Hand-held Design Brings Peak Performance to the Field. Optical Multimeter AQ2150A

Similar documents
Optical Test and Measurement System AQ8200 Series

OTS-300 Express Series Power Meters/Sources and Testers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Agilent 8153A Lightwave Multimeter Technical Specifications

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

Optical Spectrum Analyzer 6317B

HP 70950B OPTICAL SPECTRUM ANALYZER

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

GFT Channel Digital Delay Generator

O-to-E and E-to-O Converters

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Light Source. Specification & User Manual

ST800K-U Optical Power Meter. User Manual V1.0

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Multi Application Test System

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Microwave Counter, Power Meter and DVM in One Portable Package

MAP Optical Power Meter Module (mopm-b1)

APD modules. Operates an APD with single 5 V supply (standard type, short-wavelength type) C12702 series.

Fiber Optic Meter Fiber Optic Source

Advanced Test Equipment Rentals ATEC (2832)

2 GENERAL DESCRIPTION

AQ2200Series. Ideal Measurement Solution for Optical Devices and Optical Transmission Systems. Multi Application Test System

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

OFI Optical Fiber Identifier User s Guide

OSICS 8-Channel Modular Platform for DWDM Testing

CMA4000i Optical Test System

LTS-1500 Fiber Optic Test Set Operating Instructions

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

MTS/T-BERD Platforms WDMPMD Module

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram

Model 4700 Photodiode Characterizer

Compact live fiber identifier with integrated optical power meter

Q8221. High-Accuracy, High-Sensitivity and High-Speed Optical Power Meter

Industrial Diode Laser (IDL) System IDL Series

1 Gang-sized Multi-format video to Optical DVI Converter, MVDF DATA SHEET

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

DPD80 Infrared Datasheet

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

AXS-200/350 OPTICAL LOSS TEST SET. part of the SharpTESTER Line LAN Applications

PV Series 850 nm VCSELs. Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

Fiber-optic Video Format Converters DATA SHEET

Datasheet: MultiFiber Pro Update

APD module. Variable gain, stable detection even at high gain. C Applications. Features. Sensitivity vs.

SM-10 SAT Level Meter User s Manual

IMPAC Infrared Thermometers

Fiber tester. Optical power meter XL-FM141. Optical power meter User s Manual

DPD80 Visible Datasheet

OPTICAL MEASURING INSTRUMENTS

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies

Fiber Meter. Specification & User Manual

Operating Manual. 50mW C-Band EDFA with GPIB and RS232 Interface

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Keysight FieldFox Microwave Analyzers

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Agilent FieldFox RF Analyzer N9912A

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

User's Guide to the PROLITE-30B

T-BERD /MTS-6000, -6000A and Platforms OFI Multifunction Loss Test Module

Peak sensitivity wavelength λp (nm) Photosensitive area (mm)

Miniature, Ruggedized 20 GHz RF over Fiber Transmitter

POLARIZED FIBER OPTIC SOURCE

SLD. Board FC/APC Connector. TEC Control. Board. Control Circuits. Control interface DB9 (Female)

ACION 8000 Series. A8KFR1 1RU Forward Receiver

KI7400C/7800C Series Optical Light Source KI7600C Series Optical Power Meter KI7300C/7700C Series Optical Loss Test Set

Full-featured CW Microwave Counters for Field, Factory or Lab

FRQM-2 Frequency Counter & RF Multimeter

ED5229GT-E Series. Page 1 of 8

Clamp 200 A AC/DC (+ V AC/DC + Ω)

Advanced Test Equipment Rentals ATEC (2832)

Optical Power Meter ML910B. Dual Inputs db Display Resolution Feed-Through Sensor Data Storage Function Traceable to NBS

Variable gain and stable detection even at high gains

DS2460Q QAM Analysis Meter

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Datasheet: CertiFiber Pro Optical Loss Test Set

Signal Stability Analyser

Agilent 81600B Tunable Laser Source Family

DATA SHEET. 32 x 32 DVI / HDMI /SDI Matrix, OMM Contents. OMM-2500 (Ver. 1.0)

