Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Similar documents
Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

about dktcomega DKTCOMEGA s mission

SECTION 4 TABLE OF CONTENTS

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

OPTICAL FIBERCONNECT. Version 3.

Light Source. Specification & User Manual

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

Connectix Cabling Systems

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Agilent 81600B Tunable Laser Source Family Technical Specifications August New model: nm, low SSE output!

3A+G Technology & Turnkey Production Solution XFS COMMUNICATIONS, INC.

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

LIIN-25 FO Pigtail FC (0.9mm)

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Keyed LC Connector Solution A LANscape Solutions Product

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC.

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

MTS/T-BERD Platforms WDMPMD Module

AXS-200/350 OPTICAL LOSS TEST SET. part of the SharpTESTER Line LAN Applications

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Lensed Fibers & Tapered Ends Description:

Agilent 81600B Tunable Laser Source Family

Introducing Ultra Short LC : Fiber Optic Cable Assemblies

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Fibre Optic Cable & Connector Guide

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

The World Of Professional Fiber Optics. safe flexible reliable

OPTICAL POWER METER WITH SMART DETECTOR HEAD

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

SC Connector. Fiber Optic Connectors. MDR Electronics

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Optical Perfection. HIGHYAG Beam Delivery Products

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

for FOSTEC INC. 1/ 15

2015 OPTICAL TRANSMITTERS

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

MAP Optical Power Meter Module (mopm-b1)

P-AD ADAPTORS. Features: Low insertion loss Low back reflection loss Easy to handle Environmentally stable

Fiber Optics Redefined

HI-DEX PRODUCT SET DATASHEET

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER

Singlemode Patch Cords and Pigtails

DIAMOND Fiber Optic Components

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

POLARIZED FIBER OPTIC SOURCE

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

MTS/T-BERD 8000 Platform

40G SWDM4 MSA Technical Specifications Optical Specifications

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

MXAN-LN series 1550 nm band Analog Intensity Modulators

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

SPECIFICATION. Optical Fiber Cable

3M 8900 Single-mode SC Crimplok Connector

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

RGB COMBINERS. 2.0 mm Narrow Key FC/PC or FC/APC Termination Excellent for Confocal. Ø900 µm Loose Hytrel Tube with the wavelength Laser Sources

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

3M No Polish Jacketed SC/APC Connector

Mar11 Rev E

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

PREMIUM 5e F/UTP PRODUCTS

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

ED5229GT-E Series. Page 1 of 8

FiberLink 3350 Series

MXAN-LN series 1550 nm band Analog Intensity Modulators

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

MPX / MPZ series. Low frequencies to 32 GHz Phase Modulators. Modulator. Features. Applications. MPX-LN series Performance Highlights

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

The need for Encircled Flux, real or imaginary?

MU Connector Series. Single Mode Small Form Factor Connector. qhigh quality, high precision Ø qinternational standard IEC FEATURES

FIBER OPTIC POSITRONIC INDUSTRIES. Interconnection Systems. RoHS Compliant Options Available! Catalog A-011 Rev.

PM Couplers (Polarization Maintaining Couplers)

25W 9xxnm Uncooled Multimode Laser Diode Module

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

MPS Webinar Technical Series

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

400G-FR4 Technical Specification

Optical Component Environmental Test System

1623A/B O-Band DWDM DFB Laser Module

FiberConnectorSeries LC

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Understanding Multimode Launching Conditions and TIA TSB-178

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

MPX and MPZ series Low frequencies to 40 GHz Phase Modulators

PONA 3000 Series Erbium Doped Fiber Amplifier

Enterprise Networks. Comms Room and Backbone. in DETAIL

LD Series High Performance Loose Tube Fiberoptic Cables

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

OPERATIONS GUIDE OWL

40G SWDM4 MSA Technical Specifications Optical Specifications

Transcription:

cable assemblies Assembly code page 46 Cable code page 47 Assembly classes page 48 Polarization maintaining assemblies page 52 45

