Indication modules. LED-indication modules. Datasheet

Similar documents
Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Process transmitter RMA422

Bimetal Temperature Switch

CAMTO LTD. Arc detecting system DC/AC

263 Series LED Bargraph Indicator and Controllers

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Kuhnke Technical Data. Contact Details

02/11/2015

Capacitance Limit Detection nivotester FTC 420/421/422

EVENT INPUT/OUTPUT MODULE [PUME]

Preset counters, electronic

Lt DELTA USA, Inc

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Pulse Counters, electronic

Simply clever! The digital DIN-rail time switches by Grässlin

Process Transmitter RMA 422

DATA SHEET Panorama Rudder Indicator, TRI-2

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Figure 1: Device components

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Level Measurement silometer FMC 420, FMC 423

Multifunction devices

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Operating Manual RISH OPTIMA VAF

Centrifuge 5418/5418 R

Rack mounted telephone- and leased line modem for industrial applications

Operating instructions Electronic preset counter Type series 717

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

2L-CG-Monitoring Module

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

LCD Thermometer / Clock S No. 1253

SH2RE16A4. Output relay module. Benefits. Description

NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Kramer Electronics, Ltd.

Linear flow control with actuator IFC

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Arc-fault Protection System

Wall-/Pipe-Mount Level Indicator

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Connecting cables for valves, round plug connectors Product range overview

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

HS-509 VIBRATION TRIP MODULE

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Signal Tower KombiSIGN 70

LD OEM/LD PDS/LD PeCo

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

GV 460 / GV 461 Impulse Splitters for Incremental Encoders with Potential Separation between Input and Outputs

Art M Digital codelock module

Datasheet - SRB301LC 24VAC/DC

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Safety Light Curtains

Actuators IC 20, IC 40

LED Driver Compact dimming

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

IMPAC Infrared Thermometers

Operating Instructions Dimmer for V Incandescent Lamps

LED Driver Linear / area fixed output

Datasheet - SRB-E-201ST

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMD-1541W. 15-inch high grade LCD monitor. Overview

SERIES 400 SERIES 620

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Sensor technologies Proximity sensors Series ST4. Brochure

LED Backlight for Technics amplifiers

LED Driver Linear / area dimming

EMC Solutions Noise filtering

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

DVI KVM Switches DVIMUX 7.2

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Roof-mounted Blue e+ cooling unit Integration solution VX25

Magnecraft Power Relays

Single Point Flow Monitor SW118 SW119

Simple all-in-one design style with front stereo speakers and natural ventilation system

Emergency lighting units EM powerled

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

Emergency lighting units EM powerled

Absolute Encoders Multiturn

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11

VAT 20 Adjustable Frequency Drive

Transcription:

Indication modules LED-indication modules Compact module in a 96 x 96 mm housing for panel mounting 8 or 16 channels with exchangeable LED s Several alarm voltages in a range from 24 V up to 230 V Integrated lamp test push button Collective report optional Front panel marking: transparent window for slide-in labels Low built-in depth 08.07.2010 Datasheet SM-LAB-DB-UK-003

LED-indication modules Technical description The LAB-indicators are compact modules for panel mounting, with 8 or 16 channels and integrated lamp test push buttons. In the basic version (without collective report) the connection of an additional external test button, is possible. The devices are equipped with LED s in red or green colour, mounted on plug base, which are interchangeable and different LED colours can be installed after removing the front panel. Other colours are available in a set of 10 LED s per colour. Note: Always use high efficiency LED types! Attention: Disconnect supply voltage! Bezeichnung LAB 08-1 LAB 08-1M Ausrüstung 8 channels in NO design LED colour green external lamp test 8 channels in NO design Collective report * LAB 08-1MR 8 channels in NC design ** Collective report * LAB 08-1lMR 8 channels in NC design ** Collective report inverted LAB 16-1 LAB 16-1M 16 channels in NO design LED colour green external lamp test 16 channels in NO design Collective report * LAB 16-1MR 16 channels in NC design ** Collective Report * LAB 16-1lMR 16 channels in NC design ** Collective report inverted * Each discrete alarm can be selected by programming jumpers to assign on collective report. In standard the collective report is a NO contact on request it can be realized as a NC contact. An inverting function is also available. ** When the collective report contact is wired as NC, then not used inputs have to be connected on L1 or +. page 2 of 8

