COMMANDER SR100A & SR100B

Similar documents
Section C Recorders. DPR mm Digital Strip Chart Recorder

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Wall-/Pipe-Mount Level Indicator

DCP100 Digital Control Programmer Specifications

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Pen and Multichannel Recorder: Digital Display

Modular Lube Lubrication Systems System Controls

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Application Note 11 - Totalization

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

ControlMaster CM15 Universal process indicator 1 /8 DIN

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

Modbus Register Tables for SITRANS RD300 & WI100

Condition Monitoring Custom Products

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LARGE DIGITAL TEMPERATURE LED DISPLAYS

Process Transmitter RMA 422

EVENT INPUT/OUTPUT MODULE [PUME]

ControlMaster CM15 Universal process indicator 1 /8 DIN

actions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments

Hybrid Chart Recorder 250 mm (10")

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

VIP-1E Controller Installation, Operation and Programming Guide. Form No Effective 12/01/11

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

The measurements are stored in non-volatile memory, which retains data even when the power down.

SPECIFICATION NO Model 207 Automatic GTAW Welding System

High Speed Temperature and Process Signal Measurement System

GFT channel Time Interval Meter

Process transmitter RMA422

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SPECIFICATION NO NOTE

KS 3640 / KS3660 Line recorder / Point recorder User s Manual

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Solution Selection Guide

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

dissolved oxygen transmitter

Capacitance Level Measurement Electronic insert FEC 12

DMP 331i / DMP 333i LMP 331 i

TempScan/1100 & MultiScan/1200

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Ambiflex MF620 USER GUIDE

Herzlich Willkommen Bienvenue Welcome. General Basics JUMO Screen Recorders. Manfred Schleicher

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Sample BD Tech Concepts LLC

ABB Instrumentation Operating Instructions Series Transmitters. Second Retransmission Output Supplement All Models.

FLOMAT Electromagnetic Insertion Flowmeter

C200H-AD002/DA002 Analog I/O Units Operation Guide

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

HSR-1 Digital Surveillance Recorder Preliminary

Henkel Installation Handbook LINEGUARD 2001

SCALE & WEIGHT DISPLAYS

263 Series LED Bargraph Indicator and Controllers

AF-300 E11 Adjustable Frequency Drive

Model KBF 115 Constant climate chambers with large temperature / humidity range

Click Here To Start Demo

K4P Series 4" Graphic Display Recorder from Barber-Colman

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

UNIT V 8051 Microcontroller based Systems Design

MTL Software. Overview

ELE C TRO MAG N E T I C FLO W M E T E RS

Sample BD Tech Concepts LLC

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Model KBF 1020 Constant climate chambers with large temperature / humidity range

SPACESCAN SERIES SS 02

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Manual. Simrad IS80 Wind Instrument WI80. English

CARLO GAVAZZI Automation Components

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Manual. Simrad IS80 Heading Repeater HR80. English

ex 800 Series ematrix System

Cooling systems for ORBIMAT

Single Axis Position Controller

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

SCREEN RECORDER KD8 TYPE

Assembly. Front view. LEDs. Parametrization interface. Power Bus

PSC300 Operation Manual

Defrost Control Installation and Programming of Version 3.1 Cards

TriLIN Program Utility TPU_ TriLIN Programming Manual

Dissolved Oxygen Transmitter

UNIIQA+ NBASE-T Monochrome CMOS LINE SCAN CAMERA

Digital Real Time Recording VCR

Model KBF P 240 Humidity test chambers with ICH-compliant light source

MICROPROCESSOR CALCULATION MODULE - S2000

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Transcription:

SP/CMDR13_3 Slide 1 COMMANDER SR100A & SR100B A1 100.0 C BOILER 6 TEMPERATURE

SP/CMDR13_3 Slide 2 A & SR100B Advanced print head design Bi-directional printing Rest position off page Continuous trace or separate dots Robust door and catch system IP65 / NEMA 3 Compact case design; 230mm (9in.) behind panel Universal inputs PC Configuration standard on all versions Basic and advanced versions Automatic Chart Rewind Technical Innovation

