USER MANUAL GOLDMUND METIS 7 Integrated Amplifier
Congratulations. Thank you for purchasing the Goldmund METIS 7. You have acquired the best multi-usage ever made for professional and domestic uses. Please take some time to read this manual. It will provide you with useful information to make your pleasure of listening to the METIS 7 even higher. INTRODUCTION GOLDMUND METIS 7 Integrated Amplifier Goldmund was founded in 1978 and has ever since been dedicated to the accurate reproduction of sound and image. At Goldmund, we strive to lead in the creation, development and manufacture of the industry s most advanced technologies, including audio and video systems. The guiding principle at Goldmund is to produce a precise sound with the least possible loss of quality through the different stages. Goldmund will never adopt a technology before it is sufficiently developed to satisfy the high quality standards we set. This is why Goldmund has often rejected mainstream technologies and developed its own. GOLDMUND METIS 7 Integrated Amplifier - 1
Table of Contents 1 SETTING UP THE METIS 7 4 1.1 PRELIMINARIES 4 1.2 UNPACKING 4 1.3 CHOICE OF THE METIS 7 LOCATION 5 1.4 POWER SUPPLY 5 1.5 FIRST INSTALLATION & CONNECTIONS 6 2 OPERATING THE METIS 7 7 2.1FRONT PANEL FUNCTIONS 7 2.2 REMOTE CONTROL 7 3 MAINTENANCE 8 4 TECHNICAL SPECIFICATIONS 8 GOLDMUND METIS 7 Integrated Amplifier - 2
W A R N I N G This high quality integrated amplifier possesses new technical features which are necessary for today s best audio signals. Only careful use can provide all the satisfaction you are expecting. All handling must be performed according to the following instructions to avoid impairing the unit s performance. Nevertheless, in the Metis 7, Goldmund engineering excellence delivers extreme performance in a simple and convenient format that we hope you will enjoy for many years to come. IMPORTANT PLEASE DO NOT CONNECT ANY CABLES OR MOVE ANY PARTS BEFORE READING THE FOLLOWING INSTRUCTIONS. GOLDMUND METIS 7 Integrated Amplifier - 3
1 SETTING UP THE METIS 7 1.1 PRELIMINARIES Please read the following instructions very carefully. This high-precision unit will provide the best signal possible to your speaker, thanks to its unique technology. For exacting technicians, musicians, and all high-fidelity music purists who demand the very best in musical reproduction, we strongly recommend the use of top quality source such as the Eidos 17 Universal Player. The connection between the analog and digital sources and the Metis 7 as well as between the Metis 7 and the speaker are critical. Ultra low reflection interconnect cables are absolutely mandatory in analog and precise impedance SPDIF cables in digital to keep the time integrity that the Metis 7 is designed to provide. In all typical cases Goldmund recommends using the special Goldmund Lineal interconnect and digital cables. 1.2 UNPACKING WARNING If you need to return the Metis 7 to the factory or to your local representative for a warranty repair; please note that it must be repacked in the original packaging. This packaging has been designed specifically to protect your Metis 7 in transit. Use of alternative packaging is likely to result in damage, invalidating warranty cover. You will find in the packaging: - The integrated amplifier itself - The power cord - The remote control - This manual Unpack the above-mentioned parts carefully, keep all packaging for future use. GOLDMUND METIS 7 Integrated Amplifier - 4
1 SETTING UP THE METIS 7 (Ctd.) 1.3 CHOICE OF THE METIS 7 LOCATION Select a very rigid support, as required for your player transport. Use coaxial links of highest quality such as the Goldmund lineal in order to maintain the time accuracy and are highly recommended, especially for long distances. If you want to achieve the best possible sonic result, select an opposition on a shelf or on a piece of furniture where the Metis 7 is isolated from vibrations of mechanical components, including the player transport itself. 1.4 POWER SUPPLY The Goldmund Metis 7 uses an internal power supply developed by Goldmund to provide totally separate voltage between the USB part and the digital/analog circuitry. Your unit has been set to operate with the mains voltage of your area. Check on the power supply voltage switch on the rear panel if there is any doubt. If you move after purchasing the Metis 7 to an area using a different AC mains voltage, you can change the voltage yourself or consult your local Goldmund dealer for assistance in doing so. The voltage selector on the rear panel allows choosing between 220V (234V nominal) and 110V (117V nominal). In case the nominal line voltage in your country is out of range, please consult your local Goldmund dealer for assistance. The power supply unit can operate indifferently with both 50 and 60 Hz AC line. GOLDMUND METIS 7 Integrated Amplifier - 5
