R-1550A Tempest Wide Range Receiver

Similar documents
R-1580A Microwave Downconverter. Product Brochure

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Agilent 5345A Universal Counter, 500 MHz

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Technical Description

ThinkRF D GHz RF Downconverter

Advanced Test Equipment Rentals ATEC (2832)

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

MULTIBAND 1/3 RACK-MOUNTED

SYNTHESIZED COMMUNICATION CONVERTERS

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

High-Value 100 Series (Outdoor)

1/3 RACK-MOUNTED BLOCK CONVERTERS

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

R3267/3273 Spectrum Analyzers

Inmarsat Downconverter Narrowband Downconverter

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Modular Block Converter Systems

L-Band Block Upconverter

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

MTP200B WLAN / BT LE Tester

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Full-featured CW Microwave Counters for Field, Factory or Lab

Spectrum Analyzers. 2399A 9 khz to 3 GHz Spectrum Analyzer.

Indoor Dual Converter

R&S FSV-K40 Phase Noise Measurement Application Specifications

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Microwave Counter, Power Meter and DVM in One Portable Package

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Noise Detector ND-1 Operating Manual

SMS3000X Series Spectrum Analyzer

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

R&S FPC1000 Spectrum Analyzer Specifications

Synthesized Clock Generator

DA : Series of Narrowband or Wideband Distribution Amplifiers

VXIbus Microwave Downconverter


1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

FCC ID: IMK-ILCISA EMI TEST REPORT

DA E: Series of Narrowband or Wideband Distribution Amplifiers

clipping; yellow LED lights when limiting action occurs. Input Section Features

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Application Note DT-AN DTU-315 Verification of Specifications

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Signal Stability Analyser

2019 Product Guide. For more information, contact: Midwest Microwave Solutions, Inc Progress Drive Hiawatha, IA 52233

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

QRF5000 MDU ENCODER. Data Sheet

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Agilent 8560 E-Series Spectrum Analyzers

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Keysight Technologies E5500 Series Phase Noise Measurement Solutions

Advanced Test Equipment Rentals ATEC (2832)

Product Brochure Version R&S TSML-CW Radio Network Analyzer Powerful scanner for CW applications

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

C-Band Redundant LNB Systems

E4416A EPM-P Series Single Channel Power Meter

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

RF Explorer RackPRO. User Manual. Introduction. Greetings fellow traveler on the RF spectrum.

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

8650A SERIES UNIVERSAL POWER METERS

Agilent Series Preselected Millimeter Mixers

3GHz Spectrum Analyzer

JD725A Cable and Antenna Analyzer - Dual Port

Version 1.10 CRANE SONG LTD East 5th Street Superior, WI USA tel: fax:

Instrumentation Grade RF & Microwave Subsystems

INTEGRATED ASSEMBLIES MICROWAVE SOLUTIONS FROM TELEDYNE COUGAR

X-Band Redundant LNB Systems

Satellite Up- and Downconverter

Ku-Band Redundant LNB Systems

Agilent 4-Port PNA-L Microwave Network Analyzer

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Agilent CSA Spectrum Analyzer N1996A

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

DQT1000 MODEL DIGITAL TO QAM TRANSCODER WITH DIGITAL PROCESSING AND MULTIPLEXING

Transcription:

R-1550A Tempest Wide Range Receiver Product Brochure Version 0.2.00 April 2008 Dynamic Sciences International, Inc.

R-1550A TEMPEST Wide Range Measurement Receiver Made specifically for TEMPEST testing requirements, the enhanced TEMPEST Receiver provides the user with all of the necessary resources to conduct TEMPEST monitoring and measuring. The R-1550A TEMPEST Receiver includes everything a user needs to operate from a frequency range of 100 Hz to 2 GHz. With options, the frequency range may be extended as low as 20 Hz or as high as 40 GHz. The R-1550A Receiver is available for lab use and/or is available with a customized shockmounted travel case. STANDARD R-1550A TEMPEST RECEIVER IF BANDWIDTHS: 50 Hz, 100 Hz, 200 Hz, 500 Hz, 1 khz, 2 khz, 5 khz, 10 khz, 20 khz, 50 khz, 100 khz, 200 khz, 500 khz, 1 MHz, 2 MHz, 5 MHz, 10 MHz, 20 MHz, 50 MHz, 100 MHz, 200 MHz. ADDITIONAL R-1550A TEMPEST RECEIVER IF BANDWIDTHS: An expanded bandwidth set below 20 khz may be selected from the Receiver front panel. The following bandwidths are available to manually select: 250 Hz, 300 Hz, 400 Hz, 640 Hz, 800 Hz, 1.3 khz, and 1.6 khz, 2.5 khz, 3 khz, 4 khz, 6.4 khz, 8 khz, 9 khz, and 13 khz. The R-1550A can be used as a standalone receiver or as part of our DSI-1550A TEMPEST Test System. Low frequency measurements and the low bandwidths are generated in the system software when you configure the R-1550A TEMPEST Receiver as part the DSI-1550A system. The additional software generated bandwidths are 1 Hz, 2 Hz, 5 Hz, 10 Hz, and 20 Hz. The DSI- 1550A TEMPEST System, with a frequency range of 20 Hz to 2 GHz, includes an R-1550A TEMPEST Receiver, an R-1560 System Interface Unit, and the DSI-1550A system software installed on a fully integrated computer system. An optional Microwave Downconverter (MDC) is available to increase the upper frequency range from the standard 2 GHz to either a maximum of 22 GHz or 40 GHz, depending on which MDC model the user requires to add to the DSI-1550A-2 configuration.

