MAINSTAGE TECHNICAL SPECIFICATIONS

Similar documents
MAINSTAGE TECHNICAL SPECIFICATIONS

MAINSTAGE TECHNICAL SPECIFICATIONS

STUDIO THEATRE TECHNICAL SPECIFICATIONS

HAROLD SHENKMAN HALL 2017 TECHNICAL SPECIFICATIONS

Patriots Theater at the War Memorial Technical Data

Technical Specifications

Technical Information

Technical Specifications and Inventory Spring 2018

SHUBERT THEATER 247 College Street, New Haven, CT

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Jane Mallet Theatre Technical Specifications

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Sandusky State Theatre Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Concert Hall Technical Specifications

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Concert Hall Technical Specifications

Marjorie S. Deane Little Theater

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Hard Rock Cafe Times Square Sound System Advance Sheet

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

JOHN W.H. BASSETT THEATRE

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Main Stage Technical Specs - Hall #2

Technical Services and Specification

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Dr JOHN GALLAGHER CONCERT CHAMBER

TECHNICAL PACKAGE.

Technical Specifications

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications

NORTH CHARLESTON PERFORMING ARTS

Downtown Arts Center Tech Packet. General Information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Bloomington Center for the Performing Arts. Technical Specifications

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Technical Information

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

General & Technical Specifications:

DEREHAM MEMORIAL HALL

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

General & Technical Specifications

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

The Breen Center for the Performing Arts Saint Ignatius High School

Dale F. Halton Theater Technical Specifications

SAINT ANSELM COLLEGE DANA CENTER

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

Technical Specifications. Taylor Little Theater

Matt Dann Cultural Centre

Quick-Advance Fact Sheet

NORTH CHARLESTON PERFORMING ARTS

New Theatre Royal Lincoln Technical Information

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

ISLAND HALL TECHNICAL INFORMATION

Facility Information

Main House Technical Specification

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

The ACT Facility Technical Specifications Main Stage Information

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Dinkelspiel Auditorium - Technical Specifications

Palace Theatre 61 Atlantic Street Stamford, Connecticut

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Director of Production Andrew Quick Ext 252

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

CENTRE FOR PERFORMING ARTS

Directions. Driving directions and other UCSD maps

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Technical Specification

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Technical Specification

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Arcadia Performing Arts Center Technical Specifications and Information

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

Performing Arts Theatre

Ferst Center for the Arts Technical Specifications (Revised May 2016)

Anvil Theatre. Technical Information

Theater Technical Information

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Bartlesville Community Center

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Centre Stage and City Room at Surrey City Hall Venue Information

Technical Specifications

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Technical Information

Transcription:

