Select source Click the Bio Settings button to modify device settings. Select Fingers Use Ctrl+Left mouse button to select multiple fingers to scan.

Similar documents
Test Records. Scanning Test Records. This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information.

Update Records. Scanning Update Records

Biolock User/Programming Manual

Managing a Time Clock Station

(Handheld Interagency Identity Detection Equipment) Software Version User Guide. UG Rev 1.1

Scanning Entry Records Entry Records 1) Tools Menu Scanning Wizard 2) Using Scanner Hardware Contro 3) Entry Front Side 1

TIMECLOCK ENROLLMENT GUIDE (5000 SERIES)

Quick Start Guide. Multidimensional Imaging

How to Optimize Ad-Detective

Biometric Voting system

Raptor University. Raptor System Kiosk Training. Instructor: RAPTOR TECHNOLOGIES, LLC

Symphony Workflows. Barcoding and Maintaining Your Library s Collection

Quick Guide Book of Sending and receiving card

The DataView PowerPad III Control Panel

Using SignalTap II in the Quartus II Software

EndNote X8. Research Smarter. Online Guide. Don t forget to download the ipad App

Training Manual. for Scanner Identification System, Hardware and Training Preparation

Hardware Setup. If you have any further questions after checking this document, please contact

Procedures to Characterize Maury s Automatic Tuner Using ATS Software Version 5.1 or above

EndNote X6 Workshop Michigan State University Libraries

Import and quantification of a micro titer plate image

Exercise 5. Troubleshooting a QAM/DQAM Modem EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Signal flow tracing

Manual and Guidelines. For. Library Automation Software Version

R.E.A.D.S. INSTRUCTIONS FOR KINDLE ereaders

Processor time 9 Used memory 9. Lost video frames 11 Storage buffer 11 Received rate 11

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

Store Inventory Instruction Guide

The Kaffeine Handbook. Jürgen Kofler Christophe Thommeret Mauro Carvalho Chehab

Automate Pulse Set-Up Instructions

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

BioGraph Infiniti Physiology Suite

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Table of content. Table of content Introduction Concepts Hardware setup...4

Library Guide to EndNote Online

DektakXT Profilometer. Standard Operating Procedure

7) What do you mean it supports 'Cloud'? It can communicate with Workforce Central over the open internet or the "cloud"

Ydea-C5 System. Automatic Brightness Adjustment_DMX User Manual

ST9100C User Guide. Features

FOR WWW TEACUPSOFTWARE COM User Guide

Digital Video Recorder

Operating Instructions for Scanmark insight 4ES Scanner with QuickScore

This document describes the GUIs and menu operations of the self-service attendance terminal. Not all the devices have the function with.

2018 Quick Reference Guide

Using EndNote. Starting Guide

LCD-420SI. TimeIPS LCD Display w/speaker and Biometric Fingerprint Reader. Installation Guide

Supplemental Information

EndNote Web. Quick Reference Card THOMSON SCIENTIFIC

The Basics of EndNote. Endnote Training (Desktop Client Version) Brian Erb

Processing data with Mestrelab Mnova

Ultra 4K Tool Box. Version Release Note

EasyAir Philips Field Apps User Manual. May 2018

Figure 1. MFP-3D software tray

Experiment P32: Sound Waves (Sound Sensor)

Kiosk Overview Configuring the Kiosk in Links Setup & Registration Registering a Kiosk Sale Items Security...

RMS 8424S Quick Start

Setup Guide. EIZO Monitors. Rev. 1.4

Getting started with Spike Recorder on PC/Mac/Linux

A STUDY ON THE DEVELOPMENT OF THE DEDICATED OBU 1 FOR THE HANDICAPPED PERSONS USING HI-PASS 2 SYSTEM

Transmitter Interface Program

Part names (continued) Remote control

Quick Start Bruker Dimension Icon AFM

Procedures for conducting User QA on the scanner

Synergy SIS Attendance Administrator Guide

EndNote Tutorial Handout Table of Contents

What can EndNote do?

How-to Setup Motion Detection on a Dahua DVR/NVR

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

Basic Pattern Recognition with NI Vision

Scan Converter Quick Installation Guide

LedSet User s Manual V Official website: 1 /

Comparative Study on Fingerprint Recognition Systems Project BioFinger

MANAGERS REFERENCE GUIDE FOR

DIGITAL PORTABLE RECORDER TRAINING MANUAL FOR COURT REPORTING OFFICERs

EndNote for Windows. Take a class. Background. Getting Started. 1 of 17

Chapter 17: Online Scanning

Operation Procedure for Phillips XL30 ESEM

B2 Spice A/D Tutorial Author: B. Mealy revised: July 27, 2006

ECT 224: Digital Computer Fundamentals Digital Circuit Simulation & Timing Analysis

HV/PHA Adjustment (PB) Part

802DN Series A DeviceNet Limit Switch Parameter List

How to Insert Page Numbers in WORD

PYROPTIX TM IMAGE PROCESSING SOFTWARE

EDL8 Race Dash Manual Engine Management Systems

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

EndNote X6 with Word 2007

EndNote Workshop. King Abdulaziz University. Center for Teaching & Learning Development. Done by: Jamilah Al-Amri

