Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Similar documents
SCALE & WEIGHT DISPLAYS

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

GRT SERIES INSTALLATION & OPERATING INSTRUCTIONS

Operating instructions - High Performance LED Timer / / /

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

DCP100 Digital Control Programmer Specifications

Noise Detector ND-1 Operating Manual

02/11/2015

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Operating instructions Electronic preset counter Type series 717

Model Number Structure

TABLE OF CONTENTS SPECIFICATIONS...1 MOUNTING...3 WIRING...4 THEORY OF OPERATION...6 MILIVOLT INPUT OPTION JUMPER SELECTIONS...7

Eaton Durant. Counters, process instruments and hour meters.

LAUREL ELECTRONICS, INC.

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Single Axis Position Controller

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

SIGNET 5500 Flow Monitor ENGLISH

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

EA402 SERIES ANALOG INPUT FLOW RATEMETER/TOTALIZER INSTALLATION & OPERATING INSTRUCTIONS West Stetson Avenue Hemet, CA USA

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

263 Series LED Bargraph Indicator and Controllers

PRO-CTR100/200 Counter/Rate Controller

Master Time Clock MTC Users Manual

Model 1476-C SuperQuad HR

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

EasyReader Model ER2C

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

K3NX Process Meter OPERATION MANUAL

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Operating Manual RISH OPTIMA VAF

CT340 and CT641. High Performance Low Cost Controller for Rotating Cutters and Printing Rolls. Operating Instructions

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Preset counters, electronic

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Multifunction devices

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

NS-3 RF Noise Source Operation Manual

User Guide. Centrex Recording Interface

3-DRX. AUTOMATIC THREE CHANNEL DIGITAL AES/EBU REPEATER and ANALOG AUDIO SWITCHER INSTALLATION AND OPERATING MANUAL

STD-525T PRECISION TIMER

A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter

Model IQ4-PC User Manual Revision Date:

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

Operating Instructions

Solution Selection Guide

Multifunction Digital Timer

EasyReader Model ER4C

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

Operating Instructions

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

Flexible Counter Series in DIN size 24 x 48 mm

MLW-2 Operating Manual

LEGEND SERIES. DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for

Global Water Instrumentation, Inc.

32 Channel CPCI Board User Manual

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Warner Photoscanner MCS-500 Series LED Photoelectric Control

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Pulse Counters, electronic

INTRODUCTION / DESCRIPTION. Description

Solid-State Digital Timer

THE ASTRO LINE SERIES GEMINI 1000/2000 INSTRUCTION MANUAL

Installation and Operation Manual

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Electronic Pulse Counter Combination device

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Wall-/Pipe-Mount Level Indicator

EZ Encoder : Optical Incremental (P Series)

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Instruction Manual Model BlockUpconverter

16-BIT LOAD CELL/DUAL STATUS INPUT

Smart-Encoder : Optical Incremental

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

L IND. CONT. EQ. 51EB For Model No. PAXLCRU0 Only

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

INSTALLATION & USER GUIDE

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

VA14 INSTALLATION & OPERATING INSTRUCTIONS

Intelligent Security and Fire Ltd

Model 974A Quad Counter/Timer Operating Manual

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

MT03A Electronic converter for flow rate transmitters

MODEL PAXDR - 1/8 DIN DUAL RATE METER / TOTALIZER

Input type NPN/Voltage pulse PNP 240 VAC

Transcription:

Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed to provide instant visual feedback regarding an application s key input value, the C628 not only has a 0.71 high LED display (27% larger than other 1/8 DIN units), but also the ability to change display color based on process status (programmable parameter in Operation Mode). Easy programming is made possible via a help function and a secondary legend display. This manual will guide you through the installation and wiring of your C628 unit with information on proper panel mounting and rear terminal layout and wiring instructions. In addition, the instrument s operation and programming modes are thoroughly explained. The Operation Mode provides day to day operation and allows editing of preset values. The Program Mode enables the configuration of various parameters prior to initial operation. These parameters include those for basic configuration as well as other settable features which will enhance the functionality and usability of the device. This manual also provides information on the C628 Dual Preset Counter s two presets, transistor and relay outputs, product specifications, and ordering and warranty procedures. Technical Manual 702138-0007 Features AWESOME 0.71 high digit LED display Programmable color change display based on an event Programmable help function and secondary legend display Preset 1 programmable as absolute value or Prewarn which tracks Preset 2 Choice of NPN or PNP primary input Filter speed settable for 20, 200, or 10,000 Hz Standard outputs: two NPN transistors & one relay (optional 2nd relay) Front panel reset enable and preset lockout Optional RS-485 plug in card CE approved Index Installation Panel Mounting page 2 Wiring page 3 Operation Front Panel page 4 Operation Mode page 5 Programming Program Mode page 6-10 Appendix A Specifications page 11 General Ordering Information page 12 Warranty page 12 Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX)

