Effects of ESD and Cleaning on SFP Fiber Optic Transceivers

Similar documents
Small Form-Factor Pluggable (SFP) Module Installation Guide

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

10Gbps SFP+ Optical Transceiver, 10km Reach

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

OptEnet OC48 Regenerator Module User Manual

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

MOST. Getting the. BMW Assist. Climate. Settings

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

Fiber Optic Meter Fiber Optic Source

Fibre Optic Modem ODW-622

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

SHF Communication Technologies AG,

3M Better Buried Compound Compression Closure System

SECTION 4 TABLE OF CONTENTS

Aerospace Fiber Optics

Service Call: Fiber Optic Installation and Repair

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

apple Service Source Apple Studio Display 17" LCD (ADC) Updated 6 Decenber Apple Computer, Inc. All rights reserved.

Water blocking tape. Locator ridge HPA-0486

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

WP36BHD T-1 (3mm) Blinking LED Lamp

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Product Operation Manual

AA3528VR4AS-W2 3.5 x 2.8 mm Surface Mount LED Lamp

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

Kingbright. L-7104YD-12V T-1 (3mm) Solid State Lamp DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

LITE-ON TECHNOLOGY CORPORATION

3M Cold Shrink Splice Kit QS-III 5515A

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Model OTDV Broadcast Transport Links OPERATING MANUAL

3M Fiber Optic Wall Mount Enclosure 8430 Series

T A S A 2 N B 1 F A H

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

3M Cold Shrink Splice Kit QS-III 5514A

Preventing Fieldbus Physical Layer Problems

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

MITSUBISHI ELECTRONICS AMERICA, INC.

Two (2) fibers Detachable DisplayPort 1.2 Extender. User s Manual for the DPFX-200-TR. Manual Contents

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

Jul03 Rev C EC

Operation Manual VMS 3.0 Video System

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Optical Design Manufacturing, Inc. Sprint 2.5. Alcatel-Lucent (ALU) Fiber Inspection and Testing Procedures. Technical Support Document

Monolith Turntable P/N User's Manual

DIAS power supply and DIC 221 fibre optic cable coupling module

Kramer Electronics, Ltd. USER MANUAL. Models: 622T, Dual Link DVI Optical Transmitter 622R, Dual Link DVI Optical Receiver

LONWORKS Fibre Optic Converter

USER MANUAL. CAMPLEX opticalcon

Fibre Optic Modem ODW-611

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

FOSC 450 C6 and D6 Closures

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

FiberLink 3500 Series Transceivers

Mar11 Rev E

OPTICA TECHNOLOGIES INCORPORATED and the OPTICA TECHNOLOGIES INCORPORATED logo are trademarks of Optica Technologies Incorporated.

LONWORKS Fibre Optic Router

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: 690T SDI Fiber Optic Transmitter 690R SDI Fiber Optic Receiver. P/N: Rev 2

ODW-621. RS-232 Point-to-point applications

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

3G/HD/SD-SDI Over Fiber Transmitter and Receiver Extender. User Manual L-1SDI-FE-3G-TX/RX

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

6 GHz to 26 GHz, GaAs MMIC Fundamental Mixer HMC773A

Fiber Meter. Specification & User Manual

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS Effective Date: 10/19/2012 LITE-ON DCC RELEASE

Fiber Optic. Foreword. Special Tips:

NHD YF-CTXI# TFT

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

FiberLink 7142 Series

Datasheet: MultiFiber Pro

Specific Lighting Product Data Sheet LTPL-U35UVC280GH LITE-ON DCC RELEASE

1.2 GHz GS7000 Node RF Split Upgrade Application Note

Light Source. Specification & User Manual

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Datasheet: MultiFiber Pro Update

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

THE GOLDMUND MIMESIS 36 CD TURNTABLE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Transcription:

Effects of ESD and Cleaning on SFP Fiber Optic Transceivers Field Service & GSC Training DOC1928793 MR Service Engineering Imagination at work

Overview Optical Modules or SFP (small form-factor pluggable) transceivers used in MR scanners are sensitive to ESD (electro static discharge). This training addresses the proper handling during installation and replacement, as well as the proper cleaning procedure to avoid intermittent signals, degraded signal power, and electrical overstress attributed to latent failures. Learning Objectives Upon completing this training, you will be able to: Define ESD Know SFP Module Failures, Effects, & Prevention Diagnose and Troubleshoot SFP Transceivers Use of SFP Cleaning Kit GEHC 5478006 Audience This course is required for all GEHC employees that handle fiber optic transceivers, used in MR scanner communication links. This includes, but not limited to, Design Engineers, Manufacturing Engineers, Production Associates, and Service Engineers. Module Length This module takes 15-20 minutes to complete. Course Completion You must complete the learning module and the assessment (80% or higher) to get credit for this course.

