TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

Similar documents
ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Cables for robot applications

Cable installation guidelines

Flygt Submersible Motor Cables

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Trends and Challenges of HV Cable Systems

Modular pulse operated latching relay 16 A

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Student Services & Classroom Addition

Connecting cables NEBS, for sensors

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Instructions. Cable with Armor F CAUTION. October Rev A

High Voltage Cables kv. Handling and Operating Instructions

Connectivity accessories by Nestor Cables

Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Panel-mounting thermostats, type series EM

HIGH VOLTAGE CABLE ACCESSORIES - Application, Design, Installation, Testing - Ivan Jovanovic G&W Electric Company

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

Connecting cables for valves, Sub-D Type codes

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Interface Connectors for Miniature, Portable Terminal Devices

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Connecting cables for valves, round plug connectors Product range overview

HARTING Ethernet cabling cables and connectors, 4 wire

Instrumentation Cables

AMERICAN NATIONAL STANDARD

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

An introduction to Kabeldon cable accessories kv

LEGEND POWER SYSTEMS

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Assembly Instructions

Non Magnetic Connectors

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

3M Sensored Termination (15 kv) QX-T15I-vi1-E

LED MODULES READYLINE DL

Type "N" Connectors. Type "N" Interface Dimensions

Laying of cables and lines in electrical installations and data networks

DOME OPTIC SPLICE CLOSURE

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

Filters for Power Lines (Low Leakage Current)

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Processing Specification MiniBridge IDC

Mechanical flow switch for On/Off control

Instrukcja montażu. FLEX LED Neon Instalacja

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Coaxial Cable Termination

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

FOSC 450 C6 and D6 Closures

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Panel-Mounted Thermostat

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Speed sensor MiniCoder GEL 2471

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

15 Series - Dimmer

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

BUS UNITRONIC BUS CAN

Ribbon Cable connector Compliant with MIL Standard

Ribbon Cable connector Compliant with MIL Standard

SMA One Piece Semi-Rigid Connectors

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

EXPlora. Introduction

Ribbon Cable connector Compliant with MIL Standard

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

CLP s first 400kV XLPE cable application

Gel-sealed in-line fiber optic closure

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009


0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Jul03 Rev C EC

12 Prefabricated cables

Bimetal Temperature Switch

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

The Custom Interconnect Leader TM

DIN Connectors DIN06 E-03

LED Driver Compact dimming

LCS 2 RJ 45 Cat. 6A HD panels and units

Transcription:

Accessories TERMINATIONS AND JOINTS FOR XLPE-INSULATED 12 36 kv MEDIUM VOLTAGE CABLES Cable Systems, Cables and Accessories

Test values for terminations 1) Testing to DIN VDE 0278-629-1 (Testing methods according to EN 61442) U 0 /U 6/10 U m 12 Voltage range test values 12/20 24 18/30 36 Test requirements DC withstand voltage, dry kv 36 72 108 15 min at 6 U 0, no breakdown or flashover AC withstand voltage, dry kv 27 54 81 5 min at 4.5 U 0, no breakdown or flashover AC withstand voltage, wet 2) kv 24 48 72 1 min at 4 U 0, no breakdown or flashover Partial discharge at increased temperature kv 12 24 36 max. 10 pc at 1.73 U 0 Impulse at increased temperature kv 75 125 170 10 impulses at each polarity, no breakdown or flashover Electrical heating cycles in air kv 15 30 45 126 cycles at 2.5 U 0, no breakdown Water bath testing 2) kv 12 24 36 10 cycles Partial discharge at ambient and increased temperature kv 12 24 36 max. 10 pc at 1.73 U 0 Thermal short circuit (screen) according to EN 61442 section 10 2 short circuits at I sc, no breakdown Thermal short circuit (conductor) according to EN 61442 section 11 2 short circuits to increase the conductor temperature to Θ sc, no breakdown Dynamic short circuit to be agreed upon 1 short circuit at I d, no breakdown Impulse at ambient temperature kv 75 125 170 10 impulses at each polarity, no breakdown or flashover AC withstand voltage, dry kv 15 30 45 15 min at 2.5 U 0, no breakdown or flashover Salt spray 2) kv 7.5 15 22.5 Duration: 1000 h at 1.25 U 0 Relative humidity 3) kv 7.5 15 22.5 Duration: 300 h at 1.25 U 0 1) Excerpt of test values for standard voltage range 2) Only applies to outdoor terminations 3) Only applies to indoor terminations 2

