HRF-xRx RETURN PATH HEADEND SIGNAL ORGANIZATION

Similar documents
THE FUTURE OF NARROWCAST INSERTION. White Paper

The 1.2 GHz NCI solution from Technetix:

White Paper. Performance analysis: DOCSIS 3.1 cable TV headend combining systems

DOCSIS 3.1 roll Out First Lessons Learned DOCSIS 3.1 roll Out First Lessons Learned

High Density Optical Platform for FTTx and HFC

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

OPTICAL DISTRIBUTION STATION -

Crossing the. Diplex Chasm. to 85 MHz. Author: Todd Gingrass Cable & Media Solutions

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

High Density Optical Platform

Broadband System - K

MODULO - HFC YOUR SMART HFC HEADEND TOOLKIT UNIVERSAL, SMART AND EASY - DON T MISS IT THE ART OF ENGINEERING

Model GS Port Node 1 GHz with 65/86 MHz split

LYNX ULTRA Series Hubs and Baluns

BALANCING THE REVERSE PATH

FORWARD PATH TRANSMITTERS

Opti Max Nodes Digital Return System

ESTIMATING DOWNSTREAM PERFORMANCE AND DOCSIS 3.1 CAPACITY IN CAA AND DAA SYSTEMS

DVX. Digital Versatile Headend

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

Broadcast and Satellite Communications

Catv Expert

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

Headend Optics Platform (CH3000)

DOCSIS 3.1 Development and its Influence on Business

Access platforms, evolved:

This presentation will give you a general idea of the subjects on the 18 CATV-HFC seminars that are available from:

PRODUCT OVERVIEW OPTICAL NODES

Viavi ONX Ingress Mitigation and Troubleshooting Field Use Case using Ingress Expert

Radio Frequency over Glass. Passive Optical Network (PON) for EuroDOCSIS infrastructures

Cisco GS MHz 4-Way Segmentable Node

Model Features and Groups RDS-303 RDS RDS-304.2

TRFM Series RF Amplifier Module

1/31/2009. Technical highlights session PRODUCTS & SERVICES Summary. Sam Tagliavore PBN-FTTX

CHP Max Headend Optics Platform CHP CORWave II

NETWORK MIGRATION STRATEGIES FOR THE ERA OF DAA, DOCSIS 3.1, AND NEW KID ON THE BLOCK FULL DUPLEX DOCSIS AYHAM AL-BANNA TOM CLOONAN JEFF HOWE

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Deploying IP video over DOCSIS

TV Radio Multimedia. Optical Nodes, 1218 MHz and 1006 MHz amplifiers, distribution and connection technology

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

EDFA Erbium Doped Fibre Amplifier

7100 Nano ROADM. Compact ROADM-on-a-Blade with Colorless/ Directionless Add/drop Options COMPACT, INTEGRATED ROADM-ON-A-BLADE DATASHEET

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

Specialists in Hospital TV Control Systems

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

Upgrade of 450/550 MHz Cable Systems to 600 MHz Using a Phase Area Approach. Robb Balsdon Vice President, Engineering Services Rogers Engineering

Deploying IP video over DOCSIS

Key Performance Metrics: Energy Efficiency & Functional Density of CMTS, CCAP, and Time Server Equipment

WHITE PAPER. Comprehensive Node Analysis Assures Big Upstream Gains For DOCSIS 3.0 Channel Bonding

384A Adapter Installation Instructions

BACKGROUND. Big Apple Case Study 2

Symmetrical Services Over HFC Networks. White Paper

Traditional RF Splitter/Combiner and Directional Coupler User Manual

SPINNER BROADCAST EXPLANATION OF THE MULTI CHANNEL COMBINER SPECIFICATIONS

TCF: Hybrid fibre coax systems Online course specification

New DSP Family CM Sweep Feature

Performance Broadband Innovation

Fibre Optics for cable TV

Concepts and Solutions for improving the Performance of HFC Networks

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Compact EGC Fiber Deep Nodes A90100 and A90300

Advanced Return Path Alignment & Maintenance Using the 9581 SST R4

CCAP Case Study: Enabling Converged Video + Data thru Space & Power Savings

Impacts on Cable HFC Networks

DOCSIS 3.1 roll out joins 5G first indications for a successful Fixed Mobile Convergence. Dipl. Ing. Carsten Engelke ANGA, Director Technology

OmniStar GX2 Headend Optics Platform

CONTROL OF REMOTE HUBS IN ADDRESSABLE CATV SYSTEMS. Andrew E. Hospador. JERROLD SUBSCRIBER SYSTEMS DIVISION GENERAL INSTRUMENT CORrORATION

INTERNATIONAL TELECOMMUNICATION UNION

WDM Video Overlays on EFM Access Networks

Juniper Networks G10 CMTS

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Telecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components

White Paper. Fibre Optic Technologies for Satellite Communication and Broadcast Industries. By Tom Lacey Applications Engineering Group PPM Ltd, UK

