PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

AS09..S 3-pole Contactors - Spring Terminals

02/11/2015

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Datasheet - SRB301LC 24VAC/DC

Series CT7N Bimetallic Overload Relays

Model Number Structure

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Bimetal Temperature Switch

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Ordering details. Approval. Classification

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Type: DILM12 10(24VDC) Article No.:

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Minicontactorrelay,2NO/2NC,DCoperated

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LED control gear Compact fixed output

Type: DILM25 10(24V50HZ) Article No.:

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LED Driver Compact dimming

Magnecraft Power Relays

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

EMC Solutions Noise filtering

Technical Information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Level Measurement silometer FMC 420, FMC 423

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Power Circuit of a UL508A Panel. Typical UL489 Application

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Linear flow controls VFC Linear flow controls with actuator IFC

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Single Point Flow Monitor SW118 SW119

Capacitance Limit Detection nivotester FTC 420/421/422

Process transmitter RMA422

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Bulletin 190 IEC Modular Starter System

LED Driver Linear / area fixed output

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Datasheet - SRB-E-201ST

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

LED Driver Compact fixed output

GV2ME. Main. Device short name. Device application

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Magnetic and Hydraulic-Magnetic Circuit Breaker

LED Driver Compact fixed output

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Operating instructions Electronic preset counter Type series 717

Linear flow control with actuator IFC

VAT 20 Adjustable Frequency Drive

GV2ME. Main. Device short name. Device application

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys circuit-breakers

GR circuit breaker - hydraulic magnetic, Datasheet

MILLITARY SPECIFICATION SHEET

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Standard signal metering in wall-mounting case

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Data Sheet Definite Purpose Contactors Ex9CK Series

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Electrical connection

Modular pulse operated latching relay 16 A

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data


Process Transmitter RMA 422

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LONWORKS Fibre Optic Converter

MULTIS L72. Operating instructions

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

GV2P05. Main. Device short name. Device application

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Clamp 200 A AC/DC (+ V AC/DC + Ω)

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Transcription:

Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in the K H. Kuhnke Ltd nit 6 Focus 303 Focus Way, Walworth Business Park Andover Hampshire SP10 5NY nited Kingdom Tel: +44 (0)1264 364194 Fax: +44 (0)1264 365991 Email: sales@kuhnke.co.uk Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