Contents Overview Lesson 1: What is ESD? Lesson 2: SFP Failure Modes, Effects, & Prevention Lesson 3: Diagnostics and Troubleshooting Lesson 4: SFP Cleaning Procedure 3

Lesson 1: What is ESD? Electro-Static Discharge (ESD) is defined as the rapid movement of electrical charges from one object to another. An object can become charged: When surfaces separate From friction; the movement of materials against surfaces (i.e. your shoe against the floor) ESD voltage levels are dependent on RH (relative humidity) Did you know? Note: GEHC SFP # 5183329-2 protected to 2kV, 5183329-3 upgraded to 8kV HBM 4

Sources of ESD Vinyl binders Equipment covers Plastic document holders/sheet protectors Post-It TM notes Plastic pens Bubble wrap Plastic housings on equipment Paper, schematics, etc. Personal items o Purses o Sweaters/jackets o Insulated lunch totes o Combs/brushes o Lotion bottles Plastic spray bottles 5

ESD Failures and Cost CATASTROPHIC FAILURE Device circuitry is permanently damaged An electronic device exposed to ESD no long work LATENT FAILURE Device is partially damaged, yet continues to function (i.e., pass tests) Product may experience a failure after it is placed into service COST TO GE HEALTHCARE Up to 10% Annual Revenue Field Repair & Part Replacement Labor & Transportation Customer Dissatisfaction 6

Lesson 2: SFP Module Failure Modes & Effects SFP (Small Factor Pluggable) Transceivers used in GE scanners suffer from link loss mechanisms that can be controlled: 1 SFP Junction loss Walkout (Input /Output connector seating) 2 Micro-Bend loss (i.e., Cable Damage due to Inadvertent Kinking / Pinching) 3 Macro-Bend loss (i.e., Bend Radius Less than 7.0 in. (17.78 cm for Gradient Fiber Cable) 4 SFP Lens Impurities (Dirt on Fiber Cable or Transceiver) 5 ESD that Exceeds the 8kV HBM Protection 4 Impurities 3 Macro Bend Loss 1 Junction Loss Input Signal Output Signal 2 Micro Bend Loss 5 ESD 7

Link Loss: Walkout Walkout is a common condition where the cable connector backs out of the transceiver. Prevention: SFP cables must be seated properly into the SFP transceiver When replacing the SFP, clean both the cable ends and the transceiver GEHC Fiber Optic Cleaning Kit 5478006 Insert cable by applying pressure to the black ring on the cable end using your finger nail - DOC1818501 To ensure a good connection, gently pull on the cable after insertion A loose fiber optic cable can lead to intermittent communication faults. 8

Link Loss: Micro / Macro Bend Micro-bend link loss occurs in fiber cable that has been crimped or pinched because fiber optic signal is scattered. Prevention: Do not allow cabinet covers or doors to crimp fiber optic cables Do not walk or roll equipment over the fiber Macro-bend link loss occurs in fiber cable that violates its minimum bend radius because light cannot bend sharp corners. Prevention: When routing cables, keep a minimum bend radius of > 7 inches (17.78cm) If SFP cable is crimped or draped over a cabinet, the link will be lost. 9

Link Loss: Lens Impurities Impurities left on the lens and cables limits light output, thus stressing the SFP module. Contamination accounts for significant power loss (2-6 db) that can create a link down hard system failure even though the transceiver is functional. Dirty Optics Clean Optics Prevention: When replacing the SFP, clean both the cable ends and the transceiver Service Note: DOC1818501 GEHC Fiber Optic Cleaning Kit (PN: 5478006) Never allow the end of the fiber optic cable to make contact with any surface, including direct contact with fingers (Dirty Optics shown above is the result of finger oil and dust deposits) Never clean the transceiver by blowing into the lens this will leave impurities (dust and moisture which will be very difficult to clean once the laser burns this into the lens Never use your shirt tail to clean the cable or transceiver only use nonwoven material to prevent scratching the lens, resulting in scattering the light signal. Clean fiber optic components are required for quality communication. 10

