Hall 1 Technical Information

Similar documents
The Lantern Technical Information

Technical Information

DEREHAM MEMORIAL HALL

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

New Theatre Royal Lincoln Technical Information

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Main House Technical Specification

Technical Specification Pavilion Dance

BRAMALL INTRODUCING THE. Venue hire for classical & pop music, spoken word & comedy

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

ISLAND HALL TECHNICAL INFORMATION

Technical Specification

Technical Specification

Technical Specification

INFORMATION FOR VISITING COMPANIES

HIRE AND TECHNICAL INFORMATION

UNIVERSITY CONCERT HALL. Technical Specification

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Tickets will be sold through our ABC account and all tickets are scannable on entry.

TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

Technical requirements & conditions for hirers

CENTRE FOR PERFORMING ARTS

Technical Specification for the Alley Theatre, Strabane

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

Arcadia Performing Arts Center Technical Specifications and Information

Pleasance London Main House Visiting Company Information Pack May 2017

Dr JOHN GALLAGHER CONCERT CHAMBER

Sandusky State Theatre Technical Specifications

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Technical Services and Specification

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Darlington Hippodrome Technical Specification

2017 TECHNICAL SPECIFICATIONS

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Access to back stage is off Fletcher St on the eastern side of the building

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Technical Pack. Attenborough Arts Centre

Technical Specifications

Main House Technical Specifications

Centre Stage and City Room at Surrey City Hall Venue Information

Information for Incoming Companies

TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE

Technical Specification

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Technical Specification Ardhowen Theatre

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Ed Blackwell Production Manager Mike Weller Head of Music

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Facility Information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

The Lights Technical Guide June 2017

Matt Dann Cultural Centre

Theatre Technical Specifications

Rhodes Arts Complex Bishops Stortford. Technical Specifications

TECHNICAL REQUIREMENTS

MONASH University Academy of Performing Arts

ROSE THEATRE BASEMENT

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Specifications and Inventory Spring 2018

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

The Breen Center for the Performing Arts Saint Ignatius High School

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Technical Director of Production Andrew Quick Ext 252

John Leslie Theatre. Technical Specifications. Updated July 2018

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

Technical Specifications Updated 01/10/2017. Stage

Latrobe Performing Arts Centre

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Information

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Please note we do have some regular volunteer technicians but there is no full time technical manager.

Technical specifications Main theatre. Sound

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

THE STREET THEATRE. Technical Specifications

Lighthouse Theatre Technical Specification

Concert Hall Technical Specifications

Technical Specifications

The Anvil Technical Specifications

HUECO / Technical Rider

Hard Rock Cafe Times Square Sound System Advance Sheet

Technical Information

THEATRE ROYAL MARGATE Technical Specification April 2018

Powerhouse Theatre technical information and general specifications 2017

TECHNICAL SPECIFICATION

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

Arlington Arts Tech Spec 2018

A Technical Guide to the Faith Center

THEATRE ROYAL MARGATE Technical Specification January 2016

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Transcription:

Hall 1 Technical Information Last updated February 2017 Page 1

CONTENTS AUDITORIUM... 3 CAPACITY... 3 WHEELCHAIR POSITIONS... 3 STAGE... 3 DIMENSIONS... 3 STAGE EXTENSION... 4 STEPS INTO THE AUDITORIUM... 4 MIXER POSITION... 4 TABS & DRAPERY... 4 PIANOS... 4 ORGAN... 4 POWER... 4 FLYING FACILITIES... 5 LIGHTING... 5 GENERIC LIGHTING... 5 INTELLIGENT LIGHTING... 5 CONTROL... 5 DIMMING... 5 FOLLOWSPOTS... 5 HAZE & EFFECTS... 5 SOUND... 6 FOH PA... 6 MIXER & OUTBOARD... 6 MICROPHONES & DI BOXES... 6 BACKSTAGE... 7 DRESSING ROOMS... 7 SHOWERS... 7 TOWELS... 7 LAUNDRY... 7 KITCHEN & CATERING... 7 INTERNET AND WIFI... 7 PARKING... 7 UNLOADING... 8 PROGRAMMES & MERCHANDISE... 8 STAFFING... 8 SECURITY... 8 HEALTH & SAFETY... 8 DIRECTIONS... 9 STAGE PLAN... 10 Page 2