The 954-seat (730 seat orchestra level & 224 seat balcony) Mainstage is a fully serviced performance venue owned and operated by the City of Ottawa. Excellent sightlines, acoustics and a large proscenium stage make the theatre ideal for all types of performances, large presentations and ceremonies. CONTACT INFORMATION Address Ben Franklin Place 101 Centrepointe Drive Ottawa, ON K2G 5K7 www.centrepointetheatres.com Key Contacts Artistic Producer and Manager Chief, Production Services UNIONS Stage International Alliance of Theatrical Stage Employees (IATSE Local 471) Telephone Administration Box Office Box Office Toll Free Production Allan Sansom Sean Freill (613) 580-2701 (613) 580-2700 (866) 752-5231 (613) 580-2703 (613) 580-2424 x46653 (613) 580-2424 x41527 Administration Canadian Union of Public Employees (CUPE) Civic Institute of Professional Personnel (CIPP) GENERAL INFORMATION Volunteers Non-Profit organizations have access to the Centrepointe Theatres Volunteer Company (CTVC) Stage Crew. In the absence of available volunteers, IATSE union staff will be hired and charged back at the applicable rates. The Licensee shall provide the Volunteer Stage Crew with appropriate meals and refreshments during the engagement at scheduled times as advanced by Centrepointe Theatres Production Services. Haze and Theatrical Smoke Productions using haze and smoke must inform Centrepointe Theatres (CT) in advance of their event. WHMIS 2015 documentation (SDS) must be provided to CT Production Services. Pyrotechnics Productions using pyrotechnic special effects must apply for and receive a permit in accordance with City Of Ottawa bylaw services and obtain authorization from the CT, and the Fire Chief of the City of Ottawa. Operators must hold appropriate certification from the Explosive Regulatory Division of the Natural Resources of Canada. Open Flame / Smoking Policy The City of Ottawa has a No Open Flame policy. Smoking is not permitted in Centrepointe Theatres or anywhere on City of Ottawa property. Theatrical Firearms/Weaponry All firearms, including replica firearms, must be handled in accordance with federal legislation and have advance approval by CT Production Services. Maximum Sound Levels - Refer to Ontario Ministry of Labour Safety Guidelines for Live Performance Industry. https://www.labour.gov.on.ca/english/hs/topics/performance.php Recording No video and/or audio recording is permitted without prior approval from CT. Additional IATSE fees may apply. For full details on reproduction and broadcasting, please consult the General Terms and Conditions. Occupational Health & Safety Safety footwear and hard hats as required in accordance with Ontario Ministry of Labour (MOL) regulations. Working at heights in accordance with MOL regulations. Genie Lift cannot be moved while platform is elevated in accordance with defined operating procedures. Fire Curtain will automatically deploy if the need arises, its travel cannot be blocked under any circumstances. Updated: Feb 2018 Page 1 of 10

STAGE see attached stage plan Stage Surface Masonite painted black over plywood sprung floor. Anchoring (screwing) into the floor is not permitted. Dimensions Proscenium Opening Width: Height: Ideal Playing Area Width: Depth (Setline to backdrop): Maximum Floor Area Width: Depth (apron to back wall): 13.6 m (44-8 ) 7.9 m (26-0 ) 12.0 m (39-5 ) 9.6 m (31-5 ) 23.0 m (75-6 ) 15.7 m (51-7 ) Centre Line To Stage Right Clear: To Stage Left Clear: Curtain Line To Upstage Wall: To Downstage Apron: Stage to High Transfer Area Door Maximum width: Maximum height: Rigging 10.0 m (33-0 ) 9.9 m (32-6 ) 11.4 m (37-10 ) 4.3 m (13-9 ) 3.4 m (11-1 ) 3.9 m (12-11 ) Grid Height: 15.2 m (50-0 ) Stairs SL & SR to auditorium floor. Auditorium Floor to stage height: 0.80 m (2-6 ) ORCHESTRA PIT Normally set to stage level to extend Apron. No patron seating possible on pit when lowered to auditorium floor level. Access by stage left stairway or upstage right crossover. Safety net used on opening when pit is in lowered position. Dimensions (including apron lift section) Dimensions (apron lift section only) Width (SR-SL): Length (DS-US): 12.0 m (39-5 ) 6.8 m (22-4 ) Width (SR-SL): Length (at Ctr Line): 12.0 m (39-5 ) 2.3 m (7-7 ) Depth Below Stage Floor 3.0 m (9-11 ) Below Auditorium Floor 2.2 m (7-3 ) Accommodated Musicians: ~ 30 Accommodated Musicians: ~ 12 MASKING House Curtain (Main) Permanent on line set 2 1 Bermuda Blue Velour, 50% fullness Travel or guillotine 18.3 m wide x 8.5 m high (60-0 x 27-10 ) Manual Control located SR Valance Permanent on line set 1 1 Bermuda Blue Velour Stock trim 5.7 m (18-9 ) 18.3 m wide x 3.0 m high (60-0 x 10-0 ) Mid-Stage Traveler - Permanent on line set 20 1 Black Velour, 50% fullness Travel or guillotine 18.3 m wide x 8.4 m high (60-0 x 27-6 ) Manual Control located SR Borders - Black Velour, 0% fullness 6 18.3 m wide x 2.9 m high (60-0 x 9-6 ) Legs - Black Velour, 0% fullness 4 2.4 m wide x 8.4 m high (8-0 x 27-6 ) 6 3.6 m wide x 8.4 m high (12-0 x 27-6 ) 4 5.2 m wide x 8.4 m high (17-0 x 27-6 ) Cyclorama Permanent on line set 45 1 Cream PVC 18.3 m wide x 8.5 m high (60-0 x 27-10 ) Back Drop - Black Velour 4 5.2 m wide x 8.4 m high (17-0 x 27-6 ) Scrim 1 Black shark tooth scrim, 56 w x 23 h Updated: Feb 2018 Page 2 of 10