1510 VDE0435,0110Gr.C 9 Single-phase Voltage Monitoring Relay Standard type Operating range -25 C to +70 C DC and AC undervoltage measuring VDE0435,0110Gr.C 1510 9 Order Code Order code. 2 10-100 mv 230 VAC 50 / 60 Hz Voltage monitoring relay Monitored variable 1510 single-phaseundervoltage 1510. 2 C/O 2 Monitored voltage range 10-100 mv 10-100 mv 50-500 mv 50-500 mv 0.5-5 V 0.5-5 V 5-50 V 5-50 V 25-250 V 25-250 V 50-500 V 50-500 V Supply voltage 24 VAC 24 VAC 110 / 115 VAC 110 / 115 VAC 230 VAC 230 VAC 240 VAC 240 VAC 24 VDC * 24 VDC (no frequency stated) Frequency (at AC only) 50 / 60 Hz 50 / 60 Hz * See page 65 for series resistors for the 24 VDC device (for supply voltages above 24 VDC) Contact Data Type of contact Contact material Nominal contact current Inrush current Max. switching capacity Nominal contact voltage 2 C/O Single contact AgCdO 5 A 5 A 1100 VA 250 VAC Kuhnke 63 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Dimensions, Connection Diagram(s) 72 A1 A2 (+) (-) (-)~ - B1 B2 < 11 21 105.5 45 A2 General Data Display Insulation group VDE 0110b/2.79 Test voltage Auxiliary circuit - output circuit - monitoring circuit Vibration resistance 1 green LED lights if the output relay is pulled up C250 2500 VAC 4 g at 25-100 Hz (in accordance with GL) Terminals Tension relief terminal with head screws metric M 2.6 Terminal torque Terminal capacity max. 0.6 Nm solid conductor 2 x 1.5 mm 2 flexible conductor with ferrule 2 x 1.5 mm 2 Operating temperature -25 C to +70 C Storage temperature -25 C to +85 C Protection in accordance with DIN 40050 IP40 Housing IP20 Screws IP10 Clamps Mounting Rail in accordance with EN50022-35 x 7.5/15 Screw mounting with mounting plate Weight approx. 300 g Auxiliary Circuit Nominal line voltages Nominal line frequency Voltage ranges see order code 50 / 60 Hz if AC devices AC = ± 20 % at 100 % ED +50 % for 10 s 10 % ED DC = 24 VDC +25 %/-10 % Rated power 2.0 VA cos ϕ 0.7 Kuhnke 64 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Monitoring Circuit Pull-in voltage an adjustable acc. to the upper scale Input resistance in kω Continuous overload in V Overload duration 10 s 10-100 mv 2 30 50 V 50-500 mv 20 100 140 V 0.5-5 V 82.5 200 280 V 5-50 V 511 500 700 V 25-250 V 1000 750 1000 V 50-500 V 1000 750 1000 V Adjustment error 4 % Drop-out voltage ab Temperature dependence Permanently adustable between 0.5 and 0.99 x an acc. to the lower scale. 0.01 %/K Variance of switching points under identical conditions 0.5 % Monitored value The arithmetic mean value is measured. The scales are adjusted to sinusoidal AC voltage. If just DC voltages without any harmonic contents are measured, the desired switching point should be multiplied by 0.89 and the result set on the scale. Series Resistance for the 24 VDC Device Supply voltage v in VDC 48 VDC 60 VDC 110 VDC 220 VDC Series resistance R v in Ω 470 750 1800 3900 Power rating P of R v in W 1.23 1.7 4.1 9.8 Max. power P of R v in W 1.92 2.7 6.4 15.4 Kuhnke 65 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Three-phase Voltage Monitoring Relay D1515 / D1525 / D1535 Standard type Operating range -25 C to +70 C Monitoring of three-phase systems VDE0435,0110Gr.C 1510 9 Order Code Order code D 1525. 2 230 / 240 V 50 Hz Three-phase voltage D Monitored variable 1515 Three-phase undervoltage 1515. 1525 Asymmetric three-phase angle 1525. 1535 Three-phase sequence 1535. 