Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Challenges for testing 10GBASE-T

What really changes with Category 6

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Alien Crosstalk measurement limitations at low frequencies (1 MHz to ~ 10 MHz)

Do you know if your Cat. 6 patch cord has been tested according to standards?

SYSTIMAX GigaSPEED XL Solution

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Belden IBDN System 10GX The next level of cabling performance

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

Belden IBDN System 10GX Enabling Technologies

Everything you always wanted to know about HDBaseT*

Connect with the industry s best CAT6 and CAT5e channel solutions!

The University of Texas at Austin September 30, 2011

How to accelerate your cabling system approvals

OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Copper Cabling Troubleshooting Handbook

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

RCIT Cable Certification Testing Revised 10/2017

DESIGN!!GUIDELINES!!!!!

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

Class E A / Cat.6A Screened Coupler

SECTION COMMUNICATIONS HORIZONTAL CABLING

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

SECTION TESTING OF COPPER CABLES

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

MODEL NUMBER SRP-X700P

Agilent 81600B Tunable Laser Source Family

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

DSP-4000 Series. CableAnalyzer. Users Manual

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SONy BID SPECIFICATION FOR POWERED MIXER MODEL NUMBER SRP-X500P

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Volition TM RJ45 K5e Jacks

BLONDER TONGUE LABORATORIES, INC.

Interface Practices Subcommittee SCTE STANDARD SCTE Hard Line Pin Connector Return Loss

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

ENGINEERING COMMITTEE

CAT6Plus System. Brand-Rex Limited

JD725A Cable and Antenna Analyzer - Dual Port

HDM-4X2. Installation Manual. HDMI Matrix Switcher. HLE-1 RX HDMI Extender with HDBaseT-Lite. HDMI Out. IR In. Receiver.

Clarity Advanced Solutions6A

384A Adapter Installation Instructions

PREMIUM 5e F/UTP PRODUCTS

OTR-3550 FREQUENCY AGILE - F.C.C. COMPATIBLE TELEVISION PROCESSOR INSTRUCTION MANUAL

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

CAT EXT-CAT USER MANUAL

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

SMART CLASSix 24/48 UTP Patch Panels -

Long Range Ethernet Extender

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

User Manual. Model HCX-11 HDMI Coax Extender. Five-Coax Extender Model HCX-11. Five-Coax Extender Model HCX-11

Sidelighter TM Optical distance to fault measurement module

TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Colour Explosion Proof Video Camera USER MANUAL VID-C

Testing. Maker Works. Applicant: Model No.: FCC ID: Jun., May to 16. Date of Test: PASS* Test Result: Signature: Authorized. this report.

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

25% OFF Genuine Amphenol Coaxial Cables

SECTION 686 VIDEO DECODER DESCRIPTION

RF Characterization Report

Fieldbus Testing with Online Physical Layer Diagnostics

In-Line or 75 Ohm In-Line

Advanced Test Equipment Rentals ATEC (2832)

New DSP Family Traffic Control Plus Feature

LCM-550x12 12 CHANNEL TELEVISION MODULATOR SYSTEM INSTRUCTION MANUAL

By Jim Norton Bird Technologies Group Applications Engineer

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

3M 8900 Single-mode SC Crimplok Connector

Vocoder Reference Test TELECOMMUNICATIONS INDUSTRY ASSOCIATION

NV Series PA Modification for Improved Performance in FM+HD and HD Modes

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Installation Note. Agilent 89441A Option AYC Installation Kit

Savant. Savant. SignalCalc. Power in Numbers input channels. Networked chassis with 1 Gigabit Ethernet to host

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

BID SPECIFICATION FOR PRODUCTION CRT MONITORS

Transmission of High-Speed Serial Signals Over Common Cable Media

CABLE LOSS MASKING EFFECT

Transmission of High-Speed Serial Signals Over Common Cable Media

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS Projector, Camera and Veteran s Project