1 SETTING UP THE METIS 7 (Ctd.) 1.5 FIRST INSTALLATION & CONNECTIONS Connect the power cord to the back of the integrated amplifier and plug it into the nearest wall plug. For safety reasons, use only a 3 lugs grounded plug. To get the best sound from the Metis 7, avoid any multi-way plugs or extension cords. NOTE A USB driver needs to be installed on your computer before to use it as a source with your unit. Mac and Linux operating system do not need driver to be used with the Metis 7. Connect a computer, CD/DVD or Blu-ray player to the back panel of the Metis 7, using either the USB Audio, Toslink Optical, RCA Digital or RCA Analog connectors. When the input source is connected, connect your Metis 7 using the two speaker output connectors located on the rear plate of your unit. Select one of the 3 available inputs for listening using the front input switch. Only one connection per input can be used at once. The Optical Toslink input has the priority on the RCA Digital input, in case you want to use the Digital input, unplug the Optical cable from the digital input. AT T E N T I O N: A residual high frequency noise may remain audible in some circumstances if an analog input is left open and is selected. This disturbance has no effect on the amplifier but may be avoided easily through the application of short-circuit plugs on all unused inputs. GOLDMUND METIS 7 Integrated Amplifier - 6
2 OPERATING THE METIS 7 2.1 FRONT PANEL FUNCTIONS INPUT SOURCE SELECTION The back panel inputs are selected by selecting the 3-positions switch on the front panel. When the digital input has been selected, the orange led will be displayed on the front panel only when the digital source has been locked to the source frequency. In analog and USB input the orange led is always on. OUTPUT VOLUME ADJUSTMENT The level control may be adjusted manually with the front panel knob or by remote control. It acts for all channels simultaneously. 2.2 REMOTE CONTROL Your Metis 7 has built-in remote control for volume and mute. OUTPUT VOLUME ADJUSTMENT To adjust the global volume use the upper and lower arrow. The orange flashes quickly. MUTING The mute circuit is controlled using the remote. To mute or un-mute the Metis 7 with the remote, press the central key. The orange led flashes slowly. NOTE Place the + side of the remote s battery on the battery enclosure as shown on the picture. Use a CR2032, 3V battery GOLDMUND METIS 7 Integrated Amplifier - 7
3 MAINTENANCE To clean your Metis 7 use only a soft, clean, dry or slightly damp cloth. Avoid using domestic cleaning products. There are no user serviceable parts inside the Metis 7. Unauthorized servicing or alteration invalidates the manufacturer s warranty. All enquires relating to product servicing and operation should be referred to the local authorized retailer supplying and supporting your Goldmund equipment. WARNING Always turn the power off before cleaning your Metis 7. 4 TECHNICAL SPECIFICATIONS POWER SUPPLY Nominal line voltage: 117 or 234 V (switchable) Fuse 8A for 110V and 220V Input voltage range: +/- 10 % Rated Power Consumption: IEC 60065, 1/8 Output Power at 8 Ω: 240 W (per unit) Max Power Consumption: IEC 60065 at 8 Ω /1% THD: 700 W OUTPUT POWER FPP at 8 Ω: 190 W IEC 60065 at 8 Ω / 1 % THD+N: 2 x 175 W GOLDMUND METIS 7 Integrated Amplifier - 8
4 TECHNICAL SPECIFICATIONS (Ctd.) INPUTS USB device: - Audio Class 2.0 (no driver required on Mac OS X as of v.10.6.4 nor on Linux, driver required only for Windows) - Sample rate up to 384 khz/bit depth up to 32 - DSD over PCM capabilities 1 x Toslink Optical or Digital S/PDIF coaxial RCA 75 Ohms 1 x Analog RCA (Left & Right): ADC conversion for DSP correction FRONT PANEL CONTROLS Knob for digital volume control Input switch selection Power and lock Led REAR PANEL CONNECTORS AND CONTROLS 2 x output binding posts Left & Right ON/OFF power switch key Voltage input selector RS232 Command connector FREQUENCY RESPONSE 20 Hz - 20 khz, unloaded: +/- 0.5 db DISTORTION THD+N, unloaded: < 0.08 % from 20 Hz to 20 khz at 30 V RMS output IMD (SMPTE), unloaded: < 0.02 % before clipping OUTPUT NOISE FLOOR Inputs terminated with RCA Shorting Caps, unloaded: < 10 µv from 20 Hz to 20 khz GOLDMUND METIS 7 Integrated Amplifier - 9
4 TECHNICAL SPECIFICATIONS (Ctd.) DYNAMIC RANGE 22 khz measurement bandwidth (flat): > 100 db GAIN 35 db DAMPING FACTOR 220 at 1 khz, 8 Ω SIZE AND WEIGHT 44 W x 35.2 D x 10.6 H (cm) Weight: 10 kg WARRANTY 3 years, parts and labor. Information and product specifications contained in this manual are subject to change without prior notice. Updated versions of this manual will be posted on our website at www.goldmund.com. Please visit our support page at http://www.goldmund.com/support/register to register your Goldmund product for warranty. GOLDMUND METIS 7 Integrated Amplifier - 10 RevB