3M Locator Plate N

Similar documents
Instruction Guide February 2017

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Distribution Box (DDB)

3M Cold Shrink Foldback Splice Jacket Kit

Solutions for Electronic Specialty Markets (ESM)

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3 SLiC Aerial Closure with Rubber End Seal

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

18mm ECAM Cable Entry Port

3M Slim Lock Closures

SLiC Fiber Aerial Closure 533 and 733

SLiC Fiber Aerial Closure System

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

Cabinet Tools and Accessories Ordering Guide

Instructions. Cable with Armor F CAUTION. October Rev A

3M No Polish Jacketed SC/APC Connector

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

3M Better Buried Closures

3M MetPak 2-FB Header

3M 8900 Single-mode SC Crimplok Connector

4320 SS-25 Self-Strip Terminating Block

3M Better Buried Compound Compression Closure System

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

Scotch Heavy Duty Vinyl Electrical Tape 22

3M We are Projectors! When the show must go on, 3M makes it easy:

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M No Polish Jacketed SC/APC Connector

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

27mm ECAM Double Cable Entry Port

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Fiber Optic Closure System LL

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M Mini D Ribbon (MDR) Cable Assembly

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

3M Cold Shrink Splice Kit QS-III 5515A

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Closures BPEO

3M New Construction Cross-Connect Cabinets. The. Commitment. Your Copper Requires

3M Super 23 Electrical Tape

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink Splice Kit QS-III 5416A

Scotchlok Connectors and Tools

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

Built tough for long-term connections

Built tough for long-term connections

3M Pressurized Closure System 2-Type 505

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M High-Speed Solutions

3M Cold Shrink Rubber Splicing Kit 5552

Cold Shrink Silicone Rubber Termination QT-II

K & B Flame Retardant Building Riser Closures

Instructions for Use of Overlap Seam Repair Kit:

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

Dynatel Advanced Cable Locator 2250

ADF Module. Installation Guide. 1.1 Overview

HSK Mine and Portable Cable Splice

3M One Pass Mini Fiber Pathway

Installation Instructions

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Move & Store Cart CONTENTS. Assembly Instructions

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Installation instructions Roxtec RM ES systems

Better dispensing, better results.

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

3M ScotchCode Wire Marking and Identification System. Identify with 3M

Installation instructions Roxtec RM PE B

Installation instructions Roxtec RM BG B systems

Installation instructions Roxtec RM PE

Quick Release Roof-Mount Kit MB700

Garmin GC 10 Marine Camera Instructions

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

Installation instructions Roxtec RM ES B

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Installation instructions Roxtec RM ES

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

Installation instructions Roxtec RM BG systems

Electrical Markets 3M ScotchCode Wire Marking and Identification System. Quality. Marking. For Most Projects

Medium Box for Cable Termination

Desk Mount Articulating Dual Monitor Arm with Cable Management & Height Adjust

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Transcription:

M Locator Plate 44-107N Instructions for the assembly of.100 x.100 preassembled socket connectors 1.0 General The M Locator Plate 44-107N is designed to aid in the assembly of the preassembled socket connector family for all positions. End-to-end as well as daisy chain length (min daisy chain length ± 45 mm). Set-up and assembly instructions are based on termination procedures with M manual and pneumatic presses. Locator plate includes: Instruction sheet mounting screws 1 M571x26 Hex Key 1 SW 2.5 56x18 Hex Key 767-0005 (Optional) Figure 1 November 2012 78-9101-4048-8-B

2.0 Tool Preparation 2.1 Mount lever 1 on the guiding wing 2 and secure by locking screw. Make sure that the plastic ball is facing towards the operator (see Figure 2). 2.2 Remove the platen from the assembly press. Adjust shut height to 17 for the M Assembly Press 640, or to 17½ for presses the M Assembly Presses 5 and 16 using shut height gauge 46-1B. The the M Assembly Press 80 shut height is self-adjusting. 2. Place the locator plate on the press and fasten it with the two locking screws, that are included. Note: If the optional M Staging Platform (part number 767-0005) is used, please refer to its own instruction sheet for mounting. 8 7 4 9 6 2 1 10.0 Assembly Procedure.1 Cut cable to the required length. Figure 2.2 Loosen the left cable guide screw 4. Lift the guiding wing 2 and slide the left cable guide 4 into the required position depending on the connector size to be used. Connector pole sizes are indicated on the guiding wing 2. Lower the guiding wing 2 and make sure that the serrations of the base plate 5 and cable guide 4 are fully aligned. Tighten the cable guide locking screw.. Insert the appropriate cable 10 under guiding wing 2 and adjust the right cable guide 6. Make sure that the base plate 5 and cable guide 6 serrations are aligned and that the right cable guide 6 is as close as possible to the cable 10..4 Adjust the cable stop as required (see Figure 1). For daisy chain assemblies: left position 8. For end-to-end assemblies: right position 9..5 Install the proper platen (442-9) onto the press..6 Remove the connector from the packing strip cover down, IDCs facing down towards the plate. 5 2

.7 Slide the connector into the guiding groove against the connector locator stop 7..8 Place the cable 10 into the base plate serrations. For end-to-end assemblies, smoothly slide the cable between cable guides 4 6, under the guiding wing 2 against cable stop 9. For daisy chain assemblies, until the required length is obtained. The cable will fit between the cover and the contacts of the connector. Note: If the cable is not entering into the connector smoothly, check the flatness of the cable used..9 Complete the assembly by closing the press handle. Note: Never operate a pneumatic press without ensuring that there is a connector in the locator plate..10 Raise the press handle and remove the finished assembly by lifting the guiding wing 2 with the lever 1..11 Visually inspect to ensure that: a) The cover is fully locked. If not, check the shut height gauge. b) The cable is correctly aligned in the cover. If not, check the cable guide adjustment.

M is a trademark of M Company. Important Notice All statements, technical information, and recommendations related to M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 90 days from the time of purchase. M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at M s option, to replace or repair the M product or refund the purchase price of the M product. Except where prohibited by law, M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this M product, regardless of the legal theory asserted. Electronic Solutions Division Interconnect Products 6801 River Place Blvd. Austin, TX 78726-9000 800-225-57 www.mconnectors.com Please recycle. Printed in USA. M 2012 78-9101-4048-8-B

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: M: 44-107N