VIDEO DOOR PHONE. Model No. APV-4PM

Similar documents
VIDEO DOOR PHONE CAV-51M

User Manual Wide Color Video Phone

User Manual Color video door phone

User Manual Color video door phone

User Manual Color Video Door Phone

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

User Manual. Color video door phone CDV-40Q

User Manual. Fineview Video Phone CDV-43MH/CDV-43MH(M)

DOOR STATION. .in.ua.

UTP TRANSMITTER & RECEIVER SUT-80/SUR-10 USER S MANUAL ENGLISH

KCV-J351 MANUAL DIGITAL COLOR VIDEOPHONE. Warranty. Warranty Card. To receive after service, have the following ready before you contact our branches.

LCD MONITOR. 27 Wide LED Monitor User Manual. User Manual P276L

DVI-D Fiber Optic Cable

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

ARS x4 MATRIX SWITCHER Instruction Manual

Installation Guide VL-MV10. Model No.

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Warning & Cautions. Warning. Cautions

PNP300 / PNP300UN / PNP350

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

LIGHT COPILOT II. elationlighting.com Internet:

PLL2210MW LED Monitor

PLL1920M LED LCD Monitor

Characteristics of DS p.03. Function of DS p.04

SM-10 SAT Level Meter User s Manual

DISTRIBUTION AMPLIFIER

Indoor/Outdoor Security System with Quad Monitor User s Manual

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Proximity Card Reader. User s Manual

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

MC14 MC15 MC21 72-MC COLOR MONITOR. Product Implementation Standard No.:Q/WP :QB/

HAND-FREE COLOR VIDEO DOORPHONE. Installation and Operation Manual

32LD9800TA 37LD9800TA

VITEK VTM-TLM191 VTM-TLM240

User Guide. Centrex Recording Interface

New Multi Function Controller

WDK-2500-STROBE. User Guide

PL2410W LCD Monitor USER'S GUIDE.

HDMI 1.4 OVER SINGLE CAT5/6/7 EXTENDER WITH BI-DIRECTIONAL IR and RS232 TRANSMITTER & RECEIVER AT-HD4-100SR

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

Operating Instructions

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Proximity Card Reader. User s Manual

Instruction Manual Digital Wireless Intercom SAMCOM FTAN20AA

Jinyoung Contech Co., Ltd.

Model. Owner s Manual

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

Owner s Manual. TFT-LCD TV High Brightness & Contrast NICAM/A2 Stereo Sound MODEL: L15SV6-A0, L17LV6-A1,L20AV6-A0 L17L6A-G1,L20L6A

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

Caller Display 1000 User Guide

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

User Manual. June 30, Copyright 2004 Canopus Co., Ltd. All rights reserved.

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

May result in personal injury or property loss. Indicate the behaviors that must be prohibited

SAFETY WARNINGS AND GUIDELINES

KCV-A374SD / D374SD MANUAL

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

SY-HDBT-100 Extender Set

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Led Dynamic DMX Tri Curtain Manual

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

DMX LED light effect with 4 lenses

QWCD35/ QWCD35SD QWCD50/ QWCD50SD

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

TP VGA/COMPONENT+ AUDIO TWISTED PAIR (UTP) TRANSMITTER

LEDWash RGBW USER MANUAL

FOREST SHUTTLE S / L / M RECEIVER

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

V25 V25+ WS WS WS WS V27 WS-65517

USER MANUAL Full HD Widescreen LED Monitor L236VA

PXL2760MW LED LCD Monitor

Spectra Batten (Order code: LEDJ95)

Instructions. P MHz 1X/10X Passive Probe

Electric Motorized Projection Screen PowerMax Tension Series

HongZhao Innovation Electronic Co., Ltd. Wireless Video Door Phone

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

RT AUDIO RETRACTABLE CABLE

RT USB RETRACTABLE CABLE

Wireless Video Door Phone

Important Safety & Warning Precautions

Studio 300/400 Monolight with Built-in R2 2.4GHz Radio Remote System

User Manual. Tensioned Screens. Website: Tel:

SyncMaster 153V/173V/152V/172V/193V/192V/153S/173S/153B/173B

LED Thunder S-150 Code 1097

Starling Tab-Tension 2 Series

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User manual S19C150N S19C150F S20C150FL S22C150N

1. Safety precautions (Must Read)

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

BELL TIMER OPERATING INSTRUCTIONS

TVAC20000 User manual

Wired Troubleshooting Manual

Transcription:

VIDEO DOOR PHONE Model No. APV-4PM Thank you for purchasing our COMMAX product. Please carefully read this User s Guide (in particular, precautions for safety) before using the product and follow the instructions to use your productexactly. The company is not responsible for any safety accidents caused in abnormal operation of the product.

