PicoScope 2203, 2204, 2205 PC Oscilloscopes

Similar documents
PicoScope 2000 Series PC Oscilloscopes

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.

PicoScope 4000 Series PC Oscilloscopes

PicoScope 3000 Series Automotive User guide

PicoScope 4000 Automotive PC Oscilloscopes

PicoScope 3000 Series PC Oscilloscopes

PicoScope 4000 Series PC Oscilloscopes

PicoScope 6407 Digitizer

PicoScope 6407 Digitizer

PicoScope 5000D Series

User s Guide OMEGASCOPE OMSP-2000 SERIES. PC Oscilloscopes

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

Operating Instructions

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

PicoScope 3000 Series PC Oscilloscopes

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

PicoScope 2104 & 2105

What to look for when choosing an oscilloscope

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

PicoScope 3000 series

USB Smart Power Sensor

ATS MS/s 8-Bit PCI Digitizer

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

PicoScope 3000 Series

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

PicoScope 2000 Series 2-CHANNEL OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

USB Smart Power Sensor

PicoScope 3000 Series PC Oscilloscopes

PicoScope. User guide. Copyright 2005 Pico Technology Limited. All rights reserved. PSW044 v1.5

R&S RT-Zxx High-Bandwidth Probes Specifications

Choosing an Oscilloscope

PicoScope 3000 Series

PicoScope 3000 Series HIGH-PERFORMANCE 4-CHANNEL OSCILLOSCOPES

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

Portable Performance for Debug and Validation

3000 Series. PicoScope. USB oscilloscopes

PicoScope 3000 Series USB OSCILLOSCOPES AND MIXED-SIGNAL OSCILLOSCOPES. 2 AnAlog ChAnnels serial DeCoDIng MATh ChAnnels

ScopeMeter 190 Series Specifications

Tablet Oscilloscope Quick Guide

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

R&S ZVA110 Vector Network Analyzer Specifications

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Synthesized Clock Generator

R&S RT-Zxx High-Voltage and Current Probes Specifications

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Expect to Make Waves.

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

USB Smart Power Sensor

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

SignalTap Plus System Analyzer

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

Ethernet over Coax EOC110K EOC110R. Instruction Manual. Ethernet over Coax Adapter Kit. Ethernet over Coax Receiver

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Instructions. P MHz 1X/10X Passive Probe

Full-featured CW Microwave Counters for Field, Factory or Lab

2016 RIGOL TECHNOLOGIES, INC.

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

NI PXI/PXIe-2543 Specifications

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Digital Storage Oscilloscopes 2550 Series

instruction manual model 315 video sync separator s/n

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

20 GHz bandwidth 17.5 ps rise time

R&S ZN-Z154 Calibration Unit Specifications

SuperSpeed USB 3.0 to HDMI Audio Video Adapter for Windows & Mac up to 2048x1152 / 1920x1200

Fluke 190-Series II Firmware Upgrade V11.44

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

R&S ZN-Z85 Switch Matrix Specifications

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

2 MHz Lock-In Amplifier

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

ASP-FIBRS1 User Manual

Microwave Counter, Power Meter and DVM in One Portable Package

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

FOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents

100 MHz, 100 MS/s, 14-Bit Digitizer

KHT 1000C HV-Probe Calibrator. Instruction Manual

USB-0100TX USB Fast Ethernet Converter. User s Guide

PicoScope CHANNELS 12 BIT RESOLUTION. HIGH-PRECISION PC OSCILLOSCOPE 256 MS BUFFER MEMORY LOW COST PORTABLE

3G/HD/SD-SDI to HDMI Converter

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

4 x 1 S-Video Switch with Audio and Serial Control

USB-TG124A Tracking Generator User Manual

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Transcription:

PicoScope 2203, 2204, 2205 PC Oscilloscopes User's Guide ps2203.en-1

Contents I Contents 1 Welcome...1 2 Introduction...2...2 1 Using this guide...2 2 Safety symbols...3 3 Safety warning...4 4 FCC notice...4 5 CE notice...5 6 Software licence conditions...6 7 Trademarks...6 8 Warranty...6 9 Company details 3 Product information...7...7 1 What do I get?...7 2 System requirements...8 3 Installation instructions...9 4 Connections...9 1 Connector diagrams...10 2 Signal inputs...10 3 Signal Out connector...10 4 USB port...11 5 Specifications 4 Glossary...12 Index...15 ps2203.en

