Jeff Lyons System Simulation and Development Directorate Aviation and Missile Research, Development, and Engineering Center

Similar documents
1x12 VGA & Audio over CAT5 Splitter

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Interview Management System Installation Guide

Target Interface / Construction Compliance Inspection Checklist

Interview Management System Installation Guide. (303) x500

LCD VALUE SERIES (32 inches)

Dell Wyse 5030 PCoIP Zero Client

Room Recommendations for the Cisco TelePresence System 3210

VGA, Audio & RS-232 Serial with IR Pass-Thru over Single CAT5 /RJ45 Extender Kit

SECTION 7 -- CROSS-CONNECT SYSTEMS

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Model UH-2C-3S 3-port HDMI UTP Extender

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

AV Media Extender IE-500 User Manual

SmartVideo: SSV Feature Summary

CAT EXT-CAT USER MANUAL

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

CP-255ID Multi-Format to DVI Scaler

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

RATE-ADAPTIVE VIDEO CODING (RAVC)

LM-WPS41 HD Caption Adder. User. Manual

SPECIAL SPECIFICATION 2344 TMC Support Equipment

VITEK VTM-TLM191 VTM-TLM240

Environmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8

CMSDI G-SDI Matrix

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

SECTION COMMUNICATIONS HORIZONTAL CABLING

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Power Injector 1520 Series

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

Litile34 OPERATION MANUAL

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

VGA & Audio over CAT5 Distribution Series

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

EXTENDER ELE8080. INSTALLATION Manual. Made in Taiwan

UNITED STATES AIR FORCE RESEARCH LABORATORY

Audio/Visual for Lower Level and Board Room A2.0 Projector:

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

AT&T January, 2012 Revised December, 2018 TABLE OF CONTENTS SECTION 1--INTRODUCTION...1-1

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Multi-Channel Passive Transceiver Hubs Installation Sheet

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Model LTM-1400 User Manual LTM Multiformat 1x4 Assignment Router / DA. (Component, Y/C, Composite, Balanced Audio, RS422) 2001 Laird Telemedia.

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

LedSync820C LED Video Processor USER S MANUAL

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Edition 1, August 2011 Copyright 2011 Smart-e (UK) Ltd.

PNP300 / PNP300UN / PNP350

TEST WIRE FOR HIGH VOLTAGE POWER SUPPLY CROWBAR SYSTEM

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

EXT-UHD600-1SC Version A1

HDMI EXTENDER ELE8088

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

INSTALLATION INSTRUCTIONS FOR

TITLE: FIBER OPTIC SHOCK FIXTURES

STRUCTURED CABLE SYSTEM (SCS)

RGB 470xi Series DUAL INPUT, ARCHITECTURAL INTERFACES ARCHITECTURAL INTERFACES MHz (-3dB) RGB video bandwidth.

CSLUX-300 Multi-Format to HDMI Scaler

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

Extender for HDMI over one CAT5

P-2 Installing the monitor (continued) Carry out as necessary

Copyright 01/2004 Rextron Technology, Inc. PP5-V Printed in Taiwan

DISTRIBUTION AMPLIFIER

The State of Remote Scientific Visualization Providing Local Graphics Performance to Remote ARL MSRC Users

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

UTAH 100/UDS Universal Distribution System

A Comparison of the Temporal Characteristics of LCS, LCoS, Laser, And CRT Projectors

HDMI over IP EXTENDER

SY-HDBT-100 Extender Set

SNG-2150C User s Guide

User Manual HDM-EXT-0110C. HDMI Extender over Single Cat.X with HDBaseT-Lite & Bi-directional IR 7.1 CH AUDIO. rev: Made in Taiwan

Noise Detector ND-1 Operating Manual

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

user guide SLX-111 also available: SLX-100, SLX-214 transmitter & receiver pair tel: +44 (0) ,

PRESET TEN ARCHITECTURAL TWO OWNERS MANUAL

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

CONNECTION TYPES DIGITAL AUDIO CONNECTIONS. Optical. Coaxial HDMI. Name Plug Jack/Port Description/Uses

and HDCP 2.2 supported Digital Matrix Switcher FDX-32UHD Specification

Generator protection relay

R-1580A Microwave Downconverter. Product Brochure

Applying LaPO 4 Phosphor via Spinning for BetaPhotovoltaic Devices

HDBaseT HDMI Extender

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

Transcription:

TECHNICAL REPORT RDMR-SS-11-32 PATRIOT ADVANCED CAPABILITY-3 (PAC-3) VIRTUAL ENGAGEMENT SIMULATION TESTBED (VEST) SHELTER REQUIREMENTS DOCUMENT Jeff Lyons System Simulation and Development Directorate Aviation and Missile Research, Development, and Engineering Center May 2012 Distribution Code A: Approved for public release; distribution is unlimited.

