RSCC. Load cells. Special features. Data sheet

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

DMP 331i / DMP 333i LMP 331 i

Inductive sensor BI1.5-EG08K-Y1

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Inductive sensor NI10-M18-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Installation instructions Cable transit device Roxtec RS ES Ex

PROPORTIONAL VALVES Sentronic plus

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Pendant Light Fitting IEC Series 6470/2

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Installation instructions Roxtec RS ES Ex

Eddy Current Probe System

Pressure transmitter For applications in hazardous areas Model IS-3

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

TFRN Industrial RTD temperature sensor. CombiTemp TM

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

3 Cleaning. 4 Technical data

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Quality products from a single source

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Operating instructions

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

TFRN Industrial RTD temperature sensor. CombiTemp TM

Bimetal Temperature Switch

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Single Point Flow Monitor SW118 SW119

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Panel-mounting thermostats, type series EM

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Filters for Power Lines (Low Leakage Current)

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Speed sensor MiniCoder GEL 2471

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Panel-mounting Thermostats EM Series

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

PMG. Vibration Energy Harvesters

Selection matrix for electronic pressure switches

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

Pressure transmitter COMPACT IO-Link,

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Quality products from a single source


W100L: Laser Sensor in Mini- Format

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

W 9-2: A Versatile, Complete and Compact Series

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Photoelectric Sensors E3F2

Surface-mounting thermostats ATH series

Meteor Product Catalogue

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Process transmitter RMA422

Online data sheet GM32 IN-SITU GAS ANALYZERS

7 Lighting Technology

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

cdaq-itc Data Sheet cdaq Isolated Thermocouple Module Special Features Block Diagram B en

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

KEL 183 Cable entry frames

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Cable installation guidelines

Pendant Light Fittings Series 6050

Transcription:

RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test report per OIL R60 for class III scales - eets EC requirements as per EN 45 501 - Six wire circuit - Ex protection version (optional) Data sheet Diagram of RSCC load cell Load application (metric thread) Connection cable Load transfer (metric thread) Design: 50 kg to 200 kg Design: 500 kg to 5 t

Dimensions (in mm; 1 mm = 0.03937 inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D 24 C B 13 20 Without adapter for cable protection system 12x1.5 With adapter for cable protection system aximum capacity B C D 50 kg 62 50.8 25.4 31 8 100 kg 62 50.8 25.4 31 8 200 kg 87.3 57.2 28.6 43.7 12 HB 2

Dimensions (in mm; 1 mm = 0.03937 inches) Cable: Length 7.6 m Outside diameter 5 mm aterial PVC D E C B 13 20 12x1.5 Without adapter for cable protection system With adapter for cable protection system aximum capacity B C D E 500 kg 87.3 57.2 28.6 43.7 31 12 1 t 87.3 57.2 28.6 43.7 31 12 2 t 100 69.8 34.9 50 31 24x2 5 t 100 76.2 38.1 50 36.5 24x2 Cable protection (Option 6 required: with adapter for a cable protection system; customer side cable protection version) Cable protection system*, (provided by customer) comprising: Screwed cable gland* Flexible cable protection tubing* O ring (provided by customer) Unscrew the 12 sleeve and replace with an 12 threaded tube coupling * Supplier such as Flexicon (http://www.flexicon.uk.com) 3 HB

ounting accessories (to be ordered separately) Dimensions (in mm; 1 mm = 0.03937 inches) Center bearing collar W H D Rigid force transfer G B B F X a.f. H max /H min Emin/Emax aterial: Tempered steel, galvanized roller bearing steel PTFE/bronze corrugated foil ounting accessories just for static and quasistatic applications B aximum capacity Weight (kg) B H7 D F G H W X a.f. 50 kg to 100 kg 0.05 15 8 24 32 44 9 8 12 6.5 13 200 kg to 1 t 0.1 33.5 12 32 54.5 70.5 12 12 16 7 19 2 t to 5 t 0.4 57.5 25 60 94.5 124.5 22 24x2 31 10 36 aximum capacity H min H max E min E max B (N m) 50 kg 110 118 4 8 15 100 kg 110 118 4 8 15 200 kg 156 174 11 20 50 500 kg 158 174 11 19 50 1 t 158 174 11 19 50 2 t 231 263 13 29 200 5 t 241 265 12 24 500 HB 4