SP/CMDR13_3 Slide 3 Product Positioning SR100B Basic applications 3- or 6-channel versions Trace on paper Limited printing and scale formats Temperature/process recording market SR100A Advanced applications 1 to 6 channels available Detailed chart print out Data gathering Data storage on PC card Recording with sequence and math requirement

SP/CMDR13_3 Slide 4 Choice of Process Connections SR100B SR100A Analog Inputs 3 or 6 1 to 6 Transmitter PSU 3 loops standard 3 loops standard A nalog Outputs 12 optional Relays Digital Inputs 6 optional 12 optional 1 standard 1standard, 12 optional D igital Outputs 12 optional

SP/CMDR13_3 Slide 5 Operations

SP/CMDR13_3 Slide 6 Operations Universal 100mm Recorders High-clarity LCD display Two-line alpha-numeric and bargraph 2 x 20 character, long life, back-lit LCD Different display formats Eight display frames available Display in sequence Automatically or Manually A3 236.7 C BOILER 2 TEMPERATURE

SP/CMDR13_3 Slide 7 Operations Universal 100mm Recorders SR100 A Frame types Pen value (Multi-display) Digital values, including alarms Totalizer + PV Measured variable, channel no. Selectable lower frame line Bargraph Channel tag A3 236.7 C BOILER 2 TEMPERATURE SR100 B Frame types Fixed format Measured variable, channel no. Selectable lower frame line Channel tag

SP/CMDR13_3 Slide 8 Simple Operations Raise parameter value Lower parameter value Advance to next page or return to page header Advance to next parameter Lift/lower pen on alternate operation Store new value Raise and Lower Switches Sideways Scroll Switch Down Scroll Switch Pen Lift Switch Enter Switch

SP/CMDR13_3 Slide 9 Flexible and Accurate Up to 12 universal inputs Type B, E, J, K, N, R, S, & T Thermocouples, Pt100, ma, mv and V Programmable fault levels and actions Type B, E, J, K, N, R, S, & T Thermocouples, Pt100, ma, mv and V 2-wire transmitter power supply 70mA at 24V (3 loops) Accuracy ±0.1% Clear and accurate recording Power supply 85 to 265V ac 10 to 30V dc 24V ac +

SP/CMDR13_3 Slide 10 Chart Trace One digital input as standard Change chart speed, stop chart or alarm acknowledge Digital filter reduces the effect of noise Two configurable pen functions Chart trace trend of analog inputs or math results 3-position event marker (In, Off or Out) 6 programmable zones for event marking SR100A only A Zones 1 2 3 4 5 6 B Zones 1 to 6 each 16.6mm wide. Events A and B represented by a 3mm shift from the centre line.

SP/CMDR13_3 Slide 11 Printed dots overlap giving a continuous, unbroken trace at chart speeds up to 500 mm/hr Message printing overlaps continuous traces at chart speeds of up to 120mm/hr At chart speeds of 120mm/hr and above, the trace is broken for text If new dot is more than a dot s width from the last postion, the pen is dropped and dragged to produce a trace Chart

SP/CMDR13_3 Slide 12 Roll or fanfold chart Flexibility of customer choice 25m (82ft) Roll Chart, 12m (39ft) Fanfold Chart Automatic chart rewind Simplifies chart changing Quick-fit pen cartridge Changed in seconds Removable chart cassette For easy chart replacement Instrument ranges the chart Standard chart used, recorder adds ranges and scales to suit the application Easy to Use

SP/CMDR13_3 Slide 13 Tough and Rugged Stainless steel case Hard wearing, corrosion resistant Chemically-resistant polycarbonate door High security Optional door lock IP65 / NEMA 3 front facia Ideal for harsh environments, outdoors or indoors

SP/CMDR13_3 Slide 14 Features

SP/CMDR13_3 Slide 15 B Power without Complexity 3- or 6-point recorder for basic pen-on-paper applications Configuration Chart annotation as standard makes chart record clear time, date, chart speed, channel scales and alarm indication Can be supplied preconfigured and ready to run

SP/CMDR13_3 Slide 16 B Analog Block Diagram Inputs 6 Analog Inputs Print or Display Draw 6 Traces Display all Analog Inputs (Scroll)