Content Test values for terminations 2 Welcome to Südkabel 3 Terminations 4-7 Indoor terminations 4 Outdoor terminations 5 Termination for electrostatic precipitators 111 kv s 6 Accessories for indoor and outdoor terminations 7 Joints and transition joints 8-10 Accessories for terminations, joints and transition joints 11 The systematic approach to cable accessories Our offer 12 Südkabel can look back on more than 40 years of experience in the field of silicone rubber cable accessories for up to 550 kv. This experience is also a decisive factor in order to be able to guarantee high-quality terminations and joints for XLPE-insulated 12 36 kv medium voltage cables. With the early introduction of preassembled insulating bodies, Südkabel made sure that critical assembly steps such as the manufacturing of stress control or insulation elements were taken from the building site to the manufacturing plant. The standard range of cable accessories for XLPE-insulated medium voltage cables includes plug-in terminations for metal-enclosed switchgears with inner or outer cone, joints with multi-range applications and transition joints is completed by multi-range terminations for indoor and outdoor applications as well as terminations for electrostatic precipitators. Our medium voltage accessories are also approved for networks or applications up to 42 kv under increased testing demands. 3

Indoor terminations Multi-range TERMINATIONS 12 36 kv Indoor terminations with silicone rubber slip-on technology are set on cables with an insulation made of cross-linked polyethylene (XLPE). Various optimisations have led to today's coon multi-range terminations for 12 and 24 kv. This type of termination covers up to five conductor cross sections with one insulating body and is compatible with press-fit and screw cable lugs. The applied insulating body material features relatively low shore hardness (A). This helps to achieve good adjustment to irregularities in the XLPE cable cores that potentially occur when stripping the welded exterior conductive layer. This makes post-processing of the stripped cores unnecessary. The indoor terminations significantly exceed the requirements of DIN VDE 0278-629-1. A breakout is required for application with three-core cables. For cable mounting, special cable fixings are available. 1 2 D 3 H 4 6 5 7 1 Cable lug for conductor connection 2 Insulation tube 3 Insulator 4 Stress control element 5 Exterior conductive layer 6 Screening cable lug 7 Exterior screen Type *) for cables according to DIN VDE 0276-620 Admissible core diameter Measure H Measure D Conductor cross section *) ² SEHDI 10.2 13.3 20.8 205 46 35 95 SEI 12 16.8 24.3 205 50 70 150 SEI 12 21.5 32.6 205 54 185 300 SEHDI 10.2 26.5 40.9 205 46 300 630 SEI 24 16.8 24.3 205 50 25 70 SEI 24 21.5 32.6 205 54 95 240 SEHDI 20.2 30.0 45.0 215 69 300 630 SEHDI 30.1 22.9 27.8 270 77 35 50 SEHDI 30.1 25.1 30.5 270 77 70 95 SEHDI 30.1 28.3 34.4 270 77 120 150 SEHDI 30.1 31.5 38.3 270 83 185 240 SEHDI 30.1 35.6 43.3 270 83 300 400 SEHDI 30.1 42.2 50.1 270 88 500 630 4