Assembly: Ordering code Description cable type 27H01CD0- see cable code definition (see next page) fiber type 09- singlemode 9/125 µm LE- singlemode LEAF NZDS-fiber 50- multimode G50/125 µm 53- multimode G50/125 µm OM3 62- multimode G62.5/125 µm 20- multimode H200/230 µm connector type 20/ connector left side 20- connector right side total number of connectors 1-1 connector (pigtail) 4- e.g.: duplex patchcord with 4 simplex connectors length of assembly 2.5- length in meters (ferrule tip to ferrule tip) optical performance level 1st letter = connector left side 2nd letter = connector right side K no connector right side (pigtail) a a singlemode LAN-eco B B singlemode high-end C C singlemode 0.1 db d d singlemode high-end U E E singlemode high power F F singlemode 0.1 db U m m multimode E 2000 is manufactured under licence of DIAMOND SA, CH LOSONE Connector code type Performance level x= upon request A B C D E F M 00 no connector 10 FSMA 20 ST-HQ 22 ST-Security 24 ST-LEAN 30 FC 33 FC wide key 34 FC small key 40 LSA 43 LSA 45 MU 50 MT-RJ without pins 51 MT-RJ with pins 60 FiberGate x 65 FiberGate x Connector code type Performance level x= upon request A B C D E F M 70 SC x 73 SC 8 x 74 SC 9 x 77 SC duplex x 78 SC duplex x 80 LX.5 81 LX.5 duplex 83 LX.5 84 LX.5 duplex 85 LC x 86 LC x 88 LC duplex x 89 LC duplex x 90 LSH (E-2000 ) 93 LSH (E-2000 ) 97 LSH (E-2000 ) duplex 46

Cable code Definition for assemblies Description connector termination relevant diameter 09 0.9 mm for example, the following diameters are available: 0.6/ 0.9/ 1.7/ 1.8/ 1.9/ 2.0/ 2.1/ 2.4/ 2.6/ 2.7/ 3.0 mm cable jacket material a no outer jacket (e.g. 0.9 mm tube only) H LSFH T PVC y PE U PUR-FR Z X PUR other cable design 01 simplex, one fiber d8 duplex figure 8 (for LSFH and PVC only) d0 duplex figure 0?? number of fibers for multifiber cable with 2 fibers XX other secondary coating V V F F C CW d CH S SW T SH X other jacket / tube color a red B green C blue d orange E yellow F white G black H grey I brown K violet (blue-purple) L pink m turquoise T transparent U nature X other fiber coating color 0 not colored a red B green C blue d orange E yellow F white G black H grey I brown K violet (blue-purple) L pink m turquoise X other 47

Assembly Classes HUBER+SUHNER Cable Assemblies stand for PERFORMANCE and RELIABILITY Features available in 3 attenuation classes to meet different customer requirements full ceramic ferrules as a base for highest performance and reliability optimized products and assembling processes due to HUBER+SUHNER in-house connector and cable development and manufacturing outstanding mechanical and thermal strengths exceeding requirements of international standards 0.1 db Class Applications Compatibility Connector quantity long haul transmissions, saving costs for signal amplification low loss budget transmissions transmissions where uniform channel losses are required replacement of splices by keeping the same loss level all connectors are tuned fiber according to ITU-T G.652 premium ferrule with low eccentricity Attenuation each-to-each against ref. 0.02 0.04 0.06 0.08 0.1 0.12 db IL 1) IEC 61300-3-34 97% mean 0.15 db 0.06 db IEC 61300-3-4 max. 0.15 db RL IEC 61300-3-6 > 45 db > 50 db > 85 db U High-End Class Applications Compatibility Connector quantity CATV / Video Passive Optical Networks PON WDM /DWDM all connectors are tuned acc. to IEC 61755 fiber according to ITU-T G.652 Attenuation each-to-each against ref. IL 1) IEC 61300-3-34 97% mean 0.25 db 0.12 db IEC 61300-3-4 max. 0.35 db 0.06 0.10 0.12 0.22 0.30 db RL IEC 61300-3-6 > 45 db > 50 db > 85 db U Please note 1) at 1310 nm 0.1dB Assemblies have max. losses lower than today's measurement accuracy in the field. Measurement equipment (power meter/otdr) and measurement set-up, reference cables and adapters, environmental conditions and dirt easily cause measurement uncertainities of > 0.2 db. Reliable and reproducible measurements at accuracies below 0.1 db are feasible under laboratory conditions only. 48

Assembly Classes LAN-Eco Class Applications Compatibility Connector quantity universal premises cabling according to EN 50173-1, EIA/TIA 568 cost effective connections in PON FTTD, FTTH, FTTB, FTTX connectors are not tuned fiber according to ITU-T G.652 Attenuation each-to-each against ref. 0.03 0.1 0.18 0.25 0.36 0.5 db IL 1) IEC 61300-3-34 97% mean 0.45 db 0.20 db IEC 61300-3-4 max. 0.35 db RL IEC 61300-3-6 > 45 db > 50 db > 85 db U 1) at 1310 nm 49