OTM-3000-I FREQUENCY AGILE TELEVISION MODULATOR PAL I STANDARD INSTRUCTION MANUAL

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Agilent 87075C Multiport Test Set Product Overview

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Analog Dual-Standard Waveform Monitor

Transcription:

The Effect of Short Link Resonance on the NEXT and PSNEXT Performance of 7m Channels Data Communications Competence Center DCCC082102R1 July 11, 07 Test Summary This report compares the results of NEXT and PSNEXT testing for seven meter Category 6 channels. Channels consisting of components from five connector manufacturers and five cable manufacturers were evaluated against the requirements of ANSI/TIA/EIA-568-B.2-1-02. These results are compared to those of the Berk-Tek/Ortronics NetClear GT2 solution. All testing was performed using commercially available handheld testers. Background It is commonly assumed that the worst-case cabling system performance occurs on channels that consist of four connectors at a length of 100 meters. Contrary to this assumption, NEXT and PSNEXT performance margins are worse on short channels. The difference in performance of these short channels can result in failures in the field, more time spent on testing and troubleshooting and higher installation costs. The short link phenomenon was first observed with Category 5 cabling. Also known as short link resonance it is caused by accumulative signal imbalances and additive noise that comes from two connectors that are in close proximity to each other. Short link resonance was most apparent in installations with less than 15 meters (49 feet) between connectors. Since then, improvements were made in the design of Category 5 components. This helped to minimize the problem. In addition, manufacturers have incorporated minimum link distance requirements or specific patch cable lengths into their warranty programs. Short link resonance has become an issue again with the introduction of Category 6 cabling systems and components. At this time, some manufacturers have not refined their components well enough to ensure short channel performance that meets Category 6 requirements. However, systems such as the Berk-Tek/Ortronics NetClear solutions are tuned to meet the center TIA target connector values 1. Jacks, patch panel and patch cord terminations, along with the performance of the horizontal cabling are tuned to this center target to provide maximum performance. Equipment Field Test Unit 1 Manufacturer: Fluke DSP-4100 and DSP-4100SR Adapter: DSP-LIA013 Software: Standards version 4.9 Software version 4.8 1 Cabling System Selection, A Product and System Approach, R. Aekins and G. Lafontaine 132 White Oak Road New Holland, PA 17557 Phone: 717-354- Fax717-354-7933

Field Test Unit 2 Manufacturer: Microtest OMNIScanner and OMNIRemote Adapter: CHAN 5/5e/6 Software: V06.00 Test Setup Field Tester Main Unit 1 Meter Patch Cord Field Tester Remote Unit Jack Patch Panel 5 Meters Horizontal Cable Test Results Components from five connector manufacturers and five cable manufacturers were assembled into seven meter channels as shown in the Test Setup section of this report. To maintain the anonymity of the manufacturers they are numbered one through five. Connector manufacturers are mated with cable manufacturers per commercial marketing relationships. Results for NEXT and PSNEXT testing are shown in Table 1. The values represent the worst-case margin across the test frequency range of 1 Mhz to 2 Mhz. Channel tests are evaluated against the requirements of ANSI/TIA/EIA-568-B.2-1-02. Table 1: Results of Short Link Testing Using Field Testers Horizontal Tester 1 Tester 2 Test Connector Cable Pass/Fail NEXT PSNEXT NEXT PSNEXT Number Manufacturer Manufacturer (db) (db) (db) (db) Test A Connector 1 Cable 1 Fail -0.9 0.5-1.7-0.9 Test B Connector 2 Cable 3 Pass 5.7 7.4 5 5 Test C Connector 2 Cable 5 Pass 1.9 3.5 1.1 1.5 Test D Connector 3 Cable 5 Pass 4.3 5.4 1.3 2.7 Test E Connector 4 Cable 2 Fail -1-1 -2.2 1.4 Test F Connector 5 Cable 4 Fail -0.7 1.4 1.9 1.9 Berk-Tek/Ortronics NetClear GT2 Pass 7.4 9 5.6 4.9 Results from two field testers are represented in the data. Both Test A and Test E failed NEXT using both field test units. Using tester 1, three of the six competitive tests failed Category 6 NEXT requirements while one test failed PSNEXT. One PSNEXT test was marginal passing by only 0.5 db. Page 2 of 5