DESTRUCTION NOTICE FOR CLASSIFIED DOCUMENTS, FOLLOW THE PROCEDURES IN DoD 5200.22-M, INDUSTRIAL SECURITY MANUAL, SECTION II-19 OR DoD 5200.1-R, INFORMATION SECURITY PROGRAM REGULATION, CHAPTER IX. FOR UNCLASSIFIED, LIMITED DOCUMENTS, DESTROY BY ANY METHOD THAT WILL PREVENT DISCLOSURE OF CONTENTS OR RECONSTRUCTION OF THE DOCUMENT. DISCLAIMER THE FINDINGS IN THIS REPORT ARE NOT TO BE CONSTRUED AS AN OFFICIAL DEPARTMENT OF THE ARMY POSITION UNLESS SO DESIGNATED BY OTHER AUTHORIZED DOCUMENTS. TRADE NAMES USE OF TRADE NAMES OR MANUFACTURERS IN THIS REPORT DOES NOT CONSTITUTE AN OFFICIAL ENDORSEMENT OR APPROVAL OF THE USE OF SUCH COMMERCIAL HARDWARE OR SOFTWARE.

Form Approved REPORT DOCUMENTATION PAGE OMB No. 074-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing this collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503 1.AGENCY USE ONLY 2. REPORT DATE May 2012 4. TITLE AND SUBTITLE Patriot Advanced Capability-3 (PAC-3) Virtual Engagement Simulation Testbed (VEST) Shelter s Document 6. AUTHOR(S) Jeff Lyons 3. REPORT TYPE AND DATES COVERED Final 5. FUNDING NUMBERS 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Commander, U.S. Army Research, Development, and Engineering Command ATTN: RDMR-SSL-M Redstone Arsenal, AL 35898-5000 8. PERFORMING ORGANIZATION REPORT NUMBER TR-RDMR-SS-11-32 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING / MONITORING AGENCY REPORT NUMBER 11. SUPPLEMENTARY NOTES 12a. DISTRIBUTION / AVAILABILITY STATEMENT Approved for public release; distribution is unlimited. 12b. DISTRIBUTION CODE A 13. ABSTRACT (Maximum 200 Words) This report specifies the requirements to design and fabricate the Aviation and Missile Research, Development, and Engineering Center (AMRDEC) Systems Simulation and Development Directorate (SSDD) Patriot Advanced Capability-3 (PAC-3) Virtual Engagement Simulation Testbed (VEST) shelter. 14. SUBJECT TERMS Virtual Engagement Simulation Testbed (VEST), Shelter 15. NUMBER OF PAGES 14 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT UNCLASSIFIED 18. SECURITY CLASSIFICATION OF THIS PAGE UNCLASSIFIED 19. SECURITY CLASSIFICATION OF ABSTRACT UNCLASSIFIED 20. LIMITATION OF ABSTRACT NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. Z39-18 298-102 SAR i/(ii Blank)

TABLE OF CONTENTS I. INTRODUCTION... 1 II. MECHANICAL REQUIREMENTS... 1 III. ARCHITECTURAL REQUIREMENTS... 1 A. Storage Room... 2 B. Main Room... 2 C. Galley... 3 IV. ELECTRICAL REQUIREMENTS... 3 V. DATA AND COMMUNICATIONS REQUIREMENTS... 5 VI. SAFETY AND SECURITY REQUIREMENTS... 7 LIST OF ABBREVIATIONS AND ACRONYMS... 8 Page iii

LIST OF ILLUSTRATIONS Figure Title Page 1. Interior Layout... 2 2. Electrical/Data Layout... 4 3. Patch Panel Layout... 6 LIST OF TABLES Table Title Page 1. Mechanical s... 1 2. Architectural s... 1 3. Storage Room s... 2 4. Main Room s... 2 5. Galley s... 3 6. Electrical s... 3 7. Data and Communications s... 5 8. Wiring Diagram for External RWCIU to Internal DE9... 6 9. Safety and Security s... 7 iv