Link Loss: ESD ESD induces a latent effect called DLD (Dark Line defect) that reduces the light aperture of the lens, forces the laser driver to increase its Transmit Bias (TxBias) current, Results in electrical over stress. Think of this as a pebble that hits your windshield, the crack continues to grow, until your vision is impaired. Prevention: SFP is protected to 8kV. ESD can easily surpass this level in climates with low relative humidity. SFP ESD protection is reduced in MR scan room, due to strong B0 field. ESD strap is required at all times when handling the SFP fiber optic transceiver. Use Silver Static Shielding packaging when moving or transporting SFP modules Reference: O. Ueda, Reliability and Degradation of III-V Optical Devices (Artech House, Boston, 1996) ESD will deliver a latent effect to the SFP, not apparent at installation. 11

Lesson 3: Diagnostics and Troubleshooting DVMR Link Diagnostics displays the SFP system health parameters, indicating failure mode: Voltage Temperature TxBias Current TxPower RxPower Definite internal fault FE & PA instructed to replace unit 12

Diagnostics and Troubleshooting (continues) To troubleshoot the link, SFP can be swapped from a neighboring port. Example: Compare the RxPwr spec on J13 with a swapped port and run DVMR Link diagnostics again. This may indicate a bad cable connection or confirm a bad transmitting SFP. RxPwr too low - Might be fiber or remote side SFP problem Fault indicated without a replacement instruction. 13

Lesson 4: SFP Cleaning Procedure MR system utilizes a combination of Duplex LC (Male/Female) and MPO (Male/Female) connections. Protective caps should remain on all connectors until they are mated. Connectors left unmated for any period of time must be cleaned to minimize insertion lost. The GEHC Fiber Optics Cleaning Kit contains appropriate cleaning tools, supplies, and instructions to clean all of the interfaces of the SPF modules LC Duplex Cleaner MPO Cleaner GEHC Fiber Optics Cleaning Kit (Part Number: 5478006) Solvent Pen Cleaning Cube 14

SFP Cleaning Procedure Detailed SFP Connector Cleaning Instructions are included in the GEHC Fiber Optics Cleaning Kit (PN: 5478006). General Procedure: 1. Select the appropriate cleaner from the kit (LC Duplex or MPO) 2. Remove the top part of the cap on the cleaner 3. Remove the dust cap(s) on the SFP connector 4. Insert connector tips (include adapter if there is one) into cleaner; compress until it clicks 5. Remove SFP connector If Contaminant Persists After Using the Cleaner Tool 1. Apply Solvent (from pen) to cloth on the Cleaning Cube to wet the surface 2. Place the tip of the SFP connector to the wet surface 3. Clean by swiping in the direction the cloth comes out of the Cleaning Cube Note: Do Not Use the Cleaning Cube to Clean Male MPO Connector 15

Looking Forward GE Engineering is working on an extensive quality effort to extend the life of the optical communication of our scanners. MR Scanner utilization of SFP transceivers is unique from the industry in that they are essential to function components: when one optical link goes down, the scanner goes down. It s important for everyone who handles SFP transceivers to understand the failure modes and practice preventative actions to ensure customer confidence in our products. 16

Summary Always use ESD straps and silver static shielding packaging when handling SFP transceivers to avoid DLD latent effects Always clean the cable end and the SFP transceiver using the GEHC Optical Cleaning Kit (PN: 5478006) for every replacement Be careful not to pinch (micro bend) the optical fiber cable and leave a minimum of 7 inches bend radius (macro bend) Ensure the cable mates properly with the transceiver to prevent walk out if in doubt give the cable a little 17

Revision History Rev Page Description of Content Changed Reason for Change or Change Control Number Author Name / SSO Revision 1 All Initial Entry Initial Entry Brian Gracyalny / 212473777 See MyWorkshop 2 All Same content, MWS update for GE Learning 2018 distribution 05Jan2018 Brian Gracyalny / 212473777 See MyWorkshop 18