WIRE AND CABLE FIRE TESTS

Similar documents
Adapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Fiberglass - Technical Data

IBM Enhanced Color Display. Personal Computer. Hardware Reference Library _.-

MultiSync XG135LC Distance Chart

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Continuous Flex Data Cable

Power Injector 1520 Series

Distributed Design Series

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Fluid Cooling P-BAR b Industrial BOL Series

FLUID VIEW 12V LED TAPE LIGHT

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

NEC Display Solutions of America, Inc. U300X Installation Guide Desktop and Ceiling Mount v1.3

DS1 Cross-Aisle Panel

ENGINEERING COMMITTEE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SCHEDA TECNICA. Amarro per cavi 13,5mm Amarro per cavi 16,5mm. MS217F00 Amarro per cavi 13,5mm MS218F00 Amarro per cavi 16,5mm

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

NEMA JM/JP Close Coupled Pump Motors. Features Include: NEMA MG1-Part 31 inverter duty 15:1 constant torque, 20:1 variable torque.

System Satellites Acoustimass Module. 2.5" (64 mm) full-range driver (per satellite) 5.25" (133 mm) dual voice coil low frequency driver

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES


Energy Efficiency Labelling for Televisions A guide to the Commission Delegated Regulation (EU) 1062/2010

Cables for robot applications

CABLE CLEAT FAQs. Engineering Series. 1. What is a cable cleat?

FREE STANDING CABINETS - S SERIES

Lashing Rods NOMENCLATURE GENERAL RECOMMENDATIONS. C = D x m = D x.666. m = D x.414. m = D x.483. C = (D + m) x.850. Length.

ROTARY ENCODER SELECTION. A Step by Step Guide

Panaray 802 Series III TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

High performance circuit breakers

STRUCTURED CABLE SYSTEM (SCS)

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Quick-disconnect cables. Adjustable mounting brackets

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Astronomy Lab - Lab Notebook and Scaling

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, JAM-NUT MOUNTING, REMOVABLE CRIMP CONTACTS, SERIES III, METRIC

AN OVERVIEW OF THE REAL SCALE TESTS IN THE FIPEC PROJECT (FIRE PERFORMANCE OF ELECTRICAL CABLES)

Channel Cable Tray - Accessories

Temposonics. Magnetostrictive Position Sensors. L Series (Model LH) to G-Series Linear-Position Sensor. Cross Reference A

User Manual. Model 979T and 979R Digital Audio Converters

QuickNet Copper Cabling in the Data Center

FREE STANDING CABINETS

Mining and Petrochemical Fiber Optic Cables

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

COUNTY OF LOS ANGELES SPECIFICATIONS For SHERIFF'S DEPARTMENT

DUCAT-IV Adjustable Aim Recessed LED Downlight

Bookcheck Model 966. Site Planning Guide

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

Test-Report chainflex

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Use Case Summary. Faisal Ahmad, Akros Silicon IEEE 802.3bt, September 2014

Operating Instructions

DRAFT. Proposal to modify International Standard IEC

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

WLS27 Multicolor LED Strip Light with EZ-STATUS

Rx antennas at IV3PRK: the 4-Square Rx Vertical Array

Introduction. Introduction

How can you determine the amount of cardboard used to make a cereal box? List at least two different methods.

HDBaseT vs. IP. Bob Ferguson, RCDD, CTS I Belden Regional Sales Engineer Broadcast and Audio Video Group

WALKING A TIGHT ROPE

Next Generation PoE Standards and Codes Update. Frank Straka Panduit Corporation

Toronto Hydro - Electric System

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

PT-RZ770LB/RZ770LW S P E C F I L E. DLP Projectors. As of January Specifications and appearance are subject to change without notice.

ILT-54HO-T5C/277 F54T5 HO > 0.98 ILT-39HO-T5C/277 F39T5 HO > 0.98 ILT-24HO-T5C/277 F24T5 HO > 0.

Magnetic and Hydraulic-Magnetic Circuit Breaker

40 A6B2 INCREMENTAL ROTARY ENCODERS,OUTSIDE DIAM 40 MODEL A6B2 SUBSTITUTE E6B2

HI-DEX PRODUCT SET DATASHEET

Flygt Submersible Motor Cables

S P E C F I L E PT-RW930LB/RW930LW. Product Number : DLP Projectors. Product Name : 1/20 RW930G_STF_01_16/10/2018 SFD16M035-3

Timber Measurement Society Reno

INVISILED ACCESSORIES

Safety Codes Council Conference Banff C Panel Discussion

PT-CW230 S P E C F I L E. As of November Specifications and appearance are subject to change without notice.

