Triax TechInfo. Installing and pulling Fibre Optic cables

Similar documents
Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

FIBER OPTIC CABLE PULLING

Optical Distribution Box 300 Installation Guide. Version : R0.0

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

Underground Installation of Optical Fiber Cable by Pulling

Installation of Optical Fiber

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Public Works Division Lighting District Fiber Optic Specifications April 2009

Cable Installation Tips

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Cable installation guidelines

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SPECIFICATION. Optical Fiber Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable

Cable Installation Tips

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Panduit Recommended Best Case Practice Split Fibre

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

TECHNICAL SPECIFICATION

Section Communications Optical Fiber Backbone Cabling

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Special Specification 6242 Special Fiber Optic Cable

Revision No. 4 Page No. Page 1 of 7

Fiber Optics Redefined

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

3M Fiber Optic Wall Mount Enclosure 8430 Series

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR FIBER OPTICS. ITS:CLC 1 of 11 APPR:MDW:JVG: FHWA:APPR:

SECTION 4 TABLE OF CONTENTS

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

FIBRE OPTIC CABLE SOLUTIONS

Ø 1000 * 588 mm 50 kg

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Aerial Cable Installation Best Practices

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION FIBER OPTIC STATION CABLES

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

LD Series High Performance Loose Tube Fiberoptic Cables

SPECIAL SPECIFICATION 1438 Fiber Optic Cable (Single mode and Multimode)

Crimp & Cleave Termination Instructions for SEL ST Connectors

SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

JVTEC s Cable System. with optical ground wire (OPGW) and/or fiber optic cable (FOC) JVTEC USA Inc. Luis Juarez CEO

Micro duct Cable with HDPE Sheath for Installation by Blowing

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

TECHNICAL GUIDELINE. Universal/Toneable FTTP Cable Applications Guideline. Materials Required

Target Interface / Construction Compliance Inspection Checklist

Fiber ICT. Optical Fiber Catalogue

FusionLink Central Tube Ribbon Preparation & handling procedure

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

HCS - HES Cabling Systems

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

BUILDING BROADCAST INFRASTRUCTURE

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

Fibre Optic Cable & Connector Guide

Buffer Tube Midspan Access Tool Accessing fibers in buffer tube procedure

@ Termination and Test Tools. Tools & Test Equipment Product Datasheet.

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

VITALink Taped Splice Straight Through Crimp

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

Detailed Specifications & Technical Data

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

SAT Fibre Optics. TRIAX fibre integrated reception systems - remove the limits from your installation. your ultimate connection

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Empowering businesses through innovative network solutions.

FREEDM Loose Tube Interlocking Armored Cables

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Gel-sealed in-line fiber optic closure

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Fiber Meter. Specification & User Manual

Product Catalogue. Fibre Optic Cable

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Polymer optical fibre as duplex fibre cable version with PCV or PUR sheath for PROFINET applications type B or C

Transcription:

Installation methods for both wire cables and Fibre Optical cables are similar. Fibre cable can be pulled with much greater force than copper wire if you pull it correctly. Just remember these rules: 1) Do not pull on the glass fibres. Pull on the strength members only! The cable manufacturer gives you the perfect solution to pulling the cables, they install special strength members, usually dupont Kevlar aramid yarn or a fibreglass rod to pull on. Use it! Any other method may put stress on the fibres and will harm them. Most cables cannot be pulled by the jacket. Do not pull on the jacket unless it is specifically approved by the cable manufacturers and you use an approved cable grip. (See chapter: Triax Fibre Optic Cables below) 2) Do not exceed the maximum pulling load rating. On long runs, use proper lubricants and make sure they are compatible with the cable jacket. On really long cable runs, pull from the middle out to both ends. If possible, use an automated puller with tension control or at least a breakaway pulling eye. 3) Do not exceed the cable bend radius. Fibre is stronger than steel when you pull it straight, but it breaks easily when bent too tightly. This will harm the fibres, maybe immediately, maybe not for a few years, but you will harm them and the cable must be removed and thrown away! 4) Do not twist the cable. Putting a twist in the cable can stress the fibres too. Always roll the cable off the spool instead of spinning it off the spool end. This will put a twist in the cable for every turn on the spool! If you are laying cable out for a long pull, use a "figure 8" on the ground to prevent twisting (the figure 8 puts a half twist in on one side of the 8 and takes it out on the other, preventing twists). And always use a swivel pulling eye because pulling tension will cause twisting forces on the cable. 5) Check the length. Make sure the cable is long enough for the run. It's not easy or cheap to splice fibre and it needs special protection. Try to make it in one pull. Conduit and Innerduct: Outside plant cables are either installed in conduit or innerduct or direct buried, depending on the cable type. Building cables can be installed directly, but you might consider putting them inside plenum-rated innerduct. This innerduct is bright orange and will provide a good way to identify fibre optic cable and protect it from damage, generally a result of someone cutting it by mistake! The innerduct can speed installation and maybe even cut costs. It can be installed quickly by unskilled labour remember sufficient bending diameters! - then the fibre cable can be pulled through in seconds. Page 1 of 5

