VPO Technology 1 / 6 GOOD WILL INSTRUMENT CO., LTD.

Similar documents
GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

What's the SPO technology?

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Oscilloscopes, logic analyzers ScopeLogicDAQ

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Zeroplus Logic Analyzer Multi-LA Stack and LA-Oscilloscope Stack

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

What to look for when choosing an oscilloscope

Realizing Waveform Characteristics up to a Digitizer s Full Bandwidth Increasing the effective sampling rate when measuring repetitive signals

4. ANALOG TV SIGNALS MEASUREMENT

Choosing an Oscilloscope

Portable Performance for Debug and Validation

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

2016 RIGOL TECHNOLOGIES, INC.

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

Digital Oscilloscope. Characterisation, Measurement & Analysis

Digital Storage Oscilloscopes 2550 Series

Time-Saving Features in Economy Oscilloscopes Streamline Test

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

EMI/EMC diagnostic and debugging

The Impact of Digital Oscilloscope Blind Time on Your Measurements Application Note

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

Presented by: Amany Mohamed Yara Naguib May Mohamed Sara Mahmoud Maha Ali. Supervised by: Dr.Mohamed Abd El Ghany

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Expect to Make Waves.

DS4000 Series Digital Oscilloscope

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Agilent Technologies 54522A

8 DIGITAL SIGNAL PROCESSOR IN OPTICAL TOMOGRAPHY SYSTEM

How advances in digitizer technologies improve measurement accuracy

Advanced Skills with Oscilloscopes

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Debugging a Mixed Signal Design with a Tektronix Mixed Signal Oscilloscope

ATS MS/s 8-Bit PCI Digitizer

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

50 MHz Digital Storage Oscilloscope

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

Max. sampling rate (realtime) channel. interleaved. 1 Gsample/s. interleaved. 2.5 Gsample/s per channel 5 Gsample/s. 5 Gsample/s per channel

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Elements of a Television System

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

CATHODE-RAY OSCILLOSCOPE (CRO)

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Dynamic re-referencing Microvolt-level measurements with the R&S RTO oscilloscopes

SDS1000C Specifications

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

R&S HMO1002, R&S HMO1202 Two-channel digital oscilloscopes 50 MHz to 300 MHz bandwidth. Test & Measurement Product Brochure 02.01

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

DataSheet SDS1000CFL Series Digital Oscilloscope

PicoScope 2000 Series 2-CHANNEL OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

The Measurement Tools and What They Do

CHAPTER 4 OSCILLOSCOPES

Digital Storage Oscilloscope

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

Evaluating Oscilloscopes to Debug Mixed-Signal Designs

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

PicoScope 3000 Series HIGH-PERFORMANCE 4-CHANNEL OSCILLOSCOPES

SX-METRO A software package to meet all your needs

PicoScope 3000 Series

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Debugging Digital Cameras: Detecting Redundant Pixels

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Major Differences Between the DT9847 Series Modules

What's the difference between history and sequence. function?

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

User Manual. SDS1000X-E Series Digital oscilloscope UM0101X-E02B SIGLENT TECHNOLOGIES CO., LTD.

DataSheet. SDS1000DL Series Digital Oscilloscope

1. Abstract. Mixed Signal Oscilloscope Ideal For Debugging Embedded Systems DLM2000 Series

ADS1000C, CAL / CML Series

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

User Manual. SDS2000X Series Digital Oscilloscope UM0102X-E01A 2015 SIGLENT TECHNOLOGIES CO., LTD.

FOCUS VOLTAGE ADJUSTMENT 1. Receive RETMA pattern signal. 2. Adjust the FOCUS VOLUME on the FBT and make the picture on the screen be finest.

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

PC Oscilloscope Spectrum Analyzer Logic Analyzer

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

1 scope channel. 2 scope channels* 200 MSa/s 4 MB memory/ch. 200 MSa/s 2 MB memory/ch. 200 MSa/s 2 MB memory/ch

Measuring with digital storage oscilloscopes

HX0074 DEMO Kit for METRIX Oscilloscopes

Oscilloscopes cannot be replaced by any other measuring instru ments

DataSheet SDS1000CML Series Digital Oscilloscope

Techniques for Extending Real-Time Oscilloscope Bandwidth

Introduction to Data Conversion and Processing

ADS1000 Series Digital Storage Oscilloscope Version No.: V 1.0

An Efficient SOC approach to Design CRT controller on CPLD s

4CH/2CH Digital Storage Oscilloscopes

Information Transmission Chapter 3, image and video

DSO7032A Oscilloscope: 350 MHz, 2 channels

Transcription:

VPO Technology 1 / 6

The GW Instek GDS-3000 Series digital storage oscilloscopes are equipped with a built-in self-developed waveform image processing system which significantly enhances the waveform capture rate. We call this VPO (Visual Persistence Oscilloscope) Technology. The first generation of analog oscilloscopes (Analog oscilloscope CRT display as shown in Figure Fig. 1a) utilized fluorescent materials to capture fast electronic signals to generate a dot on a screen. By controlling the intensity and bias of an electron beam, the brightness and tracking of a signal could be generated. This was used to reconstruct a waveform image that would be displayed on a screen for a short time. For this reason, one can observe the details of a signal while the signal is changing with the naked eye. Fig. 1a Analog Oscilloscope Fig. 1b Digital Storage Oscilloscope Digital storage oscilloscopes, usually viewed as 2nd generation oscilloscope (DSO, as shown in Figure Fig. 1b) mainly convert analog signals into digital signals through high-speed analog to digital converters (ADC). These signals are then stored in its memory for the CPU to process and draw the waveform. The design of a DSO puts some of its functions far beyond the reach of analog oscilloscopes. For example: waveform storage, math operations (Example: - * / FFT), automatic measurements and pre-triggers. The only reason why analog oscilloscopes still fascinate so many people is because of their ability to display a signal in real-time. Conversely, this is also the greatest disadvantage of digital storage oscilloscopes. As the CPU in a DSO does not have the processing power to process a waveform as fast as the signal is changing; only part of the signal is captured and processed. The section of time for when a signal is not captured is called Dead Time (Fig. 1c). The longer the dead time is, the greater the chance of not detecting a rapid change in the signal. If a DSO cannot detect such signals then it is unable to meet the demands of a modern measurement instrument. Fig.1c Dead Time The waveform image processing system designed and developed by GW Instek are mainly used to share the data 2 / 6

processing with the CPU, shortening the time needed to draw a waveform and consequently increasing the waveform capture rate. Furthermore, in order to create a display performance similar to that of analog oscilloscopes, the waveform data for all channels is displayed as a three dimensional image (amplitude, time and intensity). When a strong signal is generated, the waveform will be brighter and the waveform will persist for a longer time, allowing users to easily grasp any instantaneous changes in the waveform. By using an image processing system, waveform data can be quickly acquired by the DSO, processed and displayed on the screen with multiple levels of intensity almost as quickly as an analog oscilloscope. Fig 2 VPO Illustration By using VPO technology and a 5 GSa/sec sampling rate, the GDS-3000 Series significantly enhances waveform capture rate, allowing users to clearly observe video signals, DVD signals, and FM signals. Video Signal Acquisition DVD Signal Acquisition FM Signal Acquisition 3 / 6

By adjusting the intensity and persistence of waveforms, the GDS-3000 Series enables users to clearly observe and analyze intermittent events. Waveform Intensity Waveform Persistence Time Therefore, the new generation of VPO oscilloscopes are equipped with the characteristics of analog oscilloscopes and the numerous features of second generation digital storage oscilloscopes, including: waveform storage, math operations (Example: + - * / FFT), automatic measurements and other accurate measurement functions. With these features, the GDS-3000 becomes the best instrument for analyzing intermittent events and video signals. 4 / 6

GDS-3000 Series Introduction GDS-3000 series is an innovative testing platform providing up to 350 MHz bandwidth, 4 analogue input channels, 5GSa/s, and VPO technology (Visual Persistence Oscilloscope). Beside these, it also equips an innovative split screen system with independent horizontal settings, vertical settings and triggers. This is a new function which can be used in testing, research, and manufacturing. With power analysis and serial bus analysis software, GDS-3000 series also enables engineers to expedite product testing, developing, and manufacturing. Features * 350/250/150MHz with 2/4 Channels * 5GSa/s RT or 100GSa/s ET Sampling Rate * Independent Memory for Each Channel * VPO Technology * Large 8-inch 800x600 Display * Split Screen Function * 3 Built-in Impedances (50Ω/75Ω/1MΩ) * Power Analysis Software (Optional) * Serial Bus Analysis Software for I2C, SPI and UART (Optional) GDS-3000 series GDS-3152 GDS-3154 GDS-3252 GDS-3254 GDS-3352 GDS-3354 Channels 2Ch + Ext 4Ch + Ext 2Ch + Ext 4Ch + Ext 2Ch + Ext 4Ch + Ext Bandwidth DC~150MHz (-3dB) DC~250MHz (-3dB) DC~350MHz (-3dB) sampling rate memory length 2.5GSa/s 5GSa/s 2.5GSa/s 5GSa/s 5GSa/s 5GSa/s 25k points For more information about product, power analysis software, and its corresponding accessories, please visit our website: http:///en/product/productdetail.aspx?pid=3&mid=7&id=1290 5 / 6

6 / 6