Outdoor terminations Multi-range TERMINATIONS 12 36 kv Outdoor terminations with silicone rubber slip-on technology are set on cables with an insulation made of cross-linked polyethylene (XLPE). Various optimisations have led to today's coon multi-range terminations for 12 and 24 kv. This type of termination covers up to five conductor cross sections with one insulating body and are compatible with press-fit and screw cable lugs. The applied insulating body material features relatively low shore hardness (A). This helps to achieve good adjustment to irregularities at XLPE cable cores that potentially occur when stripping the welded exterior conductive layer. This makes post-processing of the stripped cores unnecessary. The outdoor terminations significantly exceed the requirements of DIN VDE 0278-629-1. A breakout is required for application with three-core cables. For mounting at pole traverses or scaffolding, special mounting clamps are available. 1 2 3 H D 7 8 4 5 6 9 1 Cable lug for conductor connection 2 Insulation tube 3 Insulator 4 Stress control element 5 Exterior conductive layer 6 Sealing kit 7 Ribbon clamp 8 Screening cable lug 9 Exterior screen Type Admissible core diameter Measure H Measure D Conductor cross section *) ² SEHDF 10.2 13.3 20.8 225 105 35 70 SEHDF 10.2 16.8 24.3 260 88 95 150 SEF 12 21.5 32.6 260 92 185 300 SEHDF 10.2 30.0 45.0 22 120 400 630 SEHDF 20.2 16.8 24.3 260 88 25 70 SEF 24 21.5 32.6 260 92 95 240 SEHDF 20.2 30.0 45.0 225 120 300 630 SEHDF 30.1 22.9 27.8 380 133 35 50 SEHDF 30.1 25.1 30.5 380 133 70 95 SEHDF 30.1 28.3 34.4 380 138 120 150 SEHDF 30.1 31.5 38.3 380 138 185 240 SEHDF 30.1 35.6 43.3 380 144 300 400 SEHDF 30.1 41.2 50.1 380 151 500 630 *) for cables according to DIN VDE 0276-620 5

Termination for electrostatic precipitators 111 kv s These terminations are especially designed for type A2XSY 1x50RM/16 111 kv s electrostatic precipitators and meet the special requirements of electrostatic filters. 1 D 2 H 6 7 3 4 5 8 1 Conductor contact pin 2 Insulator 3 Stress control element 4 Exterior conductive layer 5 Sealing kit 6 Ribbon clamp 7 Screening cable lug 8 Exterior screen Functionality The components of electrostatic filters are subject to electrical impulseshaped stresses. The voltage increases according to the charging properties of a capacitor and abruptly drops after voltage flashover in the filter. Afterwards, the charging process is restarted. Type Bore diameter of the insulating body Admissible core diameter Measure H Measure D Conductor cross section SEHDL 23.5 25.5 30.0 425 170 50 SEHDL 31.3 33.5 38.5 425 170 50 ² 6

ACCESSORIES FOR INDOOR AND OUTDOOR TERMINATIONS Preassembled cable and high flexible cable links are XLPE cables or flexible EPR-insulated trailing cables which are equipped with terminations in the factory. They are primarily used for connections between transformers and switchgear or for special applications like electrically-powered trains. 1 D SEIK SET 2 SEW SEI 3 D 2 min 110 min 110 130 14 95-115 12 120 236 34 60 130 80 145 1 BSW fixing clamp 2 Reduction insert 3 BSS fixing clamp D 30 50 Preassembled cable and high flexible cable links 12 36 kv The minimum bending radius typical for flexible trailing cables is ideal for installation in narrow areas. Rationalization of substation assembly thanks to no termination installation being carried out at the installation site. The accessory equipment of the links can be chosen freely for any combination of terminations and plug-type connectors admissible for that particular type of cable or trailing cable. Output check can be agreed upon. Type Admissible current load *) A Short circuit current 1 s Outer diameter Minimum bending radius Trailing cable 24 kv NTMCWOEU 35 ² 240 5 29.5 145 NTMCWOEU 50 ² 300 7.2 31.5 155 Cable 24 kv N2XSY 35 ² 235 5 30 450 N2XSY 50 ² 282 7.2 34 550 Fixing clamps for outdoor terminations Outdoor terminations can withstand transverse forces only to a limited extend. Potentially occurring mechanical loads after short-circuits and cable oscillations or due to the inherent rigidity of the cable can be controlled by means of suitable fixing clamps. BSW fixing clamps that are especially designed for SEHDF outdoor terminations (for horizontal mounting) and BSS fixing clamps (for vertical mounting) are made of glass fibre reinforced UV-resistant polyamide. They are characterised by a large clamping length of 100 for ideal mounting while observing the admissible surface pressure of the cable. Adjustment to individual external cable diameters is enabled by different reducers. Fixing clamps can be used for all coon dimensions on panels in 5 increments. Various reducers enable adjustment of individual external cable diameters. *) Air installation at an ambient temperature of 30 C 7