Welcome 1 1 Welcome Thank you for buying a Pico Technology product! The PicoScope 2203, 2204 and 2205 PC Oscilloscopes from Pico Technology are compact units designed to replace traditional bench-top oscilloscopes costing many times the price. Here are some of the benefits provided by your new PC Oscilloscope: Portability: Take the unit with you and plug it in to any Windows PC. Performance: Fast sampling from 40 MS/s to 200 MS/s, probe-tip bandwidth from 5 MHz to 25 MHz and fast USB 2.0 interface. See Specifications 11 for the details of each scope model. Flexibility: Use it as an oscilloscope, spectrum analyser, data logger or high-speed data acquisition interface. Programmability: The PicoScope 2000 series API lets you write your own programs in your chosen programming language, to control all the features of the scope. Long-term support: Software upgrades are available to download from our website. You can also call our specialists for technical support. You can continue to use both of these services free of charge for the lifetime of the product. Value for money: Buying a Pico PC Oscilloscope means that you don't have to pay twice for all the features that you already have in your PC. The PicoScope 2000 Series oscilloscope contains the special hardware you need and nothing more. Convenience: The software makes full use of the display, storage, user interface and networking built in to your PC. ps2203.en

2 PicoScope 2203, 2204, 2205 User's Guide 2 Introduction 2.1 Using this guide In this guide you will see symbols like this: 2 This is the cross-reference symbol, and it indicates the number of a page on which you can find more information about a topic. The abbreviation MS/s is used in this guide to mean megasamples per second. 2.2 Safety symbols The following symbols appear on the top of the PicoScope 2203, 2204 and 2205 PC Oscilloscopes. Symbol 1: Warning triangle Symbol 2: Equipotential This symbol indicates that a safety hazard exists on the indicated connections if correct precautions are not taken. Read all safety documentation associated with the product before using it. This symbol indicates that the outer shells of the indicated BNC connectors are all at the same potential (shorted together). You must therefore take necessary precautions to avoid applying a potential across the return connections of the indicated BNC terminals. Such a potential could cause a large current to flow, resulting in damage to the product or the connected equipment, or both. ps2203.en

Introduction 3 2.3 Safety warning We strongly recommend that you read the general safety information below before using your oscilloscope for the first time. Safety protection built in to equipment may cease to function if the equipment is used incorrectly. This could cause damage to your computer, or lead to injury to yourself and others. Maximum input range The PicoScope 2203, 2204 and 2205 PC Oscilloscopes are designed to measure voltages in the range -20 V to +20 V. The Ch A and Ch B inputs are protected to ±100 V. Contact with voltages outside the protection range may cause permanent damage to the unit. Mains voltages These products are not designed for use with mains (line power) voltages. To measure mains, use a differential isolating probe specifically designed for high voltages. Safety grounding The PicoScope 2203, 2204 and 2205 PC Oscilloscopes connect directly to the ground of a computer through the USB cable provided to minimise interference. As with most oscilloscopes, avoid connecting the ground input to any potential other than ground. If in doubt, use a meter to check that there is no significant AC or DC voltage between the ground input of the oscilloscope and the point to which you intend to connect it. Failure to check may cause damage to your computer or injury to yourself and others. The product does not have a protective safety ground. Repairs The oscilloscope contains no user-serviceable parts. Repair or calibration of the oscilloscope requires specialised test equipment and must be performed by Pico Technology. ps2203.en

4 PicoScope 2203, 2204, 2205 User's Guide 2.4 FCC notice This equipment has been tested to meet CFR47 (2006) Part 15 of the FCC limits for Class A equipment. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. The PicoScope 2203, 2204 and 2205 PC Oscilloscopes were successfully tested to the standard. For safety and maintenance information see the safety warning 3. 2.5 CE notice The PicoScope 2203, 2204 and 2205 PC Oscilloscopes meet the intent of the EMC directive 89/336/EEC and have been designed to EN61326-1 (2006) Class A Emissions and Immunity standard. The PicoScope 2203, 2204 and 2205 PC Oscilloscopes also meet the intent of the Low Voltage Directive and have been designed to meet the BS EN 61010-1:2001 IEC 61010-1:2001 (Safety requirements for electrical equipment for measurement, control and laboratory use) standard. ps2203.en

Introduction 5 2.6 Software licence conditions The material contained in this software release is licensed, not sold. Pico Technology grants a licence to the person who installs this software, subject to the conditions listed below. Access The licensee agrees to allow access to this software only to persons who have been informed of these conditions and agree to abide by them. Usage The software in this release is for use only with Pico products or with data collected using Pico products. Copyright Pico Technology claims the copyright of, and retains the rights to, all material (software, documents etc.) contained in this release. You may copy and distribute the entire release in its original state, but must not copy individual items within the release other than for backup purposes. Liability Pico Technology and its agents shall not be liable for any loss, damage or injury, howsoever caused, related to the use of Pico Technology equipment or software, unless excluded by statute. Fitness for purpose Because no two applications are the same, Pico Technology cannot guarantee that its equipment or software is suitable for a given application. It is your responsibility, therefore, to ensure that the product is suitable for your application. Mission-critical applications This software is intended for use on a computer that may be running other software products. For this reason, one of the conditions of the licence is that it excludes usage in mission-critical applications such as life-support systems. ps2203.en