RIGGING see http://centrepointetheatre.com/en/rentals/rentals_and_tech/index.htm for line set schedule Single Purchase Counterweight Fly System 37 line sets. (11 have permanent use) Operated from stage right at deck level. Maximum pipe out trim: 14.8 m (48-7 ) Capacities Length of Pipes: Pipe Type: Arbour Capacity: 18.3 m (60-0 ) Schedule 40-1.5 (1.9 OD) 590 kg (1300 lbs) Any production rigging required from high steel must be advanced with CT Production Services. No rigging from gridiron permitted. NOTE: There are no rigging points downstage of the proscenium wall. AUDIO additional charges apply for some items Tour mix position at back of orchestra level, house right. 76 from Proscenium wall. House table to bridge seat kills in Row U,V,W Seats 6,8,10,12,14,16. 150 minimum snake run from SL. Tour consoles patched directly to system processor. Left, Right, Centre & Aux Sub inputs available. House mix position: Installed in centre, at front of balcony FOH PA Left & Right Flown per side 3 Meyer 900-LFC subs (top of array) 8 Meyer Leopard Line array 1 Meyer UPM-1P (down-fill) Front Fill 4 Meyer UP-4XP Monitors 12 EAW MW12 MicroWedge 2 EAW SM200iH 4 Crown itech 5000HD Amp (4 mixes) 1 EV Sb760 Subwoofer 2 Meyer 650-R2 (Sidefill) 2 Meyer CQ-1 (Sidefill) Monitor Console & Processing 1 Midas H3000 56 (44 mono + 4 stereo) 5 Klark DN370 Dual graphic equalizer 1 Klark Square One Dynamics 1 TC M-One XL 12 Crown itech 5000HD Amplifiers FOH Console, Processing & Playback Front of Balcony 1 Midas H3000 56 (40 mono + 8 stereo) 1 Yamaha SPX990 1 TC Electronic M3000 1 TC Electronic M-One XL 1 TC Electronic D2 delay 1 Klark DN514 Quad Gate 1 Klark DN500 Stereo Comp/Limiter/Expander 2 Klark DN504 Quad Compressor 1 Klark DN370 Dual graphic equalizer (L & R O/P) 3 Ashly GQX-3102 stereo graphic equalizer 2 Denon DN-C620 Single Pro CD Player 1 Denon DN-M2300R Dual Minidisk Player FOH Console, Processing & Playback Control Booth 1 Yamaha LS9-32 Digital Mixer 2 JBL 4406 monitors powered by Bryston 2B 1 Stanton C.502 Dual CD/MP3 Player Patching All house patch points terminate to ADC longframe patchbays in Control Booth. All points can patch to Booth LS9 or FOH Midas console. Installed FOH mix position in balcony. House monitor system - available for rental. Updated: Feb 2018 Page 3 of 10

