POWERSCOUT SERIES FEATURES NETWORKED POWER METERS HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

TED Pro Energy Monitoring and Control System

MULTIS L72. Operating instructions

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. STV-4101: V 30A (18) IEC C13 + (6) IEC C19 Outlets

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Cisco RF Gateway 1. Product Overview

MAP110 AC-DC Series Data Sheet

OPERATING MANUAL FIXED FLOW PUMP DRIVES

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

OmniStream R-Type. Single-Channel Networked AV Decoder. Introduction. Applications

IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

GV2ME. Main. Device short name. Device application

02/11/2015

OmniStream R-Type. Dual-Channel Networked AV Encoder. Introduction. Applications

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

HOBO H Energy Logger

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

GV2ME. Main. Device short name. Device application

PRINCIPLES AND APPLICATIONS

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

WATCHMASTER IP THERMAL SURVEILLANCE SYSTEMS

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Thermocouple and RTD Modules for Compact FieldPoint

Advanced Test Equipment Rentals ATEC (2832)

Power Quality Solutions

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Harmonic correction unit (HCU2)

multi-function meters

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Certificate of Calibration

Ethernet to VGA over IP Converter

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

FEATURES. Measurement and Verification (M&V) Studies Electrical Load Profiling Energy Audits New Technology Assessment Studies

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

ADN-8126 JJTRON Display System

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

watchmaster IP Thermal surveillance systems

Cisco RF Gateway 1. Product Overview

Series CT7N Bimetallic Overload Relays

IP Roombox. Hotel Room Management

WVR500 Waveform/Vector Monitor

Rack mounted telephone- and leased line modem for industrial applications

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Satellite Up- and Downconverter Indoor / Outdoor

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

GV2P05. Main. Device short name. Device application

Users Manual. Stroboscope. September 2014

OmniStream. Dual-Channel Networked AV Encoder. Introduction. Applications

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

InterReach Fusion Data Sheet

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

VideoPlex4000 Video Wall Controller - 4K, HDMI

OmniStream. Dual-Channel Networked AV Decoder. Introduction. Applications

LCD Display Wall Narrow Bezel Series

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

DLE Family. Intelligent LED High Bay Fixtures. Product Family Features:

Technical Specifications

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Professional 4-Channel DVB Receiver and Transmodulator Item: 5213

ACC2 DECODER Controller

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Synthesized Block Up- and Downconverter Indoor / Outdoor

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

LandRake HYC V 4006-MIMO Series 4GHz PTP / NATO Mobile Mesh Series

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Bulletin 190 IEC Modular Starter System

FOREST SHUTTLE S / L / M RECEIVER

HAL Series. Versatile range of production line testers.

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Omega 4K/UHD Three-Input Switcher. Introduction. Applications. for HDMI and USB-C with HDBaseT and HDMI Outputs

ALLEN BRADLEY TIMING RELAY

User Manual Power and Harmonics Analyzer Model PQ3350

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Transcription:

PowerLogic power-monitoring units multi-circuit energy meters Technical data sheet