6 PicoScope 2203, 2204, 2205 User's Guide 2.7 Trademarks Windows, Excel and Visual Basic are registered trademarks or trademarks of Microsoft Corporation in the USA and other countries. Delphi is a registered trademark of Borland Software Corporation. Agilent VEE is a registered trademark of Agilent Technologies, Inc. LabView is a registered trademark of National Instruments Corporation. Pico Technology Limited, PicoScope and PicoLog are trademarks of Pico Technology, registered in the United Kingdom and other countries. PicoScope and Pico Technology are registered in the U.S. Patent and Trademark Office. 2.8 Warranty Pico Technology warrants upon delivery, and for a period of 24 months unless otherwise stated from the date of delivery, that the Goods will be free from defects in material and workmanship. Pico Technology shall not be liable for a breach of the warranty if the defect has been caused by fair wear and tear, wilful damage, negligence, abnormal working conditions or failure to follow Pico Technology's spoken or written advice on the storage, installation, commissioning, use or maintenance of the Goods or (if no advice has been given) good trade practice; or if the Customer alters or repairs such Goods without the written consent of Pico Technology. 2.9 Company details Address: Pico Technology James House Colmworth Business Park Eaton Socon ST. NEOTS Cambridgeshire PE19 8YP United Kingdom Phone: +44 (0) 1480 396 395 Fax: +44 (0) 1480 396 296 Email: Technical Support: Sales: Web site: support@picotech.com sales@picotech.com www.picotech.com ps2203.en

Product information 7 3 Product information 3.1 What do I get? Your PicoScope PC Oscilloscope kit contains the following items: Reorder code Quantity Description - 1 PicoScope 2203, 2204 or 2205 PC Oscilloscope MI106 1 USB cable, for connection to the USB 1.1 or USB 2.0 port on your PC DI042 1 Software and Reference CD, with PicoScope and PicoLog software, drivers 12, and example programs. DO115 1 USB Oscilloscope Installation Guide 12 12 3.2 System requirements To ensure that your PicoScope 2000 Series PC Oscilloscope operates correctly, you must have a computer with at least the minimum system requirements to run one of the supported operating systems, as shown in the following table. The performance of the software will increase with more powerful PCs, including those with multi-core processors. Item Operating system Processor Absolute minimum Recommended minimum Recommended full specification Windows XP SP2 or Vista (32-bit versions only) 300 MHz 1 GHz Memory As required 256 MB 512 MB Free disk space by Windows 1 GB 2 GB (Note 1) Ports USB 1.1 compliant port USB 2.0 compliant port Note 1: The PicoScope software does not use all the disk space specified in the table. The free space is required to make Windows run efficiently. ps2203.en

8 PicoScope 2203, 2204, 2205 User's Guide 3.3 Installation instructions IMPORTANT Do not connect your PicoScope 2000 Series PC Oscilloscope to the PC before you have installed the Pico software. If you do, Windows might not recognise the scope device correctly. Procedure Follow the instructions in the Installation Guide included with your product package. Connect your PC Oscilloscope to the PC using the USB cable supplied. Checking the installation Once you have installed the software and connected the PC Oscilloscope to the PC, start the PicoScope 12 software. PicoScope should now display any signal connected to the scope inputs. If a probe is connected to your oscilloscope, you should see a small 50 or 60 hertz noise signal in the oscilloscope window when you touch the probe tip with your finger. Moving your PicoScope PC Oscilloscope to another USB port Windows XP SP2 When you first installed the PicoScope 2000 Series PC Oscilloscope by plugging it into a USB 13 port, Windows associated the Pico driver with that port. If you later move the oscilloscope to a different USB port, Windows will display the "New Hardware Found Wizard" again. When this occurs, just click "Next" in the wizard to repeat the installation. If Windows gives a warning about Windows Logo Testing, click "Continue Anyway". As all the software you need is already installed on your computer, there is no need to insert the Pico Software CD again. Windows Vista The process is automatic. When you move the device from one port to another, Windows displays an "Installing device driver software" message and then a "PicoScope 2000 series PC Oscilloscope" message. The PC Oscilloscope is then ready for use. ps2203.en

