Accessories EXTENSION CABLE OPTIONS - HOW TO ORDER. Standard 6-Pin connector type (D60) used with R-Series G-Series. Type DJ.

Similar documents
Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

Connectors, self-assembly

BUS UNITRONIC BUS CAN

Connectors, self-assembly

Connectivity for Ethernet

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

MAGNETOSTICTIVE TRANSDUCER

Single Point Flow Monitor SW118 SW119

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Absolute encoders multiturn

Inductive sensor NI10-M18-Y1X-H1141

Linear encoders without bearings incremental System for linear motion feedback

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Inductive sensor NI3-EG08K-Y1-H1341

INVISILED ACCESSORIES

Linear measuring technology

Inductive sensor BI1.5-EG08K-Y1

Absolute Encoders Multiturn

PROPORTIONAL VALVES Sentronic plus

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Bus Cables & Industrial Ethernet Cables

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Connecting cables for valves, round plug connectors Product range overview

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

APPLICATIONS. Automatic warehouse. Trasportation lines

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

APPLICATIONS. Automatic warehouse. Trasportation lines

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES 400 SERIES 620

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

DRAW WIRE SENSOR. Series SX80. Key-Features: Content:

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

Inductive sensor With analog output BI15-M30-LI-EXI

INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE

Flow Measurement SITRANS F M

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

BNCpro for 3G and Ultra-HD/4K

Mechanical flow switch for On/Off control

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

TE Connectivity DEUTSCH ACT Series MIL-DTL Series III Composite Connectors

Covid HDBase-T Receiver for HDMI with Built in Audio de-embedding, IR, and RS232 control pass through

Photoelectric Sensors E3F2

part numbers 5 VDC ±5% 5 VDC ±5% 35 ma 30 ma RS 422 3,2 MHz < 4 VDC 160 khz RS 422

DRAW WIRE SENSOR 提夫自控技术 ( 上海 ) 有限公司. Series SX120. Key-Features: Content:

Read/write head TN-M18-H1147

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

TFR5 Room or outdoor temperature sensor. CombiTemp TM

IMPAC Infrared Thermometers

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

Magnetic Sensor - Incremental EHP

DRAW WIRE SENSOR. Series SX50. Key-Features: Content:

Speed sensor MiniCoder GEL 2471

Connecting cables for valves, Sub-D Type codes

LED Series Sealed Backlights

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

Connecting cables NEBS, for sensors

HARTING Ethernet cabling cables and connectors, 4 wire

WLC60 Heavy Duty LED Light - PWM Dimmable

lumenalpha spot Specification Sheet

KEL 24 Cable entry frames

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

Automation. Automation. Guide for Servo Motors/Drives and BUS Systems. Make the right connection.

Capacitive sensor BCT5-S18-UP6X2T-H1151

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

Control cabinet interface and cable entry systems

Dissolved Oxygen Transmitter

TFRN Industrial RTD temperature sensor. CombiTemp TM

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Linear Array with Intensity Adjustment

The Custom Interconnect Leader TM

Dissolved Oxygen Transmitter

RoHS. All incremental or absolute Sendix encoders with clamping flange (centering collar 36 mm) and 10 mm shaft diameter (shaft 10x20 mm) can be used.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DL-AR2 Technical Specifications Universal HDMI Adapter Ring Rev

TURCK Network Media Products

PT9150. Heavy Industrial Incremental Encoder

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

DRAW WIRE SENSOR. Series SX50. Key-Features:

Selection matrix for electronic pressure switches

TFRN Industrial RTD temperature sensor. CombiTemp TM

LM10 linear magnetic encoder system

Connection Guide of the MOTOTRBO radio to the radioserver as a control station

Transcription:

EXTENSION CABLE OPTIONS - HOW TO ORDER Standard 6-Pin connector type (D60) used with R-Series G-Series 1 2 3 4 5 6 7 8 K6 = Female connector, (straight exit), and standard (PVC jacket) for sensors with D6 or D60 connector D6 = Female connector, (straight exit), and standard #530026 (PVC jacket) for sensors with D6 or D60 connector DA = Female connector, (90 exit), and standard # 530026 cable (PVC jacket) for sensors with D6 or D60 connector. DJ = (No more product) Female connector, (straight exit) and # 530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector. DK = (No more product) Female connector, (90 exit), and #530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector. DC= Female connector, (straight exit), and standard # k34 (Teflon jacket) for sensors with D6 or D60 connector R6 = Female connector, (straight exit), and moving cable(black polyurethane jacket) for sensors with D6 or D60 connector D6H= Female connector, (straight exit), and standard # 530052 (orange polyurethane jacket) for sensors with D6 or D60 connector CABLE LENGTHS* (3-5) For standard length cables up to 100 ft. 005 = 5 ft. 015 = 15 ft. 025 = 25 ft. 050 = 50 ft. 100 = 100 ft. _ = length (ft)* Type DJ CABLE TERMINATION (2 or 3 characters depending on option selected) (6-8) D6M = D6 male connector, (Straight exit). Only available with the D6 option above. D6 F = Female connector, (straight exit). Only available with the D6 option above. DAF = Female connector, (90 exit). Only available with the DA option above. Type DK * Refer to Length Limitations table on page 55 for maximum cable length. Standard 6-Pin connector type (D60) used with R-Series G-Series M 1 2 3 4 5 6 7 8 9 K6 = Female connector, (straight exit), and standard (PVC jacket) for sensors with D6 or D60 connector D6 = Female connector, (straight exit), and standard #530026 (PVC jacket) for sensors with D6 or D60 connector DA = Female connector, (90 exit), and standard # 530026 cable (PVC jacket) for sensors with D6 or D60 connector. DJ = (No more product) Female connector, (straight exit) and # 530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector. DK = (No more product) Female connector, (90 exit), and #530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector. DC= Female connector, (straight exit), and standard # k34 (Teflon jacket) for sensors with D6 or D60 connector R6 = Female connector, (straight exit), and moving cable(black polyurethane jacket) for sensors with D6 or D60 connector D6H= Female connector, (straight exit), and standard # 530052 (orange polyurethane jacket) for sensors with D6 or D60 connector CABLE LENGTHS* (3-6) For standard length cables up to 100 M. 005M = 5 M. 015M = 15 M. 025M = 25 M. 050M = 50 M. 100M = 100 M. _ M_ = length (M)* Type DJ CABLE TERMINATION (2 or 3 characters depending on option selected) (7-9 ) D6M = D6 male connector, (Straight exit). Only available with the D6 option above. D6 F = Female connector, (straight exit). Only available with the D6 option above. DAF = Female connector, (90 exit). Only available with the DA option above. Type DK * Refer to Length Limitations table on page 55 for maximum cable length.

EXTENSION CABLE OPTIONS - HOW TO ORDER 6-Pin connector type (D63) used with R-Series Profibus Sensors D 1 2 3 4 5 6 7 8 DF = Female connector, (straight exit), and #530040 cable for Profibus sensors with D63 connector DG = Female connector, (90 exit), and #530040 cable for Profibus sensors with D63 connector DM = Male connector, (straight exit), and #530040 cable for Profibus sensors with D63 connector Type DG CABLE LENGTHS* (3-5) For standard length cables up to 100 ft. 005 = 5 ft. 015 = 15 ft. 025 = 25 ft. 050 = 50 ft. 100 = 100 ft. _ = length (ft)* CABLE TERMINATION (2 or 3 characters depending on option selected) (6-8) DFM = Male connector, (Straight exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DF option above. DGM = Male connector, (90 exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DG option above. * Refer to Length Limitations table on page 55 for maximum cable length. 6-Pin connector type (D63) used with R-Series Profibus Sensors D M Type DG 1 2 3 4 5 6 7 8 9 DF = Female connector, (straight exit), and #530040 cable for Profibus sensors with D63 connector DF = Female connector, (straight exit), and violet bus cable for Profibus sensors with D63 connector DG = Female connector, (90 exit), and #530040 cable for Profibus sensors with D63 connector DM = Male connector, (straight exit), and #530040 cable for Profibus sensors with D63 connector DM = Male connector, (straight exit), and violet bus cable for Profibus sensors with D63 connector CABLE LENGTHS* (3-6) For standard length cables up to 100 M. 005M = 5 M. 015M = 15 M. 025M = 25 M. 050M = 50 M. 100M = 100 M. _ M_ = length (M)* Type DF DM CABLE TERMINATION (2 or 3 characters depending on option selected) (7-9) DFM = Male connector, (Straight exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DF option above. DGM = Male connector, (90 exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DG option above.

