The Cathode Ray Tube

Similar documents
CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

OSCILLOSCOPE AND DIGITAL MULTIMETER

CHAPTER 4 OSCILLOSCOPES

CATHODE-RAY OSCILLOSCOPE (CRO)

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

CATHODE RAY OSCILLOSCOPE (CRO)

Using an oscilloscope - The Hameg 203-6

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Elements of a Television System

Cathode Ray Oscilloscope

Experiment 9A: Magnetism/The Oscilloscope

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

THE OPERATION OF A CATHODE RAY TUBE

Tutorial Cathode Rays Year 12 Physics - Module 9.3 Motors and Generators

THE OPERATION OF A CATHODE RAY TUBE

University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

Computer Graphics Hardware

THE CATHODE -RAY OSCILLOSCOPE

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Presented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali. Supervised by: Dr.Mohamed Abd El Ghany

INSTRUMENT CATHODE-RAY TUBE

Teltron Delection Tube D

2.2. VIDEO DISPLAY DEVICES

THERMIONIC GUN CATHODE-GRID ASSEMBLY TEST PROCEDURE

INSTRUMENT CATHODE-RAY TUBE

Brown, A., Merkert, J., & Wilson, R. (2014). Build your own particle accelerator. Science in School, (30),

Types of CRT Display Devices. DVST-Direct View Storage Tube

B. TECH. VI SEM. I MID TERM EXAMINATION 2018

4.9 BEAM BLANKING AND PULSING OPTIONS


UNIT IV- STORAGE AND DISPLAY DEVICES

OPERATING INSTRUCTIONS FOR SYLVANIA. Type I08 Cathode-Ray Oscilloscope. Sylvania Electric Products Inc. Industrial Apparatus. Emporium, Pennsylvania

Activity P32: Variation of Light Intensity (Light Sensor)

These are used for producing a narrow and sharply focus beam of electrons.

Lecture 17 Microwave Tubes: Part I

PRACTICAL APPLICATIONS OF ELECTRONICS IN ANAESTHESIA. G. A. HAY Department of Medical Physics, University of Leeds

Beginners How to Test DSO138mini

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

3B SCIENTIFIC PHYSICS

An Efficient SOC approach to Design CRT controller on CPLD s

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Physics 123 Hints and Tips

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

R2001A/B/C Service Monitor Alignment Sections

decodes it along with the normal intensity signal, to determine how to modulate the three colour beams.

SERVICING TELEVISION VOLUME 2 G. N. PATCHETT LONDON: NORMAN PRICE (PUBLISHERS) LTD. The Cathode Ray Tube. Sawtooth Current Generators

BME 3512 Biomedical Laboratory Equipment List

NAPIER. University School of Engineering. Advanced Communication Systems Module: SE Television Broadcast Signal.

? Me ???????? ?????? & > Dec. 14, ??? 2,455,992 ???.. ????? T. T. GOLDSMITH, Jr., ET AL CATHODE-RAY TUBE AMUSEMENT DEVICE. Filed Jan, 25, 1947

Display Systems. Viewing Images Rochester Institute of Technology

PAST EXAM PAPER & MEMO N3 ABOUT THE QUESTION PAPERS:

Reading. Displays and framebuffers. Modern graphics systems. History. Required. Angel, section 1.2, chapter 2 through 2.5. Related

Monitor and Display Adapters UNIT 4

Pole Zero Correction using OBSPY and PSN Data

Agilent DSO5014A Oscilloscope Tutorial

A Review- on Different Types of Displays

3. Displays and framebuffers

J.J. Thomson, Cathode Rays and the Electron

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

ELECTRICAL ADJUSTMENT INSTRUCTIONS

User's Manual. Rev 1.0

A History of the Analog Cathode Ray Oscilloscope

INSTRUCTION MANUAL Model 2522C. 20 MHz DIGITAL STORAGE/ANALOG OSCILLOSCOPE

Test of ScannerMAX Saturn 1 with 600Hz Sine-wave input, having an optical scan angle of 40 optical degrees peak to peak.

