AF-300 E11 Adjustable Frequency Drive

Similar documents
BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

ADJUSTABLE SPEED DRIVES. nc1 Drive

VAT 20 Adjustable Frequency Drive

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Frequency Converter Fv

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

02/11/2015

Frequency Converter EFC 3610, EFC 5610

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Understanding VFD. Variable Frequency Drive. nfi. nfi

Product Catalog Frequency Converters

Inverters Selection Guide

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Variable Speed Drives OMRON/YASKAWA F7Z - series

SCALE & WEIGHT DISPLAYS

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Frequency Converter EFC 3610, EFC 5610

LAUREL ELECTRONICS, INC.

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Absolute Rotary Encoder E6CP

Inverters Selection Guide

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Series CT7N Bimetallic Overload Relays

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

MICROMASTER Encoder Module

RM5 User Manual Warnings.

Material: Weight: IP Rating: Cable: Connector:

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

High performance circuit breakers

MAP110 AC-DC Series Data Sheet

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Bulletin 150, 154 Softstarters Quick Selection Table

Wall-/Pipe-Mount Level Indicator

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Direct PWM. 1000/2000 Series POWERBLOK MODULE

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Fibre Optic Modem ODW-611

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

LED Driver Compact fixed output

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit.

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

ODW-621. RS-232 Point-to-point applications

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

HS-509 VIBRATION TRIP MODULE

LED Driver Compact dimming

Frequency Converter EFC 3610, EFC 5610

Generator protection relay

Basic, cost-effective motor control in one unit: MOVITRAC 07.

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Linear / area fixed output

LED Driver Compact fixed output

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Process Transmitter RMA 422

Accessories. Servo Motors. Servo Motors B-47. Accessories

GP-500 SERIES - Low Voltage

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

DCP100 Digital Control Programmer Specifications

EA350. Generator Automatic Voltage Regulator Operation Manual

X-Band Redundant LNB Systems

PRINCIPLES AND APPLICATIONS

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Product Catalog Electric Drives and Controls. Frequency Converters IndraDrive Fc

Safety Light Curtains GuardShield

Photoelectric Sensors E3F2

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Standard RS232 RS ma

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Rack mounted telephone- and leased line modem for industrial applications

Variable speed drives Altivar 61

PAM-1840 Preamplifier Operation Manual

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Operating instructions Electronic preset counter Type series 717

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Ku-Band Redundant LNB Systems

ALLEN BRADLEY TIMING RELAY

C-Band Redundant LNB Systems

Transcription:

AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed the AF-300 E11 drive with these features in mind. This product is specifically intended for original equipment manufacturers who require maximum performance in a minimal space for a cost-effective system. INDEX TO SECTION Product Description... -1 Model Numbering System Diagram... -2 Pricing, Dimensions & Weights... -3 Options & Accessories... -4 Dynamic Braking... - Standard Specifications... -6 Dimensional Drawings... -8 Basic Wiring Diagrams... -12-1

AF-300 E11 Model Numbering System Diagram Description 6K E11 2 1 F12 X 1 # # GE Product Code AF-300 Drive Family Input Voltage 2 = 230 Vac 0/60 Hz 4 = 460 Vac 0/60 Hz Input Phase 1 = 1-Phase 3 = 3-Phase Horsepower F0 = 1/2 hp 001 = 1 hp Factory Installed Options X = Keypad Enclosure Type 1 = IP20 Product Revision A = First Revision B = Second Revision Minor Product Revision 1 = First Minor Revision 2 = Second Minor Revision -2

