Rotary Encoder E6CP

Model Number Structure

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

DMP 331i / DMP 333i LMP 331 i

Connecting cables for valves, round plug connectors Product range overview

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

3500/42E Vibration Monitor

AGS Low profile capacitive air gap measuring sensor for rotating machines

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Pressure transmitter For applications in hazardous areas Model IS-3

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Photoelectric Sensors E3F2

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3500/42M Proximitor * /Seismic Monitor Bently Nevada* Asset Condition Monitoring

RSCC. Load cells. Special features. Data sheet

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Panel-Mounted Thermostat

Quality products from a single source

Process transmitter RMA422

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Surface Mount Multilayer Ceramic Capacitors for RF Power Applications

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Level Measurement Point level measurement - RF Capacitance switches

02/11/2015

Linear encoders without bearings incremental System for linear motion feedback

Micro-Machined Silicon Transducers

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Absolute Encoders Multiturn

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Colour Explosion Proof Video Camera USER MANUAL VID-C

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Application Note Using Buffered Outputs and Patch Panels with the SETPOINT Machinery Protection System

RMA42. Technical Information

Process Transmitter RMA 422

Product Data Sheet 4650 N-465

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Product Data Sheet 4656 EZ

Magnetic Sensor - Incremental EHP

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Product Data Sheet 4656 ZW

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

SUHNER QMA SUBMINIATURE CONNECTORS

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Speed sensor MiniCoder GEL 2471

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

AMERICAN NATIONAL STANDARD

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

Bimetal Temperature Switch

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Product Data Sheet 8506 VW-691

3 Cleaning. 4 Technical data

Capacitance Level Measurement Electronic insert FEC 12

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Type Contact form Model

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Transcription:

CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm

Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used for measuring Shaft Vibration, Axial Position, Rotating Speed and Phase from small rotating machinery to large critical machinery. The CMSS 785 can be used in conjunction with the SKF On-line systems (IMx) in the following, typical industries: Petroleum reineries Petrochemical plants Power generation plants Common applications for machinery protection include Turbines and Compressors. Features Suitable for various applications: shaft vibration, axial position, rotating speed and phase mark of critical rotating machinery Environmental friendly design: lead-free soldering, RoHS compliance and small footprint Flexible mounting options: DIN-rail adaptor or 8-screw plate adaptor API standard 670 (5th Edition) compliant Intrinsically safe (CSA & ATEX) CE compliant The eddy probe is used to measure radial or axial shaft motion. It is mounted through or to the side of a bearing cap and observes the shaft s movement relative to its mounting position. An eddy probe system comprises a probe, a driver (oscillator/demodulator) and an optional extension cable. Eddy probe systems have excellent frequency response. They have no lower frequency limit and are used to measure shaft axial position as well as vibration. System speciications Standard calibration target: JIS SCM440 lat surface Measurement range: 0,25 to 2,25 mm (10 to 88.5 mil) from sensor tip Scale factor: 7,87 V/mm (200 mv/mil) Scale factor tolerance: ±5% for 5 m systems ± 6.5% for 9 m systems Linear characteristics: Within ±25 µm (±1 mil) for a straight line of 7,87 V/mm (200 mv/mil) for 5 m systems Within ±38 µm (±1.5 mil) for a straight line of 7,87 V/mm (200 mv/mil) for 9 m systems Linear range: 2 mm (78.7 mil) Frequency response: DC to 10 khz ( 3dB) Maximal output voltage: Approximately 23 V DC Sensor abnormal output voltage: Approximately 0,6 V DC (Sensor OPEN/ Sensor SHORT) Output impedance: 50 Ω, current 5 ma (maximum) Current consumption (10 kω load): maximum 15 ma Output noise: Approximately 15 mv pk-pk + power supply noise Sensor tip diameter: Approximately 5 mm and 8 mm System cable length: 5 m or 9 m Operational temperature Probe: 40 to +177 C ( 40 to +350 F) Range: Extension Cable: 40 to +177 C Driver: 40 to +80 C ( 40 to +176 F) Range of temperatures for agency approved systems (sensor, extension cable and driver) -EX for ATEX 35 to +80 C ( 31 to +176 F) -EX for CSA 20 to +85 C ( 4 to +185 F) Temperature characteristic Condition: Gap = 2 mm Target: JIS SCM440 0 to 80 C (at 20 C standard) Sensor: Less than ±3% of full scale Extension cable: Less than ±4% of full scale 0 to 60 C (at 20 C standard) Driver: Less than ±3% of full scale Loop: Less than ±6% of full scale Operational humidity range: 30 to 95% RH (non-condensing, non-submerged) (Probe only is 100% RH) Power: Within 24 V DC ±10% Dielectric strength of driver: Between each terminals and mounting plate: 1 ma or less at 500 V AC for one minute Insulation resistance of driver: Between each terminals and mounting plate: 100 MΩ or more at 500 V DC Terminal block: Spring lock terminal Applicable wire gauge: 0,2 to 1,5mm 2 Weight driver: Weight probe: Approximately 200 g (7 oz) CMSS 75/78, non armoured cable 1m: approximately 500g (17.6 oz) 2

