ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

Similar documents
Solid-State Digital Timer

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

SQM40/41 Actuators for air and gas dampers

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

SCALE & WEIGHT DISPLAYS

Warner Photoscanner MCS-500 Series LED Photoelectric Control

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Model Number Structure

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

ALLEN BRADLEY TIMING RELAY

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

3M Sensored Termination (15 kv) QX-T15I-vi1-E

OPERATING MANUAL. Cole-Parmer Stir-Pak. Mixer Head Model Numbers , , , , & Mixer Controller Model Numbers

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

Q3X Laser Contrast Sensor

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

SDC-500 Digital Optical Chopper Operating Instructions

WaterVue TV Installation & User Manual

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Multi-functional safety relay modules PROTECT SRB-E

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

NewScope-7A Operating Manual

Multifunction Digital Timer

Installation and Operation Manual. for the. SM-6 Programmable Stereo Mixer

45LM Series Modules. 45LM Series Description. Timing Logic Functions. LED Signal Strength Display Function. 45LM Series Modules Specifications

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

Automatic Transfer Switch Control PLC Operator s Manual

16 Amp Electronic 24 Hour/7 Day Time Controller

Pulse Counters, electromechanical

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Sprite TL Quick Start Guide

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Modular Lube Lubrication Systems System Controls

INSTRUCTION MANUAL. Made in the U.S.A. by USA Dance Floor. Copyright 2017 USA Dance Floor, LLC

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

Junior Max (JR Max ) Controller

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

WID-DL74 WID-DL74 BLP WID. Designed for. Installation guide for workitdesk interactive table for. BrightLink Pro

Q3X Laser Contrast Sensor

Flat-Bed Module Recorders

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

TV Lift System Model CL-65 Installation Instructions

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Absolute Encoders Multiturn

EA402 SERIES ANALOG INPUT FLOW RATEMETER/TOTALIZER INSTALLATION & OPERATING INSTRUCTIONS West Stetson Avenue Hemet, CA USA

COLORBOX - ILLUMINATED ASSESSMENT CABINETS VF0600, VF1200

K Service Source. Apple High-Res Monochrome Monitor

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

STD-525T PRECISION TIMER

MODEL HS35 DRAWWORKS OPTICAL ENCODER

5530M and 5530MHV Adaptatone Installation Sheet

Metal Electrode Meter

EXLUX ECOLUX 6480 Series

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

MARCO CORNER, 19/ THIENE (VI) ITALIA

10 PDUs 19 PDUs Zero-U PDUs

Time-Lag Relays. User s Handbook (General Model)

3M Distribution Box (DDB)

3M Locator Plate N

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Operating instructions Electronic preset counter Type series 717

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Absolute Rotary Encoder E6CP

Model /29S RF Splitter

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

READ ME FIRST. Touchstone TV Lift

Style 5S Clock / Timer

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Instruction Manual Model 5620 Power Controller

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Backlight Replacement

Q3X Laser Contrast Sensor

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Installation and Operation Manual

M1020 Programmable Limit Switch (PLS)

Global Water Instrumentation, Inc.


MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Part-Turn Electric Multi-Turn Electric

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Transcription:

ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://instserv.com 365B Long Ranger Timer INSTALLATION INSTRUCTION November, 2000 3-0365-095-04-00 DESCRIPTION: The 365B Timer is a microprocessor based digital timer with three rotary switches for setting and adjustment of the Preset. The Preset can be any three-digit value from.01 Sec to 999 Hrs. The Decimal and Range are switch selectable. There is a high-intensity blue vacuum fluorescent display which is DIP switch selectable to Timeup or Timedown. Two heavy duty 7A DPDT relays provide instantaneous, interval or delayed output control. Plug-in watertight panel mounting allows easy replacement without the removal of field wiring. 1.50 38.10 1.10 27.95 5.31 134.87 ATC 3 6 5 2.58 65.53 2.64 67.00 MOUNTING: 1. Cut out a 2 5/8" square mounting hole. 2. Mount timer to housing before mounting in the panel. Make sure the rubber gasket is flush with timer bezel before tightening the screws. 3. Slide housing with timer (as pictured above) through cut out until the gasket is against panel. Be sure there are no ripples in gasket and it is flat and flush to panel. 4. Holding the timer in place install the aluminum mounting bracket around the timer housing and slide it forward until the ends contact the rear of the panel. 5. Using the two screws provided, attach the bracket to the timer housing and tighten screws until the timer housing is fastened securely to the panel. 6. Install the mylar insulator over rear of bracket by sliding the end tabs between the bracket and the housing and allowing metal extensions on rear of bracket to go through the slots in insulator to hold it securely in place. 7. Important Note for Moist Environment: For maximum water-tightness, the two (2) front screws securing the timer in the housing should be torqued to 4 inch pounds.

