FT730 Guide System 5

Similar documents
PN REV A 08/10. Stage Rack for VENUE Systems

Personal Q Guide for VENUE Systems

Evolution Digital HD Set-Top Box Important Safety Instructions

Operating Instructions

HD Digital Set-Top Box Quick Start Guide


DisplayPort Extender over 2 LC Fibers

D-Command. Fader Module Installation Guide. Version 7.4

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

DisplayPort Extender over 2 LC Fibers

Register your product and get support at SDV5122/27. EN User manual

2.0 Wall Mount TV Soundbar Instruction Manual

HD Digital MPEG2 Encoder / QAM Modulator

FC726 Guide System 5

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

HD Digital MPEG2 Encoder / QAM Modulator

EXT-UHD600-1SC Version A1

Multi-Channel Passive Transceiver Hubs Installation Sheet

SYNC HD. Firmware Version 2.1.1

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

ZvBox 150. HD video distribution over COAX Get Going Guide

MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor

ATTACHING & REMOVING THE BASE

TS2.8 Sub OWNER S MANUAL


Model 1606 Super. User Manual

Disclaimer. Trademarks. Copyright. Contact Us Control4 Corporation S. Election Road Salt Lake City, UT USA

MON8-1 1U 8-Channel Multi-Display Video Monitor

1812R Blues King 12. User Manual

User Manual CONTENTS. Title and Contents Introduction and Warranty Section 1: General Features and Specifications... 3

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

SKYPLAY-MX Installation and Operation Guide

Installation Manual VIP 1003

HD OMNI Guide. Version 8.1

Extender w/ RS-232 and 2-way IR

Amulet 4. Quick Start Guide

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL


BP2-MM MM Phono Preamplifier Owner s Manual

WS55 INSTRUCTION MANUAL

VENUE Profile Guide. and VENUE D-Show Software Version Digidesign Junipero Serra Boulevard Daly City, CA USA

User Manual CONTENTS. Title and Contents Important Safety Instructions and Introduction... 2

KD-CTCA3. Component Video to VGA Adapter

Check our knowledge base at

4 PORT HDMI SWITCH

PH-1. Italian MM & MC Phono Preamplifier OWNER S MANUAL

Reveal 402 / 502 / 802. English Manual

Technical Specifications

Kamai 4 Media Receiver. Quick Start Guide

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

BP2-MM/MC Phono Preamplifier Owner s Manual

Content. User s Manual 3. Owner s Manual Ver. 1.1 / June Introduction...4. Mytek Package Content Features...

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Q-TV2. User Manual. for Screens

Amulet 6. Quick Start Guide

ZVOX AccuVoice TV Speaker Model AV203

ZVOX AccuVoice TV Speaker Model AV203

9.7-INCH VALUE LED MONITOR

55" Curved Ultra HD LED TV User s Guide for Model TU5587B v For the most up-to-date version of this User s Guide, go to

SwiftMix Automation Safety

Kamai 6 Media Receiver. Quick Start Guide

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

Wireless 4 Channel Receiver with 2 Night Vision cameras

Audio. 4K Ultra HD Extender. w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK. User Manual. Release A2

Audio. Extender. for HDMI GBT-HDBT-POL. User Manual. Release A7

28 4K LED monitor. User Manual M284K

SpectraPulse Ultra Wideband Wireless Microphone System

TV Ears TV Speaker Installation Guide

Introduction. Important Safety Instructions

HID-C10 Important Information Guide

SATRI AMPLIFIER AMP-51R. Owner s Manual

KD-CSW2x1. Operating Instructions. 2 Inputs to 1 Output Component Video/Audio Switcher. KD-CSW2x1 Operating Instructions.

E325 Series User Guide

Wired to Wireless Camera Converter

Disclaimer. Warning and Caution CAUTION!