Fiber Type Core/Cladding (um) Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

Photosensitive area (mm) 4 4. Peak sensitivity wavelength (nm) Supply voltage Dark state. Max. Vcc max. Tstg Min. Max. (ma) (V)

LD OEM/LD PDS/LD PeCo

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

MS9740A Optical Spectrum Analyzer

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

Options: - Master Patchcord - Launch cable - Set of optical adapters

iqs-1600/iqs-1700/ohs-1700 POWER METER AND OPTICAL HEAD SERIES

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

User s Manual of Signal Level Meter TABLE OF CONTENTS

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Transcription:

Hand-held Design Brings Peak Performance to the Field Optical Multimeter

2 Designed for manipulation

by fingertips The Optical Multimeter is designed for use in the field, with small size, light weight and ease of use. Swapping the LD/LED light source units (9 types), sensor units (6 types) and return loss units (2 types) makes it possible to use this handy instrument as an optical power meter, stabilized light source, loss test set or return loss measurement system. With handheld size and a weight of approx. 450 g, you can use it anywhere. And because it does not require an external power supply, it really shines in the field. Select the power source optimum for your needs at the time AC adapter, AA cells or Ni-Cd battery pack (option). Features Handles a variety of applications Optical fiber loss measurement Optical component measurement Free-space beam power measurement Near-end fault localization Return loss measurement for optical connectors and components High-output measurement Switchable LD/LED light source unit line-up You can switch between 1310 and 1550 nm by touching a button, meaning that you don t have to halt work to exchange plug-in units. Compact, lightweight Approx. 88(W) x 205(H) x 43(D) mm Approx. 450 g (base unit with DC pack, sensor unit and LED unit) Three power sources AC adapter Four AA alkaline cells AP2104 Ni-Cd Battery Pack (option) Long-term battery operative Powermeter mode Approx. 15 hours (alkaline cells) Approx. 20 hours (optional AP2104 Ni-Cd battery pack) Loss test mode (LD drive) Approx. 10 hours (optional AP2104 Ni-Cd battery pack) Fast charging The optional AP2103B Charger can quick-charge your unit in about an hour. All you have to do to get ready for work in the field is plug it in an hour before you leave. Includes overcharging protect function. 3

Examples Optical fiber loss measurement Optical fiber loss measurement requires the light source unit and the sensor unit. Both LED and LD light source units are available in designs with either 1310 nm, 1550 nm, or both wavelength For long optical fiber cables, please use the AQ4251 Reference measurement Station A LED unit Dummy cord DUT measurement Station A LED unit (131/155) LD Unit. Because it is switchable there is no need to swap units, and because it handles both wavelength you never have to worry about leaving one unit behind. Measured cable Station B Sensor unit High-output measurement It is possible to measure up to +21 dbm without shut down function for high-output optical transmission system when using high return loss adapter AQ9432 (*) Connector Adapter for AQ2752/2752B Sensor Unit. When high return loss adapter is used for system with shut down function, low-output is gained before it is connected to connector adapter and after that, it shifts to high-output. It is designed considering much of safety. High return loss adapter Localization of near-end faults Now it is possible to visually detect near-end faults on short fibers, undetectable with ODTR systems and without using complex He-Ne lasers. This can also be used for a selected fiber within a bundle. Fault localization Fiber core High-output optical transmission system Visual light LD unit Visual light LD unit Optical fiber cable Tape fiber Fault site Optical component measurement Measurement of optical components also requires the light source unit and the sensor unit. With the 1310/1550 nm switchable LD unit, loss can be measured up to 60 db. Optical connector and component return loss measurement The return loss unit has its own internal light source, sensor and coupler, making it possible to easily measure connector reflectivity attenuation. Free-space beam power measurement When measuring light with a beam spread, such as LD or LED sources, the thin AQ2755 Sensor Unit with its large diameter is optimum. The measurement range is through +20 dbm, for even high-output measurements. Optical component Return loss unit Measured connector LED unit Emission device Large-diameter sensor 4