Type* Article No.* Collective report LAB..-1/24 LAB..-1/48 LAB..-1/60 LAB..-1/110 LAB..-1/125 LAB..-1/220 LAB..-1/230 LAB..-1M/24 LAB..-1M/48 LAB..-1M/60 LAB..-1M/110 LAB..-1M/125 LAB..-1M/220 LAB..-1M/230 LAB.. -1MR/24 LAB.. -1MR/220 LAB.. -1MR/230 LAB.. -1IMR/24 LAB.. -1IMR/60 LAB.. -1IMR/110 LAB.. -1IMR/125 LAB.. -1IMR/220 LAB.. 1IMR/230 21LAB..1011 21LAB..10D2 21LAB..10E3 21LAB..10F5 21LAB..10H5 21LAB..10J7 21LAB..10U7 21LAB..1M11 21LAB..1MD2 21LAB..1ME3 21LAB..1MF5 21LAB..1MH5 21LAB..1MJ7 21LAB..1MU7 21LAB..1MR1 21LAB..1MRJ 21LAB..1MRU 21LAB..1IMR1 21LAB..1IMRE 21LAB..1IMRF 21LAB..1IMRH 21LAB..1IMRJ 21LAB..1IMRU Design of collective report not available - normal normal inverted Normally open Normally open Normally open Level of signal input Low High LED off active Contact of collective report if U B present U B break down not available Low off open open High active closed open Low active closed open High off open open Low active open open High off closed open LED-indication modules page 3 of 8 *.. is used as a wildcard for 08 or 16 In the following table the states of the LEDs and of the collective report are shown in dependency of the device type and the states present at the signal inputs.

page 4 of 8 Type LAB 08-1/24 LAB 08-1/48 LAB 08-1/60 LAB 08-1/110 LAB 08-1/125 LAB 08-1/220 LAB 08-1/230 Article No. 21LAB081011 21LAB0810D2 21LAB0810E3 21LAB0810F5 21LAB0810H5 21LAB0810J7 21LAB0810U7 Supply voltage 48 V DC 60 V DC 230 V AC +10 / -15 % Power consumption max. 1.5 W max. 3 W max. 3.5 W max. 3.5 W max. 3.5 W max. 5.5 W max. 5.5 W Signal voltage 48 V AC/DC 60 V AC/DC 230 V AC/DC max. input current per signal input approx. 6 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma Operating and ambient temperature without condensation -20 C...+60 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C Technical data LED-indication modules Type LAB 16-1/24 LAB 16-1/48 LAB 16-1/60 LAB 16-1/110 LAB 16-1/125 LAB 16-1/220 LAB 16-1/230 Article No. 21LAB161011 21LAB1610D2 21LAB1610E3 21LAB1610F5 21LAB1610H5 21LAB1610J7 21LAB1610U7 Supply voltage 48 V DC 60 V DC 230 V AC +10 / -15 % Power consumption max. 2.5 W max. 5 W max. 6 W max. 6 W max. 6 W max. 10 W max. 10 W Signal voltage 48 V AC/DC 60 V AC/DC 230 V AC/DC max. input current per signal input approx. 6 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma Operating and ambient temperature without condensation -20 C...+60 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C

Type Article No. LAB 08-1M/24 LAB 08-1MR/24 LAB 08-1IMR/24 21LAB081M11 21LAB081MR1 21LAB081IMR1 LAB 08-1M/48 21LAB081MD2 LAB 08-1M/60 LAB 08-1IMR/60 21LAB081ME3 21LAB081IMRE LAB 08-1M/110 LAB 08-1IMR/110 21LAB081MF5 21LAB081IMRF LAB 08-1M/125 LAB 08-1IMR/125 21LAB081MH5 21LAB081IMRH LAB 08-1M/220 LAB 08-1MR/220 LAB 08-1IMR/220 21LAB081MJ7 21LAB081MRJ 21LAB081IMRJ LAB 08-1M/230 LAB 08-1MR/230 LAB 08-1MR/230 21LAB081MU7 21LAB081RMU 21LAB081MRU 230 V AC +10 / -15 % Supply voltage 48 V DC 60 V DC Power consumption max. 2.0 W max. 3.5 W max. 4.0 W max. 4.0 W max. 4.0 W max. 6.5 W max. 6.5 W Signal voltage 48 V AC/DC 60 V AC/DC 230 V AC/DC max. input current per signal input Operating and ambient temperature without condensation approx. 6 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma -20 C... +60 C -20 C... 50 C -20 C... +50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C LED-indication modules page of 8 Type Article No. LAB 16-1M/24 LAB 16-1MR/24 LAB 16-1IMR/24 21LAB161M11 21LAB161MR1 21LAB161IMR1 LAB 16-1M/48 21LAB161MD2 LAB 16-1M/60 LAB 16-1IMR/60 21LAB161ME3 21LAB161IMRE LAB 16-1M/110 LAB 16-1IMR/110 21LAB161MF5 21LAB161IMRF LAB 16-1M/125 LAB 16-1IMR/125 21LAB161MH5 21LAB161IMRH LAB 16-1M/220 LAB 16-1MR/220 LAB 16-1IMR/220 21LAB161MJ7 21LAB161MRJ 21LAB161IMRJ LAB 16-1M/230 LAB 16-1MR/230 LAB 16-1MR/230 21LAB161MU7 21LAB161MRU 21LAB161MRU 230 V AC +10 / -15 % Supply voltage 48 V DC 60 V DC Power consumption max. 3.5 W max. 6 W max. 7 W max. 7 W max. 7 W max. 11 W max. 11 W Signal voltage 48 V AC/DC 60 V AC/DC 110 V AC/DC 230 V AC/DC max. input current per signal input Operating and ambient temperature without condensation approx. 6 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma approx. 4 ma -20 C...+60 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C -20 C...+50 C