Home Entertainment Server

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

27'' Full HD LED Monitor KALED27MONSC Quick Start Guide

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Prodipe DSP UHF systems and microphones

U65 Series User Guide

Media Receiver. Quick Start Guide

BM5 mkiii Owner s manual

X50 Series User Guide

AT-MX351a SmartMixer. Automatic Mixer. Installation and Operation. Output Level Gain 1 Gain 2 Gain 3 Gain 4 Aux In Master Monitor. Priority Pre-select

Amulet 5. Quick Start Guide

By CHANNEL VISION. Flush Mount Amplifier A0350

X-Series Expansion Cards. X-Video Card

TV Ears Wireless Speaker User Manual

E246 Series User Guide

DISTRIBUTION AMPLIFIER

E246 Series User Guide

User Guide. Connecting the Explorer 1850 Digital Home Communications Terminal

HDMI 4x2 Matrix Switch 1.3b

Monochrome Video Monitors

ZIG-POC-100. HDBaseT HDMI Extender

VIZIO MODELS. n E191VA n E221VA QUICK START GUIDE HD PICTURE SLIM DESIGN LED FULL USER MANUAL AVAILABLE AT VIZIO.COM

Transcription:

FT730 Guide System 5

Legal Notices This guide is copyrighted 2011 by Avid Technology, Inc., (hereafter Avid ), with all rights reserved. Under copyright laws, this guide may not be duplicated in whole or in part without the written consent of Avid. 003, 96 I/O, 96i I/O, 192 Digital I/O, 192 I/O, 888 24 I/O, 882 20 I/O, 1622 I/O, 24-Bit ADAT Bridge I/O, AudioSuite, Avid, Avid DNA, Avid Mojo, Avid Unity, Avid Unity ISIS, Avid Xpress, AVoption, Axiom, Beat Detective, Bomb Factory, Bruno, C 24, Command 8, Control 24, D-Command, D-Control, D-Fi, D-fx, D-Show, D-Verb, DAE, Digi 002, DigiBase, DigiDelivery, Digidesign, Digidesign Audio Engine, Digidesign Intelligent Noise Reduction, Digidesign TDM Bus, DigiDrive, DigiRack, DigiTest, DigiTranslator, DINR, DV Toolkit, EditPack, Eleven, HD Core, HD I/O, HD MADI, HD OMNI, HD Process, Hybrid, Impact, Interplay, LoFi, M-Audio, MachineControl, Maxim, Mbox, MediaComposer, MIDI I/O, MIX, MultiShell, Nitris, OMF, OMF Interchange, PRE, ProControl, Pro Tools, Pro Tools HD, QuickPunch, Recti-Fi, Reel Tape, Reso, Reverb One, ReVibe, RTAS, Sibelius, Smack!, SoundReplacer, Sound Designer II, Strike, Structure, SYNC HD, SYNC I/O, Synchronic, TL Aggro, TL AutoPan, TL Drum Rehab, TL Everyphase, TL Fauxlder, TL In Tune, TL MasterMeter, TL Metro, TL Space, TL Utilities, Transfuser, Trillium Lane Labs, Vari-Fi, Velvet, X-Form, and XMON are trademarks or registered trademarks of Avid Technology, Inc. Xpand! is Registered in the U.S. Patent and Trademark Office. All other trademarks are the property of their respective owners. Product features, specifications, system requirements, and availability are subject to change without notice. Guide Part Number 9329-65140-00 REV A 08/11 Documentation Feedback We are always looking for ways to improve our documentation. If you have comments, corrections, or suggestions regarding our documentation, email us at techpubs@avid.com.

Contents Chapter 1. Introduction to the FT730............................................................... 1 System Requirements and Compatibility............................................................. 1 About This Guide.............................................................................. 1 About www.avid.com........................................................................... 2 Chapter 2. FT730 Features........................................................................ 3 Front Panel.................................................................................. 3 Back Panel.................................................................................. 4 Specifications................................................................................ 6 Applications................................................................................. 7 Technical Reference........................................................................... 8 Appendix A. Compliance Information............................................................... 9 Environmental Compliance....................................................................... 9 EMC (Electromagnetic Compliance)................................................................ 10 Safety Compliance........................................................................... 11 Contents iii