I N S T A L L A T I O N PANEL MOUNTING 100mm 82344 48mm 96mm RST 10mm 92mm +0.5-0.0 PANEL CUTOUT SIZE 45mm +0.5-0.0 Mounting Grooves 10 11 12 14 15 16 17 18 19 20 2 3 4 5 6 7 8 The instrument can be mounted in a panel with a thickness of up to 6mm. The cutout(s) should be made based on the recommended panel opening illustrated in the drawing above. Insert the unit in the panel through the cutout. Ensure that the panel gasket is not distorted and the instrument is positioned squarely against the panel. Slide the mounting clamp into place on the instrument, as shown to the left, and push it forward until it is firmly in contact with the rear face of the mounting panel and the tabs on the bracket arm are seated in the mounting grooves on the side of the unit. The electronic components of the instrument can be removed from the housing after installation without disconnecting the wiring. To remove the components, grip the side edges of the panel and pull the instrument forward. Take note of orientation of the unit for subsequent replacement in the housing. 24 23 22 Bracket Arm 2

I N S T A L L A T I O N WIRING REAR TERMINAL CONNECTIONS Power Supply + VDC - RS-485 Comm. (opt.) B A COM Relay 1 14 15 16 17 18 19 20 10 11 12 2 3 4 5 6 7 8 24 23 22 Relay 2 (opt.) NPN Out 2 Common NPN Out 1 Digital In 2 (sec. lockout) Digital In 1 (rem. reset) Aux. Power (opt.) Input Common Input A Input B Count Inputs Terminal #2 is the connection for Input A, which is programmable to be the primary input or channel A of an encoder input. Terminal #1 is the connection for Input B, which is programmable to be an incrementing input, a decrementing input, or channel B of an encoder input. The common connection for both Input A and Input B is Terminal #3. Control/Digital Inputs A contact closure or NPN signal can be used to activate preconfigured functionality. Terminal # 5 is used for a remote reset function, while Terminal #6 is a security function, that when active, will prohibit entry into Program Mode. Terminal #8 serves as the common for both of these inputs. Auxiliary Power Output A 9-15 VDC for powering external sensors and encoders up to 125 ma can be accessed by connecting the positive supply side of the sensor to Terminal #4 and the negative side to Terminal #8. Input Power For an AC powered unit, Terminal #13 serves as the line or Hot side connection for AC powered units and as the positive side for DC powered units. The neutral side for AC powered units and the negative side for DC powered units are connected to Terminal #14. Transistor Outputs Your unit comes standard with 2 NPN outputs which are activated by each of the presets. Transistor Output 1, which is tied to Preset 1 operation, is on Terminal #7. Transistor Output 2, which is tied to Preset 2 operation, is on Terminal #9. Terminal #8 serves as the common connection for the transistor output. Relay Outputs Your unit comes standard with a relay output which is tied to Preset 1 operation. Terminal #19 is NC, Terminal #20 is common, and Terminal #21 is NO. A second relay output tied to the operation of Preset 2 can be added as an option at the time of order of later installed in the field. Terminal #22 is NC, Terminal #23 is common, and Terminal #24 is NO. Serial Communication An RS-485 communication board, utilizing ASCII protocol, can be installed as an option. Terminals #16 & #17 serve as the B and A connections respectively, while Terminal #18 is connected as the common. Terminals 10, 11, 12, & 15 are not used. 3