I. INTRODUCTION The Patriot Advanced Capability-3 (PAC-3) Virtual Engagement Simulation Testbed (VEST) shelter is to be a mobile test unit capable of interfacing with the tactical Patriot ground system in a field test environment. The shelter is to provide the capability to house all of the equipment and personnel necessary to conduct live PAC-3 virtual engagements. As such, the following sections outline the physical requirements necessary to meet this objective. II. MECHANICAL REQUIREMENTS The mechanical requirements for the shelter are listed in Table 1. Table 1. Mechanical s 1 The shelter shall be a standard 53-foot trailer configuration. 2 One Belly Box shall be mounted on the underside of the trailer to provide storage space. 3 One U-Bolt Global Positioning System (GPS) antenna mount sized for 0.75-inch pipe shall be installed on the side of the trailer with the patch panel ( 48). 4 One ladder shall be mounted on the exterior rear of the trailer providing roof access. 5 One Heating, Ventilation, and Air Conditioning (HVAC) unit shall be mounted on the forward exterior wall. HVAC shall be routed to control temperature of storage room and main room/galley separately. HVAC shall maintain temperature of all rooms between 65 F and 76 F. 6 The rear access door and equipment door shall be made exit only. 7 One shore power cable shall be housed on a reel on the underside of the body. 8 Two entry/exit platforms shall be installed: one below the rear exit door and one below the side entrance/exit door. Both platforms shall fold away, securely, to the underside of the trailer during transport. III. ARCHITECTURAL REQUIREMENTS The architectural requirements are shown in Table 2. Table 2. Architectural s 9 The interior layout of the shelter shall be customized In Accordance With (IAW) Figure 1. 10 The shelter shall be divided into three separate rooms, walled appropriately, with doors providing access between rooms. The doors shall be 28 inches in width. 11 All three rooms shall have fluorescent 120 Voltage Alternating Current (VAC) light fixtures mounted on the ceilings, with separate light switches in each room. 12 Five exterior lights shall be securely mounted providing nighttime illumination: one in the rear, two in front, and one on both sides of the trailer. Two switches shall be installed: one in the main room and one in the aft room. 13 The floor shall be tiled. 1

A. Storage Room Figure 1. Interior Layout The storage room requirements are shown in Table 3. Table 3. Storage Room s 14 The aft room shall be approximately 12 feet in length. 15 One 19-inch computer rack shall be mounted to the floor IAW Figure 1. The rack shall be mounted with the rear facing the interior wall and with enough space to service the rear components. 16 Floor-to-ceiling cabinets with doors shall be installed IAW Figure 1. 17 One Internal Telecommunications Patch Panel shall be installed IAW Figure 1 ( 49). Shelves shall be mounted IAW Figure 1. 18 The bottom corner of the interior wall shall be removed, IAW Figure 1, to provide a pathway for cables in and out of the storage room. The dimensions shall be approximately 5-x-5 inches. 19 The storage room shall be sound dampened to damp out computer equipment noise. If possible, wall thickness should be increased, insulated, and carpeted to maximize damping. B. Main Room The main room requirements are shown in Table 4. Table 4. Main Room s 20 The middle room shall be approximately 26 feet in length. 21 Desks/furniture at a standard height of 30 inches shall be installed, IAW Figure 1, to facilitate the use of computer equipment and provide a work area. The furniture need not be segmented as indicated in the figure; a single continuous desk is considered adequate. The two corner pieces of the desk shall be curved, as opposed to the rectangular depiction in the figure. Additionally, the desk shall have cut-outs near the wall to allow cabling to be run IAW Figure 1. 2