SP/CMDR13_3 Slide 17 B Digital Block Diagram Analog Inputs Inputs 12 Process Alarms Outputs 6 Relays 1 Standard Digital Input Chart Speeds 6 Input Failures Global Acknowledgement Line Failure Scale Print Chart Speed Status Paper Out

SP/CMDR13_3 Slide 18 B Keep control of your process 12 Alarms available High/Low process alarms with hysteresis Can be allocated to relays or print alarm on chart Up to 6 relays can be fitted Rated 5A 230V

SP/CMDR13_3 Slide 19 B Chart Text End of Chart Warning last 2m (roll chart) or 1.5m (fanfold) Channel Tag every 240 mm Time, Date & Chart Speed power-up and every 240 mm Tank Flow 12:00 24 NOV 98 120mm/h Time Date Chart Speed

SP/CMDR13_3 Slide 20 B Chart Text Time nearest hour or half hour after 60mm of trace 10:00 Chart Scale 6 different scales; printed every 10mm to 240mm (programmable) 0 20 40 60

SP/CMDR13_3 Slide 21 B Chart Text Change of Chart Speed 9:55 300mm/h Process Alarms (Pa) 09:46 PaA Time of Alarm Alarm Type/ Identifier

SP/CMDR13_3 Slide 22 B Chart Text Trace Identifiers A1 A2 A3 A4 A5

SP/CMDR13_3 Slide 23 A 1- to 6-point recorder Advanced strip chart recorder Simplicity with Power 5 Display configurations PV + Units + Bargraph; PV + Units + Channel Tag; PV + Units + Totalizer; Digital Signals; Multiple PV s + Units A1 100.0 C BOILER 6 TEMPERATURE Unique Cue & Review Historical analysis of data while the chart is still in the recorder Buffering of last ten alarms Full chart annotation Alarm messages, batch number, totalizer print, value print, time, date, chart speed

SP/CMDR13_3 Slide 24 A Analog Block Diagram Inputs Functions Print or Display Outputs Draw 6 Traces 6 Analog Inputs Print 12 Analog Values 6 Analog Inputs (Optional) 4 Math Blocks Display 2 Blocks of 8 Inputs (Auto-scroll) Display all Analog Inputs (Manual-scroll) Modbus (RTU) Serial Communications PCMCIA Memory Card up to 12 Channels Print and/or Display 6 Totalizers 12 Analog Outputs

SP/CMDR13_3 Slide 25 A Digital Block Diagram Input Sources Functions Outputs Analog Inputs 12 Process Alarms 12 Relays 2 Real Time Events 6/12 Input Failures 10 Logic Equations 12 Digital Outputs 6 3-Position Event Pens Line Failure Global Acknowledgement Chart Speed Status Totalizers Resets/ Stop and Start Paper Out Chart Speeds 12 Digital Inputs 1 Standard Digital Input Printing 1 Operator Message 14 Digitally-triggered Message 12 Alarm Messages 2 Real Time Alarm Messages 12 Channel Values 12 Channel Data 6 Scales 6 Totalizers

SP/CMDR13_3 Slide 26 A Interface with your process Configuration flexibility with internal soft-wiring allocation of alarms internally without hard wiring 12 Alarms as standard soft-wired to relays or logic equations Up to 12 relays for sequential process requirements Rated 5A Up to 13 digital inputs Soft-wired to logic equations, message print or chart control 5V TTL or Volt-free I O Alarm

SP/CMDR13_3 Slide 27 A Processing power 4 math blocks Add, Subtract, Multiply, Divide, RH, Mass Flow, Low High and Median Select 6 Flow totalizers 10 logic equations Input from alarms or digital inputs AND and OR 2 real-time event timers 1 x 20-breakpoint linearizer Ideal for non-linear tanks or special thermocouples

SP/CMDR13_3 Slide 28 A Flexibility of Interfaces RS485 Modbus RTU Available as an option for communication with control systems 2- or 4-wire connections 12 analog retransmission outputs Can be allocated to input signals or result of math blocks

SP/CMDR13_3 Slide 29 A Memory Card... DOS-formatted for direct viewing on spreadsheet Recording of up to 12 channels Recording of process alarm states Date and time stamped Channel tags and units for each channel