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

PT-DW750W/DW750LW PT-DW750B/DW750LB

P401 Installation Guide 40 LCD Display Rev 1.3

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

Understanding Digital Television (DTV)

M = Projection magnification B = Vertical distance between lens center and screen center

Split System Air Conditioner

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

architecture mounting Features Product lighting

Transcription:

TEST CSA C22.2 No 2556-13 Section 9.4 (FV-2/VW-1) (Small Scale Vertical) # OF VALUES REPORTED FOOTAGE REQUIRED 3 3 pieces: 24 each 5 7 days PERFORMANCE TIME CSA-FT1 (Small Scale Vertical) 3 5 pieces: 24 each 5 7 days CSA-FT2 (Small Scale Horizontal) 2 3 pieces: 10 each 5 7 days IEC 60331-21 (Fire Test Under Load) 1-3 3 pieces: 60 each 45 60 days IEC 60332-1-2 (Small Scale Vertical) 2 3 pieces: 24 each 5 7 days IEC 60332-1-3 (Small Scale Vertical) 2 3 pieces: 24 each 5 7 days IEEE 383 (Vertical Tray) 1974 (Standard or Modified to 210,000 BTU/hr) 3 Varies with cable diameter; IEEE 383 (Vertical Tray) 2003 IEEE 1202 (Vertical Tray) UL 1685 Section 4 UL 1685 Section 12/FT4 UL 1581 Section 1160 (Vertical Tray) UL 1581 Section 1164 UL 1581 FT1 (Small Scale Vertical) 2 3 pieces: 18 each 5 7 days UL 1581 FT2 (Small Scale Horizontal) 2 3 pieces: 10 each 5 7 days UL 1581 VW1 (Small Scale Vertical) 1 3 pieces: 18 each 5 7 days -- Continued on Page 2 -- Page 1 of 5

Wire & Cable Footage Calculation for Various Vertical Tray Fire Tests Using Table 1 English Units TABLE 1 CABLE DIAMETER (inches) # Cables in each bundle # bundles in the tray Total # of 8 ft. Lengths Total Feet From But less than Per Test Per Test Per Test Per Test 0.12 19 13 247 1,976 0.12 0.20 19 8 152 1,216 0.20 0.24 7 9 63 504 0.24 0.35 3 10 30 240 0.35 0.43 3 8 24 192 0.43 0.51 3 7 21 168 0.51 0.59 1 11 11 88 0.59 0.75 1 9 9 72 0.75 0.83 1 8 8 64 0.83 1.00 1 7 7 56 1.00 1.10 1 6 6 48 1.10 1.50 1 5 5 40 1.50 2.00 1 4 4 32 2.00 2.90 1 3 3 24 2.90 4.70 1 2 2 16 Use this table for the following test methods: 1. UL 1685 Section 12 FT4 2. UL 1581 Section 1164 FT4 3. IEEE 1202 4. IEEE 383 2003 Example: Footage Calculation Using a 0.43 Diameter Cable Footage for each individual test 168 Total footage to be submitted for testing 3 x 168 = 504 ft. -- Continued on Page 3 -- Page 2 of 5

Wire & Cable Footage Calculation for Various Vertical Tray Fire Tests Using the Standard Calculation Formula English Units FORMULA N = (4 D) + 0.33 N is the number of cables (rounded up to the next whole number) D is the diameter of the cable in inches Use this formula for the following test methods: Multiplier 1. UL 1685 Section 4 x 3 2. UL 1581 Section 1160 x 3 3. IEEE 383-1974 x 4 Example: Footage Calculation for UL 1581 Section 1160 Using a 0.43 Diameter Cable (4 0.43) + 0.33 # of 8 ft. lengths per test 9.30 + 0.33 = 9.63 (round to 10) Footage for each individual test 10 x 8 = 80 Total footage to be submitted for testing 80 x 3 = 240 ft. -- Continued on Page 4 -- Page 3 of 5

Wire & Cable Footage Calculation for Various Vertical Tray Fire Tests Using Table 2 Metric Units TABLE 2 CABLE DIAMETER (mm) # Cables in each bundle # bundles in the tray Total # of 2.44 Meter Lengths Total Meters From But less than Per Test Per Test Per Test Per Test 3 19 13 247 603 3 5 19 8 152 371 5 6 7 9 63 154 6 9 3 10 30 73 9 11 3 8 24 59 11 13 3 7 21 51 13 15 1 11 11 27 15 19 1 9 9 22 19 21 1 8 8 20 21 26 1 7 7 17 26 28 1 6 6 15 28 39 1 5 5 12 39 52 1 4 4 10 52 73 1 3 3 7 73 120 1 2 2 5 Use this table for the following test methods: 1. UL 1685 Section 12 FT4 2. UL 1581 Section 1164 FT4 3. IEEE 1202 4. IEEE 383 2003 Example: Meter Calculation Using an 11 mm Diameter Cable Meters for each individual test 51 Total meters to be submitted for testing 3 x 51 = 153 meters -- Continued on Page 5 -- Page 4 of 5

Wire & Cable Footage Calculation for Various Vertical Tray Fire Tests Using the Standard Calculation Formula Metric Units FORMULA N = (101.6 D) + 0.33 N is the number of cables (rounded up to the next whole number) D is the diameter of the cable in millimeters Use this formal for the following test methods: Multiplier 1. UL 1685 Section 4 x 3 2. UL 1581 Section 1160 x 3 3. IEEE 383-1974 x 4 Example: Meter Calculation for UL 1581 Section 1160 Using an 11 mm Diameter Cable (101.6 11) + 0.33 # of 8 ft. lengths per test 9.24 + 0.33 = 9.57 (round to 10) Meters for each individual test 10 x 2.44 = 23.35 (round to 24) Total meters to be submitted for testing 24 x 3 = 72 meters Page 5 of 5