2 C/O 2 Measuring and supply voltage (Voltage: Phase - N / Phase - Phase) D 57 / 100 V 57 / 100 V 110 / 190 V 110 / 190 V 127 / 220 V 127 / 220 V 230 / 400 V 230 / 400 V 240 / 415 V 240 / 415 V 290 / 500 V 290 / 500 V Frequency 50 / 60 Hz 50 / 60 Hz 50 Hz (for D 1525 only) 50 Hz Contact Data Type of contact Contact material Nominal contact current Inrush current Max. switching capacity Nominal contact voltage D1515 / D1525 / D1535 2 C/O Single contact AgCdO 5 A 5 A 1100 VA 250 VAC Kuhnke 66 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Dimensions, Connection Diagram(s) 72 105.5 45 L1 L2 L3 11 21 L1 L2 L3 11 21 L1 L2L1 ~ - N L2 L3 < s 11 21 L1 L2 ~ - L3 L1 L2 < 11 21 N N D1515 / D1525 D1535 General Data Display Insulation group VDE 0110b/2.79 Test voltage Monitoring circuit - output circuit Vibration resistance D1515 / D1525 / D1535 1 green LED lights if the output relay is pulled up C250 2500 VAC 4 g at 25-100 Hz (in accordance with GL) Terminals Tension relief terminal with head screws metric M 2.6 Terminal torque Terminal capacity max. 0.6 Nm solid conductor 2 x 1.5 mm 2 flexible conductor with ferrule 2 x 1.5 mm 2 Operating temperature -25 C to +70 C Storage temperature -25 C to +85 C Protection in accordance with DIN 40050 IP40 Housing IP20 Screws IP10 Clamps Mounting Rail in accordance with EN50022-35 x 7.5/15 Screw mounting with mounting plate Weight approx. 300 g Auxiliary Circuit The supply input is internal connected to the monitoring input (L1 and L2). Kuhnke 67 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Monitoring Circuit Nominal line voltages D1515 D1525 D1535 see order code Nominal line frequency 50 / 60 Hz 50 Hz ±0.5 % 50 / 60 Hz Overload rating 1.2 x N continuous 1.5 x N 10 s at 10 % ED Rated power 2.4 VA cos ϕ 0.7 Monitored value Voltage reading Phase angle Phase sequence Drop-out voltage Adjustment error Pull-in voltage Adjustment error ab permanently adjustable between 0.7 and 1.0 x N acc. to the upper scale 1% an permanently adjustable between 1.02 and 1.2 x ab acc. to the lower scale 2.5% Variance of switching points at the three phases 1 % AS permanently adjustable between 3 and 30 asymmetry of angles 2.5 % fixed setting at 1 % approx. Temperature dependence 0.01 %/K 0.01 %/K Variance of switching points under identical conditions 0.5 % 0.5 % Kuhnke 68 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Single-phase Current Monitoring Relay I1540 Standard type Operating range -25 C to +70 C Monitoring of undercurrent for DC and AC voltages VDE0435,0110Gr.C 1510 9 Order Code Order code I 1540. 2 0.1-1 A 24 VAC 50 / 60 Hz Current monitoring relay I Monitored variable 1540 Single-phase - undercurrent I 1540. 2 C/O 2 Monitored current range 2-20 ma 2-20 ma 10-100 ma 10-100 ma 50-500 ma 50-500 ma 0.1-1 A 0.1-1 A 0.5-5 A 0.5-5 A 1-10 A 1-10 A Supply voltage 24 VAC 24 VAC 110 / 115 VAC 110 / 115 VAC 230 VAC 230 VAC 240 VAC 240 VAC 400 VAC 400 VAC 24 VDC * 24 VDC (no frequency stated) Frequency 50 / 60 Hz 50 / 60 Hz * See page 71 for series resistors for the 24 VDC device (for supply voltages above 24 VDC) Contact Data Type of contact Contact material Nominal contact current Inrush current Max. switching capacity Nominal contact voltage I1540 2 C/O Single contact AgCdO 5 A 5 A 1100 VA 250 VAC Kuhnke 69 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Dimensions, Connection Diagram(s) 72 A1 A2 (+) (-) (-)~ - B1 B2 < I 11 21 105.5 45 A2 General Data Display I1540 1 green LED lights if the output relay is pulled up Insulation group VDE 0110b/2.79 C250 Test voltage Auxiliary circuit - output circuit - monitoring circuit Vibration resistance 2500 VAC 4 g at 25-100 Hz (in accordance with GL) Terminals Tension relief terminal with head screws metric M 2.6 Terminal torque Terminal capacity max. 0.6 Nm solid conductor 2 x 1.5 mm 2 flexible conductor with ferrule 2 x 1.5 mm 2 Operating temperature -25 C to +70 C Storage temperature -25 C to +85 C Protection in accordance with DIN 40050 IP40 Housing IP20 Screws IP10 Clamps Mounting Rail in accordance with EN50022-35 x 7.5/15 Screw mounting with mounting plate Weight approx. 