Results for Tester 2 show that two of the six competitive samples failed NEXT requirements while one sample failed Category 6 PSNEXT requirements. Test E failed PSNEXT with Tester 1 while Test A failed PSNEXT with Tester 2. Of the competitive samples tested, Test B passed with the largest margin. The Berk-Tek/Ortronics NetClear GT2 sample exhibited the highest margin of any channel tested. There is a difference between the values measured by Tester 1 and Tester 2. Chart 1 through 4 contains swept frequency NEXT and PSNEXT data for Tester 1 and Tester 2. Evaluating the traces reveals that there is some offset between the data from Tester 1 and Tester 2. Results for Tester 2 show lower margins on average than Tester 1. This is most evident at frequencies below 1 MHz. This occurs for both NEXT and PSNEXT tests. Although this data is representative of what would be measured in an actual installation, the limited number of tests does not allow any definite observations to be made concerning measurement differences between handheld testers. Chart 1: Field Tester 1 Worst Case Near-End Crosstalk 0 100 1 0 2 Chart 2: Field Tester 1 Worst Case Power Sum Near- End Crosstalk 0 100 1 0 2 Power Sum Chart 3: Field Tester 2 Worst Case Near-End Crosstalk Chart 4: Field Tester 2 Worst Case Power Sum Near- End Crosstalk 0 100 1 0 2 0 100 1 0 2 Page 3 of 5

Conclusion Short link resonance was a problem that was commonly experienced with Category 5 cabling systems. This problem was solved through improvements in connecting hardware and specifying the minimum distance between connectors in a channel. Although Category 6 cabling system designers are aware of this phenomenon, it is again a problem for some manufactures. Several of the competitive solutions failed NEXT requirements. The data shows the importance of benchmarking short links in addition to the more common 100-meter links that many manufacturers consider worst case. In a study performed by Ortronics 2, it is observed that NEXT margin, when compared to margin measured on a network analyzer, decreases with channel length. Margin decreases steadily when the channels are below 15 meters; degrade more steeply below 10 meters and drastically below 7 meters. The Berk-Tek/Ortronics NetClear GT2 solution had the highest margin of any of the solutions tested. As seen in the results of this testing, there are also differences between the test results obtained from different field testers. Although the test sample size is small, there is a visible offset between the results. More work is required to investigate the causes of the differences between the field testers and their correlation to laboratory network analyzers. Manufacturers guarantees and warranties vary. It is important to specify a solution that offers strong 100-meter margins and guarantees compliance to Category 6 channel requirements at any length. The very high margins measured for the NetClear solution shows that the NetClear GT2 solution has the margin necessary to support any standard channel length, even those less than 15 meters. 2 Short Links and Channels, R. Aekins and G. Lafontaine Page 4 of 5

Data Communications Competence Center Nexans Data Communications Competence Center, located at the Berk- Tek Headquarters in New Holland, Pennsylvania, focuses on advanced product design, applications and materials development for networking and data communication cabling solutions. The Advanced Design and Applications team uses state-of-the-art, proprietary testing and modeling tools to translate emerging network requirements into new cabling solutions. The Advanced Materials Development and Advanced Manufacturing Processes teams utilize sophisticated analytical capabilities that facilitate the design of superior materials and processes. The Standardization and Technology group analyzes leading edge and emerging technologies and coordinates data communication standardization efforts to continuously refine Nexans Technology Roadmap. An international team of experts in the fields of cable, connectors, materials, networking, standards, communications and testing supports the competence center. The competence center laboratories are a part of an extensive global R&D network that includes eight competence centers, four application centers and two research centers dedicated to advanced technologies and materials research. Page 5 of 5