Microphones and DIs 9 Shure SM58 6 Shure SM57 4 Shure BETA 87A 1 Shure BETA 91 1 Shure Beta 52A 2 Shure KSM32/CG 3 AKG 414 1 AKG D112 1 EV RE20 2 Beyer M160 2 Neumann KMS 105 5 Neumann KM-84i 3 Neumann KM184 2 Sennheiser e609s 3 Sennheiser e904 with drum clip 2 Sennheiser 504D with drum clip 4 Sennheiser MD421 2 Sennheiser MD441 4 Crown PCC 160 2 Apex 175 Shotgun 1 Shure SM99 Podium mic 4 BSS AR116 Active DI box 2 BSS AR-133 Active DI box 2 Radial J48 Active DI box 8 Radial JDI Passive DI box 1 Whirlwind PCDI DI box Wireless 2 Shure UHF-R UR4D Dual Receiver (H4 Band 518-578 MHz) 4 Shure UR2/SM58 wireless handheld mics 2 Shure UR1 wireless body pack transmitters with Shure WL184 lav mic or instrument cable. 2 Shure UA874WB antennas Stands 11 Atlas MS-20 with boom 13 Atlas MS-12CE with boom 2 Atlas MS25 with boom 8 Atlas TS-8 Short stands with boom 3 6 Table Top Stand Intercom System WIRELESS 1 Clearcom Freespeak II 1.9 GHz with 4 wireless belt packs WIRED 1 Clearcom MS702 base station (2 channel) 1 Clearcom PM120A SM station (in booth) 3 Clearcom RS-601 belt packs (1 channel) 4 HME WL742 Speaker stations (2 channel) 12 Clearcom CC-95 headsets (single muff) Assistive Listening System Brahler MSI-8d IR Transmitter with IR Radiator TOUR PRODUCTION POWER SOURCES on stage Lighting Audio Video/Motors LOCATION: Mid-stage left SL Proscenium Wall SR Proscenium Wall CAPACITY: 400 Amp 200 Amp or 100 Amp 60 Amp PHASES: 3Ø 3Ø 3Ø VOLTAGE: ALL 120/208 volt, 60 Hz, 5 wire CONNECTORS: Cam-Loc E1016 Female (no reversals on neutral or ground) TOUR PRODUCTION POWER SOURCES in Loading Dock LOCATION: Loading Dock A wall Shore Power Dock A Shore Power Dock B CAPACITY: 400 Amp 50 Amp 50 Amp PHASES: 3Ø 2Ø 2Ø VOLTAGE: 120/208 volt, 60 Hz 120/240 volt, 60 Hz 120/240 volt, 60 Hz CONNECTORS: Cam-Loc E1016 Female 14-50R 14-50R Updated: Feb 2018 Page 4 of 10

LIGHTING see http://centrepointetheatre.com/en/rentals/rentals_and_tech/index.htm for Rep LX plot The Mainstage is equipped with a pre-hung and coloured house lighting plot. The house lighting plot must be restored at the production s expense if any changes are made. Booms Console 8 Custom booms 3.35 m (11 ) 1 ETC GIO (2048 outputs, eos ver 2.6.2) Floor Bases with 2 x 20 Fader Wings 8 Black wooden floor bases and wireless NET3RFR remote Hazer Dimmers 2 Ultratec Radiance Hazer with fan 4 ETC Sensor3 96 channel racks Fogger All wired dimmer per circuit (2.4kW) 2 Martin Jem ZR44 Circuits Followspots 354 20A Twistlock (NEMA L5-20) 2 Strong Super Trooper II 2 kw XBO Control Protocol : (installed at back of balcony HL & HR) ETC sacn/edmx Network Mirror Ball Additional Gateways available. 1 20 mirror ball with 1 RPM motor Fixture Inventory Type Total Inventory Used in Stock Plot Available ETC Source Four - 10 (HPL750) 4 4 0 ETC Source Four - 19 (HPL750) 36 36 0 ETC Source Four - 26 (HPL750) 6 2 4 ETC Source Four - 50 (HPL750) 9 8 1 ETC Source Four - 15-30 Zoom 10 10 0 Colortran 10 (FEL) 18 14 4 Colortran 20 (FEL) 20 4 16 Colortran 30 (FEL) 26 20 6 Colortran Zoom-Ellipse (FEL) 4 4 0 Altman 6x9 (EHG750) 20 4 16 ETC Fresnel (HPL750) 12 12 0 Colortran 1k Fresnel (BTR) 28 24 4 Strand 2K Fresnel (BVW) 12 12 0 Colortran Far Cyc - 3 CELL (FDB) 7 7 0 PAR 64 70 34 36 Martin MAC700 Profile 4 4 0 286 199 87 For Focus: Genie PLI-24 Personnel Lift 24 (AC Powered) NOTE: OH&S requires that lift platform must be lowered before moving. Updated: Feb 2018 Page 5 of 10