An interactive guide of Colston Hall is available to view at: http://www.jondavey.com/panoramas/colstonhall/output/index.php AUDITORIUM Hall 1 can be configured in several formats depending on the requirements of your event. The front stalls level can be used in fully seated, cabaret or standing formats. CAPACITY Please note these figures are gross capacity and do not allow for sightline, technical or house holds. Total Stalls Balcony Choir Seats/boxes Seated pop/rock concerts 1834 1002 832 N/A Classical concerts 2069 1002 832 235 Part Standing* 1932 1100 832 N/A *Rows A R can be removed for part standing concerts. In this format the stalls is sold as a general admission area (no reserved seats). Please note that this configuration entails additional charges to cover the costs of seating removal, barrier and extra security staff. WHEELCHAIR POSITIONS Areas of the hall have been set aside to allow patrons who are confined to wheelchairs access to concerts. Positions in the stalls and balcony are available. STAGE The stage is a concert platform and therefore does not have a proscenium arch. The stage surface is polished wood and therefore there is limited facility to drill, screw or nail items through the stage surface. All gaffa, double-sided and hazard tapes are to be removed from the stage surface prior to the end of tenancy. Any damage to the surface will result in a charge being made to the visiting company. Please be aware that the front edge of the stage is curved and therefore is deeper in the centre than at the edges. DIMENSIONS Depth (Centre Stage) 6.5m 21 3 Depth (Stage Left and Stage Right) 5.5m 18 3 Width 14.8m 48 0 Height 9.1m 30 0 Downstage Edge to Mixer Position 9.1m 30 0 Recommended FOH multicore length 50m 164 Mixer Position 4.8m x 2.7m 16 x 9 PA wings 2.1m x 1.7m 6 10 x 5 6 Page 3

STAGE EXTENSION (additional charge) A stage extension is available for Hall 1. It will extend the stage by 1.2m in the centre. It flattens the curve at the front of the stage so the edges of the stage are even further extended. Using the stage extension will reduce the capacity of the auditorium by around 100 people and will be charged for as a contra on top of the hire fee. STEPS INTO THE AUDITORIUM There are steps from the stage into the auditorium DSL and DSR. Please be aware that the PA wings will cover these steps if they are used. Alternative centre steps are available but will reduce capacity by 6 seats. Please advise us asap if you require steps into the auditorium. MIXER POSITION The authorised space is rows OPRS 17-25, 4 x 9 seats. A second position can be arranged across the gangway (OPRS 8-16). Due to the relatively flat rake of the stalls auditorium, seats (TU 17-20) are also held off sale behind the mixer positions to allow for tall outboard racks or standing engineers. TABS & DRAPERY These drapes are hung from the upstage chord of the upstage truss to hide the choir seats when required. 4x Black Wool Surge Drapes 9.1m x 4.45m 30 x 15 1x Black Wool Surge Drape 7.6m x 3m 25 x 10 Colston Hall has no borders or legs. PIANOS (additional charge) Both Steinway Pianos at Colston Hall are tuned to A=440 as standard. Alternative tuning is available. 1. Steinway D Manufactured 1987 Only to be used for concerto performances 2. Steinway D Manufactured 1960 ORGAN (additional charge) Information about the organ at Colston Hall can be found at http://www.bdoa.org.uk/index.php?option=com_content&view=article&id=160:colston-hall-bristol POWER Please note that all stage power is situated Upstage Right. LIGHTING 1x 400amp 3 phase Powerlock or 125a 3 phase ceeform. SOUND 100amp three phase supplying: 1x 63a 3phase/ceeform 1x 32a 3phase/ceeform 1x 63a 1phase/ceeform 1x 32a 1phase/ceeform TOUR BUSES (additional charge) Located on Colston Street only 2x 16a 1phase/ceeform Page 4