Table of Contents Warnings and caution Features & Specifications 2 4 Part Name & Function Multi Entry Panel Calling Sub unit calling (Intercommunication) Guard station or external area calling Call/ Talk duration Setting In-House unit as a Master and Sub Unite Chime sound Changing and initialization of the password Opening the entrance of a Multi-entry Panel With Password Wiring System diagrm 5 6 6 6 7 7 8 8 9 10 11 1

Warnings and caution Warnings and caution Make sure to follow the instructions to prevent any danger or property losses. It indicates prohibition. It indicates prohibition. Warning Death or serious injury is expected. It indicates prohibition of disassembly. It indicates prohibition of contact. Caution An injury or property losses are expected It indicates prohibition of disassembly. It indicates prohibition of contact. It indicates dos and don ts. It indicates dos and don ts. It indicates that the plug should be pulled out from the socket. It indicates that the plug should be pulled out from the socket. Warning Caution Do not put the plug in the socket simultaneously. It may generate abnormal heat or cause a fire. Do not connect to other products while in use. It may cause breakdown. Do not forcibly bend the cord or put a heavy object on the product. It may cause a fire. If the socket holes are larger than normal, do not put the plug. It may cause an electric shock or a fire. Make sure that dust or foreign substances are not gathered on the product. Make sure to prevent foreign substances from entering the product. It may cause a breakdown. Do not use water, thinner or a detergent used to wash oil products when you wash the exterior. Make sure to wash it by using a dry cloth to prevent any breakdown or electric shock. Do not install the product in a humid place. It may cause an electric shock or a fire. Do not forcibly pull out the cord from the socket. If the cord is damaged, it may cause a fire or an electric shock. Do not put a heavy object on the product. It may cause a breakdown. Do not disassemble or give an impact to the product. Avoid direct rays of the sun or heating devices at a time of installation. Do not put the plug in the socket with a wet hand. It may cause an electric shock. Do not disassemble, repair or modify the product. It may cause a fire, an electric shock or an injury due to malfunction of the product. Do not use AC circuit breaker. It may cause an electric shock. Install the product in a flat and stable place. Otherwise, it may not function properly. Pull the plug if the product is not used for a long time. If the product generates strange sound, make sure to pull the plug immediately and contact Commax service center. 2 3

1. Features & Specifications 2. Parts names & Function This is a DC type B/W Video phone. It can add up to a maximum of 2 sub units in each residence and is a surface mount type video phone that connects to a guard station or external area. It s functions include Door release and intercommunicating 1) Features 1 DC type B/W video phone 2 When installing only 1 master unit, a power is supplied from a Floor distributor without an additional power supply. 3 Sub monitors need an extra power source. 4 4 CRT Monitor 5 3 buttons : Guard station call, door release and extension call. 6 COMMAX chime(sol, Mi, Do) is the ring tone call sound from Multi Entry Panel And there is a doorbell Ding-Dong sound from a individual door 7 Entrance release 8 6 wires UTP Cable (CAT.5) including power source. 2. Specifications ITEMS Wiring Power Voltage Transmission Method Screen Dimension Power requirements Distance range APV-4PM Floor distributor: 6 wires (TALK2, DATA1, POWER1, VIDEO1, GND1) DC24V~28V / 5A (Master: Supplied from floor Distributor) (Slave: Extra power sourse is required) Full duplex 4 CRT Stand by : 60mA / Maximum operation :600mA Between Floor Distributor and In-house unit UTP (Ø0.5) 50m No. Details No. Details 1 Handset 8 Call volume control 2 CRT Screen 9 Power switch 3 Speaker 10 Video brightness control 4 Power Lamp 11 Connecting terminal to Floor distributor 5 Extension call button 12 Connecting terminal to sub unit 6 Guard station call button 13 Connecting terminal to Audio type Door bell 7 Door release button This is an in-house unit which is a B/W video phone. Up to 4 residences are connectable with a single Floor distributor through a Building Distributor connected with the Multi Entry Panel. Each residence can add 2 sub-units, which comes to 3 units in total including master unit. 4 5