Driver dimensions for DIN rail mount CMSS 785-11 and CMSS 785-21 CMSS 75 Probe CMSS 985 Extension cable CMSS 78 Probe CMSS 985 Extension cable System cable length, 5 m or 9 m CMSS 785 Driver CMSS 75 or CMSS 78 CMSS 985 extension cable System cable length probe CMSS 785 driver m 0,5 + 4,5 = 5 CMSS 785-11/-12 1,0 + 4,0 = 5 CMSS 785-11/-12 5,0 + = 5 CMSS 785-11/-12 0,5 + 8,5 = 9 CMSS 785-21/-22 1,0 + 8,0 = 9 CMSS 785-21/-22 9,0 + = 9 CMSS 785-21/-22 3

Driver dimensions 92 (3.6 ) 50,8 (2.0 ) 35 (1.4 ) 4x 4,5 (0.178 ) 31 (1.22 ) 50,8 (2.0 ) Sensor input connector Terminal block 29 (1.14 ) Sensor input connector 4x 4,5 (0.178 ) Terminal block 29 (1.14 ) 68 (2.7 ) 64 (2.52 ) Mounting plate 32 (1.26 ) 40 (1.57 ) 72 (2.8 ) 6 (0.24 ) Mounting plate 15 (0.6 ) 72 (2.83 ) 102 (4.0 ) 15 (0.6 ) 61 (2.4 ) Driver DIN Rail (35 mm) mount Screw mount Standard part ID Standard part ID CMSS 785-11 5 mm/ 8 mm, 5 m cable length, DIN Rail mount CMSS 785-12 5 mm/ 8 mm, 5 m cable length, screw mount CMSS 785-21 5 mm/ 8 mm, 9 m cable length, DIN Rail mount CMSS 785-22 5 mm/ 8 mm, 9 m cable length, screw mount Agency approved driver, add extension -EX -EX CSA C/US (Ex ia IIC T4) Canadian Standards Association, North America, and (dual certiication) ATEX (Ex ia IIC T4) ATmosphères Explosibles, Europe CMSS 785-11-EX CMSS 785-21-EX 5 mm/ 8 mm, agency approved, 5 m length, DIN Rail mount 5 mm/ 8 mm, agency approved, 9 m length, DIN Rail mount CMSS 785-12-EX CMSS 785-22-EX 5 mm/ 8 mm, agency approved, 5 m length, screw mount 5 mm/ 8 mm, agency approved, 9 m length, screw mount 4

Extension cables CMSS 985-L extension cable without armour Cable 3,6 (0.14 ) 6,8 (0.27 ) +20% L 0% CMSS 985-A extension cable with armour Cable Flexible armour 8,6 (0.34 ) 6,8 (0.27 ) L +50% 200% L +20% 0% Extension cable CMSS 985-L-40 CMSS 985-L-45 CMSS 985-L-80 CMSS 985-L-85 CMSS 985-A-40 CMSS 985-A-45 CMSS 985-A-80 CMSS 985-A-85 CMSS 985-L-40-EX CMSS 985-L-45-EX CMSS 985-L-80-EX CMSS 985-L-85-EX CMSS 985-A-40-EX CMSS 985-A-45-EX CMSS 985-A-80-EX CMSS 985-A-85-EX No armour, not agency approved, 4,0 m length No armour, not agency approved, 4,5 m length No armour, not agency approved, 8,0 m length No armour, not agency approved, 8,5 m length Armoured, not agency approved, 4,0 m length Armoured, not agency approved, 4,5 m length Armoured, not agency approved, 8,0 m length Armoured, not agency approved, 8,5 m length No armour, agency approved, 4,0 m length No armour, agency approved, 4,5 m length No armour, agency approved, 8,0 m length No armour, agency approved, 8,5 m length Armoured, agency approved, 4,0 m length Armoured, agency approved, 4,5 m length Armoured, agency approved, 8,0 m length Armoured, agency approved, 8,5 m length CMSS 78-L standard probe (without armour) Lock nut Sensor tip Threaded area Cable 3,6 8 (0.31 ) 3 (0.12 ) L 1 5 4,5 50 (1.97 ) L 2 0% L 3 CMSS 78-LU2-00-12-10 8 mm diameter probe, no armour, 3/8-24 UNF thread, unthreaded case length (L 1 ) 0 in, case length (L 2 ) 1.2 in, pigtail cable length (L 3 ) 1 m 5