iv FT730 Guide

Chapter 1: Introduction to the FT730 The FT730 FiberTran Fiberoptic Extender allows an ML530 Microphone/Line preamplifier or MC524 Monitor Controller to be placed up to 3300 ft (1 km) away from the processing core of an Avd Pro Series digital console. The FT730 is always used in pairs with one local unit at the control end and one remote unit at the far end connected by up to 1 km of fiberoptic cable. Normally, four fibers are used: One pair sends audio sync and control information to the remote end and receives status information back. The second pair sends and receives MADI. The same device is used at both ends but their functionality differs: If a sync source is connected (AES or word clock), it is a local unit; otherwise, the device looks for sync on the sync fiber and, if found, behaves as a remote unit. System Requirements and Compatibility Avid can only assure compatibility and provide support for hardware and software it has tested and approved. For complete system requirements and a list of qualified computers, operating systems, hard drives, and third-party devices, visit www.avid.com/compatibility. About This Guide This guide provides a basic overview of FT730 features and functionality. For complete instructions on connecting and configuring your system, see the System 5 Installation Guide. Conventions Used in This Guide All of our guides use the following conventions to indicate menu choices and key commands: : Convention File > Save Control+N Control-click Right-click Action Choose Save from the File menu Hold down the Control key and press the N key Hold down the Control key and click the mouse button Click with the right mouse button The names of Commands, Options, and Settings that appear on-screen are in a different font. The following symbols are used to highlight important information: User Tips are helpful hints for getting the most from your system. Important Notices include information that could affect your data or the performance of your system. Shortcuts show you useful keyboard or mouse shortcuts. Cross References point to related sections in this guide and other Avid guides. Chapter 1: Introduction to the FT730 1

About www.avid.com The Avid website (www.avid.com) is your best online source for information to help you get the most out of your system. The following are just a few of the services and features available. Product Registration Register your purchase online. Support and Downloads Contact Avid Customer Success (technical support); download software updates and the latest online manuals; browse the Compatibility documents for system requirements; search the online Knowledge Base or join the worldwide Avid user community on the User Conference. Training and Education Study on your own using courses available online or find out how you can learn in a classroom setting at a certified Avid training center. Products and Developers Learn about Avid products; download demo software or learn about our Development Partners and their plug-ins, applications, and hardware. News and Events Get the latest news from Avid or sign up for a demo. 2 FT730 Guide

Chapter 2: FT730 Features Front Panel The front panel has LEDs that indicate the status of the power supplies, synchronization activity, and the status of several other functions. Each group is discussed in the following sections. FT730 Front Panel 3 2 1 FT730 front panel (detail) 1. Power The system has two power supplies for redundancy. A simple monitoring circuit checks whether each supply is functioning within allowable limits and displays their status on the PSU 1 and PSU 2 LEDs on the front panel. The information is also sent over the fiber link to the remote end. The LEDs indicate the following status: Solid Both power supplies are functioning normally. Flashing Remote power supply has failed. Off Local power supply has failed. 2. Sync If the unit is locked to Word or AES sync, it is designated as the local unit and sends digital sync to the remote unit over the fiber link. 3. Status TCC Indicates TCC data activity. Loop Indicates that the TCC/Sync fiber loop is complete and the time of flight has been calculated. MADI IN Indicates that a MADI signal is present on the 75-W BNC MADI In and also on the Fiber TX connector. MADI OUT Indicates that a MADI signal is present on the 75-W BNC MADI Out and also on the Fiber RX connector. Remote The unit is locked to sync coming from the local unit over the fiber link. Word The unit is locked to sync on the word clock sync input. AES The unit is locked to sync on the AES sync input. Chapter 2: FT730 Features 3

