LIGHTS SO ADVANCED, THEY RE BRILLIANT EVEN BEFORE THEY RE TURNED ON.
WELCH ALLYN LS-0 HALOGEN EXAM LIGHT Totally re-engineered for enhanced performance and accuracy, our premium-quality 0 watt exam light delivers brilliant color and convenience. 0 WATT LAMP delivers superior light quality across the variable spectrum for more accurate color rendition. SPECIALLY REDESIGNED LIGHT HEAD keeps luminaire cool to the touch even during multiple exams. Lamp has been offset at a angle relative to the luminaire housing, allowing an unobstructed view of the field of interest. REDUCED BASE PROFILE frees up valuable exam room floor space. ENCASED, FLEXIBLE " ARM enables accurate one-hand positioning you don t get with conventional gooseneck units. MULTIPLE INSTALLATION OPTIONS including floor stand with optional caster base, wall-mounted, and tablemounted enable you to customize your setup to best meet your needs. Optional Caster Base (LS-0 and LS- models) Optional Wall-mounted version
WELCH ALLYN LS- HALOGEN EXAM LIGHT A unique blend of intense light output, superior performance, and affordability makes this the perfect choice for almost any type of in-office exam. LONG-LASTING WATT HALOGEN LAMP produces significantly whiter, brighter light than ordinary gooseneck units. DUAL INTENSITY CONTROL SWITCH allows you to instantly adjust light output to match your exact requirements. MOLDED LEXAN LIGHT HEAD does not conduct heat, keeping luminaire cool to the touch at all times. Lamp has been offset at a angle relative to the luminaire housing, allowing an unobstructed view of the field of interest. LIGHT BASE is compact, freeing up much needed exam room floor space. Smooth surfaces are easy to clean. MULTIPLE INSTALLATION OPTIONS including floor stand with optional caster base, wall-mounted, and table-mounted enable you to customize your setup to best meet your needs.
WELCH ALLYN LS-00 PROCEDURE LIGHT This super-flexible procedure light combines outstanding durability, extraordinary maneuverability, and unparalleled spot quality at an extremely attractive price. COOL WORKING FIELD AND 7" SPOT SIZE with feathered edge definition bring procedure room illumination to a whole new level. UNIQUE THREE-LAMP DESIGN enables continuous operation and shadow-free illumination. END-USER FRICTION ADJUSTMENTS at key joint ensure drift-free, obedient articulation.,000 HOUR LOW-VOLTAGE HALOGEN BULBS in dichroic reflectors render truer tissue color than ordinary units. MULTIPLE INSTALLATION OPTIONS including wall-mounted, mobile stand, and table-mounted versions accommodate any setup. WELCH ALLYN SOLARC HEADLIGHT Faster, more efficient procedures are made possible by the Solarc Headlight System. Offers all the advantages of a traditional procedure light, and then some: PREMIUM SHADOW-FREE WHITE LIGHT, exactly where you need it... every time, all the time. SOLARC TECHNOLOGY provides massive amounts of white light at 00 K for very accurate tissue color rendering. LONG-LIFE SHIELDED FIBEROPTIC BUNDLE ensures years of dependable service. TRIPLE-LINK LUMINAIRE SUSPENSION SYSTEM is loupe friendly and allows true, shadow-free, coaxial illumination. BUILT TO HOSPITAL STANDARDS, priced for an office budget.
WELCH ALLYN EXAM LIGHT III FIBEROPTIC LIGHT Sleek, rugged, and ultra-efficient, our revolutionary new fiberoptic exam light is a must-have for every busy practice. HIGHLY FLEXIBLE FIBEROPTIC LIGHT PIPE is twice as long as conventional pipes but does not droop or wander like ordinary units. COMPACT, UNOBTRUSIVE HEAD ensures pinpoint accuracy while providing cool, consistent illumination on task area. WHITE, BRIGHT LIGHT ensures truer tissue color rendition than most ordinary lights. LIGHTWEIGHT FOCUSING SLEEVE with optics provides a variable, homogeneous spot. MULTIPLE, SPACE-SAVING MOUNTING OPTIONS including wall, mobile stand, and table versions accommodate any setup. Midmark Table Mount EXAM LIGHT III FIBEROPTIC LIGHT CABLE Our high-performance hand held light is smaller, lighter, and brighter than most other portable exam lights on the market. LIGHTWEIGHT UNIT fits in the palm of your hand for precise task lighting. FLEXIBLE 7.' FIBEROPTIC CABLE WITH FOCUSING SLEEVE enables effortless head-to-toe reach across the exam table. BUILT-IN COOLING SYSTEM completely dissipates heat, keeping unit cool to the touch. WALL-MOUNTED HOLDER protects instrument from damage and reduces exam room clutter. Accommodates left- or right-side installation. INTERCHANGEABLE with Exam Light III fiberoptic light pipe box.
