Staying Connected in GC

Similar documents
Bruce Quimby. Agilent Technologies October 28, For Forensic Use. Page 1

Liquid Chromatography- Mass Spectrometer Manual

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

Achieving More Efficient Data Review with OpenLAB CDS

GCxGC Comprehensive Two-Dimensional Gas Chromatography

SmartMix Manual V5350A

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Finnigan PolarisQ User s Guide. PN , Revision D

SECTION 4 TABLE OF CONTENTS

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

PAL LSI - Robust and Reliable Sample Handling

PAL LSI - Robust and Reliable Sample Handling

UNITY 2 TM. Version 1.0. February 2008

GC/LC-MS: data acquisition rate and peak reconstruction

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Operation Manual for the Refractive Index detector VE-3580

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

AIM INTRODUCTION SIMPLIFIED WORKFLOW

SPECIFICATION. Spec No : VSS-1402-CS603B

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity

Agilent 7000 Series Triple Quadrupole GC/MS System

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

SPECIFICATION NO Model 207 Automatic GTAW Welding System

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

TECHNICAL SPECIFICATION

NMR. picospin. Maintenance Guide

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Swagelok Ultra Torr based feed through design for coupling optical fibre bundles into vacuum systems

SPECIFICATION NO NOTE

Signet 2250 Hydrostatic Level Sensor

ACTIVE IF SPLITTER/COMBINER UHP-IFS

Karl Heinz Feller. Arbeitsgruppe Instrumentelle Analytik FB Medizintechnik und Biotechnologie Ernst-Abbe-Fachhochschule Jena.

Control Unit CU 2.1 User Manual V6850A HPLC

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

2178-L/S Series Fiber Optic Splice Case with Gasket

Preventing Fieldbus Physical Layer Problems

COHERENCE ONE PREAMPLIFIER

Integration of the Zetasizer µv and OmniFACE into an SEC system

SMA One Piece Semi-Rigid Connectors

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

ICS-3000 System Installation Qualification

PANEL RADIATORS - TECHNICAL MANUAL

Bartels Micropumps. ( ) Rev. 2.8

Identifying and avoiding common errors in RF calibration.

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

Nominal Feet Feet List Price Pipe Item # I.D. x Length O.D. Per Bag Per Crate Per 100 Feet

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3528-2PIN-SMD LED. White LED. Lumimicro 3528 One Chip Specification Doc. No: LUMI P SPEC.

RF/Microwave Connectors & Cable Assemblies

Non Magnetic Connectors

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

MAGNETIC CARD READER DESIGN KIT TECHNICAL SPECIFICATION

MCX - 75 Ohm Connectors

MU Connector Series. Single Mode Small Form Factor Connector. qhigh quality, high precision Ø qinternational standard IEC FEATURES

SMA - 50 Ohm Connectors

1.8 METER SERIES 1183 Az/El MOUNT ANTENNA SYSTEM

STANDARD OPERATING PROCEDURE:

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SLiC Fiber Aerial Closure System

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Magnum GCMS Training and Operating Instructions 02/07/2012 S.V.

CHIMEI INNOLUX DISPLAY CORPORATION

PC BOARD MOUNT DISPLAYS

Prisma Optical Networks Ancillary Modules

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

BTC and SMT Rework Challenges

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES TNC (CABLED), PIN CONTACT, RIGHT ANGLE, CLASS 2)

SHARP Plasma inverter cutting range

Standard Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography

VPM2. Operation Manual

MTS/T-BERD 8000 Platform

Printed: File: RI2012 V1.02 english doc Last modified: Makowski

Optical Cryostat - Economy

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Here's What's New from Varian, the Multi-Product, Quality Instrument Company.

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Introduction to Fiber Optic Cable Technology Jerry Bednarczyk, PE Course Content

Pressure transmitter COMPACT IO-Link,

PRESTOJET Plasma inverter cutting range

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE Test Method for Cable Weld Integrity

If you have questions or problems in providing anything described as Customer

LG OLED Light Panel. Flexible panels

Vertical deduster Vibration dedusting Gentle deburring Vertical transport

NGC8206 Start-Up Guide

FOSC 450 C6 and D6 Closures

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

IMPAC Infrared Thermometers

Transcription:

Staying Connected in GC Daron Decker / Eric Pavlich Chromatography Technical Specialists Page 1

Leaks (Oxygen) Damages GC Columns Repair of the GC column is impossible Replacements means re-calibration Replacement means delay Replacement column costs money Solution = No Leaks! Page 2

Installing a GC Column Can Be Challenging A routine, basic procedure but not easy to do Plus a minimum of 2 chances to get it wrong! Very small parts Wrenches in cramped, dark space Even when done correctly, fittings can still leak (shrinking ferrule syndrome) Page 3

Ferrules Graphite/Polyimide Graphite Flexible Metal 350 C Limited re-use Shrinks in temp cycles Needs retightening Prone to leaks Inlets MS, ECD 450 C Limited re-use Permeable Contamination Flaking Inlets FID, NPD HT Applications 450 C No re-use No damaged surfaces Pricy CFT devices Backflush

What if you Could install the column easily Finger tighten, without tools that cause over tightening And make leak free connections Which don t need to be retightened Every time? Page 5

Self-Tightening Column Nuts Innovative spring-driven piston continuously presses against ferrule Less wasted time: No retightening needed after repeated thermal cycles Ease of use: Finger-tight, consistent connections without tools Leak Free = Lower column bleed: Longer column life Video at agilent.com/chem/stnutvideo Page 6

Self Tightening Column Nuts For inlet or detector p/n 5190-6194 For mass spec transfer line p/n 5190-5233 Page 7

