System Requirements SA0314 Spectrum analyzer:

Similar documents
USB Mini Spectrum Analyzer User s Guide TSA5G35

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Q-Lab Software. for the 8821Q-R OPERATION MANUAL

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

DVR-431 USB Wireless Receiver User Manual

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

SNG-2150C User s Guide

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

VideoMate U3 Digital Terrestrial USB 2.0 TV Box Start Up Guide

Manual Version Ver 1.0

Transmitter Interface Program

Linrad On-Screen Controls K1JT

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Effective Test Procedures for Installing and Maintaining RF Transmitter Sites

RF Record & Playback MATTHIAS CHARRIOT APPLICATION ENGINEER

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Version Users Manual

DAC Express Release 3.4 (VT9801B)

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Precision DeEsser Users Guide

TVW750USBD ATSC Tuner Quick install manual

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

CAPTURE CAPTURE. VERSiON 1.2. Specialists in Medical. Digital Imaging Solutions

DVB-S 100 Installation Manual

Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Minimum computer system requirements for playing 3D content on a BenQ projector:

User s Guide W-E

Spike Spectrum Analyzer Software User Manual

Getting Started with the LabVIEW Sound and Vibration Toolkit

SuperSpeed USB 3.0 to HDMI Audio Video Adapter for Windows & Mac up to 2048x1152 / 1920x1200

Yellow Frog. Manual Version 1.1

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

Operating Instructions

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum.

SAGE Instruments UCTT 8901 Release Notes

SR-D8-M, SR-D8-S. (Ver ) SOFTWARE INSTRUCTIONS

ME1000 RF Circuit Design. Lab 10. Mixer Characterization using Spectrum Analyzer (SA)

Keysight FieldFox Microwave Analyzers

TransitHound Cellphone Detector User Manual Version 1.3

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Agilent FieldFox RF Analyzer N9912A

spiff manual version 1.0 oeksound spiff adaptive transient processor User Manual

Quick Start manual for Nova

MAutoPitch. Presets button. Left arrow button. Right arrow button. Randomize button. Save button. Panic button. Settings button

Introduction to S1210 EMI Pre-Compliance Test Software

PulseCounter Neutron & Gamma Spectrometry Software Manual

Fluke 190-Series II Firmware Upgrade V11.44

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

Agilent ESA Series Spectrum Analyzers

CATV & DOCSIS3.0 Meter / Analyzer. Purchase from:

Tektronix RSA306 USB Spectrum Analyzer

Quick Reference Manual

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

HD PVR MCE Support Release Notes Version /28/2010

Component Video Matrix Switcher Series ITEM NO.: YS04MA, YS04MD

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

MTL Software. Overview

USB-SA124B Spectrum Analyzer User Manual

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B. User Manual and Programming Guide

DVB-T Hybrid X8000T. PCI Card

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

RF Signal Capture & Playback Simple Operation Guide

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

USER MANUAL USER MANUAL. VIO 4K Ref. V701 PROGRAMMER S GU.

1 Ver.mob Brief guide

RXT OSA Test Module

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Immunity testing example using Tekbox TEM Cells

PicoScope 6407 Digitizer

Quick Installation Guide

Ultra 4K Tool Box. Version Release Note

Using Spectrum Laboratory (Spec Lab) for Precise Audio Frequency Measurements

R3267/3273 Spectrum Analyzers

MultiScopeLite. Users Guide. Video Measurement and Calibration Tools. RHMG Software Tools Library 1/18/2013. Bill and Scott Werba

USER S MANUAL REV 1.0 FORM# 7677

Log viewer and analyser for switchboard and downhole sensor

Manual for the sound card oscilloscope V1.41 C. Zeitnitz english translation by P. van Gemmeren, K. Grady and C. Zeitnitz

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

DVB-T USB SET-TOP BOX

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

ir32 installation files for IR receive and blaster functionality. mce the HD PVR MCE Support installer (setup.exe)

EndNote X9 Notebook - For PC users

Datasheet SHF A

PicoScope 4000 Series PC Oscilloscopes

VIDEOPOINT CAPTURE 2.1

Diogen 24/24 two-regime seismograph

VTAPE. The Analog Tape Suite. Operation manual. VirSyn Software Synthesizer Harry Gohs

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

SPL Analog Code Plug-ins Manual Classic & Dual-Band De-Essers

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

Transcription:

System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into the computer. Drag and drop the folder (RFI_SA0314) to you desktop Open folder RFI_SA0314 and double click RFiSpecAn0314.exe RFiSpecAn0314.exe is a C# program; you may need to update your.net in Microsoft if you get the error message Updating.net in Microsoft http://www.microsoft.com/en-us/download/details.aspx?id=30653

Connect hardware Insert the SA0314 into an USB connector on your pc and wait for the device driver to load you will hear 2 double beeps. The first double beep when windows detects a new device and the second double beep when the device is ready The serial # of the SA0314 will display in the upright corner of the sa0314 software. If you are running multiple SA0314 you can assign different sa0314 to different application running at the same time. Left click start This starts the sweep the frequency sweep and will repeat until told to stop.

Operation The initial parameters are Full Span, 813KHz bandwidth, reference level @ -20db, trace 1 enabled, LNA ON, markers off,10db/div Under the frequency tab you can adjust the start, stop, center, and span manually but mouse control is easier. Default reference level is for quick mouse control. Left click the mouse on the display and pull down to the left this resets the display if in a zoom display mode to the default reference level with a 100 db total scale. If 1 db/div is selected then the db/div will be the minimum that can be displayed with the window size you have selected. Span will not affected

Changing Frequency, span and reference level with the mouse. Use the left mouse button and draw a box around the signal interest (Start the box in the upper left then pull box down to the lower right) Then release the left mouse button The display will adjust Frequency, span and reference level to the box you drew.

Moving the display area. Right click and hold the mouse button while moving the mouse will move the display in frequency and reference level. (The span will change only if the start and or the stop are at the min or max value) 6. Span In and Span Out will change the start and stop frequency around the center frequency that is displayed.

Bandwidth Resolution bandwidth can be changed with the pull-down menu (58,68,81,102,116,135,163,203,232,271,325,406,464,542,650,813)KHz. Changing the bandwidth automatically turns off BW Auto. Bandwidth Average is similar to Video Bandwidth on an analog Spectrum analyzer. Step Delay will change to larger numbers for smaller bandwidths. This is a necessary delay to receive the full power of the signal in smaller bandwidth. The Step Delay can be reduced to decrease sweep time with reduced accuracy. BW Auto selected allows the software to change bandwidth depending upon the span of the display. IF Gain can be adjusted for maximum sensitivity for signals that a very weak. IF Frequency of the SA0314 can be changed if there is a strong signal at the IF frequency that is interfering at the current IF frequency of the SA0314.

Traces Trace 1 is green and trace 2 is light blue. Export data creates a text file for importing into graphing software. Max Hold will hold the selected trace maximum signal. View stops updating the selected trace.

Markers Markers are used to find amplitude at a frequency. Two markers can be used to find frequency and amplitude delta. To find the amplitude difference between two signals first enable both markers. You can use peak find on ether marker. Use the <> on ether side of peak to find the next peak or use the <> below frequency to step to the next frequency. After both markers are at the desired frequencys the delta can be read below the M1 and The M2 data in the upper left corner of the display. Center is used to center the display at the marker frequency. If you are using max hold and the frequency of the display changes then a full redraw of the maxhold will erase the old maxhold display.