MAINS DISTRIBUTION GUIDE

Similar documents
Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

DISTRIBUTION RENTAL GUIDE

Custom Cabling for Entertainment, Film and TV

COMBINATION UNITS MARCH 2018

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

POWER DISTRIBUTORS CRANE AND TUNNEL DISTRIBUTION CABINETS. socket (DIN 49440) 250V Output terminals. approx. Type Ord.no. kva kg

Incremental Hollow Shaft Encoder

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

TeSys circuit-breakers

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Customized power distribution systems

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

King Fahd University of Petroleum and Minerals Electrical Engineering Department 1. Homework 5 - SOLUTION KEY

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

AS09..S 3-pole Contactors - Spring Terminals

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

Electromechanical Relays

P Output Ratings. Dimensions and Weights. Prime Rating

PEGASUS MASTER. 12-channel Digital Dimmer. User s manual. Sixth edition

multi-function meters

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

DC POWER SYSTEMS CATALOG

llen-bradley 194R-HM4-NFPA3

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

DMX512 Digital Dimmer Operator Manual

AF-300 E11 Adjustable Frequency Drive

420 LED/Buzzer Combination

Operating instructions Electronic preset counter Type series 717

Flygt D 8050, 50 Hz. Technical specification

Electromechanical Relays

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

ETC. ColorSource Series ORDERING INFORMATION GENERAL INFORMATION. ColorSource PAR

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

Parts List _2.1. Flygt /.190

Ultra Quiet Series Electric Air Handler

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

8 Installation Equipment

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Single Point Flow Monitor SW118 SW119

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

Fibre Optic Chandeliers

P1350P1/P1500E1 50Hz

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

ChromaRange ~ ChromaZone

Flygt Handleiding voor installatie, bediening en onderhoud

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Kuhnke Technical Data. Contact Details

CONCRETE CONSOLIDATION

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

DRAÍOCHT Technical Specification: MAIN SPACE

one M2M Logo Brand Guidelines

Incremental Hollow Shaft Encoder

Alternator. Ratings Book. Industrial. Edition 2

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

A-Line LOUDSPEAKER SYSTEM. Mobile Audio Concert Sound Fixed Installation Pro Entertainment. English

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

part numbers 5 VDC ±5% 5 VDC ±5% 35 ma 30 ma RS 422 3,2 MHz < 4 VDC 160 khz RS 422

ADE-60 4:4 MIX UTILITY

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Bulletin 100-G IEC Contactors

Grounding-type plugs and sockets K Product information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Touch Panel Display Module

COLOUR CHANGING USB LAMP KIT

Magic Patch Patch Leads & Accessories

REGULACE AUTOMATIZACE BOR spol. s r.o.

QUAD LFO MANUAL V SE 14TH AVENUE PORTLAND OR USA

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

50 Hz 60 Hz VOLTAGE Connections

NEW NEW NEW. Page 137. Page 138. Page 128. Page 136. Page 134. Page 134 Page 139

PROCESS HEAT. From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how.

TM Load-regulated locomotive decoder

GENMARK Engineering & Management # Street Edmonton, AB T5S 1R5 CANADA Phone (780) Fax (780)

Certificate of Calibration

Series description: Wilo-Drain VC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Selection guide siemens.com/sirius-modular-system

1. Technology: Solar PV 2. Maximum Power: 50 kw 3. Contribution to fault levels: N/A 4. Size & rating of the relevant Transformer: N/A 5.

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

Series Digital Dimmer. User Manual (VER: 2.0) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD

brand guidelines march 2013

Transcription:

MAINS DISTRIBUTION GUIDE

USEFUL MAINS CALCULATIONS & INFORMATION All calculations are for guidance only and should be used in conjunction with BS7909 guidelines. Watts to Amps 1000 Watts @ 230v = 4.35 Amps 2000 Watts @ 230v = 8.70 Amps 3000 Watts @ 230v = 13.05 Amps Amps to Watts Blinding Light Cable Colour Coding Yellow = 2m 10 Amps @ 230v = 2300 Watts 16 Amps @ 230v = 3680 Watts 20 Amps @ 230v = 4600 Watts 32 Amps @ 230v = 7360 Watts 63 Amps @ 230v = 14,490 Watts 125 Amps @ 230v = 28,750 Watts Generator KVA Ratings Results are based on a generator producing 400v 3 phase at 50Hz with a 0.8 power factor. Grey = 5m Blue = 10m Red = 15m 100 KVA = 80kw / 144 Amps 150 KVA = 120kw / 217 Amps 200 KVA = 160kw / 289 Amps 300 KVA = 240kw / 433 Amps 400 KVA = 320kw / 577 Amps Mains Cable Ratings - H07RN-F All calculations given are based on max Amps in free air. 25mm Cable Diameter = 142 Amps 35mm Cable Diameter = 162 Amps 50mm Cable Diameter = 198 Amps 70mm Cable Diameter = 256 Amps 95mm Cable Diameter = 314 Amps 120mm Cable Diameter = 365 Amps 150mm Cable Diameter = 422 Amps Purple = 20m Purple / Grey = 25m Green = 30m Orange = 40m Brown = 50m