JOINTS AND TRANSITION JOINTS JOINTS 12 36 kv The SEV joint with slip-on technology serves as the connection between two plastic-insulated cables with 12, 24 or 36 kv. 9 7 1 2 3 4 5 6 8 9 10 1 Insulating body 2 Stress controlling layer 3 Conductive outer coating 4 Press-fit connector 5 Shrinkable tube 6 XLPE cable core 7 Copper braided tape 8 Screen wires 9 Sealing wrap 10 XLPE cable The multi-range capability enables use of up to five cross sections with one insulating body size. The single-part, triple-extruded insulating body is made of silicone rubber and consists of a refractive stress control element, silicone insulation and an external conductive layer. The conductor connection can either be realised with screw or press-fit connectors. Connections within one joint size can be realised without any problems. The metal screen of the joint consists of one winding of braided copper tape. The external mechanical protection is usually provided by a heat shrinkable tube. Optionally, corrosion protection tape can be used. SEV multi-range joints meet the requirements of DIN VDE 0278-629-1. Type Voltage U max kv Conductor cross section ² Admissible core diameter SEV 12 12 50 95 15.5 20.8 SEV 12 12 120 240 18.9 28.4 SEV 12 12 300 500 27.4 36.4 SEV 24 24 50 150 18.9 28.0 SEV 24 24 95 240 22.8 32.6 SEV 24 24 240 400 29.5 39.6 SEV 24 24 300 500 30.9 40.9 SEV 24 24 630 39.1 50.1 SEV 24 24 800 1000 44.6 57.8 SEV 36 36 50 120 23.5 32.5 SEV 36 36 150 300 29.5 39.6 SEV 36 36 800 1000 44.6 57.8 8

JOINTS AND TRANSITION JOINTS TRANSITION JOINTS 24 kv SEVü transition joints with slip-on technology are used to connect paper-insulated cables with plastic-insulated cables. 11 1 2 3 4 5 6 7 8 9 10 1 Insulating body 2 Stress controlling layer 3 Conductive outer coating 4 Press-fit connector 5 Stress control tape 6 Silicone tape 7 Copper braid 8 Roller spring 9 Shrinkable tube 10 Paper-insulated cable 11 XLPE-cable SEVü can be compared to SEV and offers the same features (multi-range capability, application of press-fit and screw connectors). Additional mounting steps are only required on the paper-insulated cable side. The paper-insulated cable side is prepared with tape to ensure that the impregnating compound of the paper-insulated cable cannot come into contact with the insulating body. This technology is referred to a dry transition joint. In connection with XLPE cables with paper-insulated single-core cables, the external mechanical protection is provided by a shrinkable tube. SEVü. When used on paper-insulated three-core cables, these cables are first of all divided up into its individual cores with a cable breakout and then treated as single-core cables. AM/SEVü. SEVü transition joints meet the requirements of DIN VDE 0278-629-2. Type Voltage kv For connection of single-core XLPE cables and paper-insulated... Paper-insulated cable ² Conductor cross section XLPE cable ² Admissible core diameter SEVü 24 24... Single-core cables 35 150 50 150 18.9 22.0 AM/SEVü-B24 24... SL-type cables 35 240 95 240 22.8 32.6 185 300 300 30.9 40.9 AM/SEVü-H24 24... H-type cables 35 150 50 150 17.5 25.0 35 240 95 240 9