Operation panel Protective cover This cover protects the connectors, and can be removed for use. It can be swung back under the base unit. LD/return loss unit Four LD units and two return loss units can be used. LED unit Four LED units can be used. Any of six sensor units can be used. (Note that the AQ7350 Sensor Unit cannot be used.) Display Used to display measured values and parameters. Unit release lever OPTICAL MULTIMETER OPT ON Uses to remove a unit. There is on located on each side of the base unit. Toggles the light output on/off. POWER Turns the unit on and off. ZERO Automatically adjusts the zero setting when the sensor is blocked. RANGE Toggles the measurement range between automatic and fixed. POWER POWER SAVE MOD OPT ON λ SHIFT SHIFT Switches between the measurement mode keys (functions written on the key tops) and the set-up mode keys (written above the key tops). (See below for details on set-up mode.) dbm W Toggles the measurement display units between dbm and W. DREF BACK LIGHT Toggles the backlight on the base unit on/off. Power supply ZERO BUZZER RANGE dbm W AVG DREF Sets the measurement when the key is pressed as the reference, and displays the next value as a relative with respect to the reference. UP/DOWN The DC pack, alkaline cells or Ni-Cd battery pack are mounted on the rear. BLKG BACK LIGHT REF VALUE REF Used to set the wavelength sensitivity correction, REF VALUE, and buzzer. REF Displays the measured value as a relative with respect to the preset REF VALUE reference. lset-up mode POWER SAVE Selects the power save time. BUZZER Sounds the buzzer when the measurement is above a preset threshold. BLKG Sets the display resolution for the measured value. MOD Toggles between CW light and chopped light. λ Used to set the light source unit wavelength and the sensor unit correction wavelength. AVG Toggles averaging processing on/off. REF VALUE Sets the reference value for display of relative value with REF key. 5