CMSS 78-A standard probe (with armour) Sensor tip Lock nut Threaded area Flexible armour 8,6 (0.34 ) Cable 3,6 8 (0.31 ) 3 (0.12 ) L 1 5 (0.2 ) L 2 4,5 20 (0.8 ) 50 (1.97 ) +50 mm 100 mm L 3 0% L 3 CMSS 78-AM2-04-20-90 8 mm diameter probe, armoured, M10x1 thread, unthreaded case length (L 1 ) 40 mm, case length (L 2 ) 200 mm, pigtail cable length (L 3 ) 9,0 m Without luoro resin coating CMSS 78-R reverse mount Sensor tip Packing Threaded area Cable 3,6 8 (0.31 ) 5 (0.2 ) 30 (1.18 ) 0% L 3 CMSS 78-RM2-05-03-05 CMSS 78-RU2-02-12-90 8 mm probe, reverse mount, no armour, thread size M10x1, unthreaded length (L 1 ) 5 mm, case length (L 2 ) 30 mm (03 = 30 mm), cable length (L 3 ) 0,5 m 8 mm probe, reverse mount, no armour, thread size 3/8-24 UNF, unthreaded length (L 1 ) 0.2 in, case length (L 2 ) 1.2 in (12 = 1.2 in), cable length (L 3 ) 9,0 m CMSS 75-L standard probe (without armour) Sensor tip Lock nut Threaded area Cable 2,7 3 (0.12 ) L 1 5 (0.2 ) L 2 0% L 3 CMSS 75-LM1-06-25-10 5 mm, no armour, thread size M8x1, unthreaded length (L 1 ) 60 mm (06 = 60 mm), case length (L 2 ) 250 mm (25 = 250 mm), cable length (L 3 ) 1,0 m 6

CMSS 75-A armoured probe Sensor tip Lock nut Threaded area Flexible armour Cable 2,7 5 L 1 3 (0.12 ) (0.2 ) L 2 4,5 20 (0.8 ) 50 (1.97 ) +50 mm L 3 100 mm L 3 0% CMSS 75-AU1-02-10-05 5 mm, armour, thread size UNF 1/4-28, unthreaded length (L 1 ) 0.2 in, case length (L 2 ) 1.0 in, cable length (L 3 ) 0,5 m Ordering information CMSS 75 Eddy current probe Part number CMSS 75-ab1-cc-dd-ee (-EX) a L A Armour Standard (without armour) Armoured b1 Thread size M1 ISO M8x1 U1 UNF 1/4-28 CMSS 78 Eddy current probe Part number CMSS 78-ab2-cc-dd-ee (-EX) a Armour -EX Agency approved (optional) L Standard (without armour) CSA C/US (Ex ia IIC T4) A Armoured and ATEX (Ex ia IIC T4) b2 Thread size M2 ISO M10x1 ee Cable length (L 3 ) U2 UNF 3/8-24 05 0,5 m 10 1,0 m 50 5,0 m 90 9,0 m dd Case length (L 2 ) 10 mm increments from 20 to 250 mm, : 25 = 250 mm 0.1 in increments from 0.8 to 9.9 in, : 35 = 3.5 in cc Unthreaded length (L 1 ) 10 mm increments, from 0 to 230 mm, L 1 L 2 20 mm : 06 = 60 mm 0.1 in increments, from 0 to 9.2 in, L 1 L 2 0.7 in : 04 = 0.4 in 7

CMSS 78-R: 8 mm reverse mount probe Part number CMSS 78-Rb2-cc-dd-ee (-EX) b2 Thread size -EX Agency approved (optional) M2 ISO M10x1 CSA C/US (Ex ia IIC T4) U2 UNF 3/8-24 and ATEX (Ex ia IIC T4) cc Unthreaded length (L 1) 05 5 mm 02 0.2 inches dd Case length (L 2 ) 03 30 mm 12 1.2 inches ee Cable length (L 3 ) 05 0,5 m 10 1,0 m 50 5,0 m 90 9,0 m Installation notes 1 Calibration material Model CMSS 785 Transducer systems are calibrated for JIS SCM440 lat surface, target to exceed 15 mm (0.6 in) in diameter. (JIS SCM440 is an equivalent to AISI 4140). If the measured target is not JIS SCM440 lat surface, the system may have different characteristics. In this case, calibration with the connected equipment (e.g. monitor) is recommended for system veriication. 2 Shield wire connection To avoid noise being induced into the system, connect the shield wire of the signal cable (a 3-wire shielded cable between driver and monitor) to the driver s Shield terminal and monitor s COM terminal. 3 isolation The sensor and the extension cable connector shall be insulated with insulation sleeve (transparent shrink tube) or luoro resin insulation tape. A vinyl-insulating tape shall not be used when temperatures exceeding 80 C, to avoid possible trouble with wiring. The connector shall not be located in oil environment. Penetration of oil into the cable through the connector may cause the sensitivity to change, caused by change in the cable capacitance. 4 Megger test of signal cable If an insulation resistance test has been performed on the signal cable (3-wire shielded cable), be sure to discharge the electric load before connecting the cable to the driver to avoid damaging the driver. 5 Transducer system installation The driver is not resistant to rain water, so avoid out-door use and mount in appropriate enclosures. Water intrusion can lead to a change in sensitivity and insulation breakdown. 6 Scale factor error The scale factor error margin provided is based on test results performed in controlled environment. This regulated value may not be applicable to test results on-site. 7 Safety barrier When use of a zener barrier is speciied in intrinsically safe systems, the MTL 7796- safety barrier is recommended. The Linear range is reduced approximately 5% in intrinsic safety systems using barriers. Use of galvanic isolators does not affect range. skf.com skf.com/cm SKF is a registered trademark of the SKF Group. SKF Group 2017 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. PUB CM/P8 17104 EN October 2017