LED-indication modules Technical data Mechanical data Assembly Mounting position Panel frame Required installation depth Panel cut out Weight Connection terminals Panel mounting arbitrary 96 x 96 mm 80 mm 91 x 91 +0.5 mm 0.5 kg cross section 1.5 mm² Ambient enviroment Storage temperature -20 C...+70 C without condensation Allowed relative humidity max. 75 % (group F DIN 40040) Type of protection front side IP 40; IP 42 with window door; IP 65 with protection cover Type of protection rear side IP 20 Noise immunity EMC-tested acc. to EN 61000-4-2,4,5 The information given for alternating voltages are refering to a sinusoidal alternating voltage with a frequency of 50/60 Hz and all information on an ambient temperature of 25 C, otherwise noted. Terminal assignment Lamptest Supply Lamptest Supply 1...8 9...16 1...8 LAB 08-1 LAB 16-1 Collective report Supply Collective report Supply 1...8 9...16 1...8 LAB 08-1M, LAB 08-1MR, LAB 08-1IMR LAB 16-1M, LAB 16-1MR, LAB 16-1IMR page 6 of 8

LED-indication modules DIP-Switches in devices with collective report After loosening the four screws and detaching the front plate DIP switches become visible. Each single report can be assigned to the integrated collective report by these DIP-switches. With the switchgroup S1 the channels 1... 8 and with the switchgroup S2 the channels 9... 16 can be configured. If the switch is set to ON, the collective report will be triggered through the assigned input. At the LAB 08 variants only the DIP switch group S1 is existend. LAB 08-1M, LAB 16-1M LAB 08-1MR, LAB 16-1MR, LAB 08-1IMR, LAB 16-1IMR Dimensional drawing Dimension in mm Subject to changes without prior notice page 7 of 8

LED-indication modules Accessories 21KST1 Clear window door (IP 42) 21KSH1 Protection cover (IP 65) 21BSV1 Labelling patterns (set of 10 patterns) 21BSV-Soft Disc of labelling patterns for WinWord from Version 6.0 onwards 21LEDGELB LED 5 mm yellow high efficiency 21LEDGRÜN LED 5 mm green high efficiency 21LEDROT LED 5 mm red high efficiency 21LEDWEISS LED 5 mm white high efficiency Do you need fault annunciators with fault storage? BSM - Panel mounting basic fault annunciators Devices with 8, 16, 32 and 48 s Sealed front, protection class IP 54 Integrated buttons, functional inputs and relay outputs Self monitoring Optional DIN rail modules for PCS contacts Optional Software-Parameterisation via PC Realisation of all common alarm sequences Extremly bright LED with great reading angle and in many colours FSM - Drop flaps fault annunciators Parameterisable compact fault annunciator for 10 alarms Signaling of stored reports also with voltage break down 10 neon yellow drop flaps and additionally green LEDs for permanent and dynamic status display Integrated buttons, functional inputs and relay outputs Live contact and nonvolatile eventmemory Supply and alarm signal voltage 12 V...250 V AC/DC 2 parameterisable collective reports and internal horn Parameterisation via DIP switches or PC programm Marker stripts pocketable into transparent window Contact Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 71522 Backnang Germany Tel. +49 (0) 7191.182-0 Fax. +49 (0) 7191.182-200 info@ees-online.de www.ees-online.de