SP/CMDR13_3 Slide 30 A Memory Card PCMCIA memory card Configuration storage Data logging for simple interfacing with your PC Open System transfer to MS Excel & Lotus 123 spreadsheets Data logging 640kb, 1Mb, 2Mb & 4Mb card capacities Memory card logging capacity dependent on memory card size and scan time Scan rates from 1 to 240 seconds Card Size 64k 63,488 Usable Bytes 128k 129,024 256k 260,096 512k 521,216 1M 1,045,504 2M 2,092,032 4M 4,186,112 Card Running Time (hrs) = scan interval (secs) x useable bytes hrs (13 + [No. of channels x 7]) x 3600 Where: Scan interval = 1 to 240 seconds Usable bytes = number of bytes usable for data logging see Table No. of channels = 1 to 12

SP/CMDR13_3 Slide 31 A Chart Text... End of Chart Warning last 2m (roll chart) or 1.5m (fanfold) Channel Tag every 240mm Time, Date & Chart Speed power-up and every 240mm Tank Flow 12:00 24 NOV 98 120mm/h Time Date Chart Speed 0 20 40 60 Chart Scale 6 different scales; printed every 10mm to 240mm (programmable)

SP/CMDR13_3 Slide 32 A Chart Text... Totalizer Values Printed at intervals between 5 and 720min; from a digital signal or from within the Print Messages Page 11:00 T2 000035.19 m3 Tank Time Totalizer Identifier Flow Total Flow Units Totalizer Tag Time nearest hour or half hour every 60mm of trace Channel Data engineering range and units, printed on demand from a digital signal or from within the Print Messages Page 10:00 A1 0.0 / 100.0 l/h A2 0.0 / 14.0 ph A3 0.0 / 250.0 C A4 0.0 / 20.0 CO2 A5 0.0 / 100.0 %RH A6 0.0 / 500.0 m3/day Channel Number Range Units

SP/CMDR13_3 Slide 33 A Chart Text... Change of Chart Speed Operator Message printed from a digital signal or from within the Print Messages Page Process Alarms (Pa) or Real Time Alarms (Rt) printed in red if an alarm condition occurs. Any message assigned to the alarm is also printed 9:55 300mm/h 09:50 Batch 18/3 Complete 09:46 Rt1 Cleaning Complete 09:46 PaA High Inlet Temp Time of Alarm Alarm Type/ Identifier Message Assigned to Alarm

SP/CMDR13_3 Slide 34 A Chart Text... Channel Values Printed at programmable time intervals (between 5 and 720 minutes), on demand from a digital signal or from within the Print Messages Page 09:00 A1 75.5 %RH A2 495.8 m3/day 09:00 A3 110.0 C A4 20.0 CO2 09:00 A5 25.2 l/h A6 7.0 ph Time Channel Number Measured Value Units Channel Number Measured Value Units

SP/CMDR13_3 Slide 35 A Chart Text Trace Identifiers Event Marker Identified with either: '<' input A active, pen in '>' input B active, pen out A1 A2 A3 A4 A5 20 Character Message Block up to 14 different messages can be printed on demand from a digital signal 08:00 Start Cleaning Cycle

SP/CMDR13_3 Slide 36 PC Configuration with MS Windows Create configurations in minutes Save onto disk or memory card Print out hard copy Download to recorder All recorders have dedicated configuration ports Compatible with MS Windows 3.1, 95, 98 & NT

SP/CMDR13_3 Slide 37 Application Features

SP/CMDR13_3 Slide 38 Easy View Instant view of the latest trace and process conditions A1 100.8 C BOILER 1 TEMPERATURE A1 100.8 C BOILER 1 TEMPERATURE Chart Advance Chart traces during normal operation (in Operating Page 1 or 2) 1 Operate the switch to 2 activate Easy View The chart advances approximately 30mm for 5 seconds and then rewinds to its original position and resumes recording

SP/CMDR13_3 Slide 39 A Cue & View Post-incident and historic data review Last 10 process or real-time alarms buffered and available for review Advance/rewind facility Review long term and monitored data A3 236.7 C 25m

SP/CMDR13_3 Slide 40 A Message Block Configuration 14 message blocks 20 Characters Colour Selectable Time Stamped Block Print Sources Total wrap Paper out alarm Input failure Digital input Chart speed Logic equation Power failure Real time alarm Process alarms Message Blocks 9:20 End Cleaning Cycle Trace 9:00 Start Cleaning Cycle