SPECIFICATIONS LS-00 PROCEDURE LIGHT LUMINAIRE Diameter Material KEY MEASUREMENTS Arm Wall Extension Arm Wall to Luminaire Center Mobile Stand Height Mobile Stand Legs Length Width Height Mobile Stand Base Length Width Height ILLUMINATION Intensity COLOR TEMPERATURE WORKING DISTANCE SPOT SIZE DEPTH OF FIELD (±6 ) LAMPS (DICHROIC REFLECTOR) 9." ( cm) Lexan 90 Polycarbonate 0" ( cm) " (0 cm) 0" (0 cm) (90 degrees to wall) 6" (7 cm) 6" (0 cm) " ( cm) " ( cm) 6" (0 cm) 8" (6 cm)." ( cm),00 foot candles average at " (60 cm),000 lux at 9.68" (0 cm),000 at." (80 cm),00 degrees Kelvin " (60 cm) 7" (8 cm) " total (0 cm),000 hour average lamp life CORD LENGTH Output Cord ' (. m) Input cord (detachable) 8' (. m) AGENCY APPROVAL Listed to UL for Class Medical Equipment CSA C.- for Class G Medical Equipment IEC 60- for Class, Type B Medical Equipment EXAM LIGHT III COLOR TEMPERATURE FOOT CANDLES FOCUSING SLEEVE SPOT SIZE,00 Kelvin 70 (8070 LUX) of a " (0.6 cm) spot at 6" (0.6 cm) Adjusts from " (0.6 cm) to 0" (. cm) at 6" (0.6 cm) FEATURES Flexible fiberoptic light pipe for cool distal light. Non-drift light pipe with 60 degree rotation ensures fixed position in any plane. Disposable sheaths available to prevent cross-contamination. Special light pipe available for neonatal transillumination. POWER CORD #8 AWG, wire grounded cord set 8' (. m) long PHYSICAL CHARACTERISTICS Weight (light box only).7 lb. (.6 Kg) Light Box Dimensions Height 8.7" (. cm) Width." (. cm) Depth." (8.89 cm) CONFORMS TO THE FOLLOWING AGENCY REQUIREMENTS: UL 60- CAN/CSA C. No. 60. IEC 6060- AS 00. C-Tick EMC Framework of Australia CE (9//EEC)
SPECIFICATIONS LS-0 HALOGEN EXAMINATION LIGHT LAMP WATTAGE 0 watts VOLTAGE volts COLOR TEMPERATURE,700 Kelvin FOOT CANDLES 76 FACE LUMENS 6,0 Peak Lux at " LAMP LIFE,000 continuous hours BEAM SPREAD degrees INFRA RED ENERGY FILTERED 8% less than standard 0 watt lamps SPOT SIZE " working distance 6" spot size 6" working distance 8" spot size 0" working distance 0." spot size " working distance " spot size FLEXIBLE ARM LENGTH " POLE HEIGHT 0" BASE DIAMETER " CONFORMS TO AGENCY REQUIREMENTS: See below* LS- HALOGEN EXAMINATION LIGHT LAMP WATTAGE watts DUAL VOLTAGE High intensity volts Low intensity 0 volts COLOR TEMPERATURE High intensity,000 Kelvin Low intensity,868 Kelvin FOOT CANDLES FACE LUMENS (all light collected out of the face of the lamp) High intensity 6 Low intensity 66 LAMP LIFE,000 continuous hours BEAM SPREAD 0 degrees SPOT SIZE " working distance " spot size 6" working distance= 7" spot size 0" working distance = 9." spot size " working distance =." spot size FLEXIBLE ARM LENGTH " POLE HEIGHT 0" BASE DIAMETER " *CONFORMS TO THE FOLLOWING AGENCY REQUIREMENTS: Class Equipment Continuous Operation ETL listed: UL60-, CSA C. No. 60., IEC 6060-, AS 00., IEC 6060-- Australia EMC Framework Compliance The CE mark on this product indicates that it has been tested to and conforms with the provisions noted within the 89/6/EEC Electromagnetic Compatibility Directive. SOLARC HEADLIGHT ILLUMINATION SOURCE Welch Allyn Solarc Lamp, W COLOR TEMPERATURE,00 Kelvin AVERAGE LAMP LIFE 0 hours SPOT SIZE RANGE 0 mm - 7 mm CONFORMS TO THE FOLLOWING AGENCY REQUIREMENTS: UL 60- CSA C. 60 IEC 60- CE marking to Electromagnetic Compatibility Directive 89/6/EEC and Low Voltage Directive Australia AS00 EN 0 Detailed specs available upon request
MEASURING THE TRUE EFFECTIVENESS OF A LIGHT. Most physicians desire bright, intense light emitted in a shadow-free spot to aid them in rendering an accurate differentiation of anatomical features for proper diagnosis of medical conditions. There are many factors that make up how one perceives an illuminated object. The perceived color and intensity of the light beam emitted from a spot light source is heavily influenced by the surrounding ambient lighting conditions. Also, there are many properties of an individual s own vision system (in particular, the health and age of one s corneas, rods and cones) that influence their visual perception. That s why two of the more important metrics of a light source are intensity and color. There are several ways to quantify the intensity and color of a light source. Welch Allyn utilizes footcandles (fc) for intensity and correlated color temperature (CCT) in degrees Kelvin ( K) for color. For reference, the CCT of daylight on a sunny day at noon is about 600 K, whereas a room with no windows being lit by incandescent bulbs will have a CCT of about 000 K. Taking all these variables into consideration, Welch Allyn has developed a family of exam lights that offer a range of intensity and CCT in order to augment the ambient lighting conditions as well as the variations in the physician s visual system. Call -800--666 today and one of our medical lighting experts will help you determine which light sources and configurations best meet your specific needs.