Product information 9 3.4 Connections 3.4.1 Connector diagrams Connector diagrams Front panel PicoScope 2203 PicoScope 2204 PicoScope 2205 A. Input channel A 10 B. Input channel B 10 C. Signal generator output 10 D. LED: shows when the oscilloscope is sampling data Rear panel PicoScope 2203 PicoScope 2204 PicoScope 2205 E. USB port 10 ps2203.en

10 PicoScope 2203, 2204, 2205 User's Guide 3.4.2 Signal inputs The PicoScope 2203, 2204 and 2205 PC Oscilloscopes have BNC oscilloscope connectors. The inputs have an impedance of 1 MW, so they are compatible with all standard scope probes including x10 attenuated types. 3.4.3 Signal Out connector The SIGNAL OUT connector on the front panel carries the output of the oscilloscope's built-in signal generator, which can generate a number of built-in waveforms as well as arbitrary waveforms from a user-defined table of data. Instructions for use If you are using the PicoScope 6 program, refer to the PicoScope 6 User's Guide for information on how to configure the signal generator. If you are writing your own software, refer to the PicoScope 2000 Series Programmer's Guide. Signal generator output specifications Refer to the Specifications table 11. 3.4.4 USB port Connect the oscilloscope's USB port to your PC's USB 2.0 port using the USB cable supplied. You can also connect it to a USB 1.1 port, but in this configuration the oscilloscope will not operate at full performance. ps2203.en

Product information 11 3.5 Specifications Variant PicoScope 2203 PicoScope 2204 PicoScope 2205 Number of channels 2 Vertical resolution 13 8 bits Analog bandwidth 12 5 MHz 10 MHz 25 MHz Maximum sampling rate 12 (real time) One channel in use 40 MS/s 100 MS/s 200 MS/s Two channels in use 20 MS/s 50 MS/s 100 MS/s Maximum sampling rate (repetitive signals) 1 GS/s 2 GS/s 4 GS/s Buffer size 12 8,000 samples 8,000 samples 16,000 samples If two channels in use, buffer shared between channels. Timebase Ranges 2 ns/div (ETS) or 50 ns/div (real-time) to 200 s/div Accuracy 100 ppm Sampling jitter 3 ps Inputs Connectors BNC female Input impedance 1 MΩ Input capacitance 20 pf or less Coupling AC or DC, software-controlled Voltage ranges 13 ±50 mv, ±100 mv, ±200 mv, ±500 mv, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V Accuracy 3% Noise 1 LSB on ±1 V range Dynamic range 48 db Overload protection ±100 V on single input Trigger Source Ch A or Ch B Modes Rising edge, falling edge Rising edge, falling edge Rising edge, falling edge, hysteresis, pulse width, interval, dropout, windowed, logic Signal generator output 10 Standard waveforms Sine, square, triangle, ramp (up/down) Arbitrary waveform buffer 4,096 samples DAC clock frequency 2 MHz Maximum signal frequency using 100 khz standard waveforms Output impedance 600 Ω Resolution 8 bits Amplitude ±125 mv to ±2 V with ±1 V offset Operating environment Temperature range 0 C to 45 C (20 C to 30 C for quoted accuracy) Humidity 5% to 80% non-condensing Storage environment Temperature range -20 C to +60 C Humidity 5% to 95% non-condensing PC connection Designed for USB 2.0 Will work with USB 1.1 at reduced performance Power supply 4.60 V to 5.25 V @ 500 ma max. Obtained from USB port Dimensions 100 x 150 x 37 mm (3.9 x 5.9 x 1.5 in) Weight 210 g (7.4 oz) Compliance European EMC and LVD standards 4 FCC Rules Part 15 Class A 4 ps2203.en