THE DISPLAY: A high intensity blue vacuum fluorescent display consists of three digits and a decimal point. There is a horizontal timing bar " " which appears to the right of the display and blinks once per second during timing. This is very useful in showing that the timer is timing especially when the digits do not change rapidly as in the hours ranges. There is also a triangular timed out symbol " " which indicates when the delayed relay is energized at time-out. The timing bar blinks rapidly at time-out as well. TIME-OUT SYMBOL THREE DIGIT DISPLAY TIMING BAR TIME UNITS WINDOW THREE DIGIT PRESET DECIMAL POINT WINDOWS DIGIT SET KNOBS (REMOVABLE) CHANGING THE DISPLAY MODE OF OPERATION: (ARRANGEMENT 30 MODELS) Depending on the position of an internal DIP switch, the 365's three-digit display will show elapse time (TIMEUP) or time remaining (TIMEDOWN) from the set point. (ARRANGEMENT 50 MODELS) Depending on the position of an internal DIP switch, the 365's three-digit display will time up (TIMEUP & GO) to the set point, the delayed relay energizes and continue timing until reset. When (TIMEDOWN & GO) is selected, the display will time down from the set point, the delayed relay energizes, and timing continues timing up from zero giving a direct overshoot reading. Timing will continue until reset. (ARRANGEMENT 10 MODELS) These units do not have a DIP switch or digital display. The display is a blinking LED which blinks once per second during timing and blinks rapidly after time-out. ADJUSTING THE ROTARY SWITCHES: The time preset is set with the rotary switch knobs located below each digit. These knobs can be rotated in either direction (CW or CCW). The time preset can be adjusted during timer operation, this will result in an immediate change in the timing cycle. Setting all three digits to zero will cause an instant time-out of the timer.

CHANGING THE TIMING RANGES: Decimal Point Location can be changed with the white plastic lever arm mounted behind the front face of the timer. This lever arm moves into three positions (XXX, XX.X, XX.X). With finger force you can change the position and at the same time observe the front of the timer. This sets the decimal point electronically as well as mechanically. SEC-MIN-HRS can be changed by moving a small arm located in a slotted arc on the side plate of the timer. Depressing this arm slightly with a pencil or pen point allows selection of any one of three ranges. This sets the range electronically as well as graphically in the window on the front of the timer. OPERATION: As soon as power is applied to terminals 1 (L1) & 2 (L2) and a jumper from 1 to 15 (clock) of the timer. The instantaneous relay is energized and its contacts (8-6-7 & 9-14-10) change state. The timer starts timing, indicated by the display. When the preset value is reached, the display stops, the triangular timed out symbol lights, and the delayed relay energizes and its contacts (3-4-5 & 13-11-12) change state. The timer remains in this timed-out condition until reset by removing power from terminal 1 for at least 60 msec. At reset, both relays revert back to their shelf (without power) state. WIRING Instantaneous Contacts L1 L2 Delayed Contacts 8 6 7 9 14 10 1 2 15 3 4 5 13 11 12 L1 to Clock I 1 I 1 I 2 I 2 D 1 D 1 D 2 D 2 Start/Reset Run Power Supply Clock HOUSING TERMINALS: 14 13 12 11 10 9 8 7 1 2 3 4 5 6 15 16