SP/CMDR13_3 Slide 41 A Print Channel and Data Values Printing of up to 12 channel values Channel identity, value and engineering units for each channel Channel Values Selectable printing trigger Internal Digitals (Alarms) External Digitals (Inputs) Time Intervals (0 to 24 hours) Channel Data 11:44 A1 196 C A2 206 C 11:44 A3 126 C A4 157 C 11:44 B1 104 C B2 214 C 11:44 B3 124 C B4 112 C 11:44 B5 226 C B6 108 C A1 0 / 1000 C A2 0/250 Gal/hr A3 0/ 500 Liters A4 0/100 Pints Time Channel Number Measured Value Channel Number Measured Value Channel Number Range Units

SP/CMDR13_3 Slide 42 A Print Totalizer Values Printing Channel identity, value and engineering units for each channel Selectable printing trigger Internal Digitals (Alarms) External Digitals (Inputs) Time Intervals (5 minutes to 24 hours) 11:28 T1 10903333 LITRES Flow 1 11:28 T2 22702221 GALS Flow 2 11:28 T3 30004434 m3 Flow 3 11:28 T4 44950394 LITRES Flow 4 11:28 T5 59573487 GALS Flow 5 Time Totalizer Identity Value Totalizer Units Totalizer Tag

SP/CMDR13_3 Slide 43 A Math Blocks 4 Programmable math blocks 11 Standard math functions RH Mass Flow 1 & 2 (a x b) + c (a b)/c (a + b)/c (a x b) x c (a + b + c)/3 (a + b + c) Low Select Med Select High Select F Value Programmable engineering units and result tag for each block + x

SP/CMDR13_3 Slide 44 A Math Block Example Total Flow Calculation Individual flow signals from the flowmeters in each pipe are recorded on separate channels The total flow rate (in the common pipe) is calculated using a math block Internal soft wiring is used to record the total flow rate on a fourth channel Use the math result as an input to a totalizer to calculate the total flow quantities and hence the volume of liquid

SP/CMDR13_3 Slide 45 A 10 programmable logic (Boolean) equations Up to 16 elements per equation Integration of both internal and external signals Alarms Digital inputs Other logic equations Real time alarms Initiation of instrument functions Alarm acknowledgement Pen events Changes of chart speed Value printing Relay outputs Logic Equations...

SP/CMDR13_3 Slide 46 A Logic Equations 14 Different operands available: * Terminator, used to complete the expression ) Close bracket ( Open bracket & Logical AND + Logical OR T1W T6W Wrap-around of totalizer (T1 to T6) P_O Paper Out alarm FA1 FB6 Input failure (A1 to A6, B1 to B6) DA1 DG3 Digital input active CS1 CS3 Chart speeds L1 L10 Logic equation true PWR Power failure RT1 RT2 Real time alarm on (1 or 2) PAA PAM Predefined process alarm (A to M excluding I)

SP/CMDR13_3 Slide 47 A Logic Equation Example Pump On/Off Control Auto Manual Override FT Configuration Analog Inputs Pump LT Pump Running Conditions Low Level AND time is between 8:00am and 5:00pm AND no manual override Input Elements Alarm A (PAA) set to Low Process Alarm with a trip of 1.8m and hysteresis of 0.2m Real-time Alarm 1 (RT1) set on at 8:00am until 5:00pm Digital input (DA1) set for positive logic so that when the switch is in Auto (normal operation) the input is active Logic Equation EQ01 = PAA & RT1 & DA1

SP/CMDR13_3 Slide 48 A Logic Equation Example Pump Control with Low Low Cutoff Auto Manual Override Configuration Analog Inputs Pump LT Operation as for previous Pump On/Off Control example, except that additional safety is now provided by a Low-Low Alarm Alarm B set for Low-Low Process Alarm with a trip level of 1.4m Relay assigned to Logic Equation 2 Logic Equations EQ01 = PAA & RT1 & DA1 EQ02 = EQ01 or PAB FT