12 PicoScope 2203, 2204, 2205 User's Guide 4 Glossary Analog bandwidth The frequency at which the measured signal amplitude is 3 decibels below the true signal amplitude. Block mode A fast data collection mode. The PicoScope software puts the oscilloscope into this mode to achieve the fastest possible sampling rates. The oscilloscope collects data as fast as possible and then stops to transfer the data to the PC. During data transfer to the PC in block mode, the oscilloscope cannot sample data from its inputs. Buffer size The size of the oscilloscope's buffer memory, measured in samples. The buffer allows the oscilloscope to sample data faster than it can transfer it to the computer. Coupling mode To switch from AC coupling to DC coupling, or vice versa, select AC or DC from the control on the PicoScope toolbar. The AC setting filters out very low-frequency components of the input signal, including DC, and is suitable for viewing small AC signals superimposed on a DC or slowly changing offset. In this mode you can measure the peak-to-peak amplitude of an AC signal but not its absolute value. Use the DC setting for measuring the absolute value of a signal. Device Manager Device Manager is a Windows program that displays the current hardware configuration of your computer. On Windows XP or Vista, right-click on 'My Computer,' choose 'Properties', then click the 'Hardware' tab and the 'Device Manager' button. Driver A program that controls a piece of hardware. The driver for the PicoScope 2000 Series PC Oscilloscopes is supplied in the form of a 32-bit Windows DLL, ps2000.dll. This is used by the PicoScope software to control the oscilloscope. ETS Equivalent Time Sampling. Constructs a picture of a repetitive signal by accumulating information over many similar wave cycles. This allows the oscilloscope to create a composite cycle that has more samples, and therefore better time resolution, than a single cycle. ETS cannot be used for one-shot signals. Maximum sampling rate A figure indicating the maximum number of samples the oscilloscope can acquire per second. The higher the sampling rate of the oscilloscope, the more accurate the representation of the high-frequency details in a fast signal. "MS/s" is used in this manual an abbreviation for "millions of samples per second". Oversampling A technique for reducing noise in sampled signals. Measurements are taken more frequently than the requested sample rate, and then merged to produce the required number of samples. If, as is usually the case, the signal contains a small amount of noise, this technique can increase the effective vertical resolution 13 of the oscilloscope. PC Oscilloscope A virtual instrument formed by connecting a PicoScope oscilloscope to a computer running the PicoScope software. PicoLog software An application that accompanies all Pico PC Oscilloscopes, turning your PC into a data logger. PicoScope software A software program that accompanies all Pico PC Oscilloscopes. It turns your PC into an oscilloscope, spectrum analyser, and meter display. ps2203.en

Glossary 13 Signal generator Generates a waveform and outputs it on the BNC socket marked Signal Out. This output can be used to drive a test signal through a BNC cable into an external circuit or into one of the oscilloscope's input channels. The PicoScope software allows the generator to output standard waveforms, such as sine and square waves, or arbitrary waveforms defined by the user. Streaming mode A data collection mode in which the oscilloscope samples data and returns it to the computer in a continuous stream. This mode allows the capture of more data than will fit in the oscilloscope's memory buffer, at sampling rates up to 13.3 million samples per second. The PicoScope program selects this mode for long timebases to enable the capture of very long sets of data. Timebase A timer that controls the speed at which the scope device captures data. At slow timebases this process is visible as PicoScope draws the trace across the scope view from left to right, but at fast timebases PicoScope draws the whole trace in a single operation. The timebase is measured in units of time (such as seconds) per division. There are ten divisions across the scope view, so the total time across the width of the view is ten times the "per division" setting. USB 1.1 Universal Serial Bus (Full Speed). This is a standard port used to connect external devices to PCs. A typical USB 1.1 port supports a data transfer rate of 12 megabits per second, so is much faster than an RS-232 or 'COM' port. USB 2.0 Universal Serial Bus (High Speed). This is a standard port used to connect external devices to PCs. A typical USB 2.0 port supports a data transfer rate 40 times faster than USB 1.1 when used with a USB 2.0 device, but can also be used with USB 1.1 devices. Vertical resolution A value, in bits, indicating the precision with which the oscilloscope converts input voltages to digital values. Oversampling (see above) can improve the effective vertical resolution. Voltage range The range of input voltages that the oscilloscope can measure. For example, a voltage range of ±100 mv means that the oscilloscope can measure voltages between -100 mv and +100 mv. Input voltages outside this range will not be measured correctly, but will not damage the instrument as long as they remain within the protection limits of ±100 V. ps2203.en

Index 15 Index A Accuracy timebase 11 voltage 11 Analog bandwidth 11 Arbitrary waveform generator 10 B Bandwidth (analog) 11 BNC connector 10 Buffers size 11 C Calibration 3 CE notice 4 Company information 6 Compliance 11 Connections 9 Contact details 6 D Dimensions 11 Disk space 7 Dynamic range 11 E EMC Directive 4 F FCC notice 4 G I Grounding 3 Input range, maximum 3, 11 Inputs 11 Installation 8 J L LED 9 Low Voltage Directive 4 M Mains voltages 3 N Noise 11 O Operating environment 11 Operating system 7 Oscilloscope probe 10 Outputs 11 Overload protection 11 P PC connection 11 Pico Technical Support 6 PicoScope 2203 Series 1 PicoScope software 8 Power supply 11 Processor 7 R Repairs 3 Resolution, vertical 11 S Safety symbols 2 warning 3, 4 Sampling rate 11 Scope probe 10 Signal generator 10, 11 output 10 Signal Out connector 10 Software licence conditions 5 Specifications 11 Storage environment 11 System memory 7 System requirements 7 Jitter 11 ps2203.en