EXTENSION CABLE OPTIONS - HOW TO ORDER Standard 7-Pin DIN connector type (D70) used with R-Series SSI Sensors 1 2 3 4 5 6 7 8 9 SENSOR CONNECTION TYPE (1-3) K7 = Female connector, (straight exit), and standard (PVC jacket) for sensors with D70 connector D7 = Female connector, (straight exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector. R7 = Female connector, (straight exit), and moving cable(black polyurethane jacket) for sensors with D70 connector DR = Female connector, (90 exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector. DS = Female connector, (straight exit) and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector. DT = Female connector, (90 exit), and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector. DU = (No more product) Female connector, (straight exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector. = (No more product) Female connector, (90 exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector. D7C= Female connector, (straight exit), and standard # k34 (Teflon jacket) for sensors with D7 or D70 connector D7H= Female connector, (straight exit), and standard # 530052 (orange polyurethane jacket) for sensors with D7 or D70 connector CABLE LENGTHS* ( -6) For standard length cables up to 100 ft. 005 = 5 ft. 015 = 15 ft. 025 = 25 ft. 050 = 50 ft. 100 = 100 ft. _ = length (ft)* CABLE TERMINATION (2 or 3 characters depending on option selected) (7-9) D7F = Female connector, (straight exit). Only available with the D7 option above. * Maximum cable length is dependent on the baud rate (refer to Length Limitations table on page 55) Type D7 Standard 7-Pin DIN connector type (D70) used with R-Series SSI Sensors 1 2 3 4 5 6 7 8 9 10 SENSOR CONNECTION TYPE (1-3) K7 = Female connector, (straight exit), and standard (PVC jacket) for sensors with D70 connector D7 = Female connector, (straight exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector. R7 = Female connector, (straight exit), and moving cable(black polyurethane jacket) for sensors with D70 connector DR = Female connector, (90 exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector. DS = Female connector, (straight exit) and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector. DT = Female connector, (90 exit), and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector. DU = (No more product) Female connector, (straight exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector. = (No more product) Female connector, (90 exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector. D7C= Female connector, (straight exit), and standard # k34 (Teflon jacket) for sensors with D7 or D70 connector D7H= Female connector, (straight exit), and standard # 530052 (orange polyurethane jacket) for sensors with D7 or D70 connector CABLE LENGTHS* ( -7) For standard length cables up to 100 M. 005M = 5 M. 015M = 15 M. 025M = 25 M. 050M = 50 M. 100M = 100 M. _ M_ = length (M)* M CABLE TERMINATION (2 or 3 characters depending on option selected) (8-10) D7F = Female connector, (straight exit). Only available with the D7 option above. * Maximum cable length is dependent on the baud rate (refer to Length Limitations table on page 55) Type D7 s with D70 connector.

ADAPTER CABLE OPTIONS FOR REPLACING RETIRED SENSOR MODELS (Temposonics I, II & L-SERIES) Product Dimension Application Used when replacing Tempo II and model LH sensors that have integral RB connectors Part no: 253243, -1, -2 male RB connection adapter cables -1 1 ft. cable length, standard For G-Series analog output sensors -2 1 ft. cable length, standard For G-Series digital-pulse and neuter output sensors Part no: 253244, -1, -2 male RB connection adapter cables -1 5 ft. cable length For G-Series analog output sensors -2 5 ft. cable length For G-Series digital-pulse and neuter output sensors Used when replacing Tempo II sensors that have integral RC connectors Part no: 201612, -1, -2 male RC connection adapter cables -1 1 ft. cable length, standard For G-Series analog output -2 1 ft. cable length, standard for G-Series digital-pulse and neuter output Used when replacing model LH sensors that have integral or in-line 10-pin MS connectors Part no: 253245, -1, -2 male MS connection adapter cables -1 1 ft. cable length, standard For G-Series analog output -2 1 ft. cable length, standard For G-Series digital-pulse and neuter output Part no: 253246, -1, -2 male MS connection adapter cables -1 5 ft. cable length For G-Series analog output sensors -2 5 ft. cable length For G-Series digital-pulse and neuter output sensors Used when replacing Tempo II and model LH sensors that have in-line MS connectors wired for the R1, R2, or R3 connection types Part no: 253245-3 male MS (R1, R2, or R3 connection) adapter cables -3 1 ft. cable length For R3 connection using G-series digital-pulse output Part no: 253246-3 male MS (R1, R2, or R3 connection) adapter cables -3 5 ft. cable length For R3 connection using G-series digital-pulse output Part no: 253302, -1, -2 male MS (R1, R2, or R3 connection) adapter cables -1 5 ft. cable length For R1 (positive interrogation) connection using G-Series -2 5 ft. cable length For R2 (negative interrogation) connection using G-Series