SP/CMDR13_3 Slide 49 A Logic Equation Example Sequence Control Logic equations provide safety interlocks to prevent plant from being operated manually when certain process conditions are true A chart recorder is monitoring dosing flows into a mixing tank The chemicals in stream C must not be dosed at the same time as the chemicals in streams A and B A relay is therefore required which prevents valve C from opening if valves A (DA1) or B (DB1) are open Logic Equation: EQ01 = DA1 or DB1 Relay = EQ1 A B C

SP/CMDR13_3 Slide 50 A Custom Linearizer Y Single 20-point custom linearizer Variable spacing on X and Y axis to allow optimization of breakpoints Yn 100% % Linear Output Select up to twenty breakpoints to create the curve required Y5 Y3 Y4 Y2 Y1 0 X1 X2 X3 X5 X4 where n = breakpoint 2 to 20 100% Xn X % Non-Linear Input

SP/CMDR13_3 Slide 51 A Real-time Alarms 2 programmable real-time events Programmable start and end dates/ times Times are selectable for hour, day, month, year or a combination of any of these

SP/CMDR13_3 Slide 52 A Real-time Alarm Example print out a daily total and reset Real Time Alarm 1 (RTA1) set as follows: ON time OFF time ** Year ** *** Month *** ** Day ** 00 Hour 00 00 Minutes 01 Assign Total 1 Print Source and Total 1 Reset Source to RTA1 ON OFF 1minute on time 22:00 23:00 00:00 01:00 02:00

SP/CMDR13_3 Slide 53 A Real-time Alarm Example using two totalizers to log day and night flows Set RTA1 as follows: Set RTA2 as follows: ON time OFF time ON time OFF time ** Year ** ** Year ** *** Month *** *** Month *** ** Day ** ** Day ** 06 Hour 18 18 Hour 06 00 Minutes 00 00 Minutes 00 Assign Total 1 Stop/Go Source to RTA1 for total daytime flow and Total 1 Print Source to RTA2 Assign Total 2 Stop/Go Source to RTA2 for total night time flow and Total 2 Print Source to RTA1 RTA1 ON is used to print the night flow total and RTA2 ON the day flow total

SP/CMDR13_3 Slide 54 A Totalizer Functions... Six digital totalizers available assignable to any channel or math results Count up or down Count Pulse Used to energize relays or digital outputs Wrap Pulse Used to energize relays or digital outputs

SP/CMDR13_3 Slide 55 A Totalizer Functions Programmable present and predetermined count values for batch totals Adjustable cut-off values Operator level reset and stop/go Digital signal reset and stop/go

SP/CMDR13_3 Slide 56 A Message Printing Start Cheesecake (Digital Input DB1) DB2 High = 'Print Message 2' 10:04 Meringue Start Batch Complete (Digital Input DB3) Start Meringue (Digital Input DB2) DB3 High = Print Message 3 and channel values Alarm A active = Print Message 4 DB1 high = Print Message 1 DB1 OR DB2 high = Print scales Print 'blank' Operator Message to give date and time 10:01 Batch Complete 10:01 A1 192 C A2 51 C 09:55 Oven temp high 09:15 Cheesecake Start 60 80 100 09:00 11-NOV-99

SP/CMDR13_3 Slide 57 A Deviation Alarms Ch 1 Ch 2 Ch 3 = Ch 1 Ch 2 Differential of two process variables can be recorded as a single channel Maths blocks used to calculate differential alarm from and/or record this value Channel 1 Process variable input Channel 2 Reference value (Used to measure the deviation) Channel 3 The resultant deviation

SP/CMDR13_3 Slide 58 A Average Value Printout 150 C Full scale value Printout of a signal averaged over a set period Achieved by using combination of real-time alarms and totalizer 100 C 75 C 50 C 25 C 0 C 0h00 Instantaneous value 0h30 Average value Averaging period ( = 3600s) time 1h 0 25 50 75 10 12:00 T1 0000050.0 Av Temp

SP/CMDR13_3 Slide 59 F Value... Four independant F Value calculations for sterilizing cycle applications User configurable variables Internal and external digital start and end calculation signals Sample time of 720ms resulting in an accuracy of <2% C 140 120 100 80 60 40 20 A BCD E F Time (minutes)