The BAT WAVE ANALYZER project

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

Agilent Technologies 54522A

The Knowledge Bank at The Ohio State University. Ohio State Engineer

Displays. History. Cathode ray tubes (CRTs) Modern graphics systems. CSE 457, Autumn 2003 Graphics. » Whirlwind Computer - MIT, 1950

CMPE 466 COMPUTER GRAPHICS

Reading. 1. Displays and framebuffers. History. Modern graphics systems. Required

Analog Circuits Prof. Nagendra Krishnapura Department of Electrical Engineering Indian Institute of Technology, Madras. Module - 04 Lecture 12

Reading. Display Devices. Light Gathering. The human retina

Display Devices & its Interfacing

CS2401-COMPUTER GRAPHICS QUESTION BANK

RF Power Generation II

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

Computer Graphics : Unit - I

SC24 Magnetic Field Cancelling System

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

BUREAU OF ENERGY EFFICIENCY

SC24 Magnetic Field Cancelling System

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

ZONE PLATE SIGNALS 525 Lines Standard M/NTSC

Television brian egan isnm 2004

Experiment 9 Analog/Digital Conversion

Time Varying Signals Part A Chemistry 838

Part 1: Introduction to computer graphics 1. Describe Each of the following: a. Computer Graphics. b. Computer Graphics API. c. CG s can be used in

Computer Graphics: Overview of Graphics Systems

Brief Description of Circuit Functions. The brief ckt. description of V20 107E5 17 Monitor

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

3B SCIENTIFIC PHYSICS

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Comp 410/510. Computer Graphics Spring Introduction to Graphics Systems

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

All-Tube SRPP on Steroids. Only $ February Support the Tube CAD Journal. get an extremely powerful tubeamplifier

Transcription:

Lesson 2 The Cathode Ray Tube The Cathode Ray Oscilloscope Cathode Ray Oscilloscope Controls Uses of C.R.O. Electric Flux Electric Flux Through a Sphere Gauss s Law

The Cathode Ray Tube Example 7 on an accelerated electron (See lesson 1) describes a portion of a cathode ray tube (CRT). This tube, is commonly used to obtain a visual display of electronic information in oscilloscopes, radar systems, television receivers, and computer monitors. The CRT is a vacuum tube in which a beam of electrons is accelerated and deflected under the influence of electric or magnetic fields. The electron beam is produced by an assembly called an electron gun located in the neck of the tube. These electrons, if left undisturbed, travel in a straight-line path until they strike the front of the CRT, the screen, which is coated with a material that emits visible light when bombarded with electrons.

The Cathode Ray Tube

The Cathode Ray Tube

The Cathode Ray Tube The CRT is composed of two main parts, 1. Electron Gun 2. Deflection System Electron Gun Electron gun provides a sharply focused electron beam directed toward the fluorescent-coated screen. The thermally heated cathode emits electrons in many directions. The control grid provides an axial direction for the electron beam and controls the number and speed of electrons in the beam. The momentum of the electrons determines the intensity, or brightness, of the light emitted from the fluorescent coating due to the electron bombardment. Because electrons are negatively charged, a repulsion force is created by applying a negative voltage to the control grid, to adjust their number and speed.

The Cathode Ray Tube A more negative voltage results in less number of electrons in the beam and hence decreased brightness of the beam spot. Since the electron beam consists of many electrons, the beam tends to diverge. This is because the similar (negative) charges on the electrons repulse each other. To compensate for such repulsion forces, an adjustable electrostatic field is created between two cylindrical anodes, called the focusing anodes. The variable positive voltage on the second anode cylinder is therefore used to adjust the focus or sharpness of the bright spot. The Deflection System The deflection system consists of two pairs of parallel plates, referred to as the vertical and horizontal deflection plates. One of the plates in each set is permanently connected to the ground (zero volt), whereas the other plate of each set is connected to input signals or triggering signal of the CRO.

Cathode Ray Oscilloscope Display Time base Y-gain Channel1 Channel 2

Cathode Ray Oscilloscope A typical analogue oscilloscope

Cathode Ray Oscilloscope Controls Y-Gain amplifies the Y-deflection small input voltages are amplified by built-in amplifiers before applying to the Y-plates. Y- Gain = 0.5 V/div 0.5 volt will cause a vertical deflection of 1 division

Cathode Ray Oscilloscope Controls Time Base is a saw-tooth voltage applied internally across the X-plates. volts time

Cathode Ray Oscilloscope Controls Time Base controls the speed at which the spot sweeps across the screen horizontally from left to right. spot on right side of screen volts Fly back spot at centre of screen 0 time spot on left side of screen Time taken for spot to move across the screen and back

Cathode Ray Oscilloscope Controls Time Base spot on right side of screen volts Fly back spot at centre of screen spot on left side of screen 0 time Screen

Cathode Ray Oscilloscope Controls Time Base it helps to display the actual waveform of any a.c. applied across the Y-plates normally calibrated in s/cm ms/cm s/cm gives the time required for the spot to sweep 1 cm horizontally across the screen.