Compact Mini Amplifiers Series and Series

TROUBLESHOOTING DIGITALLY MODULATED SIGNALS, PART 2 By RON HRANAC

Amplifiers STARLINE 2000 Broadband Telecommunications Distribution Amplifier [BT*/*]

newsletter 29 INTRODUCING THE WORLD S FIRST HEVC H.265 METER & TV ANALYSER

Broadband System - D

Reverse Sweep and Balance

2015 OPTICAL TRANSMITTERS

C-band Wavelength Plan for 10G EPON Downstream

Product Flyer. Opti Max 41xx Series Fully Segmentable Node. Opti Max GHz 4 x 4 Segmentable Node. Generate New Revenue

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

Compact EGC Amplifier Model 93250

DOCSIS 3.1 Full channel loading Maximizing data throughput

Review of the Comcast. Fort Collins Cable System. Technical Characteristics

MIGRATION TO FULL DIGITAL CHANNEL LOADING ON A CABLE SYSTEM. Marc Ryba Motorola Broadband Communications Sector

a simply perfect network. OptiCal networks Ed

coaxial passives & accesories

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

A Programmable, Flexible Headend for Interactive CATV Networks

SYSTEM DESIGN - NEXT GENERATION HFC

Optical Component Environmental Test System

Datasheet. Shielded airmax Radio with Isolation Antenna. Model: IS-M5. Interchangeable Isolation Antenna Horn. All-Metal, Shielded Radio Base

End of Life. Optical Node Series (HL2) HLN3144. HL2 Series PWRBlazer Scalable Optical Node FEATURES PRODUCT OVERVIEW. arris.com

MAPON digital video distribution in the European ACTS CRABS Project: simulation and experiment

1 GHz Magnamax series

RF connectivity solutions guide

Introduction. Fiber Optics, technology update, applications, planning considerations

Transcription:

RETURN PATH HEADEND SIGNAL ORGANIZATION BACKGROUND In order to improve the service quality, e.g. the upload data speed, CATV service providers have to decrease the subscriber number of each optical segments. This can be done by increasing the number of segments in other words by using more return path transmitters (or complete nodes) on the field and more return path receivers at the headend station. However it seems to be sufficient to serve the new receiver outputs by new CMTS ports, the problem can be in many cases more difficult, because the devices providing the additional services (element management, VoD, measurements etc.) must be connected to all the receivers or at least to a group of receivers. In case of headend rack cabinets working since many years can occur the situation, that free space is strongly limited, so the solution has to be as small as possible, further it has to dissipate the lowest energy in order to minimize the additional heating and the OPEX as well. THE COMTE SOLUTION Comtech has developed a whole product family called HRF-R, which allows to match the signal levels between the output of the optical receiver and the inputs of each return path RF devices (CMTS, monitoring gateway etc.), provides combined ports for low data speed services and enough individual, uncombined outputs for high data speed services and measurements. 3 main types are available, 1 for serving 4 optical segments (HRF-OR4), 1 for serving 8 optical segments (HRF-OR8) and 1 for serving 4 coaxial segments (HRF-RR4). Serving a higher number of segments is also possible by cascading the devices a special further unit (HRF-C) can combine the output signals of pieces of same or different elements of the solution providing the same optimal level relations at it's output as an individual HRF device. Each device of the family (including also the HRF-C extension combiner) needs only 1 U height in the cabinet using less space than the conventional solutions, and complies the DOCSIS 3.1 requirements from the bandwidth and from the isolation side as well. Figure 1 1/6

SERVING 4 OPTICAL SEGMENTS An HRF-OR4 device can handle 4 return path optical segments by itself. Each input has to be connected to an output of a return path optical receiver. The individual signals of the optical receivers will appear on 4 outputs per input port, with a relative level of -24 db this attenuation is needed between an average receiver output and an average CMTS/CCAP input in order to avoid overload. These individual ports forward the signal to the CMTS/CCAP, to the spectrum analyzer to a local video receiver (in case of security cameras or remote local TV studios) and can act as free testpoints too (figure 2). The device has 2 combined outputs with the same relative levels of -24 db for monitoring gateways (HMTS) with 2 different frequency upstream carriers. The 1 U housing provides enough space for an additional 2x2 combiner too. This makes possible to combine 2 HRF- OR4 devices without external devices. To achieve the ideal -24 db relative level at both of the 2x2 combiner outputs, the device has a high level (-17,5 db) output, this has to be connected to the combiner. If more than 2 devices have to be combined, the another high level (-14 db) output must be used, this provides the level needed by the HRF-C device, which can be combine pieces of HRF-R devices with relative output level of -24 db related to the receiver output. The HRF-OR4 is a fully passive device, so it draws no powering costs and additional heating. 1 HRF-OR4 2 HIGH LEVEL COMBINED OUTPUT FOR EXTENSION (FURTHER COMBINING) CMTS/ CCAP SPECTRUM- LOCAL VIDEO FREE TESTPOINTS PASSIVE DEVICE! Figure 2 2/6