ADAPTER CABLE OPTIONS FOR REPLACING RETIRED SENSOR MODELS (Temposonics I, II & L-SERIES) Product Dimension Application Used when replacing models LH, LP and R-Series sensors that have integral RG connectors Part no: 253248, -1, -2 male RG connection adapter cables Part no: 253315, -1, -2 Female straight exit D7 to male RG connection adapter cables -1 1 ft. cable length, standard -2 5 ft. cable length For R-Series analog or G-Series analog and digital-pulse output sensors For R-Series analog or G-Series analog and digital-pulse output sensors -1 1 ft. cable length, standard For R-Series SSI output sensors -2 5 ft. cable length For R-Series SSI output sensors Used when replacing model LP sensors that have the integral C-style connector or in-line H or J style connectors Part no: 253247, -1, -2, -3, -4 male AMP connection adapter cables. -1 1 ft. cable length For G-Series analog output sensors -2 1 ft. cable length For G-Series digital-pulse output sensors -3 7 ft. cable length For G-Series analog output sensors -4 7 ft. cable length For G-Series digital-pulse output sensors Product Dimension Application Part no. 401327 Male RC to female RB connector adapter. 6 in. overall length For retrofitting RC connection style Temposonics II or model LH sensors CONNECTORS (For Current Production Sensors) 5-pin style connectors Product Dimension Material Application Part no. 370375 D51 Field-installable connector 20mm (0.8in.) 55m m (2.2in.) Female, straight exit, for Model R-Series sensors with DeviceNet output Part no. 370376 D51 Field-installable connector 41mm (1.6in.) 37 mm( 1.5 in) Female, 90 exit, for Model R-Series sensors with DeviceNet output

R-Series Catalogue ACCESSORIES R-SERIES Position Magnets, Floats, Connectors, Clamps, s and Programming Tools Product Dimension Material Application Clamp Part No. 400 802 Stainless steel RP Stainless steel RP Groove stone Part No. 401 602 Aluminum RH Spacer Part No. 400 633 Brass Fixing clip Part No. MT 0200 Flat section and fastening screws: non-magnetic material RH Analogue, CAN, SSI, Profibus Metal protection cap for connector M16 Part No. 403 290 Edelstahl RH-M Hex nut Part No. 500 018 Part No. 530 026 3 x 2 x 0,14 mm 2 Ø 6 mm PVC -10... +80 C Standard Halogen free 3 x 2 x 0,25 mm Ø 6,8 mm Pelon PUR -40... +80 C Oil-resistant High flexible Part No. 530 052 Notice: Product pictures may vary from original.

R-Series Catalogue ACCESSORIES R-SERIES Position Magnets, Floats, Connectors, Clamps, s and Programming Tools Product Dimension Material Application 4 x 2 x 0,25 mm 2 PUR (-30... +90 C) Water proof wires Part No. 530 116 4 x 2 x 0,25 mm 2 Teflon (-90... +180 C) Temperature Part No. 530 112 Part No. 530 029 7 x 0,14 mm 2 EMC protected Ø 7 mm PUR -20...+70 C SSI, CAN BUS + feed-in Ø 8 mm PVC -30... +80 C Profibus-DP D63 Part No. 530 040 BUS conductor, high flexible cable Ø 8 mm PUR -30... +70 C Profibus-DP D53 Part No.530 109 Product Description Hand-Programmer R-Analogue for 1-Magnet Sensor is for easy teach-in-setups of measuring length and direction on desired Zero/Span positions. Hand-Programmer R-Analogue Part No. 253 124 Cabinet-Programmer R-Analogue Cabinet-Programmer R-Analogue completes the accessories program of MTS absolute position The unit can be used for adjusting a connected 1-magnet sensor via the leads, using a simple teach-in procedure in the field. Cabinet-Programmer Part Nr. 253 408 Notice: Product pictures may vary from original.