Back Panel 1 I O 1 I O FT730 back panel 1. Power Connectors (IEC) Accepts two standard IEC power cords (provided). Two autoranging switching supplies accept voltages in the range 100 240 VAC, 50 60 Hz. 1 2 3 FT730 back panel (detail) 1. AES/SYNC IN (female XLR or BNC), WORD IN (BNC) Connect this port to a digital sync reference (local unit only). Selection for XLR or BNC input is done using two internal jumpers shown in Figure 4. The unit is shipped with the jumpers set for the XLR input. 2. AES/SYNC OUT (male XLR or BNC), WORD OUT (BNC) Connect one of these ports to the digital sync reference input of any device receiving MADI at the remote unit. Only one output connection (XLR or BNC) should be used at a time. 3. RETIMED AES/SYNC OUT (male XLR), RETIMED WORD OUT (BNC) Connect one of these ports to the digital sync reference input of any device sending MADI from the remote unit back to the local unit. See Synchronization for Distances Over 800 ft (250 m) on page 13 for more information about these outputs. 4 FT730 Guide

BNC XLR Internal sync input jumper 1 2 4 3 5 1 Back panel TCC, MADI, and fiber connectors 1. TCC IN/Out (DB15) Connect TCC IN to TCC control port at local unit. Connect TCC OUT to TCC control port at remote unit. Because the same unit is used at both ends, each has a TCC IN and a TCC OUT connector. However, only the TCC IN is intended to be used at the local end and the TCC OUT at the remote end. 4. MADI IN (BNC) MADI connection for signal being transmitted over fiber. 5. MADI OUT (BNC) MADI connection for signal being received from fiber. 2. FIBER SYNC/TCC TX/RX (ST Optical Connector) Connects local and remote units. Connect local RX and TX to remote TX and RX, respectively. Both connections are required for proper operation. 3. FIBER MADI TX/RX (ST Optical Connector) Connects local and remote units. Connect local RX and TX to remote TX and RX, respectively. A single connection can be used if MADI signals are only required for one direction. Chapter 2: FT730 Features 5

Specifications 16.92" 17.00".40" 19.00" 3.47" (2RU) FT730 dimensions Weight Power Cable Requirements 11.6 lb (5.2 kg) 25 W The FT730 s fiber transceivers work only with 62.5/125 mm multimode fiber with ST connectors. Maximum Fiber Distance 3300 ft (1000 m) 6 FT730 Guide

Applications From Sync Distribution From PC253i TCC Port To DF64 or SH612 MADI Input I O I O I O I O Fiber Control Sync MADI To AM713 Sync Input To ML530 TCC Port From AM713 MADI Output FT730 connection diagram Chapter 2: FT730 Features 7

Technical Reference Synchronization for Distances Over 800 ft (250 m) MADI utilizes a polarity-free, serial NRZI (non-return-to-zero inverted) protocol with encoding at 125 Mbit/s (±100 ppm). Sample timing is controlled independently by distributing a master synchronization signal. Originally, the transmission medium was 75-W coaxial cable. There are two important synchronization issues: The MADI signal s transmitted frame start time must be within 5% of the sample period time determined by the synchronizing signal. This requirement is usually met by the circuit design using the distributed synchronization signal. The received frame start time must be within ±25% of the sample period reference time. This requirement is governed by physics: it is the time of flight (delay time) difference between the sample start and the start of the frame. The speed of light (299,792,458 m/s) and the propagation speed of the transmission medium govern this delay time. Single Mode vs. Multimode Fiber Optic Cable In optical fiber technology, multimode fiber is optical fiber that is designed to carry multiple light rays (modes) concurrently. Each mode is carried at a slightly different reflection angle within the optical fiber core. Multimode fiber transmission is used for relatively short distances (less than 6500 ft/2000 m) because the modes tend to disperse over longer lengths (modal dispersion). For distances longer than 6500 ft (2000 m), single mode fiber (sometimes called monomode) fiber is used. Multimode fiber has a typical core diameter of 50 100 mm with a refractive index that is graded or stepped. It allows the use of inexpensive LED light sources, and connector alignment and coupling is less critical than for single mode fiber. This translates into lower connection and electronics costs and consequently lower overall system costs. The FT730 uses 62.5/125 mm multimode fiber with ST connectors. Transmission mediums, such as fiber and coaxial cable, have propagation speeds in the range 60 70% of the speed of light. This does not present a problem when MADI and the synchronization signal are sent together to a destination, such as a MA703. The problem manifests when MADI is used to return data from a source such as an AM713, where the delay time difference for the MADI and synchronization signals exceeds the received frame start time requirement (±25% of the sample period reference time). The FT730 has two types of synchronization outputs: AES/Sync or Word Out Used for devices receiving MADI at the remote end. These outputs are used if the signal meets the criteria stated in the first bullet above. Retimed AES or Retimed Word Sync Used for devices transmitting MADI to the local end. The control/sync fiber pair is used to measure at the local end by comparing the local sync timing with that returned from the remote end. This number is sent to the remote end where the timing is adjusted in sixteenth frame increments to keep it within the operational requirements stated in the second bullet above. 8 FT730 Guide