Specifications Type RSCC ccuracy class as per OIL R 60 Number of load cell verification intervals (n LC ) C3 3000 aximum capacity (E max ) 50 kg 100 kg 200 kg 500 kg 1 t 2 t 5 t inimum load cell verification interval % of E max 0.0120 (v min ) Nominal (rated) sensitivity (C N ) mv/v 2 Sensitivity tolerance % 0.25 Zero signal mv/v 0 0.1 Temperature coefficient of sensitivity (TK C ) 1) % of C n / 10 K Temperature coefficient of zero signal (TK 0 ) 0.0170 (20 C to 40 C) 0.0110 (-10 C to 20 C) Relative reversibility error (d hy ) 1) % of C n Non linearity (d lin ) 1) Creep upon loading (d cr ) over 30 min. Input resistance (R LC ) (nominal) Output resistance (R 0 ) Ω 389 15 350 1.5 Insulation resistance (R iso ) GΩ/100 V > 2 Reference excitation voltage (U ref ) 5 V Nominal (rated) supply voltage range (B U ) 0.5 to 12 Nominal (rated) amb. temperature range -10 to +40 (B T ) Operating temperature range (B tu ) C -30 to +70 Storage temperature range (B tl ) -50 to +85 Reference temperature (t ref ) 22 Limit load (E L ) 150 Breaking load (E d ) 200 300 200 % of E max Relative perm. vibrational stress (F srel ) 70 (oscillation width as per DIN 50100) Nominal (rated) displacement at maximum capacity (s nom ), 0.05 mm mm 0.35 0.4 0.35 0.1 0.2 0.2 0.4 Weight (G), approx. kg 0.7 1 1.4 1.7 2.2 Degree of protection per EN 60 529 IP 68 (test conditions 1 m water column / 100 h) (IEC 529) Cable length, six wire configuration 7.6 m as standard aterial: easuring body Cable entry Cable sheath stainless steel 2) stainless steel / neoprene PVC 1) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TK C ) are recommended values. The sum of these values is within the cumulated error limits according to OIL R60. 2) s per EN 10088-1. Cable assignment (6 wire configuration) With this cable assignment, the output voltage at the measuring amplifier is positive in the tensile direction when the transducer is loaded. (gray) (black) (white) (blue) (green) (red) (-) Sensing element (-) Excitation (-) Signal (+) Excitation (+) Sensing element (+) Signal (-) Shielding/drain wire, connected to enclosure ground 5 HB

Product numbers (overview) RSCC load cells aximum capacity Order no. aximum capacity Order no. 50 kg 1-RSCC3/50KG-1 1 t 1-RSCC3/1T-1 100 kg 1-RSCC3/100KG-1 2 t 1-RSCC3/2T-1 200 kg 1-RSCC3/200KG-1 5 t 1-RSCC3/5T-1 500 kg 1-RSCC3/500KG-1 RSCC load cells, optional versions Order No. K RSCC N Option 1: Design Standard C3 Option 2: ccuracy class C3 (OIL) Option 3: aximum capacity 50 50 kg 100 100 kg 200 200 kg 500 500 kg 1000 1 t 2000 2 t 5000 5 t N I1/21 I2/21 Option 4: Explosion protection No TEX IECEx+TEX Zone 1/21 + F, intrinsic safe II2G Ex ia IIC T6/T4 Gb / II2G Ex ia IIIC T125 C Db IECEx+TEX Zone 2/21, not intrinsic safe II3G Ex n IIC T6/T4 Gc / II2D Ex tb IIIC T125 C Db Option 5: Cable length S Standard (7.6 m) 12 12 m 20 20 m N Option 6: dapter for cable protection system No With adapter for cable protection system K-RSCC - N - C 3 - - - - RSCC accessories Rod end for RSC; 50 kg 100kg Rod end for RSC; 200 kg 1 t Rod end for RSC; 2 t 5 t 1-RSC/200KG/ZG 1-RSC/1T/ZG 1-RSC/5T/ZG Subject to modifications. ll product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure and predict with confidence HB 6 Hottinger Baldwin esstechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803 0 Fax +49 6151 803 9100 Email: info@hbm.com www.hbm.com