INTRODUCING THE REVOLUTIONARY NEW FAMILY OF MEDICAL LIGHTING PRODUCTS FROM WELCH ALLYN. NEW LS-0 Developed by the company whose name is synonymous with superior performance, they re the first medical lights advanced enough to make ordinary lights seem just that: NEW LS- ordinary. Each model features a sleek, rugged design, and offers some of the most welcome advances in medical lighting technology ever flexible arms that don t wander or droop, LS-00 heads that stay cool to the touch, superior illumination, longer-lasting bulbs, and much more. Designed to meet the demanding specifications of medical professionals like you, our new medical lights SOLARC HEADLIGHT do more than simply provide illumination. They set new standards for comfort, mobility, ease-of-use, and productivity. So take a closer look and see for yourself how well they ll NEW EXAM LIGHT III fit in with your new or existing office setups. We re confident you ll like what you see.
YOUR SOURCE FOR SUPERIOR MEDICAL LIGHTING. Superb engineering, sleek design, superior illumination, lasting value. These are the hallmarks of Welch Allyn Lighting products. Providing brilliant medical lighting solutions for over 80 years, we go the extra mile to provide the high-quality light sources and configurations you need to diagnose more effectively and perform more efficiently. For more information on our new family of precision lighting products, call -800--666 or e-mail infomedical@welchallyn.com. Or visit us at www.welchallyn.com. ORDERING INFORMATION LS- 00 LS- Halogen Examination Light, complete with integral floor stand, 0-0V, 60Hz for North America 0 Same as 00 but for export (please specify country and voltage) 0 LS- Wall/Table Mount, 0-0V, 60Hz for North America Same as 0 but for export (please specify country and voltage) 0 Table clamp accessory for 0 and 0 Caster Base accessory for 00 and 0 00 W Halogen Replacement Lamp for LS- LS-0 00 LS-0 Halogen Examination Light, complete with integral floor stand, 0-0V, 60Hz for North America 0 Same as 00 but for export (specify country and voltage) 0 LS-0 Wall/Table Mount, 0-0V, 60Hz for North America Same as 0 but for export (please specify country and voltage) 0 Table clamp accessory for 0 and 0 Caster Base accessory for 00 and 0 00 0W Halogen Replacement Lamp for LS-0 LS-00 00 LS-00 Procedure Light, Arm and Luminaire Section 0 Same as 00 but for export (please specify country and voltage) 0 LS-00 Wall Mount 0 LS-00 Mobile Stand 0600 Halogen Replacement Lamp for LS-00 EXAM LIGHT III 8700 Exam Light III with Fiberoptic Light Pipe, complete with focusing sleeve, wall mount and power cord 87 Same as 8700 but for export (specify country and voltage) 8760 Exam Light III with Neonate Light Pipe, complete with wall mount and power cord 876 Same as 8760 but for export (specify country and voltage) 880 Mobile stand for Exam Light III 889 Universal Table Mount 87 Same as 870 but for export (specify country and voltage) 000 W Replacement Lamp for Exam Light III EXAM LIGHT III FLEXIBLE FIBEROPTIC LIGHT CABLE 8780 Exam Light III with 7.' Flexible Fiberoptic Cable, complete with focusing sleeve, wall mount and power cord 878 Same as 8780 but for export (specify country and voltage) 80 7.' Flexible Fiberoptic Cable with focusing sleeve 000 W Halogen Replacement Lamp for Exam Light III SOLARC HEADLIGHT 90 MFI Solarc Headlight System (light source, fiber bundle, headband/luminaire) 90TW MFI Solarc Headlight System with Turret (accepts: Wolf, ACMI, Storz, Olympus) 9 MFI Solarc Headlight System, International Power Cord (specify country) 900 MFI Solarc Light Source only 900TW MFI Solarc Light Source with Turret (accepts: Wolf, ACMI, Storz, Olympus) 90 Solarc Light Source only, International Power Cord (specify country) 90 MFI Solarc Mobile Stand 0900 MFI Solarc Replacement Lamp State Street Road, Skaneateles Falls, NY -00 Tel: (888) 9-9, () 68- Fax: () 68-7 www.welchallyn.com SM6 Rev. B