Functions and characteristics PE86326 PE86325 multi-circuit energy meter front (above), installed in panel (below) The compact PowerLogic multi-circuit energy meter from Schneider Electric enables reliable metering of individual tenants with a low installation cost-per-point by combining revenue-accurate electricity sub-metering with advanced communications technology. The EM4800 is ideal for multi-tenant or departmental metering applications within office towers, condominiums, apartment buildings, shopping centres and other multi-user environments. The PowerLogic meters monitor up to 24 tenants with a single device. Multiple meters can be combined to support an unlimited number of suites. Three meter models offer a choice of CT secondary ratings and installation options: PowerLogic EM4805: 5 A, split- or solid-core CTs PowerLogic EM4833: 0.333 V, split- or solid-core CTs PowerLogic EM4880: 80 ma, solid-core CTs Applications Multi-tenant metering. Energy management. Energy cost allocation. Utility bill verification. Main characteristics Compact, maintenance-free design Requires no floor space. Hi-density, flexible connection From single-pole to single- or three-phase metering -- supports up to 24 circuits. Select the connection type using an intuitive configuration tool. Direct connection For 100-300 V ac L-N electrical distribution systems: 120/240 V, 120/208 V, 230/240 V, 220/380 V, 240/415 V, 277/480 V Multiple CT types Support a variety of needs in both new and retrofit installations. 1/3 V output CT option does not require shorting blocks, making it the ideal choice for retrofit installations. No rewiring required Use existing wiring to connect to existing panels. Integrated communications Onboard Ethernet and modem allows for easy integration into existing communications networks. Part numbers Model Description Part number EM4805 24 x 5 A inputs, 230/240 V control power, 50 Hz METSEEM480525 24 x 5 A inputs, 120 V control power, 60 Hz METSEEM480516 EM4833 24 x 333 mv inputs, 230/240 V control power, 50 Hz METSEEM483325 24 x 333 mv inputs, 120 V control power, 60 Hz METSEEM483316 EM4880 24 x 80 ma inputs, 120 V control power, 60 Hz METSEEM488016 2 2014

Functions and characteristics (cont.) PE86327A PowerLogic digital panel meter. Selection guide EM4805 EM4833 EM4880 General Use on LV systems b b b Accuracy +/- 0.5% b b b b b b Accuracy compliance Maximum circuits: single-pole / single phase / three-phase Instantaneous rms values ANSI C12.1 and C12.20 Class 0.5; IEC 62053-22, Class 0.5S 24 / 12 / 8 b b b Energy real, kwh received/delivered b b b reactive, kvarh received/ b b b delivered apparent, VAh b b b Voltage b b b Pulse counts b b b Voltage and current V rms, I rms per phase b b b Power real, reactive, apparent b b b Power factor b b b Measurements available for data logging Energy real, kwh received/delivered b b b reactive, kvarh received/ b b b delivered apparent, VAh b b b Voltage b b b Display Backlit LCD display 2 lines of 16 characters b b b Optional remote modular display available b b b Communication Ethernet port b b b V.90 modem port b b b Pulse inputs 2 b b b Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP b b b Installation options 5 A CTs b 0.333 V CTs b 80 ma CTs b Split core CT b b Solid core CT b b b Remore modular display b b b 2014 3

Functions and characteristics (cont.) Electrical characteristics Input-voltage Inputs characteristics Measured voltage Frequency range V1, V2, V3, Vn 80-480 V AC L-L without PTs Up to 999 kv with external PTs 50/60 Hz Mechanical characteristics Weight EM4805 approx. 5.4 kg EM4833 / EM4880 approx. 4.0 kg Dimensions EM4805 33.5 cm x 44 cm x 5.5 cm (13.125 in x 17 in x 2.125 in) EM4833 / EM4880 33.5 cm x 30.5 cm x 5.5 cm (13.125 in x 12 in x 2.125 in) Environmental conditions Operating temperature -40 C to +70 C (-40ºF to +158 F) Storage temperature -40 C to +70 C (-40ºF to +158 F) Humidity rating 0% to 90 % RH non-condensing Enclosure Type 1 (indoor or enclosed outdoor use) Altitude 3000 m (9843 ft) Pollution degree 2 Safety and standards UL Certified to IEC/EA/CSA 61010-1 CSA-C22.2 No 61010-1-04 FCC Part 15 Class B ICES-003 EN55022, IEC 6100-4-5 ANSI/TIA968-A: 2002 Communication Ports Ethernet V.90 modem Pulse inputs 2 Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP Display characteristics Integrated backlit LCD display 2 ines, 16 digits per line display; R / L arrow buttons select metering point; Display button cycles through measurements per point. 4 2014

Schneider Electric Industries SAS 35, Rue Joseph Monier, CS 30323 F - 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 www.schneider-electric.com As standards, specifications and designs develop from time to time, please ask for confirmation of the information given in this document. This document has been printed on recycled paper Design: Schneider Electric Photos: Schneider Electric 10-31-1247 ART 960558 / 2014 - Schneider Electric - All rights reserved PLSED310030EN 06-2014