SPECIFICATIONS: Models - choice of three standard 120VAC models: 365B300Q10PX timing LED only, without display 365B300Q30PX, with display, timeup or timedown. 365B300Q50PX, with display timeup & go or timedown & go. Each model available in 240VAC or 24VAC. Timing Ranges Nine (9) Switch-Selectable ranges 0-9.99, 0-99.9, and 0-999 Sec, Min, or Hrs. Housing 72mm 2 DIN size, Plug-in design, fully gasketed dust and water-tight when panel mounted. Panel mounting bracket included. Housing Terminals 16 Screw (6-32) terminals with saddle clamps accessible at rear. Load Relays Type: DPDT, Form C Contact Rating: 7 Amps @ 120VAC, or 1/6HP@120VAC Operate & Release Time: 10ms, max. Life: 10 million operations (no load) Power Requirements 120VAC, 50 or 60 Hz (10%, -20%) Running <100mA@120VAC 240VAC, 50 or 60 Hz (10%, -20%) Running <50mA @240VAC 24VAC, 50 or 60 Hz (10%, -20%) Running <300mA@24VAC Temperature Rating 32 F to 140 F (0 o to 60 C) Weight Net: 1lb. 6 oz. Shipping: 2 lbs. Reset Time Guaranteed not to reset <20ms. Guaranteed to always reset>40ms. Display Arrangement 10: Red LED, blinks once per second during cycle, rapidly after time-out. Arrangement 30 & 50: Cycle Progress 3-digit high-intensity blue VF display, 0.3 inch Timing Bar: " " display; blinks once per second during timing, rapidly after time-out. Timed-Out Symbol: "Ñ", lights after time-out.

ORDERING CODE 365B 300 Q 30 PX BASIC TYPE On-Delay Digital Timer RANGE 300.01 to 9.99, 99.9, 999 Sec, Min, Hrs 000 Special VOLTAGE & FREQUENCY Q 120 VAC, 50/60 Hz R 240 VAC, 50/60 Hz T 24 VAC, 50/60 Hz K Special ARRANGEMENT 10 Timing LED only, without Display 30 Selectable Timeup or Timedown w/display 50 Selectable Timeup & Go or Timedown & Go w/display FEATURES P S X K Basic Plug-in unit with housing Surface mounted Plug-in unit* Standard unit Special *Order with Surface Mounting Bracket, P/N 0353-260-27-00 as separate item. A WORD ABOUT SAFETY Most of ATC s products are designed for general for general and not for specific applications. Because of this, we usually are not aware of how they eventually will be used. However, they are frequently employed in controlling automatic machinery or processes. Although ATC makes product of high reliability, every product, given enough time, can be expected to fail. Statistically, devices can fail after a short period of time or a long period of time or anything in between. In essentially all cases, failure means (1) failure to provide a logic signal or power to an electrical load when it should or (2) the providing of such a signal or power when it should be absent. Less often, failure means failure to meet some other specification. But, in all cases, it means to do something unwanted or unexpected. No ATC product is fail-safe in and of itself. The photoelectric controls that we manufacture and/or market are for general industrial application and are not designed as a primary optical safety device and are not fail-safe in and of themselves. Since the failure of automatic machinery or processes can create hazardous conditions for personnel or property, whatever the definition of failure might be, it is necessary to consider the consequences of failure and design of the application in which the ATC product is used so that failure will not create a hazard to personnel or property. The design must insure that any failure will result in a fail-safe condition and there will be no danger to personnel and/or property involved in the use of the product. Designs incorporating controls of any kind should be carefully considered to provide for their eventual failure. IMPORTANT NOTICE Our recommendations, if any, for the use of this product are based on tests believed to be reliable. The greatest care is exercised in the selection of our raw materials and in our manufacturing operations. However, since the use of this product is beyondthe control of the manufacturer, no guarantee or warranty, express or implied is made as to such use or effects incidental to such use, handling or possession or the results to be obtained, whether in accordance with the directions or claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use. Warranties of Sale, disclaimer thereof and limitations of liability are covered exclusively by Automatic Timing and Controls printed warranty statement for the controls. These instructions do not expand, reduce, modify or alter Automatic Timing and Controls warranty statement and no warranty or remedy in favor of a customer or any other person arises out of these instructions. AUTOMATIC TIMING AND CONTROLS