Specifications Base unit Display 7-segment, 4-digit Unit display Absolute: dbm, mw, µw, nw, pw, relative: db Calibration factor Correction of sensor wavelength sensitivity (5 nm steps) Ranges Automatic or fixed (up/down) Measurement mode Selectable to CW light or chopped light (270 Hz/1 khz/ 2kHz) Optical output waveform Selectable to CW light or chopped light (270 Hz/1 khz/ 2kHz) Measurement interval Approx. 330ms Averaging Selectable, sequential average (10/50/100 times), on/off Display resolution Selectable, 0.1/0.01 Zero set Automatic zero adjust Relative measurement Relative to reference setting value or displayed measurement value Backlight Backlight on while key pressed, and for 5s after release Auto power off Can be set to automatically shut down after 3 or 10 minutes without key operation, on/off Battery check Buzzer function Resume function Backup function Analog output Power supply Environmental conditions Dimensions and mass Accessories Low-battery display Operates when input level exceeds preset user-defined threshold Returns to state existing at power off Backs up settings during battery replacement (about 8 hours) 0 to approx. +2 V (for each range) AC adapter, dry cells (AA cells), Ni-Cd battery (option), approx. 1 VA Operating temperature 0 to 50 C, storage temperature -25 to +70 C, humidity 85 % RH max. Approx. 88(W) x 205(H) x 43(D) mm, approx. 450 g (with DC pack, sensor unit and LED unit) Approx. 88(W) x 265(H) x 43(D) mm, approx. 650 g (with dry cell battery pack and LD unit) DC pack, dry cell battery pack, AC adapter, analog output adapter, power cord (for AC adapter), instruction manual Model AQ2750 AQ2751 AQ2752/2752B 1) AQ2753 AQ2755 AQ2756 Unit name Sensor Unit Sensor Unit Sensor Unit Sensor Unit Sensor Unit Sensor Unit Wavelength range 400 to 1100 nm 750 to 1800 nm 750 to 1700 nm 750 to 1800 nm 400 to 1100 nm Reference wavelength 850 nm 1310 nm 850 nm Photodetector Si o 5.8 mm Ge φ 5 mm InGaAs φ 1 mm Ge φ 1 mm Si φ 18 mm Si o 10 mm Applications Large-diameter fiber, free-space beam 2) Small-diameter silica fiber emission 3) Free-space beam Large-diameter fiber, free-space beam 4) Input type Photodiode direct 5) AQ9431(*) Connector Adapter: option 6) Photodiode direct Photodiode direct 7) Power range CW light -80 to +10 dbm, (10 pw to 10 mw) -50 to +10 dbm, (10 nw to 10 mw) -80 to +10 dbm, (10 pw to 10 mw) -70 to +10 dbm, (100 pw to 10 mw) -50 to +20 dbm, (10 nw to 100 mw) -60 to +10 dbm, (1 nw to 10 mw) Chopped light -80 to +7 dbm, (10 pw to 5 mw) -60 to +7 dbm, (1 nw to 5 mw) -80 to +7 dbm, (10 pw to 5 mw) 8) -70 to +7 dbm, (100 pw to 5 mw) -50 to +17 dbm, (10 nw to 50 mw) -60 to +7 dbm, (1 nw to 5 mw) Noise level CW light -70 dbm -40 dbm -70 dbm -60 dbm 9) -40 dbm -50 dbm 9) Chopped light -75 dbm -50 dbm -75 dbm 8) -63 dbm 9) -45 dbm -55 dbm 9) Accuracy ± 5% (-20 dbm) 10) 1: Select AQ2752 or 2752B in accordance with modulation frequency caused in case of installation, etc. AQ2752: CW, 270 Hz, 1 khz, 2 khz or 100 MHz or more. AQ2752B: CW, or 100 khz or more. Can also be used with AQ9432(*) Connector. Please refer to order information for details. 2: Applicable optical fiber core diameter 200 mm, NA 0.44. 3: Applicable optical fiber core diameter 62.5 mm, NA 0.275. 4: Applicable optical fiber core diameter 0.4 mm, NA 0.5. 5: Can also be used with AQ9431(*) Connector Adapter. (*: Specify FC, SC, ST, DIN or HMS-10/A connector.) 6: * Specify FC, SC, ST, DIN or HMS-10/A connector. For information on other connectors, please consult your vendor or our sales offices. 7: Can also be used with AQ9317(*) Connector Adapter. *: connector type. FC standard. For information on other connectors, please consult your vendor or our sales offices. 8: Exclusively applicable to AQ2752. 9: At 0 to 40 C. 10: Ta=23 C, CW light, At reference wavelength. Light source unit (LED) Model AQ4250 (085) AQ4250 (131) AQ4250 (155) AQ4250 (131/155) Unit name LED Unit LED Unit LED Unit LED Unit Emission device LED Center wavelength 850 ± 30 nm 1) 1310 ± 30 nm 1) 1550 ± 35 nm 1) 1310/1550 ± 35 nm 1) Applicable fiber GI (50/125 µm) GI (50/125 µm) / SM (10/125 µm) SM (10/125 µm) Spectral halfwidth 2) 60 nm or less 140 nm or less 200 nm or less 140 nm or less (1310 nm), 200 nm or less (1550 nm) Optical output level 3) GI -15 dbm or more -25 dbm or more SM -40 dbm or more -43 dbm or more -42 dbm or more (1310 nm), -45 dbm or more (1550 nm) Optical output Temperature stability 0.3 db or less 4) 0.3 dbm or less 5) level stability Time stability ± 0.02 db or less 6) Optical connector AQ9433(*) Connector Adapter: option 7) 1: Ta=23 C, CW light. 2: Spectral halfwidth indicated as FWHM. 3: CW light. 4: 0 to 50 C (8 hours). 5: 0 to 40 C (8 hours). 6: Constant temperature, 5 minutes (one point between 20 and 30 C). 7: * Specify FC, SC, ST, DIN or HMS-10/A connector. For information on other connectors, please consult your vendor or our sales offices. Light source unit (LD) Model AQ4251 (131) AQ4251 (155) AQ4251 (131/155) AQ4254A (165) Unit name LD Unit LD Unit LD Unit DFB-LD Unit Emission device LD DFB-LD Center wavelength 1310 ± 20 nm 1) 1550 ± 20 nm 1) 1310 / 1550 ± 20 nm 1) 1650±5 nm 1) Applicable fiber SM (10/125 µm) Spectral width 2) 5 nm or less 10 nm or less 5nm or less (1310 nm), 10nm or less (1550 nm) 0.1 nm or less Optical output level 3) GI SM -6 dbm or more -7 dbm or more Optical output Temperature stability 1.0 db or less 4) 1.0 db or less 5) 3.0 db or less level stability Time stability ± 0.05 db or less 6) Within ±0.2 db 7) Optical connector AQ9434(*) Universal Adapter: option 8) 1: Ta=23 C, CW light. 2: Spectral width indicated as RMS (2 σ, -20 db), Ta =23 C, CW light 3: CW light. 4: 0 to 50 C (8 hours). 5: 0 to 40 C (8 hours). 6: Constant temperature, 5 minutes (one point between 20 and 30 C). 7: For five minutes, SM (10/125 µm) 2 m output end of Angled PC. 8: * Specify FC, SC, ST, DIN or HMS-10/A connector. For information on other connectors, please consult your vendor or our sales offices. 6