VIDEO no projector available Projection Screen 1 Draper Cinefold 4.88 m x 3.05 m (16-0 x 10-0 ) with Fast Fold flyable truss frame. Rear projection surface Miscellaneous Equipment Some of the following equipment is shared between Centrepointe Mainstage and the Studio Theatre. Please inquire about availability with Production Services during show advance. Pianos (A=440, mandatory tuning required) Risers 9 Yamaha CFIII Concert Grand Piano Black plywood lids on folding bases 6 Yamaha GS6 Grand Piano 5 1.2m x 2.4m x 0.15m (4 x 8 x 6 ) Orchestra 2 1.2m x 2.4m x 0.41m (4 x 8 x 16 ) 73 Black Orchestra Chairs (padded, no arms) 5 1.2m x 2.4m x 0.46m (4 x 8 x 18 ) 46 Black Music Stands 5 1.2m x 2.4m x 0.76m (4 x 8 x 30 ) 41 Music Stand Lights Dance Floor 1 Conductor Podium 0.9m x 0.9m (3 x3 ) Rosco Reversible Black / Gray Audio Equipment 5 Rolls 1.6 m (5¼ ) x 12 m (40 ) 1 Whirlwind PressPower2 Media Box 3 Yamaha MS202II Monitor Speakers 60 Black Masonite 1.2m x 2.4m (4 x 8 ) sheet 2 QSC K8 Powered Speakers Other Furniture Lectern (Podium) 4 Stools ~ 29 high 2 Wood Lectern 3 Black Tables 6 x 2-6 Pipe & Drape kit 2 Black Tables 6 x 1-6 BACKSTAGE floor plans available upon request Greenroom one floor up from stage level Sofa, Chairs and Tables Catering Kitchen one floor up from stage level (additional deposit required) Stove top, Ovens, Coffee maker, Microwave, Fridge, Dishwasher Dressing Rooms stage left hallway 2 Private dressing rooms with dressing tables, mirrors, clothing racks, shower, toilet and sink. 4 Large dressing rooms with dressing tables, mirrors, clothing racks. Shared showers, toilets and sinks. Wardrobe Room end of dressing room hallway One high efficiency (HE) washing machine and one dryer. Ironing boards and steamer available. Loading Docks 2 Indoor truck level docks. Can accommodate vehicles up to 22.8m (75 ) in length. 50A shore power. 14 m (46 ) push to Stage Left. All shows must load-in through the LOADING DOCK. Interior Loading Doors: Max. Height 2.7 m (8 10 ) Max. Width 2.4 m (7 10 ) Parking There is free parking in the main lot of Ben Franklin Place. Parking is not permitted along the loading dock access ramp. Dock access must remain clear. Updated: Feb 2018 Page 6 of 10

PATH TO OC TRANSPO BASELINE STATION PUBLIC ENTRANCE CENTREPOINTE STUDIO CATERING KITCHEN DELIVERY ZONE STAGE DOOR B A LOADING DOCK RAMP 8.5% SLOPE HYDRO SUBSTATION POND BEN FRANKLIN PLACE CENTREPOINTE MAINSTAGE INDOOR LOADING DOCKS A & B CENTREPOINTE DRIVE PUBLIC ENTRANCE BEN FRANKLIN PLACE CHAMBER PUBLIC ENTRANCE OTTAWA PUBLIC LIBRARY CENTREPOINTE BOX OFFICE MAIN PUBLIC ENTRANCE Ben Franklin Place - 101 Centrepointe Drive Ottawa, ON K2G 5K7 613-580-2703 - Production/Stage Door Google Map Link: http://g.co/maps/km5vn ALL CAST AND CREW TO ENTER BY STAGE DOOR ENTRANCE