3. Multi Entry Panel Calling 1 When calling from the Multi-Entry Panel, you will hear the COMMAX chime and the image of the visitor will be shown on the screen 2 Pick up the handset to initiate conversation. 3 When opening the door of the Multi Entry Panel during a conversation, press the Door release button and the entrance will open. (The call conversation is ended right after the release of the door) 4 When conversation is over, hang up the handset. 4. Sub unit calling (Intercommunication) 1 Pick up the handset and, press the extension call button, to call to the sub unit. 2 When the sub unit responds, conversation occurs. (calling both the Extension and Master unit is possible) when calling to Guard station with another unit or while talking with other Extension, another in-house unit can not make a call. 3 while talking with another extension unit and an incoming call from the Multi-Entry panel arrives, 4 If this time, you have 30seccnds to answer the call from the Multi-Entry panel by pressing the hook switch once on the extention unit(only one extention unit can have a conversation with Multi-Entry panel at a time) 5. Guard station or external area calling 1 Pick up the handset and press the Guard call button to call the Guard Station. 2 When the guard station responds, conversation can occurs. * The Guard station unit does not have a calling function, only receiving) * If the Guard unit is on the line with another residence or Multi entry unit, you will hear a busy tone) 6. Call/ Talk duration This is applied to all calls and conversation. 1 Calling time lasts for 30 second. 2 Talking duration lasts for 60 second. 7. Setting In-House unit as a Master and Sub Unit - This setting should be set by Muliti entry panel which should be connected to chanel 1 - when a single unit is installed, the setting should be set as a master unit. in case more than 2 unit are installed one should be set as the master, and the rest should be set as slave unit - The Door Release and Extension button on the unit run as a selection to master or slave in this mode 1) Setting Master 1 Set the ID as 0 on Multi-Entry panel which shold be connected to chanel 1 - The default of all Multi Entry Panels is assigned to 0. 2 While picking up the handset of an in-house unit, press the extension call button and the door release button at the same time. 3 You can communicate with the Multi Entry Panel while the resident s number is displayed on it. 4 When the *** -> M message is displayed on the Multi Entry Panel when you press the Door Open button on an in-house unit. 5 Then, register the ID of the shown residence, and press button to hear a sound of completion. 6 The registration is complete when you hang up the handset. (Repeat this process for other residentes) 7 Set the ID as 1 on the Multi-Entry panel after completing the registration 2) Setting the Sub-Unit 1 Set the ID as 0 Multi-Entry panel which shold be connected to chanel 1 -The default of all Multi Entry Panels is assigned to 0 2 While picking up the handset of an in-house unit, press extension call button and the door open button at the same time. 3 You can communicate with Multi Entry Panel while the resident s number displayed on it. 4 When the *** -> S message is displayed on the Multi Entry Panel when you press the Extension call button on the in-house unit. 6 7

5 Then, register the ID of the said residence, and press button to hear a sound of completion. 6 The registration is complete when you hang up the handset. (Repeat this process for other residentes) 7 Set the ID as 1 on the Multi-Entry panel after completing the registration 8. Chime sound Chime will sound when calling an individual door bell with audio type. 9. Changing and initialization of the password Note) The doors do not open by default password 1234. Only after changing default Password, can you use this function 10. Opening the entrance of a Multi-entry Panel With Password Note) The doors do not open by default password 1234. Only after changing default Password, can you use this function 1) Open the entrance with resident password 1 Press resident number and 2 Press PIN number and the button button - The door opens with the OPEN message display on the LCD screen. 2) Open the entrance with Building password 1 Enter 9900 and button 2 Enter the Building password and the button 1) Initialization for the password (only the password for the Master unit is initialized) 1 Shut off master unit and turn it on again while holding the extension call button and Door release button at the same time for 3 seconds at the same time. 2 The password will initialize to 1234 when the blink of LED stops. Note : Default password : 1234 2) Changing Resident Password(From Multi Entry Panel) 1 Hold Residence Number and and release when LCD stops blinking. 2 Enter Current password. 3 Hold button for 2 seconds button for 2 seconds and release when LCD stops blinking. 4 Enter New Password with 4 digits on Multi Entry Panel displaying NEW PW : message. 5 Hold button for 2 seconds and release when LCD stops blinking. 6 Repeat New password to confirm it. 7 Hold button for 2 seconds and release when LCD stops blinking. 8 9

11. Wiring 12. System diagam 1) Wiring method - Please pay attention to the polarity of the wires. Units will not work properly when mis-wired * Use UTP(CAT.5) cable and be careful to match the color of the wires shown to the left - The Power of the Master unit supplied from the Floor distributor without an additional power supply, but additional sub units are needed separate a power source. (There is no power line connection between Mast unit and Sub units) CH2 10 11

a513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed In Korea/ 2007.10