Table 4. Main Room s (Concluded) 22 One cabinet with doors shall be installed above each corner desk area IAW Figure 1. 23 Six office-style chairs shall accompany the desk area. A means to secure the chairs during transport shall be provided. The Herman Miller WC420P (BK/BJ/DS/BK) stacking chair shall be used. 24 One 8-x-2 foot Folding Murphy Table shall be installed on the wall IAW Figure 1. 25 One 42-inch Liquid Crystal Display (LCD) High Definition Television (HDTV) monitor shall be mounted on the wall, centered above the desk area. The monitor shall have at least one D-subminiature (D-sub) Video Graphic Array (VGA) input, one Digital Visual Interface (DVI) input, one High Definition Multimedia Interface (HDMI) input, and one component input. C. Galley The galley requirements are shown in Table 5. Table 5. Galley s 26 The forward room shall be approximately 12 feet in length. 27 One full-size refrigerator shall be securely installed IAW Figure 1. 28 One microwave shall be securely installed IAW Figure 1. 29 One two-drawer safe shall be provided Government Furnished Equipment (GFE) and securely mounted IAW Figure 1. 30 One water bottle shall be securely installed IAW Figure 1, above, but not on top of, two-drawer safe in 29. 31 A counter with overhanging cabinets shall be installed, IAW Figure 1, to provide a food preparation and storage area. 32 One 6-x-2.5 foot oval/rounded table shall be securely installed IAW Figure 1. 33 Six folding chairs shall accompany the table and be securely stored during non-use IAW Figure 1. IV. ELECTRICAL REQUIREMENTS The electrical requirements are shown in Table 6. Table 6. Electrical s 34 The shore power cable specified in 7 shall use the Appleton Powertite ACP1044CD connector. 35 The shelter shall be rated for 120/240 VAC, 60 Hertz, 3-Phase, and 200 Amperage (AMPS) power. 36 Wire shall be a minimum of 14-American Wire Gauge (AWG), and all 120 VAC wiring shall be routed in vendor approved cable raceways. A circuit breaker panel shall be installed, housing the circuit breaker for each circuit. 3

Table 6. Electrical s (Concluded) 37 One thermostat shall be installed in the main room. 38 Electrical circuits shall be installed to provide safe and load-balanced electrical power IAW Figure 2. The electrical outlets shall be installed low to the floor, IAW Figure 2, except where indicated. 39 One 110 volt/20 amp Ground Fault Interrupter (GFI) circuit shall be installed for refrigerator/microwave IAW Figure 2. 40 One 110 volt/20 amp circuit shall be installed for external use IAW 48. 41 One 220 volt/30 amp circuit shall be installed for the rack-mounted Uninterruptible Power Supply (UPS) located in the storage room IAW Figure 2. 42 The shelter shall provide lightning and surge protection for the 220 volt/30 amp circuit in the storage room. Figure 2. Electrical/Data Layout 4

V. DATA AND COMMUNICATIONS REQUIREMENTS The data and communications requirements are shown in Table 7. Table 7. Data and Communications s 43 Two separate networks shall be distributed from the rack area in the storage room. One network shall distribute either Belden DataTwist 350 Unshielded Twisted Pair (UTP) 1700A Solid (Category (CAT)-5e) cable, Belden DataTwist 350 patch 1752A Stranded (CAT-5e) cable, or Belden MediaTwist 1872A Solid (CAT-6) cable to Registered Jack (RJ)-45 sockets, IAW Figure 2, providing a Keyboard-Video-Mouse (KVM) network; one network shall distribute plenum-rated CAT-6 UTP cable to RJ-45 sockets, IAW Figure 2, providing a data network. 44 Dual RJ-45 sockets shall be installed low to the floor and external to the wall (not built-in) IAW Figure 2, except where indicated. 45 Panduit raceways shall distribute cabling from the rack area, through the wall cut-out, to the RJ-45 sockets along the bottom of the walls. Where necessary (for example, Murphy Table, Galley), Panduit raceways shall be run along the top of the walls. All cabling shall be color coded and marked appropriately on the ends. 46 Four 6-x-9 inch speakers shall be installed and recessed in the walls near the ceiling IAW Figure 1. If impossible to recess, speakers shall be mounted securely to walls. 47 The computer racks specified in 15 shall have at least one Alternating Current (AC) power strip mounted vertically near the rear. Horizontal and vertical cable management shall be installed. 48 One External Telecommunications Patch Panel shall be installed on the outside of the trailer. It shall be equipped with a weatherproof door that latches and locks. The panel shall be sized for 50-percent growth. The panel shall contain the following female connections: six CAT-6 RJ-45 (data) ports, six RJ-11 (voice) ports, two pair Straight Tip (ST) (fiber optic) connectors, two pair Standard Connector (SC) (fiber optic) connectors, eight Bayonet Neill-Concelman (BNC) connectors four of which are 50 ohm and four of which are 75 ohm, two tactical Patriot Radar Weapon Control Interface Unit (RWCIU) sockets, one VGA DE15F port, one DE9F Recommended Standard (RS)-232 port, one DVI port, two stereo Radio Corporation of America (RCA) jacks, two Universal Serial Bus (USB) ports, two Institute of Electrical and Electronic Engineers (IEEE) 1394 Firewire ports, and two 110 volt/20 amp sockets. A recommended layout for the patch panel is given in Figure 3. 49 One Internal Telecommunications Patch Panel shall be installed IAW 17 providing the same female connections as specified in 48 (pin-to-pin), except for the two tactical Patriot RWCIU plugs, which shall be replaced with two female DE9 connectors wired IAW Table 8. Additionally, one stereo receiver shall be installed providing access to the speakers in 46. If impossible to install in patch panel, receiver shall be installed securely in immediate vicinity. 5

