WLT. Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y. Water-Level Indicator

Similar documents
Installation Guide OvalSox TM Cable

Dynatel Advanced Cable Locator 2250

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

T10 Float Level Switch

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Instructions. P MHz 1X/10X Passive Probe

LUDLUM MODEL 43-5 ALPHA SCINTILLATOR. March 2011

Colour Explosion Proof Video Camera USER MANUAL VID-C

INSTALLATION INSTRUCTIONS FOR

MICROPLATE LUMINOMETER. Operating Manual. Dated: 3/7/2002 Version: C Part Number:

INTRODUCTION PRODUCT CONCEPT AND DESCRIPTION

FOR MEDIA SAMPLING INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

OPERATIONS MANUAL. ba76140e01 02/2013 CONDUCTIVITY CELL FOR ULTRAPURE WATER

OFI Optical Fiber Identifier User s Guide

Vinmetrica SC-200 User Manual

Signet 2250 Hydrostatic Level Sensor

User Manual. Model 1351 DVI Repeater with HDCP

Calaf integrated stereo amplifier

Expand Your Factory Radio add Satellite Radio Harness Connection

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

minihomer TM User s Guide

VPM2. Operation Manual

Operating Instructions BTX-1 Series Digital Band Tension Meter

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

LUDLUM MODEL ALPHA-BETA SAMPLE COUNTER SERIAL NUMBER PR AND SUCCEEDING SERIAL NUMBERS. February 2016

TR-2 OPERATION MANUAL

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

3 Locating and Marking Products DOCUMENT OBSOLETE

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

Photovoltaic Module Installation Manual (IEC)

Flat-Bed Module Recorders

Dystrybucja i sprzedaż: Meditronik Sp. z o.o Warszawa, ul. Wiertnicza 129, tel. (+48 22) , fax (+48 22)

CABLE TESTER User Manual

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 CUSTOMER SERVICE... 4 PACKAGE CONTENTS... 4 RECOMMENDED TOOLS... 6 CONTROL PANEL OVERVIEW...

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

2x1 HDTV Switcher USER MANUAL.

Instructions. Cable with Armor F CAUTION. October Rev A

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Caution. Hanging the Screen:

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Phono Amplifier brinkmann «EDISON» Manual.

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

ECP1 MC / MM PHONO PREAMPLIFIER OWNERS MANUAL

BISON 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

Photovoltaic Module Installation Manual (IEC)

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

WQ Series Water Quality Bench top Meters

VPM2. Operator's Manual

Operating Instructions DCI-50-CT Cable Identifier

Digital Lighting Systems. DIGTAN4-PRO Converts 4 PROTOCOL channels to 4x 0.5 V to 10 VDC Analog

apple Service Source Apple Studio Display 17" LCD (ADC) Updated 6 Decenber Apple Computer, Inc. All rights reserved.

4x1 HDTV Switcher USER MANUAL.

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

LED-PAR200B USER MANUAL. COLORsplash 200B

Metal Electrode Meter

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

JACK Digital HDTV Over-the-Air Antenna

880B MAGNETIC LOCATOR OPERATIONS MANUAL SERVICE CENTER, SALES AND TECHNICAL SUPPORT INFORMATION

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

SECTION COMMERCIAL DOOR OPERATORS. Display hidden notes to specifier. (Don't know how? Click Here)

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

Sport-TIMER 3000 TM Instruction Manual

2006 MFJ ENTERPRISES, INC.

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Lawnbott No Signal /Blackout Troubleshooting Guide

Orbit TM DIGITAL SHAKERS

READ ME FIRST. Touchstone TV Lift

Electronic lubrication control unit

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

SPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4)

RQflex 10. Manual English

VITALink Taped Splice Straight Through Crimp

HPA-8 8 Channel Headphone Amplifier. Owner s Manual

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

MOTOR LEAD TO DOWN HOLE CABLE SPLICE PROCEDURE

2009 MFJ ENTERPRISES, INC.

Ford AMS Test Bench Operating Instructions

Model KT 53 Cooling incubators with thermoelectric cooling

HDTV CAT-5 Extender USER MANUAL.

TO THE INSTALLER: BE SURE TO LEAVE THIS MANUAL WITH THE OWNER.

Operating Instructions ACX-Series Digital Aircraft Cable Tension Meter

ASP-FIBRS1 User Manual

Reference 150 LINEAR

Operating Instructions DCI-50-CT Cable Identifier

Modular Lube Lubrication Systems System Controls

Light Source. Specification & User Manual

makes your fingers dance! A handy instrument with an enormous sound.

TROUBLESHOOTING GUIDE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

The Quality Connection. Internal wiring for electrical equipment Electrical Appliance Assemblies

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Transcription:

WLT Water-Level Indicator Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y

CONTENTS Operating Instructions... pg. 3 Special Instructions... pg. 4 Hard (Mineralized) Water... pg. 4 Oil Contamination... pg. 4 Short-Curcuited Cable or Electrode... pg. 4 Custom Specifications... pg. 4 Serial Number... pg. 5 Parts List... pg. 5 Specifications... pg. 6 2