SINGLE PHASE DISTRIBUTION Type 1-1 16a 1ph 6x 13a, 1x 16a N/A Type 1-2 16a 1ph 4 x 16a N/A

Type 1-3 32a 1ph 4x 16a, 1ph 2x C Type 16a MCB Type 1-4 32a 1ph 4x 16a 1ph 4x 16a MCB Type 1-5 32a 1ph 4x 16a 4x 16a MCB, 1x 32a 30ma DP RCBO

Type 1-6 32a 1ph 32a 1ph 32a 1ph RCBO Type 1-7 63a 1ph 1x 63a, 2x 32a & 4x 16a 1ph All outputs individual 30ma RCBO, Overall 63a DP MCB Type 1-8 63a 1ph 2x Socapex (paired) 6x 16a RCBO, 1x 63a DP MCB

THREE PHASE DISTRIBUTION Type 3-1 32a 3ph 3x 32a 1ph (1 per phase) Each outlets individual 32a 30ma DP RCBO Type 3-2 32a 3ph 32a 3ph & 6x 16a 1ph 6x 16a 30ma DP RCD 32a 3ph Unprotected

Type 3-3 32a 3ph 32a 3ph & 6x 16a 1ph 1x 40a 30ma RCD, 1x TPD Type 32a MCB 6x 16a SP C Type MCB 32a 3ph thru MCB & EL Protected Type 3-4 Vari RCBO Type 3-5 RCBO

Type 3-6 2x Overall Vari RCBO Type 3-7 3x 32a 1ph, 12x 16a (1x32a & 4x 16a per phase) 1 x 63A TP MCB 3 x 32A 30ma DP RCBOs 12 x 16A 30ma DP RCBOs Type 3-8 2 x 32a 3ph 2 x 32a 30ma TP RCBO

Type 3-9 3 x 63a 1ph 3 x 63a 30ma DP RCBO 3 x 63a DP MCB s Type 3-9A 3x 63a 1ph 1 x (No ) 3 x 63a 30ma DP RCBO 3 x 63a DP MCB s Type 3-10 1x, 6 x 32a 1ph 2x 32a 3ph 1x TP RCBO 6 x 32a 1ph DP RCBO 2 x 32A 3ph TP RCBO

Type 3-11 125a 3ph 125a 3ph Vari RCBO (switchable) Type 3-12 125a 3ph 2x Vari RCBO per outlet Type 3-13 Powerlock 3 x 3x TP 63a MCB

Type 3-14 Powerlock 2 x 125a 3ph 2x 125a MCB Type 3-15 Powerlock (160-400a) c/w Vari MCCB 2x Powerlock - 2x 200a vari MCCB (200a>126a) adjustable/ switchable EL 1x Powerlock - 1x 400a vari MCCB (400a>160a) adjustable/ switchable EL, 3x - 4 Pole MCB protected c/w adjustable/switchable EL 13a 16a & 32a 1ph - 2 pole 30ma RCBO protected

Type 3-16 Powerlock 3ph 2 sets of Powerlock 3 phase N/A Type 3-18 Powerlock (160-400a) c/w Vari MCCB 2x Powerlock - 2x 200a vari MCCB (200a>126a) adjustable/ switchable EL 1x Powerlock - 1x 400a vari MCCB (400a>160a) adjustable/ switchable EL,1x 32a 3ph - 3 Pole MCB protected c/w Earth Leakage 13a 16a & 32a 1ph - 2 pole 30ma RCBO protected Type 3-19 3ph Powerlock 3ph Powerlock x2 3ph Powerlock x1 (Through) 400A 3P MCCB

Type HP1 1x Through, 3x Soca (1 per phase) 63a TP MCB with variable earth leakage Relay MCB, 18x 16a RCBO Type HP2 1x, 3x Soca, 18x 16a (1x Soca & 6x 16a per phase) 1x Vari RCBO, 18x 16a RCBO

Type HP3 125a 3ph &4x Socapex (Phasing Soca1&2-L1, Soca3-L2,Soca-L3) 63a TP MCB c/w RCCB 4x63a RCCD/Socapex 24x16a C Type MCB Type HP4 3 Phase Powerlock & 6x Socapex (2 per phase) 36x 16a RCBO, 63x MCB, 1x 16a DP RCBO Type HP5 3ph Powerlock 3ph Powerlock, 63a 3ph 6x Soca (2 per phase) 400A MCB, 63a TP MCB c/w Vari EL 36 x 16a 2p 30ma RCBO

Type HP12 3ph Powerlock 3ph Powerlock (Through), 1x Schuko, 1x 13a, 7x 16a, 32a 3ph,, 12x Soca (4 per phase) 72x RCBO 16a/C/30ma 2p 9x RCBO 16a/C/30ma 2p 1x MCB 32a/C/3p + RCD 40A 30MA 4p 1x MCB 63a/C/3p + RCD 63A 30MA 4p

Blinding Light Ltd. 2017 Unit 11 Bilton Road, Kingsland Business Park, Basingstoke, RG24 8LJ Tel: +44 (0)118 988 4422 Email: sales@blinding-light.co.uk Follow us @blindinglightuk www.blinding-light.co.uk Registered in England & Wales 4125167