SERVING 8 OPTICAL SEGMENTS Serving 8 optical segments is possible by using the HRF-OR8 device of Comtech. The work of this unit is very similar to the work of HRF-OR4, and it provides the same ideal level relations as the HRF-OR4. The differency (beside the number of input ports) is that HRF-OR8 allows to frame clusters from 4 ports. The individual outputs (the number of them is 2 in case of this type) and the combined outputs are also available. This is useful, if service provider would like to reuse the same monitoring carrier frequency in 2 groups of segments. The combined outputs can be used in this case for serving telemetry receivers or PPV processors (figure 3). The further combining of combined signals arriving from HRF-OR8 (or other) devices by an HRF-C is possible in this case too, the HRF-OR8 provides a high level output (relative level of -14 db) for this purpose. The HRF-OR8 is a fully passive device, so it draws no powering costs and additional heating. 1 2 HRF-OR8 TELEMETRY PAY-PER-VIEW PROCESSOR HIGH LEVEL COMBINED OUTPUT FOR EXTENSION (FURTHER COMBINING) CMTS/CCAP SPECTRAL- PASSIVE DEVICE! Figure 3 3/6

SERVING 4 COAXIAL SEGMENTS Serving coaxial segments is a little bit more difficult, than serving optical segments, because in this case the forward path and the return path is not divided into 2 different media (like 2 optical fibres at least at the output of the WWDM filter). To solve this problem, the HRF-RR4 contains 4 pieces of diplex filters (splitting frequency depends on the customer's decision). Regarding to this the device has 4 bidirectional ports for launching the coaxial stretches towards the first amplifier. To all the ports belongs an individual forward path input, these inputs drive the signal of the forward path signal organizers to the outside plant. The work of the return path section is similar to the work of the HRF-OR4, there are 4 individual outputs of -24 db per bidirectional port, 2 combined outputs with the same ideal relative level, a high level output for the HRF-C external combiner and a medium level output for driving the built-in 2x2 combiner if needed (figure 4). The HRF-RR4 ensures the optimal signal levels by using amplifier stages. The total power consumption is 1 W. COMBINED FORWARD PATH SIGNALS (DVB-C + PAL + HSD + OTHER NARROWCAST) 1 HRF-RR4 2 HIGH LEVEL COMBINED OUTPUT FOR EXTENSION (FURTHER COMBINING) CMTS/ CCAP SPECTRUM- LOCAL VIDEO FREE TESTPOINTS Figure 4. 4/6

SERVING SEGMENTS UP TO A NUMBER OF 512 As mentioned in the previous sections, all the main elements have a high leveled extension port, which can be connected to the HRF-C extension device. This unit not only combines all the signals arriving to the inputs, but realizes also partial combining for groups of 4 inputs ( or 32 segments) and for groups of 8 inputs (32 or 64 segments depending on the type of the connected main element). In case of using pieces of HRF-OR8 and a single HRF-C 128 optical segments can be handled on 17 U height in the cabinet. In order to achieve the same capabilities for 512 segments as in case of the HRF-D forward path solution, also HRF-C has an extension port, which can be connected to a 4-way splitter. At the output of this device appears the same ideal signal level as on the main outputs of the HRF-C. The space requirement of this constellation is 68 U + a 4-way splitter. The modular construction of the system (i. e. the same input-output level relations) allows very high flexibility by handling mixed systems of strongly and slightly segmented areas as well as optical and coaxial segment groups (see the example on figure 5). COMBINED FORWARD PATH SIGNALS COAXIAL SEGMENTS No.1 (HRF-RR4) No.2 (HRF-OR4) HRF-C No.1 COMBINED SIGNAL No.2 (HRF-OR4) 4 8 OF MAXIMUM 512 RETURN PATH SEGMENTS OPTICAL SEGMENTS HRFM-SP4 64 No.64 (HRF-OR8) HRF-C No.4 4 8 CMTS/ CCAP SPECTRAL TELEMETRY LOCAL VIDEO IPPV PROCESSOR LAYER 1 LAYER 2 Figure 5. 5/6

The HRF-C provides the ideal signal levels by using active gain stages. The total power consumption is 4 W. USER DEFINED UNITS On customer request Comtech gladly modifies the existing units in order to pass the solution to a given network. A really good example for this is the OR8-T type. At this device modified signal level relations (-20 db instead of -24 db) are used, further the device contains testpoints for all the inputs. Regarding to the needs, the input and output ports are placed on different sides of the housing. USE, ALIGNMENT The elements of the product family have a construction, that is able to receive signal levels, which are in the output level range of the return path optical receivers. If this condition is fulfilled, the output will automatically provide levels, which are expected at the input of the RF headend devices, so the devices do not need alignment. KEY BENEFITS OF OUR SOLUTION Very low space requirements (1 U for 8 segments, 17 U for 128 segments, 68 U + SP4 for 512 segments) Flexible use (high number of various devices can be connected to an arbitrary number of segments) No or only a little external cabling is needed No alignment is needed Flexible mechanics (front and rear plate are interchangeable by adequate montage of mounting handles) 6/6