O P E R A T I O N FRONT PANEL 823451 Primary Display Output Indicators Secondary Display RST Down Key Scroll Key Program Key Reset Key 4 Down Scroll Program Reset Key Down & Scroll together Key Functions Display Functions Function Display Function Primary In Operation Mode: Used in edit operation to decrement the digit highlighted by the Scroll key. In Program Mode: Used in Edit Operation to decrement the digit highlighted by the Scroll key, if the setting is a numerical value, or present the next in the series of choices for that parameter. In All modes: Moves the unit into Edit Operation, which is indicated by the left most digit flashing. Successive presses of the key are used to move to the digit to be edited. Wrap around will occur from least significant digit to most significant digit. In Operation Mode: Used to move between the count value display & the presets and to enter an edited preset value. Holding the key down for 3 seconds will cause the unit to enter Program Mode. In Program Mode: Used to move from one parameter to the next and enter the edited parameter values. Holding the key down for 3 seconds will cause the unit to return to Operation Mode. In Operation Mode: Resets the count value to zero (or to the preset in count down operation). This button can be disabled via the "Front Panel Reset Enable" parameter in Program Mode. In Program Mode: No function. In All modes: Will abort an Edit Operation and return the preset/parameter to its previous value. Secondary Output Indicators In Operation Mode: Default display is the count value. Can be scrolled using the program key to display the Preset 1 and 2 values. If the "Help" function is enabled, this display will first show the parameter description for 3 seconds (see page 5 for example). In Program Mode: Displays the value or selection for the current parameter. If the "Help" function is enabled, this display will first show the parameter description for 3 seconds (see page 6 for example). In Operation Mode: Indicates numerically whether Preset 1 or 2 is being viewed on the primary display. This display is blank when the Count Value is being shown. In Program Mode: Provides a 1 digit alpha or numeric character to indicate which parameter value is being shown on the primary display. In Operation Mode: illuminates when Output 1 is active. illuminates when Output 2 is active. In Program Mode: No function.

O P E R A T I O N OPERATION MODE CHANGING A PRESET VALUE 23456 RST Default display is the present count value. 345671 RST Use the Scroll Key to move from left to right and highlight the digit that needs to be changed. Wrap around will occur from the least significant to the most significant digit. Count RST Pressing the Program Key will cause the display description to appear on the main display.* If there is no key activity for 3 seconds, the primary display will switch back to the count value. 335671 RST Use the Down Key to decrement the digit until the desired value appears. The display will wrap around from 0 to 9. PSEt1 RST 345671 RST Continued pressing of the Program Key will scroll through the Preset. (See Parameter Sequence below.) The full parameter description will appear on the main display.* To change the Preset value, press the Scroll Key. If there was no key activity for 3 seconds, the Preset value will appear (one digit description shown on secondary display); however, press the Scroll Key in order to edit. The unit will now be in Edit Operation as signified by the most significant digit flashing.** PSEt1 RST * Parameter descriptions will not appear on the primary display if the "Help" function has been disabled. After the desired digits have been changed, press the Program Key to enter the new value. The new value will appear on the main display without any flashing digits. Press the Progam Key again and the parameter description will appear on the main display. ** Edit Operation cannot be accessed if the Preset Lock has been enabled in Program Mode. PARAMETER SEQUENCE Count PSEt1 1 Count Function: Displays present count value Range: 0 to 99999 Preset 1 (mutually exclusive with Prewarn) Function: Defines the value at which Output 1 will be activated 0 to 99999 Default Value: 10 PSEt2 2 PLJrn 1 Preset 2 Function: Defines the value at which Output 2 will be activated 0 to 99999 Default Value: 10 Prewarn (mutually exclusive with Preset 1) Function: Sets Preset 2 as a value relative to Preset 1. The input value of Preset 2 equals the count value that Output 2 will activate prior to Output 1. 0 to 99999 Default Value: 10 5

P R O G R A M M I N G PROGRAM MODE ENTERING PROGRAM MODE AND BASIC OPERATION The Program Mode can be accessed from the Operation Mode by holding the Program Key for 3 seconds. 23456 RST The name of the first parameter will appear on the primary display.* CAL for 3 seconds no key activity for 3 secs. or Edit Operation 1.0000 C Successive presses of the Program Key will scroll the display through the remaining parameters in the Program Mode. To exit Program Mode, hold the Program Key for 3 seconds. * Parameter names will not appear on the main display if the "Help" function has been disabled in Program Mode. RST dec P RST RST Pressing the Scroll Key or no key activity for 3 seconds will display the value for that parameter. The secondary display will indicate the one digit identifier for the parameter. The digit in the secondary display will flash to indicate the unit is in Program Mode. If the Scroll Key was pressed (instead of waiting 3 seconds), the unit is in Edit Operation, as indicated by the MSD flashing. If there had been no key activity for 3 seconds, press the scroll key to enter Edit Operation (MSD flashing). Use the scroll and edit buttons to change the value as in Operation Mode, described on page 5. Press the Program Key to enter any changes. PARAMETER SEQUENCE CAL dec C P d Calibration Factor Function: Used to scale the input into engineering units by multiplying this value by the number of pulses received 0.0001 to 9.9999 Default Value: 1.0000 Decimal Position Function: Set the decimal point position for the count and preset displays 0 to 0.0000 Default Value: 0 6