SELECTABLE TUNING RESOLUTIONS: Using the arrow keys on the display the user can tune the digits on a receiver selecting a digit to perform manual step tuning. The step size is determined by the selected digit. The tuning knob also tunes at the selected digit. Frequency Resolution is 0.1 Hz from 100 Hz to 250 khz; 1 Hz from 250 khz to 15 MHz; and 100 Hz from 15 MHz to 2 GHz. SYNTHESIZER DESIGN: Synthesizer design provides a programmable frequency control. Any frequency may be entered from the keypad with up to seven digit resolution. AM/FM DETECTOR SWITCH: It automatically selects audio source. Gain controls are provided for headphone use. AUXILIARY VIDEO OUTPUT: For Z-axis display; provides a direct connection for video monitoring use. Z-AXIS OUTPUT: Provided on the rear panel for rastering of repetitive signals. Automatic remote mode selection is provided by the host computer. LOW NOISE FIGURE: The nominal noise figure is 6 db. The noise floor in a 100 Hz bandwidth is -41 dbμv. The noise floor in a 10 khz bandwidth is 21 dbμv. There is 80 db image rejection over the entire frequency range. The noise floor will improve by at least 6 dbųv when the R-1550A Receiver is configured in the DSI-1550A TEMPEST Test System. PRESELECTION FILTERS: There are nine bandpass filters that may be individually selected during tuning corresponding with the receiver band and the tuned frequency. Filter values are 200 MHz Low Pass, 200-350 MHz, 350-550 MHz, 550-750 MHz, 750-1000 MHz, 1100 MHz Low Pass, 1.0 GHz-1.3 GHz, 1.3 GHz-1.6 GHz, and 1.6 GHz-2.0 GHz.

R-1550A Specifications Receiver Frequency Range: 20 Hz to 2 GHz (extendable to 22 GHz or 40 GHz with the R-1580A/R-1584A Microwave Down converter) 100 Hz to 2 GHz in 4 Bands Receiver gain in 1dB steps Input Attenuator: 0-100 db in 1 db steps IF Bandwidths: 35 BW from 50 Hz to 200 MHz Band 1 Band 2 Band 3 Band 4 100 Hz to 250 khz 250 khz to 15 MHz 15 MHz to 1 GHz 1 GHz to 2 GHz 1:2:5 sequence Detection Modes: AM/FM/CW DVM: Measurement Precision: For SNR>10 db, 4 db (uncalibrated), 2 db with calibration sources Sensitivity: Typically 6 db above Johnson noise Noise Figure: Less than 10 db (8 db typ. in mid-range) IF and Image Rejection: At least 80 db Spur-free Dynamic Range: Better than 60dB Frequency Stability: 1 ppm per year Autoranging: Peak-hold, 100 MHz BW, 12 bit A/D, 4-digit DVM display and LED BAR IF Output: 1450 MHz, 21.4 MHz Video Outputs: AM (peak) and FM, Linear/Log, Aux video with pulse stretch/slideback Audio: >1 Vrms; + 3 db, 20 Hz-20 khz Power: 120 watts 115/230 50 or 60 Hz Mechanical: Receiver has side handles and collapsible feet (front); rack mount kit available. Selectable - uses 100dB 10dB step attenuator

Weight: 44 lb. (20 kg) Power: 100 Watts typical 15/230V 50 or 60 Hz Video Output Level (into 50 Ohms): AM: 3.0 Volts (10V Aux.) M: 1.0 Volt P-P Nominal Audio Gain Control Range: 40 db SPURIOUS RESPONSE: >= 120 dbm INPUT VSWR: 2.1 maximum Maximum tolerated RF Input: CW (rms): 0.5 watt Peak: 1,000 watts 1 usec 1 khz PRF IF Shape Factor: Nominally 4:1 (60 to 6 db) IF Output Center Frequencies: 21.4 MHz and 1450 MHz IF Output Level (into 50 ohms): +10 dbm AGC Modes: Off, Fast, Slow Audio Output Level: 2.5 Volts (rms) into 8 Ohms Preselecting filtering: >Automatic selection as a function of tuned frequency AM Detector Dynamic Range: 30 db to 35 db Clock Frequency Stability (aging rate): 5 x 10 8 per year Clock Frequency Stability Offset vs Temperature: 5 x 10 8, 0 to 35 o C Operating Frequency Stability: After 30 minutes warm-up, stability is equal to clock stability MTBF: >3500 hours calculated >4000 hours field experience Interface: IEEE-488

RECEIVER SYSTEM CONNECTIONS RF Input Connectors: 50 Type N Signal In Type N Calibrate In Type BNC Signal In (Low Freq.) Type BNC Calibrate In (Low Freq.) Video/IF: BNC, 50 Instrumentation: GPIB IEEE-488.2 bus Power: 100 watts typical 115/230V 50 or 60 Hz

Optional Equipment R-1584 Microwave Downconverter - 40GHz R-1580 Microwave Downconverter -22 GHz IG-1000 Impulse Generator RG-1000-A Raster Generator CG-1000 Comb Generator R-1560 I/O Controller Industrial PC with DSI-1550A software SSIU-Spread Spectrum Detection Unit Panoramic Display Unit Narrowband Audio Processor R-1150-A Antenna Kit

Dynamic Sciences International, Inc. 2008 Printed in the USA, April 28,2008 www.dynamicsciences.com 6130 Variel Avenue Woodland Hills, CA 91367 Tel: 818-226-6262 Fax: 818-226-6247 Email: market@dynamicsciences.com