16 PicoScope 2203, 2204, 2205 User's Guide T Technical support 6 Test equipment 3 Trademarks 6 Trigger bandwidth 11 U modes 11 source 11 USB 7 changing ports 8 USB port 10 V Vertical resolution 11 Voltage ranges 11 W Warranty 6 Weight 11 Windows, Microsoft 7 ps2203.en

17 ps2203.en

Pico Technology James House Colmworth Business Park Eaton Socon ST. NEOTS Cambridgeshire PE19 8YP United Kingdom Tel: +44 (0) 1480 396 395 Fax: +44 (0) 1480 396 296 Web: www.picotech.com ps2203.en-1 31.1.08

PicoScope 2000 Series PC Oscilloscopes User's Guide PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

I PicoScope 2000 Series User's Guide Table of Contents 1 Introduction...1 1 Overview...1 2 Safety symbols...1 3 Safety warning...2 4 FCC notice 5 CE notice...2...3 6 Licence conditions...3 7 Trademarks 8 Warranty...3...4 9 Company details...4 2 Product information...5 3 Glossary Index 1 Minimum system...5 requirements 2 Installation instructions...5 3 Specifications...7 4 Sampling modes...7...8...10 PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

Introduction 1 1 Introduction 1.1 Overview The PicoScope 2000 series is a range of low-cost, high-performance PC Oscilloscopes, fully USB 2.0 capable and backwards compatible with USB 1.1. There is no need for an additional power supply as power input is from the USB port, so these oscilloscopes are highly portable. With the PicoScope software, you can use PicoScope 2000 series oscilloscopes as PC Oscilloscopes and spectrum analysers; with the PicoLog software, you can use them as data loggers. A PicoScope 2000 PC Oscilloscope is supplied with the following items: USB cable, for use with both types of USB port Software CD Quick start guide Please read the important information in this introductory section and then proceed to the Installation instructions. 1.2 Safety symbols Symbol 1: Warning Triangle This symbol indicates that a safety hazard exists on the indicated connections if correct precautions are not taken. Ensure that you read all safety documentation associated with the product before using it. Symbol 2: Equipotential This symbol indicates that the outer shells of the indicated BNC connectors are all at the same potential (shorted together). You must therefore take necessary precautions to avoid applying a potential across the return connections of the indicated BNC terminals, as this may result in a large current flow causing damage to the product and/or connected equipment. Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

2 PicoScope 2000 Series User's Guide 1.3 Safety warning We strongly recommend that you read the general safety information below before using your oscilloscope for the first time. Safety protection built in to the equipment may cease to function if the equipment is used incorrectly. This could cause damage to your computer, or lead to injury to yourself and others. Maximum input range PicoScope 2000 series PC Oscilloscopes are designed to measure voltages in the range -20 V to +20 V. Any voltages in excess of ±100 V may cause physical damage. Mains voltages Pico Technology products are not designed for use with mains voltages. To measure mains, use a differential isolating probe specifically designed for a high source voltage. Safety grounding PicoScope 2000 Series PC Oscilloscopes connect directly to the ground of a computer through the interconnecting cable provided. This method minimises interference. As with most oscilloscopes, avoid connecting the ground input to any source other than ground. If in doubt, use a meter to check that there is no significant AC or DC voltage between the ground input of the oscilloscope and the point to which you intend to connect it. Failure to check may cause damage to your computer, or lead to injury to yourself and others. You should assume that the product does not have a protective safety earth. Repairs The oscilloscope contains no serviceable parts. Repair or calibration of the oscilloscope requires specialised test equipment and must be performed only by Pico Technology. 1.4 FCC notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. For safety and maintenance information see the safety warning. PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

Introduction 3 1.5 CE notice The PicoScope 2000 series of PC Oscilloscopes meets the intent of the EMC directive 89/336/EEC and has been designed to EN61326-1 (1997) Class B Emissions and Immunity standard. Products from the PicoScope 2000 series also meet the intent of the Low Voltage Directive and have been designed to meet the BS EN 61010-1:2001 IEC 61010-1:2001 (safety requirements for electrical equipment, control, and laboratory use) standard. 1.6 Licence conditions The material contained in this release is licensed, not sold. Pico Technology Limited grants a licence to the person who installs this software, subject to the conditions listed below. Access The licensee agrees to allow access to this software only to persons who have been informed of these conditions and agree to abide by them. Usage The software in this release is for use only with Pico products or with data collected using Pico products. Copyright Pico Technology Limited claims the copyright of, and retains the rights to, all material (software, documents etc.) contained in this release. You may copy and distribute the entire release in its original state, but must not copy individual items within the release other than for backup purposes. Liability Pico Technology and its agents shall not be liable for any loss, damage or injury, howsoever caused, related to the use of Pico Technology equipment or software, unless excluded by statute. Fitness for purpose Because no two applications are the same, Pico Technology cannot guarantee that its equipment or software is suitable for a given application. It is your responsibility, therefore, to ensure that the product is suitable for your application. Mission-critical applications This software is intended for use on a computer that may be running other software products. For this reason, one of the conditions of the licence is that it excludes usage in mission-critical applications; for example, life-support systems. 1.7 Trademarks Windows and Excel are registered trade marks of Microsoft Corporation. Pico Technology Limited and PicoScope are internationally registered trademarks. Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