SP/CMDR13_3 Slide 60 F Value (T o T t ) Fvalue(t) = Fvalue(t 1) + (10 Z ) 60 ( ) sample rate Where: Fvalue(t) = current Fvalue sum Fvalue(t 1) = Fvalue sum at last sample T o = measured temperature T t = target sterilizing temperature Z = temperature interval representing a factor of 10 reduction in killing efficiency (Z factor) Sample Rate = 0.48 seconds

SP/CMDR13_3 Slide 61 Remote Chart Speed Selection Where continuous recording of measured variables is not required, a digital input can be used to switch recording on and off or change chart speed Set Up: Connect a normally open volt-free signal to a digital input on the recorder Set chart speed 1 to 0mm/hr; chart speed 2 to the speed required. Allocate chart speed 2 source to the appropriate digital input; chart speed 1 source to Chart Speed 2. When more than one chart speed source is active, the higher numbered source gets priority I O or Switch closed (chart running) Switch opened (chart stopped) Switch closed (chart running) Switch opened (chart stopped) Switch closed (chart running)

SP/CMDR13_3 Slide 62 Application Examples

SP/CMDR13_3 Slide 63 A & B Effluent Flow Monitoring and recording of Flow, ph and Temperature 4630 ph Transmitter Wash Water Tank A1 100.0 C BOILER 6 TEMPERATURE ph Electrode Pump D (peristaltic) Pump C (effluent) Holding Jar Valve A (wash) Treated Effluent In Overflow/Return Sample Collecting Jar Valve B (effluent sample) Treated Effluent Out Magmaster Flowmeter Holding Tank

SP/CMDR13_3 Slide 64 A & B Package Boilers Multiple process point monitoring including: Oxygen Temperature Level Flows A1 100.0 C BOILER 6 TEMPERATURE Third Pass Second Pass First Pass 3-Pass Boiler

SP/CMDR13_3 Slide 65 Sterilizer Validation and Periodic Tests Thermometric tests to monitor and record temperature and pressure readings

SP/CMDR13_3 Slide 66 Monitoring and Recording of Temperature and Level Tank Farms A1 100.0 C BOILER 6 TEMPERATURE

SP/CMDR13_3 Slide 67 Monitoring and Recording of Gas and Temperature: CO O 2 NO CO 2 Kiln Waste Gases ZFG2 O 2 probe (0.4 or 1m) Pre-heater (CO) Dopol (CO 2,O 2 ) Stack Kiln feed (NO, CO 2, O 2, CO) Bypass Rotary kiln A1 100.0 C BOILER 6 TEMPERATURE Electrostatic precipitator

SP/CMDR13_3 Slide 68 Batch Monitoring of Temperature and Pressure Autoclaves/Retorts Pressure Control Valve Current to Pressure Converter Pressure Transmitter RTD Temperature Sensor Current to Pressure Converter Steam Steam Control Valve Drain Solenoid Valve

SP/CMDR13_3 Slide 69 Clean in Place Monitoring and recording of caustic solutions temperature and flow Caustic make-up solution 4621 Analyzer 4621 Analyzer A1 100.0 C BOILER 6 TEMPERATURE Level Control 9307 2221 Cell Changeover valve (out to effluent plant) 2271 Cell Return from cleaned pipes and vessels To pipes and vessels to be cleaned Pump Mains (make-up) water in Mains water (flushing) Caustic bulk tank

SP/CMDR13_3 Slide 70 Cold Storage Multizone/room temperature monitoring and recording Temperature Sensors (individual cable runs to the SR100 Recorder to ensure accuracy and profile of store ) Temperaure Sensor Connections Racking and Storage Pallets Loading and Unloading Bay A1 100.0 C BOILER 6 TEMPERATURE Frozen Food Store (not drawn to scale as stores may be very large e.g. 10,000m 2 and larger

SP/CMDR13_3 Slide 71 Monitoring and recording of multiple zones temperature and moisture Tobacco Leaf Processing A1 100.0 C BOILER 6 TEMPERATURE

SP/CMDR13_3 Slide 72 Summary SR100B Basic applications 3- or 6-channel versions Trace on paper Limited printing and scale formats Temperature/process recording market SR100A Advanced applications 1 to 6 channels available Detailed chart print out Data gathering Data storage on PC card Recording with sequence and math requirement