300 g Auxiliary Circuit Nominal line voltages Nominal line frequency Voltage ranges see order code 50 / 60 Hz if AC devices AC = ± 20 % at 100 % ED +50 % for 10 s 10 %ED DC = 24 VDC +25 %/-10 % Rated power 2.0 VA cos ϕ 0.7 Kuhnke 70 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Monitoring Circuit Pull-in current I an adjustable acc. to the upper scale Input resistance in Ω I1540 Continuous overload in A Overload duration 1 s in A 2-20 ma 3 0.5 0.63 10-100 ma 1 1 1.25 50-500 ma 0.25 2 2.5 0.1-1 A 0.11 3 3.7 0.5-5 A 0.01 10 12.25 1-10 A 0.005 15 15 Adjustment error 4 % Drop-out current I ab Temperature dependence Permanently adjustable between 0.5-0.99 x I an acc. to the lower scale 0.01 %/K Variance of switching points under identical conditions 0.5 % Monitored value The arithmetic mean value is measured. The scales are adjusted to sinusoidal AC current. If just DC currents without any harmonic contents are measured, the desired switching point should be multiplied by 0.89 and the result set on the scale. Series Resistance for the 24 VDC Device Supply voltage v in VDC 48 VDC 60 VDC 110 VDC 220 VDC Series resistance R v in Ω 470 750 1800 3900 Power rating P of R v in W 1.23 1.7 4.1 9.8 Max. power P of R v in W 1.92 2.7 6.4 15.4 Kuhnke 71 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Frequency Monitoring Relay with Auxiliary Voltage F1570 Operating range -25 C to +70 C Monitoring of underfrequency in AC current systems VDE0435,0110Gr.C 1510 9 Order Code Order code F 1570. 2 10-30 Hz 24 VAC 50 / 60 Hz Frequency-monitoring relay F Monitored variable 1570 underfrequency 1570. 1 C/O / 1 N/O 2 Monitored frequency range F 10-30 Hz 10-30 Hz 20-50 Hz 20-50 Hz 40-65 Hz 40-65 Hz 50-100 Hz 50-100 Hz Supply voltage 24 VAC 24 VAC 110 / 115 VAC 110 / 115 VAC 230 VAC 230 VAC 240 VAC 240 VAC 400 VAC 400 VAC 24 VDC 24 VDC (no frequency stated) Frequency 50 / 60 Hz 50 / 60 Hz * See page 74 for series resistors for the 24 VDC device (for supply voltages above 24 VDC) Contact Data Type of contact Contact material Nominal contact current Inrush current Max. switching capacity Nominal contact voltage F1570 1 C/O / 1 N/O Single contact AgCdO 5 A 5 A 1100 VA 250 VAC Kuhnke 72 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Dimensions, Connection Diagram(s) 72 A1 A2 (+) (-) (-)~ - B1 B2 < f 11 21 12 14 24 105.5 45 12 14 24 X f B A2 General Data Display Insulation group VDE 0110b/2.79 Test voltage Auxiliary circuit - output circuit - monitoring circuit Vibration resistance F1570 1 green LED lights if the output relay is pulled up C250 2500 VAC 4 g at 25-100 Hz (in accordance with GL) Terminals Tension relief terminal with head screws metric M 2.6 Terminal torque Terminal capacity max. 0.6 Nm solid conductor 2 x 1.5 mm 2 flexible conductor with ferrule 2 x 1.5 mm 2 Operating temperature -25 C to +70 C Storage temperature -25 C to +85 C Protection in accordance with DIN 40050 IP40 Housing IP20 Screws IP10 Clamps Mounting Rail EN50022-35 x 7.5/15 Screw mounting with mounting plate Weight approx. 300 g Auxiliary Circuit Nominal line voltages Nominal line frequency Voltage ranges see order code 50 / 60 Hz if AC devices AC = ± 20 % at 100 % ED +50 % for 10 s 10 % ED DC = 24 VDC +25 %/-10 % Rated power 2.0 VA cos ϕ 0.7 Kuhnke 73 Relay Catalogue

1510 VDE0435,0110Gr.C 9 Monitoring Circuit Pull-in frequency f ab adjustable acc. to the upper scale Input resistance in MΩ F1570 Limiting frequency in Hz 10-30 Hz 1 120 20-50 Hz 1 120 40-65 Hz 1 120 50-100 Hz 1 120 Adjustment error 2.5 % Drop-out frequency f an Permanently adjustable between 1.01 and 1.1x f ab acc. to the lower scale Temperature dependence Variance of switching points under identical conditions Monitored value (10-500 V eff ) 0.02 %/K 0.5 % Operation without bridge x-f: frequencies above the set pull-in value energise the output relay. The output relay is de-energised when the frequency falls below the set drop-out value. Operation with bridge x-f: the output relay pulls in if the measuring voltage is above 8 V. The output relay remains pulled in if the voltage is applied at a frequency above the set switching point. Other functions same as operation without bridge x-f. Series Resistance for the 24 VDC Device Supply voltage v in VDC 48 VDC 60 VDC 110 VDC 220 VDC Series resistance R v in Ω 470 750 1800 3900 Power rating P of R v in W 1.23 1.7 4.1 9.8 Max. power P of R v in W 1.92 2.7 6.4 15.4 Kuhnke 74 Relay Catalogue