FLYING FACILITIES Visiting companies may only suspend equipment and motors from the three house trusses. There are no other load bearing points in the roof space. All trusses are standard GP20 box truss Downstage/FOH Truss (3 tonne UDL) 14m 45 11 Midstage Truss (3 tonne UDL) 15m 49 3 Upstage Truss (2 tonne UDL 9m 29 6 LIGHTING (additional charge) Please be aware that certain lighting requirements may incur additional charges. Please consult your Colston Hall contact for details. OVERHEAD ORCHESTRAL LIGHTING (no charge) Please note that the orchestral lighting is situated in the canopy and therefore cannot be focussed or coloured. 41x Par64 (CP62) Open White Only GENERIC LIGHTING 40x Par 64 (CP62) 12x Source Four 19 INTELLIGENT LIGHTING 4x Martin Mac Quantum Profiles LED LIGHTING 10x Miltec Par Can 144 RGBW LED Floor can CONTROL 1x Chamsys Magic Q MQ60 DIMMING 48 channels of 10amp dimmers on 15 amp sockets. Please note there is no dimmable power on the midstage truss. Upstage Truss 18 channels Downstage/FOH Truss 18 channels Side Balcony Perch s 4 channels (paired across the stage) Stage Left onstage Dips 4 channels Stage Right onstage Dips 4 channels FOLLOWSPOTS (additional charge) The standard position is side balcony. Additional followspots may be situated further back to give a more central throw, but will reduce capacity. Operators available upon request. 2x Robert Julliet Foxie 700w Touring spots can be placed in wheelchair positions. Power is on 15a or 13a. Please arrange in advance to ensure spaces are held off sale. HAZE & EFFECTS 1x LeMaitre Neutron Pro Hazer (Non DMX) 1x Smoke Factory Tour Hazer II Page 5

SOUND (additional charge) Please note there is an additional charge for use of the sound equipment. Ancillary equipment such as desks, monitors and microphones are shared between all spaces at Colston Hall. Please contact the technical department with your requirements to ensure availability of equipment. The sound system in Hall 1 features a Nexo S12 flown line array, Nexo PS10 s and PS8 s. Please note the system does not have any subs, but is more than adequate for vocal reinforcement and light music events. FOH PA Stalls 2x S1230 (from central hung line array) 2x S1210 (L&R) Front Fills 4x PS8 Balcony 4x S1210 (from central hung line array) 2x PS10 (Mono) Rear Stalls Delay 10x Small delay speakers Nexo Nexo Nexo Nexo Nexo QSC MIXER & OUTBOARD 1x X32 Compact Mixer Behringer 1x MG32/14FX Mixer Yamaha 2x CD Players Tascam MICROPHONES & DI BOXES 13 x SM58 Shure 2 x Beta 58A Shure 4 x SM57 Shure 4 x Beta 57 Shure 1 x Beta 91A Shure 1 x Beta 52A Shure 1 x Beta 87 Shure 2 x KSM 137 Shure 5 x E604 Sennheiser 1 x E906 Sennheiser 4 x M201 Beyer 1 x RE20 Electro-Voice 1 x D112 AKG 2 x C451B AKG 4 x C1000 AKG 2 x C451 AKG 1 x D321 AKG 1 x TPS3700 AKG 2x 2011 DPA 2x 4011 DPA 4x 4099 (rock clip set) DPA 2 x PG58 Handheld Radio Mics Shure 10x Mono Active DI s Behringer 2x Pro AV2 Stereo DIs Radial Page 6

BACKSTAGE DRESSING ROOMS All dressing rooms have a couch, hanging space, a full length mirror, vanity mirrors and wifi. Capacity Dimensions Additional facilities Dressing Room 1 6 People 3.7m x 3.6m Toilet, fridge, coffee table Dressing Room 2 4 People 2.5m x 3.7m Dressing Room 3 6 People 2.5m x 3.7m Dressing Room 4 4 People 1.9m x 3.5m Telephone (0117 927 9592) Dressing Room 5 10 People 3.3m x 3.5m Telephone (0117 927 9592 Dressing Room 6 6 People 2.5m x 3.7m Toilet, fridge Ladies Changing Room 15 People 3.0m x 4.8m Adjoining room (2.9m x 3.5m) Gents Changing Room 10 People 3.1m x 4.5m Green Room 96 People 15.7m x 8.1m Tables & chairs for 96 people SHOWERS A shower room for use by the Artiste is situated in the dressing room area. Another 2 wet rooms for crew members are situated in the changing rooms off the Green Room. TOWELS (additional charge) White bath towels can be hired. Please note Colston Hall does not have stage/hand towels. LAUNDRY Please note Colston Hall does not have any in-house laundry facilities. The nearest laundrette is Staffords, 1-3 Cotham Rd S, Bristol BS6 5TZ. Irons and ironing boards are available upon request. KITCHEN & CATERING Touring Kitchen Hot/Cold Water Fridges 2x 32a single phase power Numerous 13amp supplies Backstage and front of house catering can be provided in-house. Please contact Claire Weston, operations co-ordinator for further information INTERNET AND WIFI Colston Hall has an open wifi network covering most spaces including the dressing rooms, stage and public areas. There are also 2x 100mb Cat 5 lines situated Upstage Left and 1x 100mb Cat 5 line Upstage Right. PARKING (additional charge) Colston Hall has no free parking facilities. Parking meters at the front and rear of the Hall can be suspended by prior arrangement for unloading and crew coaches. A mains landline can be provided for coaches at the front of the building. Vehicles parked on these bays must display an authorised pass to prevent towing away. Additional parking can be arranged through our operations co-ordinator. Please contact Claire Weston for details. Trenchard Street multi-storey car park is situated at the rear of the Hall. Page 7