P R O G R A M M I N G PROGRAM MODE Continued countc Count Mode Function: Defines how the input pulses will be applied to the count value A+ b A b dir QuAd A+B: Inputs on both the A & B channels increment the total Default Value: A+B A-B: Inputs on the A channel increment the total, while inputs on the B channel decrement Directional: When input B is inactive, input A increments. When input B is active, input A decrements Quadrature: The unit accepts a phased input from an encoder. The total increments when the A channel leads the B channel UP dn u Count Direction Function: Determines if the count value will increment from zero and change the state of the output at the preset (Up) or decrement from the preset and change the state of the output at zero (Down) up d n up_ar dn_ar Up: The unit will count up from zero and activate the output(s) when the preset(s) is reached Default Value: Up Down: Upon reset, the unit will begin at Preset 1 and count down. The preset output will be activated when the count value reaches zero Up with Auto Reset: The unit will count up from zero and activate the output(s) when the preset(s) is reached, then automatically reset the count value to zero and continue operating Down with Auto Reset: The unit will begin at Preset 2 and incremental pulses will cause the unit to count down. The preset output will be activated when the count value reaches zero. The unit will automatically reset its count value and continue operating P<>od P Preset Mode Function: Determines whether the setting tied to Output 1 will be utilized as an absolute value or a tracking value PSEt 1 PLJrn Preset 1: The setting tied to Output 1 will be utilized as an absolute value Prewarn: The setting tied to Output 1 will be utilized as a tracking value Default Value: Preset 1 7

P R O G R A M M I N G PROGRAM MODE Continued 1nPut i Input Type Function: Programs the unit to match the electrical characteristics of the input signal Sin Sinking: The unit will accept a NPN or dry contact input which sinks voltage to common Default Value: Sinking Src Source: The unit will accept an PNP input which sources voltage SPEEd F Filter Speed Function: Enables the debounce filter of the counter to properly match the application 20 200 10000 20: The unit will accept up to 20 pulses per second. Generally used with contact inputs to eliminate false counts caused by contact bounce Default Value: 10000 200: The unit will accept up to 200 pulses per second. Generally used for higher speed contact inputs or to filter noise on electronic signals in low speed applications 10,000: The unit will accept up to 10,000 pulses per second. Generally used with high speed electronic inputs and encoders OPt 1 1 Output 1 Time Function: Sets the amount of time Output 1 will be active once Preset 1 is reached 00.00 (Latched) to 99.99 Default Value: 1.00 OPt 2 2 Output 2 Time Function: Sets the amount of time Output 2 will be active once Preset 2 is reached 00.00 (Latched) to 99.99 Default Value: 1.00 8

P R O G R A M M I N G PROGRAM MODE Continued rs En r Front Panel Reset Enable Function: Determines whether the Front Panel Reset key can be used to reset the count value En dis Enable: The count value can be reset while being viewed in Operation Mode by pressing the Front Panel Reset Key Default Value: Enable Disabled: The Front Panel Reset Key is disabled and the count value can only be reset through the Remote Reset Input Co<>S Addr baud c A b Serial Communication Enabled Function: Activates the RS-485 communication option board none None: No communication board installed Fit Fitted: A communication board is installed in the unit Default Value: If ordered from the factory with the RS-485 board, the default will be "fitted". If the board is installed in the field, this parameter will need to be changed from its default of "none" Communication Address (Appears only if communication board is installed and activated) Function: Defines the unique communication address of the counter 1 to 99 Default Value: 1 Baud Rate (Appears only if communication board is installed and activated) Function: Selects the serial communication speed 1200 2400 4800 9600 1200 BPS 2400 BPS 4800 BPS 9600 BPS Default Value: 4800 9

P R O G R A M M I N G PROGRAM MODE Continued Color o Display Color Change Function: Defines the color of the display for prior to and after the preset value is reached red GrEEn Gn_rd rd_gn Red: The display will always be red Default Value: Green to Red Green: The display will always be green Green to Red: The display will be green prior to the Preset 2 value being reached. It will turn red after Preset 2 has been reached Red to Green: The display will be red prior to the Preset 2 value being reached. It will turn green after Preset 2 has been reached Loc/ / Preset Lock Function: Determines whether the Preset Values can be changed via the front panel En Enable: Preset values are read only Default Value: Disable dis Disabled: Preset values can be viewed and changed HELP h Help Prompt Function: Determines whether the multi-character parameter name will appear on the main display for 3 seconds prior to the parameter value appearing HLP Y Help - Yes: Multicharacter parameter descriptions will appear on the primary display. The value associated with that parameter will appear by pressing the scroll key or waiting for 3 seconds Default Value: Help - Yes HLP N Help - No: Only the parameter values will appear on the primary display. The parameter can be identified by a single digit in the secondary display 10