Light source unit (visible LD) Model AQ4252A (063) Unit name Visible LD Unit Emission device LD Wavelength 635 ± 10 nm 1) Applicable fiber SM (10/125 µm) Spectral width 2) 10 nm or less Optical output level 3) GI SM -3 ± 1.5 dbm Optical connector AQ9434(*) Universal Adapter: option 4) 1: Ta=23 C, CW light. 2: Spectral width indicated as RMS (2 σ, -20 db). Ta=23 C, CW light. 3: Outputs are CW light and 2 Hz blinking ligit. 4: * Specify FC, SC, ST, DIN or HMS-10/A connector. For information on other connectors, please consult your vendor or our sales offices. 5: can be mounted. With blinking ligit (2 Hz) function. Return loss unit Model AQ7350 (131) AQ7350 (155) Unit name Return Loss Unit Return Loss Unit Wavelength 1310 ± 20 nm 1) 1550 ± 20 nm 1) Dynamic range 40 db 2) Relative measurement accuracy ± 0.5 db or less (0 to 40 db) 3) Self-reflective attenuation 65 db or more 4) Applicable fiber SM (10/125 µm) Optical connector AQ9434(*) Universal Adapter: option 5) 1: Ta=23 C. 2: Atmospheric standard, with Super-PC master connector connected to output terminal. 3: Reference reflectivity used as absolute for accuracy, including effects of self-reflective attenuation. 4: Excluding output connector reflectivity. Splitter/coupler directivity. 5 :* Specify FC, SC, ST, DIN or HMS-10/A connector. For information on other connectors, please consult your vendor or our sales offices. 6: cannot be mounted. Order information Model & product name AQ2150 A Optical Multimeter AQ2750 Sensor Unit AQ2751 Sensor Unit AQ2752/2752B Sensor Unit AQ2752/2752B Sensor Unit Option 01 AQ2753 Sensor Unit AQ2755 Sensor Unit AQ2756 Sensor Unit AQ4250(085) LED Unit AQ4250(131) LED Unit AQ4250(155) LED Unit AQ4250(131/155) LED Unit AQ4251(131) LD Unit AQ4251(155) LD Unit AQ4251(131/155) LD Unit AQ4252A(063) Visible LD Unit AQ4254A(165) DFB-LD Unit AQ7350(131) Return Loss Unit AQ7350(155) Return Loss Unit Can be used with AQ9431 (*) Connector Select AQ9431 (*) Connector Can be used with AQ9432 (*) Connector. Use for measurement which requires high output and high return loss. Capable of high output measurement up to +21 dbm without operating shutdown function of system with EDFA.(*: FC, SC) Use with AQ9432 (*) Connector Adapter (*: FC, SC) (Cannot be removed. The power is calibrated at the factory.) Select AQ9431 (*) Connector Can be used with AQ9317 (*) Connector (*: FC standard) Select AQ9433 (*) Connector Select AQ9434 (*) Universal Model & product name AQ9302(*) Bare Fiber Adapter AQ9431(*) Connector Adapter AQ9432(*) Connector Adapter AQ9433(*) Connector Adapter AQ9434(*) Universal Adapter AP2103B Charger AP2104 Ni-Cd Battery Pack AQ2008 Sensor Cable AZ8115 Soft Case AZ8116 Carrying Case An adapter to convert optical fiber core cord to optical fiber with plug. Easy connection to AQ9431 Sensor with connector adapter. ( ): cord diameter. For information on cord diameters, please consult your vendor or our sales offices. For sensor unit High-return loss adapter for AQ2752/2752B Sensor Unit (*: FC, SC) Return loss: 40 db or more, internal return loss board with 13 db Applicable fiber: SM (1.31 µm, 1.55 µm) For LED light source unit For LD light source unit and return loss unit Requires the AP2103B Charger Extension cable Storage: Base unit (with sensor unit and LED unit mounted), sensor unit, light source unit, accessories (free storage) Dimensions: approx. 280(W) x 210(H) x 175(D) mm Storage: Base unit (with sensor unit and LED unit mounted), LD unit (or return loss unit), six connector adapters, two DC packs (or dry cell pack, Ni-Cd battery pack), AP2103B Charger, AC adapter (or base unit), cord (for AC adapter), instruction manual, fiber Dimensions: approx. 480(W) x 155(H) x 350(D) mm AP2103B AZ8115 7