JOINTS AND TRANSITION JOINTS TRANSITION JOINTS 24 kv SEHDVü transition joints with slip-on technology are used to connect paper-insulated cables with plastic-insulated cables. 2 3 1 L 1 XLPE cable 2 H-type or SL-type cable 3 Shrinkable cable breakout The single-part insulating body is made of silicone rubber and includes the stress control elements as well as an earthing reservoir for earthing the paper-insulated cable near the joint. This technology is referred to as a wet transition joint. Factory-equipped additional elements like insulating bodies, sealing parts and joint pipes enable easy and very quick mounting without soldering. In connection with XLPE cables with paper-insulated single-core cables, the external mechanical protection is provided by a shrinkable tube. SEHDVü. When used on paper-insulated three-core cables, these cables are first of all divided up into their individual cores with a cable breakout and then treated as single-core cables. AM/SEHDVü. SEHDVü 20 transition joints meet the requirements of DIN VDE 0278-629-2. Type Conductor cross section Length measure L XLPE cable ² Earthing cable ² approx. in SEHDVü 20 95 35 95 1000 SEDVü 20 120 50 120 1000 SEHDVü 20 150 70 150 1000 SEHDVü 20 185 95 185 1000 SEHDVü 20 240 120 240 1000 AM/SEHDVü 20 95 35 95 1400 AM/SEHDVü 20 120 50 120 1400 AM/SEHDVü 20 150 70 150 1400 AM/SEHDVü 20 185 95 185 1400 AM/SEHDVü 20 240 120 240 1400 10

ACCESSORIES FOR TERMINATIONS, JOINTS AND TRANSITION JOINTS Polyamide fixing clamps for single and multi-core cables. Glass-fibre reinforced polyamide fixing clamps are used to fasten cables at poles, in stations and cable racks. L 2 d L 2 L 1 B d L 2 d B L 1 L 1 B L Type K (mechanical short-circuit resistance of 10,000 N) for mounting of single and multi-core cables. Type KP (mechanical short-circuit resistance of 25,000 N) for mounting single and multi-core cables in trefoil formation with increased short-circuit stress. Type KS (mechanical short-circuit resistance of 12,500 N) for mounting single and multi-core cables in trefoil formation. Sheath cutter WM 20.1 Sheath cutters are used to remove exterior PE insulations and XLPE insulations off medium voltage cables. Stripping tool WL 20.1 Stripping tools are used to remove the welded exterior conductive layer of XLPE-insulated medium voltage cables. Additional accessories Products for cable installation and laying: Earthing material for cables with copper tape screens Shrinkable cable breakout for three-core XLPE cables RUK500 cable cleaning agent for cable sheaths and insulations Cable bundling tape for short-circuit-proof bundling of single-core cables Type K26/38 K36/52 K50/75 K66/90 KP29/41 KP39/53 KS26/36 KS33/46 Suitable for the following cable diametes in 26 38 36 52 50 75 66 90 29 41 39 53 25 36 33 46 Measure L 1 90 105 126 158 172 190 150 170 Measure L 2 60 75 95 120 125 145 110 130 Measure B 60 60 60 70 80 80 80 80 Measure D 12 12 12 14 14 14 12 12 11

OUR OFFER www.janus-wa.de Cables XLPE-insulated cables from 6 kv to 500 kv Cable systems Turnkey XLPE-insulated cable systems up to 500 kv Accessories for medium, high and extra-high voltage cables Outdoor terminations Conventional and plug-in terminations for SF 6 switchgears and transformers Cable Joints Plug-in terminations for outer and inner cone systems Medium voltage cable links Services Consulting service on application related questions Training for installation personnel Cable laying and supervision of laying Installation of accessories Coissioning After sales services Accessories for electrostatic precipitator cables Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. Südkabel does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction in whole or in part is forbidden without Südkabel s prior written consent. Copyright 2014 Südkabel. All rights reserved. Südkabel GmbH Rhenaniastrasse 12-30 68199 Mannheim Phone: +49 621 8507 01 Fax: +49 621 8507 294 E-mail: info@suedkabel.com www.suedkabel.de Südkabel 3004 E