UNLOADING Equipment may be unloaded at the Trenchard Street entrance, at stalls level. Access on to the stage is by ramp from the auditorium. Loading in and out requires a 20 metre push along a narrow corridor which has two tight turns. The smallest opening to negotiate is 1.5m x 1.95m (4 11 x 6 4 ). Please remember that Trenchard Street is near a residential area and keep noise to a minimum during your get-out. PROGRAMMES & MERCHANDISE (additional charge) Programme sellers can be provided. Please contact our House Manager for our merchandise facility fee charges. STAFFING One member of technical staff is provided as standard for events in Hall 1. If you require humpers please contact Help n Hands on 07802 870115. SECURITY (additional charge) Security Staff are rostered at the House Manager s discretion, please contact the House Manager for further information and a quotation. Operations staff: General Manager Nick Craney 0117 204 7042 Technical Services Manager Andy Collins 0117 204 7102 Technician Jon Fox, Frazer Riches & Colin Pegum 0117 204 7102 House Manager Daniel Wood 0117 204 7038 Technical Services Co-ordinator Claire Weston 0117 204 7043 Email: firstname.surname@colstonhall.org HEALTH & SAFETY Please note that ALL materials used on the stage MUST be fully fire-proofed. All electrical equipment brought into Colston Hall must have a valid certificate of portable appliance testing (PAT). Colston Hall management reserve the right to refuse permission for event organisers to use any equipment if a valid certificate cannot be produced. A PAT testing service is available in house, please enquire for details. Colston Hall requires Risk Assessments and Method Statements from all visiting companies. All events must be set up by competent persons. Please ensure that all details are sent to the Operations Coordinator at least 2 weeks prior to an event. Failure to do this may mean that an event will not be permitted to proceed but the event will still be charged. Page 8

DIRECTIONS ADDRESS Colston Hall Colston Street Bristol BS1 5AR BY TRAIN Temple Meads, the nearest station, is about one mile from Colston Hall. Buses 8 and 9 run directly run directly to the city centre promenade. For further info about train times please call National Rail Enquiries on 08457 48 59 50 (24 hrs) BY BUS Most buses to the city centre stop at the promenade, where we recommend you alight for Colston Hall. We are situated on Colston Street, behind Colston Tower. For further bus enquiries please call First Cityline on 0845 602 0156 (8am-8pm) Night-Flyers run every Friday and Saturday night 12 6am every hour on the hour at a flat fare of 2.50 from various points in the centre. For further information please call 0117 922 4454, email public.transport@bristol.gov.uk or visit the Bristol City Council website. BY CAR Via M5: Exit junction 18, follow A4 (Portway) to the centre. At the promenade (St Augustine s Parade) turn left into Colston Street. Via M4: Exit junction 19 (M32). Follow signs to Clifton. For dropping-off / picking-up turn into Colston Street, which is the first left after the Bristol Royal Infirmary (BRI). Look out for the brown signs directing you to Colston Hall. Please bear in mind that Colston Steet is only accessible in one direction from the city centre promenade - when driving either from Park Street/Anchor Road toward the M32. Page 9

STAGE PLAN Page 10