Cathode Ray Oscilloscope Controls Time Base: How It Works spot on right side of screen volts B Fly back spot at centre of screen 0 time spot on left side of screen A C Time taken for spot to move across the screen and back

Uses of C.R.O. 1. Display waveforms of alternating p. d. 2. Measure potential difference d.c. a.c. 3. Measurement of Frequency 4. Measurement of Phase

Uses of C.R.O. Displaying a Voltage Waveform Peak-to-Peak voltage Time Period (ms) To get the time period you need to measure this distance and convert it to time by multiplying by the time base setting

Uses of C.R.O. Displaying a Voltage Waveform

Uses of C.R.O. Displaying a Voltage Waveform Set the time-base to a suitable frequency, Apply the input to the Y-plate a steady waveform of the input will be displayed on the C.R.O.

Uses of C.R.O. Measuring a Direct Current Voltage switch off the time-base a spot will be seen on the C.R.O. screen d.c. to be measured is applied to the Y-plates spot will either deflected upwards or downwards deflection of the spot is proportional to the d.c. voltage applied

Set the VOLTS/DIV to 1 by adjusting the outer dial. Turn the inner dial all the way to the right, which will put it in the calibrated position. Switch the AC-GND-DC switch for channel 1 to DC. Uses of C.R.O. Measuring a Direct Current Voltage

Uses of C.R.O. Measuring a Voltage as a Voltmeter it has nearly infinite resistance (between the X- and Y-plates), therefore draws very little current; it can be used to measure both d.c. and a.c. voltages; and it has an immediate response.

Uses of C.R.O. Measurement of Frequency Time Per Division Dial The Time/Div dial on the oscilloscope controls the amount of time per centimeter division. A simple method of determining the frequency of a signal is to estimate its periodic time from the trace on the screen of a CRT. To calculate the frequency of the observed signal, one has to measure the period, i.e. the time taken for 1 complete cycle, using the calibrated sweep scale. The period could be calculated by T = ( no. of squares in cm) x ( selected Time/cm scale ) Once the period T is known, the frequency is given by f (Hz)= 1/T(sec)

Uses of C.R.O. Example: Measurement of Frequency and a. c. voltage Using a CRO 6.4 cm The total height of the wave from peak to trough is 6.4 cm V pk to pk = 12.8 V V 0 = 6.4 V 1 cycle occupies 2.8 cm T = 1.40 ms = 1.40 10-3 s Frequency = 1 1.40 10-3 s = 714 Hz 2.8 cm The time base controls are set at 5 ms/cm The voltage gain is set at 2 V/cm

Uses of C.R.O. Measurement of Phase The calibrated time scales can be used to calculate the phase shift between two sinusoidal signals of the same frequency. If a dual trace or beam CRO is available to display the two signals simultaneously ( one of the signals is used for synchronization), both of the signals will appear in proper time perspective and the amount of time difference between the waveforms can be measured. This, in turn can be utilized to calculate the phase angle, between the two signals. Phase shift in cm. One periodin cm. x 360

Measurement of Phase Uses of C.R.O. Phase shift in cm One period in cm Phase shift in cm. x 360 One periodin cm.

Lissajous Figures Uses of C.R.O. Lissajous figure can be displayed by applying two a.c. signals simultaneously to the X-plates and Y-plates of an oscilloscope. As the frequency, amplitude and phase difference are altered, different patterns are seen on the screen of the CRO. Lissajous figures are obtained with an oscilloscope when this is operated in XY mode and when in both channel 1 and 2 voltages are applied. If the ratio of the two frequencies of the voltages is just equal to a rational number, standing figures appear on the oscilloscope (Lissajous figures); if the frequency ratio, however, deviates slightly from a rational number, these figures are moving. In this way it is possible to make small frequency differences visible and measurable. Unknown frequencies can be determined, if these are applied to one channel of the oscilloscope and are superimposed with a voltage of known, but adjustable frequency from a function generator applied to the other channel.

Uses of C.R.O. Use of Lissajous Patterns to Calculate Phase Shift Lissajous patterns are obtained on the scope simultaneously by applying the two sinusoidal inputs to be compared at the vertical and horizontal channels. The phase shift is then determined using measured values taken from resulting Lissajous pattern. This pattern on the CRT screen may be either a straight line or a circle or an ellipse depending on the amount of phase shift.

Uses of C.R.O. Lissajous Figures Same amplitude but different frequencies