Introduction to EndNote

Wetek OpenELEC TVHeadend Freesat Bouquet and XMLTV data

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Neck (BM4x12 4PCS) (ST4x14 4PCS) Power Cable

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Pre-processing of revolution speed data in ArtemiS SUITE 1

Revision Protocol Date Author Company Description 1.1 May 14, Seth LOUTH Revised for formatting

User s Guide W-E

EndNote X1 Workshop. 1. What s EndNote? 1. Your own database for references 2. A citation formatter 3. A search interface

A BEGINNER'S GUIDE TO ENDNOTE ONLINE

Microsoft Office Word 2016 for Mac

KNX Dimmer RGBW - User Manual

Scan Converter Installation Guide

Transcription:

1. Select Source for SC Biometrics Choose Select Source from the Image Menu. Select the desired image type to link to the SC Biometric image source. Select SC Biometrics from the Custom dropdown list. Select source Click the Bio Settings button to modify device settings. Select Fingers Use Ctrl+Left mouse button to select multiple fingers to scan.

Select multiple fingers, click More, the following dialog box is presented. These settings are only configured in combination with NEC enabled devices. 1.1.1 Scanner Select your device model from the drop down list. 1.1.2 Security Select the level of security. Low security will allow easy and quick scanning but there is a chance different fingers will give a positive match. If you select the maximum security the verification is more secure but sometimes it is difficult to enroll all fingers. It is best to start with a high level of security, in the case the finger enrollment causes errors you can step down a level on security. 1.1.3 Scans ScreenCheck advise to make at least two scans. If you do only one scan, there is a good chance that a finger is unsuccessfully enrolled. You can scan up to 10 fingers. To select multiple fingers hold down the <CTRL> button whilst clicking with the left mouse button on a finger.

2. Acquire SC Biometrics Select the correct image type such as the Finger Template window for example, and right click with your mouse then click Acquire. The SC Biometric Plug-in will initialize. After a short communication with the scanner, the SC Biometrics window will appear. Click Capture to begin scanning. Follow the instructions on the screen carefully and scan all required fingers indicated by the color GREEN. Place your finger on the scanner to acquire and image, the plug-in will capture a scan once the finger has been recognized by the reader.

When a finger is scanned successfully it will be displayed with a green checkmark above it. The red marker above will indicate a failure to read your finger and should be scanned again. Each finger scan is displayed separately. 2.1 Settings Click Settings to configure the following:

2.1.1 Scanner parameters Time out: Set the amount of seconds per session needed to capture. Once the time limit has been reached the session is disconnected. Brightness: Set the brightness for your images. Higher value means darker image. Default value is 100. Sensitivity: Set the sensitivity for the sensor on the reader. Value ranges from 0 to 7. A higher value means more sensitivity. Default value is 4. Detect Core: When enabled the reader will locate a unique reference point on the finger usually located in the central area of the fingerprint. By Default this feature is enabled. This setting should be enabled to obtain more accurate fingerprints the verification may fail if the image captured is not good enough. Enabling Detect Core ensures a more accurate fingerprint. 2.1.2 Matcher settings Security level (FAR): Set the level of security, this ranges from 1 to 7 being the most secure verification. FAR (False Acceptance Ratio) Refers to the percentage of acceptance by unregistered fingerprints. Fast mode: Set the speed in which identification takes place. Auto rotate: Rotate the template of a fingerprint enrolled 180 degrees. Select Save to transfer the scanned fingers to the database. The images and templates of captured fingers will be stored in one BLOB (Binary Large Object). Finger images can then be displayed on a badge. Finger images and templates can be stored in 2D Barcode, in a contact chip or in a Mifare chip.

Please note that the finger images in general are too big to store in a barcode or Mifare chip and is not commonly done unless requirements insist. After saving the biometrics data, you can begin finger verification to Verify Biometrics..

3. Verify Bio The option Verify Bio is only available when SC Biometrics has been installed, if SC Biometrics is not installed than Verify Bio will remain disabled. SC Biometrics can carry out verification matching a current taken scan with the saved characteristics of a scan in the database. This is useful to identify an existing person in the database or to verify scan is operating successfully. To begin a search, please select the Image Menu and then select Verify Bio. Present the indicated finger and lay it onto the surface of the scanner. The finger is scanned and matched to the current selected image in the database. If the verification was successful you will see the following dialog.

If the verification process is unsuccessful you will see the following dialog SC Biometrics Verify does not acquire an image. You must select Acquire to obtain an image. If multiple scans have been captured and you select Verify Bio, the same procedure is carried out but multiple verifications will take place.

4. Identify Bio To access select Identify Bio from the Image Menu or right click inside the Finger Template window with the right mouse button and select Identify Bio. Select this feature to search the database for an individual record based upon his/her fingerprint. Click Ok.

Present the indicated finger and lay it onto the surface of the scanner. The finger is scanned and matched to an existing fingerprint already tied to a record in the database. If the verification was successful you will see the record tagged in BadgeMaker.

If the identification process was unsuccessful and no existing record is identified the following dialog is presented. This feature is only available if Fingerprint templates already exist in the database. The Finger Template window must be active in order to select Identify Bio from the Image Menu.