high power Assembly HighPower assemblies Applications Compatibility Connector quantity 0.02 0.04 0.06 0.08 0.1 0.12 db DWDM / CWDM Raman, EDFA amplifications long haul transmissions saving costs for signal amplification Attenuation each-to-each IL 1) IEC 61300-3-34 97% mean RL IEC 61300-3-6 > 50 db > 85 db 0.15 db 0.06 db all connectors are tuned fiber according to ITU-T G.652 premium ferrule with low eccentricity against ref. IEC 61300-3-4 max. 0.15 db U 1) at 1310 nm The HighPower concept HighPower Assemblies are HUBER+SUHNER s answer to the ever-increasing transmission requirements of high-performance networks. Amplifiers used in DWDM applications can easily reach power levels of one Watt (30dBm). The optical power is concentrated on the fiber core of 10 µm diameter which corresponds to power densities larger than 1.3MW/cm 2. Slightest impurities or defects on the fiber end-face can thermally destroy the ferrule. The HighPower manufacturing process is characterized by stringent cleanness, premium polishing procedures, and special cleaning before packing. HUBER+SUHNER s HighPower assemblies guarantee maximal operational safety with their proven long term performance at average power levels up to 2 W and power peaks up to 5 W. List of hazard levels (IEC 60825-2) at different power levels in singlemode fibers at 1310 nm wavelength Level Optical power Hazard 1 15.6 mw 12 dbm safe under all foreseeable conditions 1M 42.8 mw 16 dbm safe, but might be hazardous if magnifying instrument is used 3R 80.0 mw 19 dbm low risk to eyes and skin 3B 500 mw 27 dbm medium risk to eyes and low risk to skin 4 > 500 mw high risk to eyes and skin, even for stray reflected light beams The high-performance LSH (E-2000 ) and LX.5 connectors meet the most stringent handling and functional safety standards. The full metal protection cap guarantees maximum eye safety and no environmental laser hazard under unplugged and plugged conditions. The special locking and mechanical coding system avoids unintended or unauthorised plugging. E-2000 HighPower LX.5 HighPower Upon request SC, LC and FiberGate HighPower assemblies can be supplied. However these three connectors do not offer eye and laser safety as they have no shutter. E-2000 is manufactured under licence of DIAMOND SA, CH LOSONE 50

Assembly Classes Full-ceramic ferrule HUBER+SUHNER connectors feature full ceramic ferrules! Only high-precision full ceramic ferrules with tightest dimensional tolerances can ensure best possible optical performances as well as reliability stability (chemical, thermal, mechanical) reproducibilty compatibility Endface geometry Tight endface geometry tolerances guarantees the customer a reliable and reproducible quality and long term behaviour. Interferometric ferrule endface inspection is mandatory for controlled and mastered manufacturing processes. Upon request a Quality Control Report can be issued for each assembled connector. (Illustration offered by Data-Pixel, France) Parameters: ferrule end face geometry 1) fiber height apex offset < 50 µm radius 50 nm to +100 nm 30 nm to + 100 nm ±100 nm 5-25 mm 5-12 mm SFF 1) acc. to IEC 61755-3-1/2 Assembly length tolerances up to [m] 0.5 1 2 5 10 20 > 20 tolerance 0 cm / + 4 cm 6 cm 10 cm 20 cm 30 cm 40 cm 2 % 51

polarisation-maintaining assemblies Application HUBER+SUHNER high-speed optical links can be used in a range of applications including: sensors fiber optic gyroscopes (FOG) interferometry fiber lasers linking in-line optical components such as lasers, modulators and amplifiers Raman Gain Amplifier optical links, a key component in ultra-long-haul and 40 Gbps systems PM passive components such as splitters and couplers PM compensators connector key slow axis input polarisation fast axis PM fibers PM fibers are designed to maintain the state of polarisation of light as it travels through the fiber. To achieve this maintenance of the state of polarisation, birefringence is induced into the fiber during the fabrication drawing process, and takes the form of a pre-defined stress structure within the core and cladding. Fiber birefringence defines two principal optical axes, the slow and fast axes, representing the differing propagational constants and subsequent optical transmission speeds. Specifications insertion loss typ. 0.2 db 0.2 db return loss > 45 db > 85 db extinction ratio > 23 db > 23 db operating temperature, depending on fiber and cable type 40 C to +85 C 40 C to +85 C mating cycles 1000 min. 1000 min. 52

polarisation-maintaining assemblies The PM connector family E-2000 PM SC PM FC PM Ordering information Description cable type 04A01VX0- bare fiber 09A01DT0-0.9 mm tube, orange 21H01DD0-2.1 mm LSFH cable, orange 30H01DD0-3.0 mm LSFH cable, orange fiber type P1- PM 1550 with UV/UV 400 µm (standard) connector type 1 st side/2 nd side 30/ FC 34/ FC 8 70/ SC 73/ SC 8 90/ E-2000 (LSH) 93/ E-2000 (LSH) 8 total number of connectors 2- terminated on both ends length of assembly 1-1 meter ER performance 23 extinction ratio 23 db (standard) 09A01DT0- P1-30/30 2 1 23 example E 2000 is manufactured under licence of DIAMOND SA, CH LOSONE 53