Triax Fibre Optic Cables Triax TechInfo The Triax Fibre Optic Cable TFC Series (TFC01 thru TFC500) are 3.0 mm steel armored cables, perfect for protection against stepping, impact and bending in addition to provide an excellent rodent protection, but as most fibre optic cables are not perfectly suited for direct pulling. Triax TFC Series Fibre Optical Cables Following rule number 1 above to the letter, this actually means that the suggested best possible pulling is to ONLY pull on the yellow strength members, which are fixed at connectors at both ends. This requires the installer to actually cut off the FC/PC connector at the pulling end, and attach his pulling tool to the yellow yarn directly. Most installers want to prevent this, because it is somewhat directly against the idea of using pre-connected cables and obviously requires him to subsequently mount a new FC-connector in place of the cut-off one, causing extra cost, hassle and installation time. IF the installer attempts to pull the cable, by attaching his pulling-eye to the FC-connector, this is done on his own responsibility. It may actually work well, but it is important to have attention to a couple of things: 1) BEFORE you pull, ALWAYS measure and record the power thru-loss of the fibre cable to pull using an optical power meter (attenuation should be approximately 0,3 dbm per kilometer of fibre cable PLUS a slight attenuation of less than 0,3 dbm per connector). This ensures you know the cable is good before you start pulling. (Use an Optical LNB as the light source, either the one used in the installation, or an extra spare LNB you can use for end-to-end cable measurement) 2) BEFORE you start pulling, make 100% sure that the innerduct you attempt to pull through DOES NOT - anywhere along the cable - bend more than the minimum bending radius of the fibre cable (for TFC cables this is 30.0mm diameter), but a minimum of 60.0mm bending diameter is recommended. Too little bend diameter, smaller than specified minimum bending diameter (for TFC= 30.0mm) Page 2 of 5

This is because the pulling tension around corners can be very high, and a too small bending diameter, along with the pulling tension, will always cause the cable to get the same smallest bending as the duct, and put extra strain on the fibre. REMEMBER: bending a fibre optic cable more than it is specified for may not break it, but it will simply let light escape through its buffer, which is equivalent to a loss/attenuation (= it will ruin your signal and there is no way you can remove this type of attenuation once you have it unless the bend is removed again). 3) Make sure the FC/PC-Connectors fixation to the steel-armouring, and especially the yellow strength yarn buffer is tight and well fixed at the pulling end (otherwise it may slip, and the full pulling tension moves to the steel which is flexible or ultimately to the fiber, which will break) 4) Even if the pull via the connector is successful, the tension of the yellow yarn buffer, the steel armoring AND the outer grey plastic jacket, are all different, and more important: when the pull stops, the tension goes away DIFFERENT on the yarn, steel and plastic. So the result may be that tension is still on the inner cable, even if the pull has stopped. This can cause what is known as micro-bending, meaning the glass fibre wobbles inside the cable, and every little wobble causes attenuation (see below). Microbending, small wobbles cause light to escape = power loss/attenuation 5) After you have done the pulling, AGAIN do a thru-loss optical power measurement to the cable, compare to initial measurement to check if your pulling has caused any unwanted attenuation. If it did: there are ways how you can attempt to remove it again: a. Using a sharp knife, cut through the outer grey plastic jacket some 40-50 centimeters from the pulling end. Be careful: DO NOT cut the yellow yarn. This may most often release the tension between the inner steel and fibre and the outer plastic jacket, and the cable attenuation may go away - cable is now OK. In some cases it may be necessary to also cut at the other end, in case the duct you have pulled through has a bend closer to the other end, the tension attenuation problem may come from there. b. If you don t cut as mentioned above, but measure the resulting attenuation several times you may notice that the attenuation may drop slightly, or fully, after some time. This is because the pull tension between the materials are released over time, and may go back to its original state by itself (this is dependant of many things such as bendings, cable fixation through the duct, lubrication or lack of same, etc.) Page 3 of 5