4 PicoScope 2000 Series User's Guide 1.8 Warranty Pico Technology warrants upon delivery, and for a period of 24 months unless otherwise stated from the date of delivery, that the Goods will be free from defects in material and workmanship. Pico Technology shall not be liable for a breach of the warranty if the defect has been caused by fair wear and tear, wilful damage, negligence, abnormal working conditions or failure to follow Pico Technology's spoken or written advice on the storage, installation, commissioning, use or maintenance of the Goods or (if no advice has been given) good trade practice; or if the Customer alters or repairs such Goods without the written consent of Pico Technology. 1.9 Company details Address: Pico Technology Limited The Mill House Cambridge Street St Neots Cambridgeshire PE19 1QB United Kingdom Phone: +44 (0) 1480 396 395 Fax: +44 (0) 1480 396 296 Email: Technical Support: support@picotech.com Sales: sales@picotech.com Web site: www.picotech.com PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

Product information 5 2 Product information 2.1 Minimum system requirements For PicoScope 2000 series PC Oscilloscopes to operate, a computer with the minimum system requirements to run Windows or the following (whichever is the higher specification) is required: Processor Memory Disk space Operating system Ports Pentium class processor or equivalent minimum. 32 MB minimum. 10 MB minimum. Microsoft Windows 2000, XP, Vista or later. USB 1.1 compliant port minimum. USB 2.0 compliant port recommended. Must be connected direct to the port or a powered USB hub. Will not work on a passive hub. 2.2 Installation instructions Important Do not connect a PicoScope 2000 series PC Oscilloscope to the PC until you have installed the software. Install the software by following the steps in the installation guide supplied with your oscilloscope. Connect your oscilloscope to the PC with the USB cable supplied. There is no need for an additional power supply as power is drawn from the USB port. Checking the installation Once the software has been installed, ensure that the oscilloscope is connected to the PC and start the PicoScope or PicoLog software. The software should now display the voltage that you have connected. If you are using a scope probe and PicoScope, you should see a small 50 Hz or 60 Hz mains signal in the oscilloscope window when you touch the scope probe tip with your finger. Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

6 PicoScope 2000 Series User's Guide Standard oscilloscope connectors PicoScope 2000 Series PC Oscilloscopes have standard oscilloscope connectors. The input impedance is also standard, so the x10 function on scope probes works correctly. Connector diagram 1 USB port connector. 2 LED. When lit, indicates the oscilloscope is sampling data. A Channel A input. B Channel B input. PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

Product information 7 2.3 Specifications Vertical Resolution Analog Bandwidth Maximum Sampling Rate Single-channel Dual-channel Buffer Size Single-channel Dual-channel Inputs Voltage Ranges Accuracy Operating Environment Temperature range Humidity Overload Protection PicoScope 2202 8 bits 2 MHz 20 MS/s 10 MS/s per channel 32 ksamples 16 ksamples per channel 2 channels with BNC sockets 1 MW impedance AC/DC coupling 20 pf input capacitance ± 50 mv to ± 20 V ranges in 9 ranges 3 % (voltage) 100 ppm (time) 0 C to 70 C (20 C to 30 C for quoted accuracy) 25% to 75% RH ± 100 V PC Connection USB 2.0 Compatible with USB 1.1 Power Supply Maximum Dimensions Compliance From USB port: 4.6 to 5.25 V; 500 ma External power supply is not required 140 mm x 190 mm x 45 mm CE standard; FCC standard 2.4 Sampling modes PicoScope 2000 series PC Oscilloscopes can run in various sampling modes. At high sampling rates, the oscilloscope collects data much faster than a PC can read it. To compensate for this, the oscilloscope stores a block of data in an internal memory buffer, delaying transfer to the PC until a preset number of data points has been sampled. This is called block mode. At very low sampling rates, you may want to switch to streaming mode. This allows accurately timed data to be transferred back to the PC in short blocks, without gaps. Real time continuous mode is also provided for use at low sampling rates, when immediate data transfer without gaps is required but timing accuracy is not critical. Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