OPERATING INSTRUCTIONS 1. Check the condition of the battery by flipping the toggle switch to the Batt Test position. If the battery has a charge, the red LED will light and an audible beep will be heard. If the battery is weak, the light will be dim and the beep will be weak. Replace the standard 9-volt transistor battery by removing the two black knobs that hold the control panel in place and lifting out the module. After replacing the battery, carefully fit the module back in place and replace the black knobs, finger tight. 2. To familiarize yourself with the action of the unit, dip the electrode into a jar of water. When the electrode touches the water, the LED will light and a beep will be heard. 3. Make sure the toggle switch is in the ON position. Slowly lower the electrode cable into the well, keeping an eye on the cable markers, which are spaced every 5 feet. Every other cable marker - at 10, 20, 30, etc. feet - is marked with a number: No. 1 marks 10 feet, No. 2 marks 20 feet, No. 3 marks 30 feet, etc. 4. When the LED lights and the beep is heard, the electrode has reached the water. Check the position of the nearest cable marker to calculate the water level. For draw-down tests, initially lower the electrode unit when the well is not pumping. This will help keep the cable and electrode assembly from getting tangled around the pump column. 5. Turn off the instrument when not in use to conserve the battery. 6. When the job is completed, wash the electrode assembly with fresh water and dry it thoroughly. 7. If your Fisher WLT is cared for in the manner due any fine piece of equipment, you will be assured long and dependable service. 3

SPECIAL INSTRUCTIONS Hard (Mineralized) Water When using the unit in areas of hard water, the LED and audio beep may continue to respond after the electrode is withdrawn from the water. In this case, it will be necessary to completely rewind the WLT to dry or blow out the electrode before taking a second reading. Oil Contamination Lubricated parts of the pump and pump motor occasionally leak, causing a layer of oil to float above the water level. This oil will foul the electrode assembly unless special precautions are taken. If oil is suspected, place one of the small bags (probe covers) that accompany the instrument over the electrode assembly, and fasten it securely. Wet the bag and then proceed, following the instructions given above. Wetting the bag will help it pass through the oil with a minimum of contamination. The texture of the bag allows water but prevents oil from readily passing through. An accurate reading of the water level can be obtained by slowly withdrawing the electrode assembly once it is definitely below the water level. The audible beep and LED will indicate when the electrode has passed the oil-water contact. If the electrode becomes contaminated with oil, it should be washed with dish detergent and thoroughly rinsed. Short-Circuited Cable or Electrode Cable damage or hard-water residue on the electrode assembly may short out the instrument, resulting in a lighted LED and an audible beep when the instrument is turned on. Locate and repair any shorts in the cable, and shake or blow out all residue from the electrode assembly before using the instrument. Any short, if left unrepaired, will cause battery drain when the instrument is left on. Custom Specifications The WLT series cable comes in standard lengths of 100, 200, 300, 400 and 500 feet, with crimped brass markers every five feet and a flexible brass electrode. Metric lengths of 50, 100 and 150 meters are also available with brass markers at one-meter intervals. 4

For special applications, Fisher Research Laboratory will custom manufacture any cable length up to 500 feet, marked in feet or meters. Serial Number The serial number of each WLT unit is located inside the cable spool. To access the serial number, remove the two black knobs that hold the control panel in place. Carefully remove the control module, revealing the serial number on the inside of the spool. PARTS LIST Part # Description Replacement Cable: 201577-3240 300 Ft. Tagged and w/brass Electrode 201577-3260 500 Ft. Tagged and w/brass Electrode Replacement Cable (Metric): 202973-3310 100 M. Tagged and w/brass Electrode 202973-3320 150 M. Tagged and w/brass Electrode Miscellaneous: 673051 Probe Cover (T-Bag) 150884 9-Volt Battery 201577 Brass Electrode Assembly (w/36 of cable) 943061 Brass Markers (Specify Blank or Numbered) 5

SPECIFICATIONS Accuracy... Guaranteed accuracy is ±0.4% from probe tip to any marker. Operating Temp...32 O F to 120 O F, (0 O C to 50 O C) Battery...(1) 9V (NEDA 1604) Weight: WLT (w/300 cable)... 1 lbs. (5k) Shipping Weight: WLT 300 cable... 3 lbs. (5.9k) WLT 300 cable w/hard case... 18 lbs. (8.2k) Shipping Size: WLT (all models):...17 X 14-3/4 X 8...(43cm X 37cm X 20cm) WLT in hard case:...9-1/2 X 16-3/4 X 8-3/4...(49cm X 42cm X 22cm) 6

7

Q U A L I T Y Fisher detectors are renowned for their quality. Each detector is hand crafted in the USA with pride P E R F O R M A N C E The worldwide underground utility industry relys on Fisher. Our instruments are durable, dependable, and locate deeper. R E P U T A T I O N Fisher produced the first patented metal detector in 1931. For over 70 years, the Fisher logo has been a mark of excellence. 2 - YEAR LIMITED WARRANTY Fisher believes in the products we produce and backs this belief with a 2 year limited warranty. Proof of purchase is required to make a claim under this warranty. NOTE TO FOREIGN COUNTRY CUSTOMERS This warranty may vary in other countries, check with your distributor for details. Factory warranty follows the channel of distribution. Warranty does not cover shipping costs. S E R V I C E Fisher is committed to providing you, our valued customer, with superior service. Each and every instrument is rigidly tested and carefully inspected during assembly and before shipment. Should you have any questions or problems, contact: FISHER RESEARCH LABORATORY 1465-H Henry Brennan, El Paso, Texas 79936 Tel 915.225.0333 Fax 915.225.0336 www.fisherlab.com email:info@fisherlab.com FRL#870419 070609