c. Attenuation caused by pulling forces is almost impossible to fully predict, as it is also dependent upon what causes friction along the pulling route (a duct or innerduct), connectors, other cables, their material and friction, bending, etc. 6) Triax accepts no warranty claims for damages caused by pulling TFC cables. Optical Measurements. Generally, it is always recommended to do an optical measurement to ANY new part of Fibre Optic cables you have installed before and immediately after you install them. It helps you keep a close eye on unwanted installation attenuations caused by pulling, bending, dirt on connectors, broken fibres, etc, when and where it occurs. If you wait to measure and check until all cables are installed it may prove to be a VERY large fault-finding job to pin-point problem areas later. Always keep optical connectors protected using the provided end cap. If your splitters have not been installed at the time of cable installations, simply use a spare Optical LNB as the light source for your measurements (TOL32 Optical LNB at one end of cable level is approx +6dBm to +7dBm - and Optical Power Meter at the other end) For measuring Optical Power Levels an Optical Power Meter is needed. Any good Power Meter with a capability to measure 1310nm wavelength, and a power Level range of -18dBm to +8dBm will do. The Triax TOM010 (right) is an excellent choice that can also be used for other Fibre Optical installations (850nm and 1550nm). Any attempt to install Fibre Optical cables without doing Optical Power Level Measurements as the installation progresses are hazardous and NOT recommended. ALWAYS clean connectors. After EVERY handling of a Fibre Optical cable connector (connecting, dis-connecting, inspection, etc.) you MUST wipe clean the end face of the Optical Connector (the center white ceramic ferrule) as even small - practically invisible - dust particles can cause attenuation on the light and result in unwanted Power attenuation. Wipes, cleaning spray and cleaning pen accessories are available from Triax for this. Use them! Page 4 of 5

Fibre Inspection Triax TechInfo Tools are available from Triax that will allow you to inspect the quality of your installation in addition to the Power Meter described above: 1. TFS001, Triax FibreScope, 307683 Handheld 400x microscope to inspect the end-face of an FC/PC connector for cleanliness and damage. 2. TFT001, Test Tool, 307682 Small handheld battery powered light source using visible red light to check that light does indeed pass through the cable. Repairing broken Fibre Optical Cables If you chose to cut (or accidentally rip off) the FC/PC-connector at one (or both) ends of a Triax TFC cable, the recommended action is always to remove it, and run a new cable. If running a new cable is not possible, the recommended solution is to attach a new Triax FC/PC-pigtail cable at the end(s) using a Fibre Optical Fusion Splicer. Pigtail means that the cable has a standard FC/PC connector in one end, and an open fibre at the other end for splicing. If you do not have access to a Fusion Splicer, or do not have access to a third-party offering this service, you may use Triax Mechanical Splice Adaptors, or Triax SC/PC Field Connectors and TFB Adaptors to repair/fit the cable ends. You should be aware that the best and absolutely recommended solution is Fusion Splicing, even if you may have to pay a third-party to do it. WARNING: use of Mechanical Adaptor Splice and/or Field Mountable Connector units DOES require training, and is NOT recommended for field use if you have not had proper prior training. They will simply cause you too much hassle and time consumption if you use them only the first time you have problems in the field. IF you choose NOT to use Fusion Splicing you should take that decision in due time BEFORE you start to do any Fibre Optical Cable installations and then spend time training the use and handling of the Adaptors and Connectors first. You CAN do this training without external supervision and on your own, but expect a minimum of half a day trial and errors before you get it right and are an expert. Furthermore you should make sure to have some stock of the units available, because when you need them in the field you probably have no time for training or shipment of connectors. It is our experience that paying a Third Party Expert to do the Fusion Splicing for you in the field when needed will prove to be less expensive than trying to use the Field Adaptors or Field Connectors without prior training. Page 5 of 5