Pricing, Dimensions & Weights Hp Rating Enclosure Output Current (A) Overloard (A) (10% 1min.) Model No. Catalog No. List Price (GO-E11) Dimensions H x W x D (in) Weight (lbs) 230 Vac, 1-Phase, 0/60 Hz Input 1/8 IP20 0.7 1.1 6KE1121F12X1 ## D810 460.12 x 2.76 x 3.78 1.3 1/4 IP20 1.4 2.1 6KE1121F2X1 ## D811 471.12 x 2.76 x 3.98 1. 1/2 IP20 2. 3.8 6KE1121F0X1 ## D812 3.12 x 2.76 x 4.6 1. 1 IP20 4 6.0 6KE1121001X1 ## D813 606.12 x 4.18 x 4.96 2.8 2 IP20 7 10. 6KE1121002X1 ## D814 706.12 x 6.69 x 6.22 4.0 3 IP20 10 1.0 6KE1121003X1 ## D81 88.12 x 6.69 x 6.22 4.3 230 Vac, 3-Phase, 0/60 Hz Input 1/8 IP20 0.7 1.1 6KE1123F12X1## D801 361.12 x 2.76 x 3.78 1.3 1/4 IP20 1.4 2.1 6KE1123F2X1## D802 386.12 x 2.76 x 3.98 1.3 1/2 IP20 2. 3.8 6KE1123F0X1## D803 433.12 x 2.76 x 4.6 1. 1 IP20 4.0 6.0 6KE1123001X1## D804 484.12 x 2.76 x.67 1.8 2 IP20 7.0 10. 6KE1123002X1## D80 6.12 x 4.18 x.91 2.9 3 IP20 10.0 1.0 6KE1123003X1## D806 618.12 x 4.18 x.91 2.9 IP20 16. 24.8 6KE112300X1## D807 860.12 x 6.69 x 6.22 4.4 7. IP20 23. 3.3 6KE1123007X1## D808 1,360 8.66 x 7.09 x 6.22 9..9 10 IP20 31.0 46. 6KE1123010X1## D809 1,42 8.66 x 7.09 x 6.22 9.9 460 Vac, 3-Phase, 0/60 Hz Input 1/2 IP20 1.4 2.1 6KE1143F0X1## D816 6.12 x 4.18 x 4.96 2.4 1 IP20 2.1 3.2 6KE1143001X1## D817 87.12 x 4.18 x.91 2.6 2 IP20 3.7.6 6KE1143002X1## D818 67.12 x 4.18 x 6.7 2.9 3 IP20.3 8.0 6KE1143003X1## D819 783.12 x 4.18 x 6.7 3.1 IP20 8.7 13.1 6KE114300X1## D820 979.12 x 6.69 x 6.22 4.2 7. IP20 12 18.0 6KE1143007X1## D821 1,483 8.66 x 7.09 x 6.22 9.9 10 IP20 16 24.0 6KE1143010X1## D822 1,76 8.66 x 7.09 x 6.22 9.9 ## Indicates product revision -3

Options & Accessories Description Model No. Catalog No. List Price (GO-P11) EMI/RFI Filter 230 V, 1-phase; 1/8, 1/4, 1/2 hp EFL040E117 A3820 62 EMI/RFI Filter 230 V, 1-phase; 1 hp EFL07E117 A3821 76 EMI/RFI Filter 230 V, 1-phase; 2, 3 hp EFL220E117 A3822 8 EMI/RFI Filter 230 V, 3-phase; 1/8, 1/4, 1/2, 1 hp EFL07SP2 A3803 422 EMI/RFI Filter 230 V, 3-phase; 2, 3, hp EFL370SP2 A3801 683 EMI/RFI Filter 230 V, 3-phase; 7., 10 hp EFL70SP2 A3719 1,487 EMI/RFI Filter 460 V, 3-phase; 1/2, 1 hp EFL07E114 A3823 19 EMI/RFI Filter 460 V, 3-phase; 2, 3 hp EFL220E114 A3824 179 EMI/RFI Filter 460 V, 3-phase; hp EFL400E114 A382 198 EMI/RFI Filter 460 V, 3-phase; 7., 10 hp EFL70E114 A3826 239 DeviceNet Serial Communication OPCE11SDEV A3830 690 Profibus DP Serial Communication OPCE11SPDP A3831 720 Interbus-S Serial Communication OPCE11SIBS A3832 810 Modbus Plus Serial Communication OPCE11SMBP A3833 1,030 CAN Serial Communication OPCE11SCOP A3834 790 Serial Communication Branch Adapter OPCE11SRB A383 40 Keypad Adapter for Extension Cable CBAD11S A3840 3 EMI/RFI Filters Fully tested filters that are incorporated into the system for the drive to meet CE requirements. The filter units have been tested with the drives to meet CE guidelines covering electromagnetic and radio frequency interference abatement, EC Directive 89/336/EEC. Serial Communication Branch Adapter Allows for multi-drop connections of the Modbus RTU network. Keypad Adapter for Extention Cable Allows the connection of a standard RJ-4 connector and CAT- cable to the keypad for remote mounting. -4