A P P E N D I X A SPECIFICATIONS Count Inputs Type: Frequency: Logic: Impedance: Count Modes: Sinking/Sourcing or Contact Closure 10 khz max. Low < 2.0 VDC, High > 3.0, 30V max. 10 KΩ to common - Sourcing 4.7 KΩ to +Voltage - Sinking A+B, A-B, Directional, Quadrature Control Inputs Type: Sinking, Edge Sensitive Logic: Low < 2.0 VDC, High > 3.0 Impedance: 4.7 KΩ to +Voltage Response Time: 25 ms Function: Input 1: Remote Reset Input 2: Security Lockout Outputs Solid State: Relay: Latency: NPN open collector, 30 VDC max, 100 ma max. SPDT, 5A resistive @ 110VAC 75 µ seconds, plus 8 ms for relay pull-in Electrical Supply Voltage: 90-264 VAC, 50/60 Hz, or 20-50 VAC/VDC Power Consumption: 4 Watts Access. Power Supply:9-15 (unregulated VDC), 125 ma max. Display Type: Height: Annunciators: Physical Dimensions: Mounting: Terminals: Front Panel Rating: Case Material: GE Lexan 940 Weight: 0.56 lbs. Red/Green, 7 segment LED, 5 digits primary display, single digit secondary display 0.71" (18mm) primary display, 0.3" (7mm) secondary display Output 1 & 2 status 48mm x 96mm, 110mm deep Panel mount (mounting bracket supplied), 45mm x 92mm cutout Screw type - combination head NEMA 4X/IEC IP65 Approvals General: CE EMC Susceptibility: Complies with EN50082-1: 1992, EN50082-2: 1995 EMC Emissions: Complies with EN50081-1: 1992, EN50081-2: 1994 Safety: Complies with EN61010-1: 1993 Environmental Operating Temp.: Storage Temp.: Relative Humidity: 0 to 55 Celsius, 32 to 131 Fahrenheit -20 to 80 Celsius, -4 to 176 Fahrenheit 20% to 95% non-condensing Communication Type: Serial asynchronous, UART to UART Data Format: Open ASCII: One start bit, even parity seven data bits, one stop bit Physical Layer: RS-485 Maximum Zones: 99 Baud Rate: Selectable from 9600, 4800, 2400, or 1200 11

G E N E R A L ORDERING INFORMATION C628-8 0 2nd Relay Option 0 None 1 2nd Relay Serial Communication Option 0 None 5 RS-485 Power Supply 0 90-264 VAC 2 20-50 VAC/VDC Additional outputs and options can be field installed through plug-in boards which can be ordered separately. Description Part # Relay Board T50-001 RS-485 Comm. Board T50-005 WARRANTY Standard products manufactured by the Company are warranted to be free from defects in workmanship and material for a period of one year from the date of shipment, and products which are defective in workmanship or material will be repaired or replaced, at the option of the Company, at no charge to the Buyer. Final determination as to whether a product is actually defective rests with the Company. The obligation of the Company hereunder shall be limited solely to repair and replacement of products that fall within the foregoing limitations, and shall be conditioned upon receipt by the Company of written notice of any alleged defects or deficiency promptly after discovery within the warranty period, and in the case of components or units purchased by the Company, the obligation of the Company shall not exceed the settlement that the Company is able to obtain from the supplier thereof. No products shall be returned to the Company without its prior consent. Products which the Company consents to have returned shall be shipped F.O.B. the Company's factory. The Company cannot assume responsibility or accept invoices for unauthorized repairs to its components, even though defective. The life of the products of the Company depends, to a large extent, upon the type of usage thereof, and THE COMPANY MAKES NO WARRANTY AS TO FITNESS OF ITS PRODUCTS FOR SPECIFIC APPLICATIONS BY THE BUYER NOR AS TO PERIOD OF SERVICE UNLESS THE COMPANY SPECIFICALLY AGREES OTHERWISE IN WRITING AFTER THE PROPOSED USAGE HAS BEEN MADE KNOWN TO IT. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Printed in U.S.A. 702138-0007 March 1998 Revision none Danaher Controls 1675 Delany Road Gurnee, IL 60031 1282 Phone: 847.662.2666 Fax: 847.662.6633 12