Appendix A: Compliance Information Environmental Compliance Disposal of Waste Equipment by Users in the European Union Proposition 65 Warning This product contains chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. Perchlorate Notice This product may contain a lithium coin battery. The State of California requires the following disclosure statement: Perchlorate Material special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate. This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city recycling office or the dealer from whom you purchased the product. Recycling Notice Appendix A: Compliance Information 9

EMC (Electromagnetic Compliance) Avid declares that this product complies with the following standards regulating emissions and immunity: FCC Part 15 Class A EN55103-1 E4 EN55103-2 E4 AS/NZS CISPR 22 Class A CISPR 22 Class A FCC Compliance for United States Communication Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Any modifications to the unit, unless expressly approved by Avid, could void the user's authority to operate the equipment. Australian Compliance N1709 Canadian Compliance This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le material brouilleur du Canada. CE Compliance (EMC and Safety) Avid is authorized to apply the CE (Conformité Europénne) mark on this compliant equipment thereby declaring conformity to EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC. 10 FT730 Guide

Safety Compliance Safety Statement This equipment has been tested to comply with USA and Canadian safety certification in accordance with the specifications of UL Standards: UL 60950-1:2007, 2nd Ed and CAN/CSA-22.2 No. 60950-1-07, 2nd Ed. Avid Inc., has been authorized to apply the appropriate NRTL mark on its compliant equipment. Warning 13) Unplug this equipment during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the equipment has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate normally, or has been dropped. 15) For products that are a Mains powered device: The equipment shall not be exposed to dripping or splashing and no objects filled with liquids (such as vases) shall be placed on the equipment. Warning! To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. 16) For products containing a lithium battery: CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. 17) For products with a power switch: It should remain accessible after installation. 18) The equipment shall be used at a maximum ambient temperature of 40 C. Important Safety Instructions 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this equipment near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other equipment (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 19) This unit is provided with a power supply cord set suitable for 120V AC input only (for U.S.A.and Canada). For other than U.S.A. and Canada, a qualified person must provide for use with this unit, an appropriate, approved power supply cord set which is in compliance with the end use country requirements and has a minimum cross-sectional area of 1.0mm2. 20) For units with more than one power cord: CAUTION: This unit has more than one power supply cord. Disconnect two power supply cords before servicing to avoid electrical shock. ATTENTION: Cet appareil comporte plus d un cordon d alimentation. Afin de prévenir les chocs électriques, débrancher les deux cordons d alimentation avant de faire le dépannage. 21) For products with an operator-accessible fuse: CAUTION: For continued protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromettre la protection contre les risques d incendie, remplacer par un fusible de même type et de même caractéristiques nominales. 10) Protect power cords from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the equipment. 11) Only use attachments/accessories specified by the manufacturer. 12) For products that are not rack-mountable: Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the equipment. When a cart is used, use caution when moving the cart/equipment combination to avoid injury from tip-over. Appendix A: Compliance Information 11

12 FT730 Guide

Avid 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA Technical Support (USA) Visit the Online Support Center at www.avid.com/support Product Information For company and product information, visit us on the web at www.avid.com