Dynamic Braking The dynamic braking option has been designed to allow faster deceleration rates then could be achieved via a coast stop. The option consists of a dynamic braking module and dynamic braking resistors. Important application notes: The standard option has been designed for stopping a load with an inertia equal to or less than the applied motor s rotor inertia. High inertia or overhauling loads may cause extended deceleration times which could cause option overheating and tripping of the drive unit. The option is not a holding brake. It will not prevent a motor at rest from rotating. Note: Refer to drive s instruction manual installation and connection section for details. Nominal Applied Motor Hp Max. Braking Torque (%) E11 Dynamic Braking Module Recommended Dynamic Braking Resistor Qty. Required Total Ohms Total kw Cont. Max Braking Time(s) at 100% Torque Repetitive 100% Braking Torque Duty (%) 230 Vac 1/8 10% Built-in DB201TBNC 1 100 0.2 90 37 1/4 10% Built-in DB201TBNC 1 100 0.2 90 37 1/2 10% Built-in DB201TBNC 1 100 0.2 4 22 1 10% Built-in DB202TBNC 1 100 0.2 4 18 2 10% Built-in DB203TBNC 1 40 0.4 4 10 3 10% Built-in DB204TBNC 1 40 0.4 30 7 10% Built-in DB20TBNC 1 33 0.4 20 7. 10% Built-in DB206TBNC 1 20 0.8 20 10 10% Built-in DB207TBNC 1 1 0.9 10 460 Vac 1/2 10% Built-in DB401TBNC 1 200 0.2 4 22 1 10% Built-in DB401TBNC 1 200 0.2 4 10 2 10% Built-in DB402TBNC 1 160 0.4 4 10 3 10% Built-in DB403TBNC 1 160 0.4 30 7 10% Built-in DB404TBNC 1 130 0.4 20 7. 10% Built-in DB40TBNC 1 80 0.8 20 10 10% Built-in DB406TBNC 1 60 0.9 10 Note: Refer to Section 9 - Dynamic Braking Modules & Resistors for pricing, weights, and dimensions. -

Standard Specifications Environmental Conditions Installation Location Altitude Ambient Temperature Ambient Humidity Free from corrosive gases, flammable gases, oil mist, dust, and direct sunlight. Indoor use only. 1000 m or less. Applicable to 3000 m with power derating (-10%/1000 m). -10 C to +0 C (+14 F to 122 F) to 9% RH (non-condensing) Vibration 3 mm: 2 to < 9 Hz 9.8 m/s 2 : 9 to < 20 Hz 2 m/s 2 : 20 to < Hz 1 m/s 2 : to < 200 Hz Storage Condition Input Rated Input AC Voltage Output Setting Accuracy (Stability) Setting Resolution Control Control Method Operation Method Frequency Setting Temperature: -2 C to +6 C (-4 F to 149 F) Humidity: to 9% RH (non-condensing) 200 to 240 Vac 0/60 Hz, 1-phase (1/8 to 3 hp) 200 to 230 Vac 0/60 Hz, 3-phase (1/8 to 10 hp) 380 to 480 Vac 0/60 Hz, 3-phase (1/2 to 10 hp) Voltage: -1% to +10%; voltage unbalance: within 3%; frequency ± % Maximum frequency: 0 to 400 Hz Base frequency: 2 to 400 Hz Starting frequency: 0.1 to 60.0 Hz; holding time: 0.0 to 10.0 s Carrier frequency: 0.7 to 1 khz Digital setting: ±0.01% of maximum frequency (from -10 C to +0 C) Analog setting: ±0.2% of maximum frequency (at 2 C ± 10 C) Digital setting: 0.01 Hz at maximum frequency up to 99.99 Hz (0.1 Hz at maximum frequency of 100.0 Hz and above) Analog setting: 1/3000 of maximum frequency (e.g. 0.02 Hz at 60 Hz, 0.04 Hz at 120 Hz, 0.1 Hz at 400 Hz) Link setting: 1/20000 of maximum frequency or 0.01 Hz fixed (e.g. 0.003 Hz at 60 Hz, 0.006 Hz at 120 Hz, 0.02 Hz at 400 Hz) V/F control (sinusoidal PWM control) Dynamic torque vector control (sinusoidal PWM control) Keypad operation: RUN or STOP key Digital input signal: Forward/reverse command, coast-to-stop command, etc. Link operation: RS48 (standard), Profibus-DP, Interbus-S, DeviceNet, Modbus Plus, CAN Open (option) Keypad operation: UP or DOWN keys External potentiometer of 1 to k ohm Analog input: 0 to +10 Vdc (0 to + Vdc), 4 to 20 ma dc Multi-step frequency: Up to 16 different frequencies can be selected by digital input signal Link operation: RS48 (standard), Profibus-DP, Interbus-S, DeviceNet, Modbus Plus, CAN Open (option) -6