8 PicoScope 2000 Series User's Guide 3 Glossary AC/DC switch To switch from alternating current to direct current, or vice versa, select AC or DC from the control on the oscilloscope toolbar of the PicoScope software application. The setting should be adjusted to suit the characteristics of the input signal. Analog bandwidth The input frequency at which the signal amplitude has fallen by 3 db from its nominal value. Block mode A sampling mode in which the computer prompts the oscilloscope to collect a block of data into its internal memory before stopping the oscilloscope and transferring the whole block into computer memory. This mode of operation is suitable when the input signal being sampled contains high frequencies. Note: To avoid aliasing effects, the sampling rate must be greater than twice the maximum input frequency. Buffer size The size of the oscilloscope buffer memory. The buffer memory is used by the oscilloscope to store data temporarily. This allows the oscilloscope to sample data independently of the speed at which it can transfer data to the computer. Device Manager Device Manager is a Windows applet that displays the current hardware configuration of your computer. On Windows 2000, XP or Vista, right-click on 'My Computer,' choose the 'Hardware' tab and select 'Device Manager'. Driver A software application that controls a piece of hardware. The driver for the PicoScope 2000 series PC Oscilloscopes is supplied in the form of a 32 bit Windows DLL. This is used by the PicoScope and PicoLog software to control the oscilloscopes. Maximum sampling rate A figure indicating the maximum number of samples the oscilloscope is capable of acquiring per second. Maximum sample rates are usually given in MS/s (megasamples per second) or GS/s (gigasamples per second.) The higher the sampling speed of the oscilloscope, the more accurate the representation of the high-frequency details in a fast signal. PC Oscilloscope An instrument consisting of a PicoScope 2000 series PC Oscilloscope and the PicoScope software application. PicoLog software This is a software product that accompanies all our oscilloscopes. It turns your PC into a data logger and chart recorder. PicoScope 2000 series A PC Oscilloscope range that includes the PicoScope 2202 PC Oscilloscope. PicoScope software This is a software product that accompanies all our oscilloscopes. It turns your PC into an oscilloscope, spectrum analyser, and meter display. PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

Glossary 9 Real time continuous mode A sampling mode in which the software repeatedly requests single samples from the oscilloscope. This mode is suitable for low sampling rates when you require the latest sample to be displayed as soon as it is captured. Streaming mode A sampling mode in which the oscilloscope samples data and returns it to the computer in an unbroken stream. This mode of operation is suitable when the input signal being sampled contains only low frequencies. Timebase The timebase controls the time interval that the width of the scope display represents. If you select Timebase is time per division in the Preferences dialog box in the PicoScope application, it works like a traditional bench top scope. There are ten divisions across the screen, so the total time interval is ten times the timebase. USB 1.1 Universal Serial Bus (Full Speed). This is a standard port that enables you to connect external devices to PCs. A typical USB 1.1 port supports a data transfer rate of 12 Mbps (12 megabits per second), and is much faster than a serial port. USB 2.0 Universal Serial Bus (High Speed). This is a standard port that enables you to connect external devices to PCs. A typical USB 2.0 port supports a data transfer rate that is 40 times faster than that supported by USB 1.1. An additional feature of USB 2.0 is that it is backwards compatible with USB 1.1. Vertical resolution A value, in bits, related to the number of distinct input voltage levels that the oscilloscope can convert to digital values. Calculation techniques can improve the effective resolution. Voltage range The range of input voltages that the oscilloscope will measure in a given mode. Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

10 PicoScope 2000 Series User's Guide Index A Accuracy 7 Analog bandwidth 7 B BNC connector 5 Buffer size 7 C Calibration 2 Contact details 4 D Data logger 1 Dimensions 7 H Humidity 7 I Input range (maximum) 7 Inputs 7 M Maximum input range 2 O Operating environment 7 Oscilloscope probe 5 Overload protection 7 P PC connection 7 PC oscilloscopes 1, 3 PicoLog software 1 PicoScope 2000 series 1, 2, 3, 5 PicoScope software 1, 5 Power supply 7 Probe (oscilloscope) 5 R Repair 2 S Safety symbols 1 Safety warning 2 Sampling rate (maximum) 7 Scope probe 5 Spectrum analyser 1 System requirements 5 T Temperature 7 Test equipment 2 U USB 1, 5 USB 1.1 5 USB 2.0 5 V Vertical resolution 7 Voltage ranges 7 PS2000044-2 Copyright 2005-7 Pico Technology Limited. All rights reserved.

11 Copyright 2005-7 Pico Technology Limited. All rights reserved. PS2000044-2

Pico Technology Ltd The Mill House Cambridge Street St Neots PE19 1QB United Kingdom Tel: +44 (0) 1480 396 395 Fax: +44 (0) 1480 396 296 Web: www.picotech.com PS2000044-2 24.4.07 Copyright 2005-7 Pico Technology Limited. All rights reserved.