Figure 3. Patch Panel Layout Table 8. Wiring Diagram for External RWCIU to Internal DE9 ECS Connector Bendix 9-Pin Connector Signal MS17346R20C335 (Female) C Voice + 1 D Voice - 2 E Voice Shield 3 F ECS RCV Shield 4 K ECS TX Shield 5 A ECS TX + 6 H ECS TX - 7 B ECS RCV + 8 J ECS RCV - 9 6

Table 8. Wiring Diagram for External RWCIU to Internal DE9 (Concluded) RS Connector Bendix 9-Pin Connector Signal MS17346R20C335 (Female) C Voice + 1 D Voice - 2 E Voice Shield 3 F ECS RCV Shield 4 K ECS TX Shield 5 A RS RCV+ 6 H RS RCV- 7 B RS TX+ 8 J RS TX- 9 VI. SAFETY AND SECURITY REQUIREMENTS The safety and security requirements are shown in Table 9. Table 9. Safety and Security s 50 Three smoke detectors shall be installed, one in each room. 51 Three fire extinguishers shall be securely mounted, one in each room. 52 The main side entrance door shall have an X-09 lock installed as well as a push-button combination lock, providing a two-step entry. 53 All outside-accessible openings (vents, and so forth) greater than 9-x-9 inches shall have metal bars preventing entry. 7

LIST OF ACRONYMS AND ABBREVIATIONS AC AMPS/amps AWG BNC CAT D-sub DVI GFE GFI GPS HDMI HDTV HVAC IAW IEEE KVM LCD PAC-3 RCA RJ RS RWCIU SC SSDD ST UPS USB UTP VAC VEST VGA Alternating Current Amperage American Wire Gauge Bayonet Neill-Concelman Category D-subminiature Digital Visual Interface Government Furnished Equipment Ground Fault Interrupter Global Positioning System High-Definition Multimedia Interface High Definition Television Heating, Ventilation, and Air Conditioning In Accordance With Institute of Electrical and Electronic Engineers Keyboard-Video-Mouse Liquid Crystal Display Patriot Advanced Capability-3 Radio Corporation of America Registered Jack Recommended Standard Radar Weapon Control Interface Unit Standard Connector System Simulation and Development Directorate Straight Tip Uninterruptible Power Supply Universal Serial Bus Unshielded Twisted Pair Voltage Alternating Current Virtual Engagement Simulation Testbed Video Graphic Array 8

INITIAL DISTRIBUTION LIST Copies Weapon Systems Technology Ms. Gina Nash Electronic Information Analysis Center gnash@alionscience.com Alion Science and Technology 201 Mill Street Rome, NY 13440 Defense Technical Information Center Mr. Jack L. Rike Electronic 8725 John J. Kingman Rd., Suite 0944 jrike@dtic.mil Fort Belvoir, VA 22060-6218 AMSAM-L Ms. Anne C. Lanteigne Electronic anne.lanteigne@us.army.mil Mr. Michael K. Gray Electronic michael.k.gray@us.army.mil RDMR RDMR-CSI Electronic Electronic RDMR-SSL-M Mr. Jeff Lyons Electronic/Hardcopy jeff.lyons1@us.army.mil Dist-1/(Dist-2 Blank)