Standard Specifications (continued) Acceleration/Deceleration Time Voltage/Frequency (V/F) Characteristics Restart After Momentary Power Failure Frequency Limiter Bias Frequency Jump Frequency Control Torque Boost Protection Overload Overvoltage Overheating Motor Overload Motor Protection by PTC Thermistor Options Standard Communications Mounting Space 0.01 to 3600 s (independently adjustable acceleration and deceleration; two different times are selectable) Adjustable at base and maximum frequency with AVR control: 320 to 480 V (460 V series), 80 to 240 V (230 V series) Drive restarts without causing the motor to stop if the automatic restart is specified for the drive High and low limiters can be preset Bias frequency can be preset (-400 to +400 Hz) Jump frequency (3 points) and its common jump hysteresis width (0 to 30 Hz) can be preset Selectable by load characteristics: constant torque load (auto/manual), variable torque load (manual) Protects the drive by electronic thermal and detection of drive temperature Detects dc link circuit overvoltage to stop drive (460 V series - 800 Vdc; 230 V series - 400 Vdc) Protects the drive by detection of drive temperature Electronic thermal overload relay can be selected for standard motor or drive motor When the motor temperature exceeds allowable value, the drive trips automatically EMI filters, DB resistors Profibus-DP, Interbus-S, DeviceNet, Modbus Plus, CAN Open (option) 4 (10cm) P R G RESET FUNC DATA RUN STOP 0.4 (1cm) 0.4 (1cm) 4 (10cm) -7

Dimensions Model No. Nominal Applicable Motor External Dimensions (in) Hp D D1 D2 D3 6KE1123F12X1** 1/8 3.78 3.3 1. 0.39 6KE1121F12X1** 6KE1123F2X1** 1/4 3.98 3. 1.7 0.9 6KE1121F2X1** 6KE1123F0X1** 1/2 4.6 4.22 2.37 1.26 6KE1121F0X1** 6KE1123001X1** 1.67.24 3.39 2.28 ** Indicates product revision -8

Dimensions Model No. Nominal Applicable Motor External Dimensions (in) Hp D D1 D2 D3 D4 6KE1123002X1** 2.91.46 3.41 2.2 3.39 6KE1123003X1** 3.91.46 3.41 2.2 3.39 6KE1121001X1** 1 4.96 4.1 2.46 1.7 3.39 6KE1143F0X1** 1/2 4.96 4.1 2.46 1.7 3.39 6KE1143001X1** 1.91.46 3.41 2.2 3.39 6KE1143002X1** 2 6.69 6.24 3.41 2.2 4.17 6KE1143003X1** 3 6.69 6.24 3.41 2.2 4.17 ** Indicates product revision -9

Dimensions Nominal Model No. Applicable Motor Hp 6KE112300X1** 6KE1121002X1** 2 6KE1121003X1** 3 6KE114300X1** ** Indicates product revision -10

Dimensions Nominal Model No. Applicable Motor Hp 6KE1123007X1** 7. 6KE1123010X1** 10 6KE1143007X1** 7. 6KE1143010X1** 10 ** Indicates product revision -11

Basic Wiring Diagrams Power supply 1-phase 200 to 240 V 0/60 Hz * MCCB or ELCB L1/L L2/N * External braking resistor (DB) 2 (CM) 1 G P DB (THR) P (+) DB Power supply 3-phase 380 to 480 V 0/60 Hz or 200 to 230 V 0/60 Hz * MCCB or ELCB L1/R L2/S L3/T G U V W G P1 P1 * Motor M Analog input Voltage input (0 to +10 Vdc) 3 2 1 13 12 11 P (+) DB N (-) (*1) P (+) E *Where dc reactor is used Current input (4 to 20 ma dc) C1 30 30C 30B Alarm output (for any fault) Digital input Forward command Reverse command Analog monitor PLC FWD REV X1 X2 X3 X4 X CM FM 30A P24 Y2 Y1 CME Analog/ pulse changeover switch Transistor output FM Pulse counter (* Digital freq. meter) To terminal 11 Analog meter To terminal 11-12