Solving Shrinking Ferrule Syndrome Page 8

What to Use When? Application Requirement Ease of Use - finger tighten / no wrench Inertness for active analytes Installed or used hardware Self Tightening Column nut with short Graphite/Polyimide blend ferrule x x UltiMetal Plus Flexible Metal ferrule Same style ferrule at inlet and MS interface x High temp above 350 x Mass Spec Interface fitting x Capillary Flow Technology device x Pre-swage for precise height into fitting x x Re-use of ferrule x x

Ferrule Pre-swaging Tools Ensures proper length of column into the fittings, every time For graphite or metal ferrules Metal ferrule tool Graphite ferrule tool G3440-80218 G3440-80217 Page 10

Newest Pre-swaging Tool Coming Soon for CFT Devices! Page 11

Other Connections in GC Guard Columns, Pre-Columns Capillary Flow Technology - Backflushing - Multiple Columns/Detectors - Deans Switch Page 12

Splitless Injection Reverse Solvent Effect Hexane 5 6 Methanol 4 1 4 2 5 6 2 3 1 3 0 1 2 3 4 5 6 Time (min.) 1 2 3 4 5 6 Time (min.) DB-1, 15 m x 0.25 mm I.D., 0.25 µm 50 C for 1 min, 50-210 C at 20 /min; Helium at 30 cm/sec 1. 1,3-DCP 2. 3-hexanol 3. butyl acetate 4. 1-heptanol 5. 3-octanone 6. 1,2-dichlorobenzene Page 13

Retention Gap Also Called A Guard Column Injector Detector Deactivated Fused Silica Tubing Union Column Usually 2-10 meters long and same diameter as the column (or larger if needed) Page 14

Fixing the Reverse Solvent Effect 3 m x 0.25 mm I.D. Retention Gap Hexane 1 Methanol 4 5 6 2 3 4 1 2 3 5 6 0 1 2 3 4 5 6 Time (min.) 1 2 3 4 5 6 Time (min.) DB-1, 15 m x 0.25 mm I.D., 0.25 µm 50 C for 1 min, 50-210 C at 20 /min; Helium at 30 cm/sec 1. 1,3-DCP 2. 3-hexanol 3. butyl acetate 4. 1-heptanol 5. 3-octanone 6. 1,2-dichlorobenzene Page 15

Press Fit Connectors Competitor Press-Tight Agilent Ultra Inert Press Fit Inertness, seal and transparency are key parameters Page 16

Pull Test Machine: ASTM Test Used in Packaging Page 17

Column - press-fit connector pull test Page 18

Maximum Force Required to pull apart 2.5 Pull Value, 0.25 mm I.D. Columns Pounds (force) 2.0 1.5 1.0 Strong bond between FS polyimide & press fit UI deactivation layer 0.5 0.0 1 2 3 4 Ultra Inert Quartz Fused Silica Glass Press Fit Connector Type Page 19

1.4E+00 Pull Value, 0.53 mm ID Columns 1.2E+00 1.0E+00 Bond strength also dependent on contact angle and contact surface area Between polyimide and press-fit 8.0E-01 6.0E-01 4.0E-01 2.0E-01 0.0E+00 1 2 3 UI Qtz FS Page 20

Ultimate Union and Retention Gap (Preferred by Many) Page 21

Two Connection Options from Agilent Ultra Inert Press Fit Connectors Capillary Flow Technology Page 22

Purged Capillary Flow Devices 2-Way Splitter with Makeup 3-Way Splitter with Makeup Deans Switch Purged Union (most recent) All Purged Capillary Flow Devices are Capable of Backflushing Page 23

Backflush with Purged Union or Any Purged Capillary Flow Technology Device Split Vent Trap During GC Run Aux EPC 4 psi Inlet MSD 25 psi Split Vent Trap Column After GC Run Purged CFT Device Aux EPC 80 psi Inlet MSD 1 psi Column Purged CFT Device performance turbo recommended Page 24

Milk Extract It took additional 33 mins and column to 320 o C to remove these high boilers. Run stopped at 42 min and backflushed at 280 o C for 7 mins. Blank run after backflushing showing the column was clean. 5 10 15 20 25 30 35 40 45 50 55 60 65 70 min Page 25

Post-Column Backflush Injector Detector Transfer Line Column Purged Ultimate Union

Mid-Column Backflush Injector Detector Column Front Half Back Half Purged Ultimate Union

Pre-Column Backflush Injector Detector Pre-Column Column Purged Ultimate Union

Without Backflush: A Serious Problem Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by MSD user in Almeria, Spain After only 3 10-µL injections, the background is significantly higher (increase chemical noise is every spectrum) 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 29

With Backflush: No Increased Background (Less Spectral Noise) and Consistent Retention Times Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time TIC: lettuce_10_ppb.d\data.ms TIC: lettuce_100_ppb.d\data.ms TIC: lettuce_5_ppb.d\data.ms Data provided by user in Almeria, Spain Stable retention times and baseline... less chemical noise 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Overlay of three chromatograms of lettuce extract run with 2 min of back flush Page 30

Conclusions Never have a leak (no oxygen) Self-Tightening Nuts - solves shrinking ferrule syndrome. Ultra Inert Press Fit Connectors the most cost effective and more reliable than previous press tight connectors. CFT and Ulti-Metal FMF - the most reliable, but pricey. Guard columns, pre-columns, multiple columns/detectors, and backflushing all now possible with reliable, leak-free connections. Page 31

Agilent Better GC Connections www.agilent.com/chem/bettergcconnections Order the poster View the video