System configuration Adapter Plug-in Unit Small-diameter silica fiber (core diameter 62.5, NA 0.275) AQ9431(*) Connector AQ2752/2752B/2753 Sensor Unit High-output optical transmission unit AQ9432(*) Connector AQ2752/2752B Sensor Unit Large-diameter fiber (core diameter 200µm, NA 0.44) AQ9431(*) Connector Bare fiber AQ9302(*)Bare Finder Adapter(Option) AQ2750/2751 Sensor Unit Free-space beam AQ2755 Sensor Unit Base Unit Optical fiber with plug AQ9433(*) Connector AQ4250 ( ) LED Unit AQ9434(*) Universal AQ4251 ( ) LD Unit/ AQ4252A(063) Visible LD Unit AQ4254A DFB-LD Unit AQ7350 ( ) Return Loss Unit Ando Electric Co., Ltd. 3-484, Tsukagoshi, Saiwai-ku, Kawasaki, Kanagawa, 212-8519 Japan Phone: +81 (0)44 549 7300 Fax: +81 (0)44 549 7450 Specifications are subject to change without notice. Ando Corporation 20420 Century Boulevard Germantown, MD 20874, U.S.A. Phone: +1 301 916 0409 Fax: +1 301 916 1498 SAN JOSE OFFICE: 2021 N. Capitol Avenue, San Jose, CA 95132, U.S.A. Phone: +1 408 941 0100 Fax: +1 408 941 0103 Ando Europe B.V. Vijverdam, Dalsteindreef 57, 1112XC Diemen, The Netherlands Phone: +31(0)20 698 1441 Fax: +31(0)20 699 8938 NIEDERLASSUNG DEUTSCHLAND: Nymphenburger Straße 119 B, D-80636 München, Germany Phone: +49(0)89 143 8150 Fax: +49(0)89 143 81555 Ando Electric Singapore Pte. Ltd. 19 Kim Keat Road #05-03, Fu Tsu Building, Singapore 328804 Phone: +65 251 1391 Fax: +65 251 1987 Please visit our website for more information: www.ando.com KT-1850-3 0112 KL230 Printed in Japan