Photo: HELUKABEL. Special Cables T 1

Similar documents
Photo: HELUKABEL â. Special cables

Cables for robot applications

Continuous Flex Data Cable

PRODUCTS COMPANY SERVICES

Flygt Submersible Motor Cables

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

BUS UNITRONIC BUS CAN

Instrumentation Cables

17 Bulk Cables INSTRUMENT CABLES SS/ONE CS/535 CS/ SS/ONE SONIC SOLUTIONS HIGH DEFINITION INSTRUMENT CABLE MADE IN ITALY

12 Prefabricated cables

Bus Cables & Industrial Ethernet Cables

Polymer optical fibre as duplex fibre cable version with PCV or PUR sheath for PROFINET applications type B or C

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

HITRONIC Optical Transmission Cable

HARTING Ethernet cabling cables and connectors, 4 wire

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Mining and Petrochemical Fiber Optic Cables

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

Compact Module. Category 6 FTP Cabling System

CATEGORY 6 CABLING SOLUTIONS

CABLES AND WIRES

Connecting cables NEBS, for sensors

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

11 Prefabricated cables

PRODUCT INFORMATION NYY-J, NYY-O

CHAINFLEX CABLES TESTED FOR GUARANTEED PERFORMANCE

Instrumentation & copper telecom cables

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

Cable installation guidelines

Continuous High-Flex Cable for Automated Systems

Our cables at: ENGLISH CHANNEL TALLIN PORT MECCA METRO PULKOVO AIRPORT

Cables Cable protectors

Scotch Heavy Duty Vinyl Electrical Tape 22

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

GenSPEED Category 5e Cables 3

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

PREMIUM 5e F/UTP PRODUCTS

Connecting cables for valves, round plug connectors Product range overview

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Connectivity for Ethernet

CATEGORY 5e CABLING SOLUTIONS

Connecting cables for valves, Sub-D Type codes

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

OPTICAL CABLE FIBER-LAN INDOOR

RZ1-K BS EN XLPE LSZH Flexible Cable

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Revision No. 4 Page No. Page 1 of 7

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

CATEGORY 6A CABLING SOLUTIONS

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

Instructions. Cable with Armor F CAUTION. October Rev A

PROFIBUS Optical networks with OLM

Detailed Specifications & Technical Data

Magic Patch Patch Leads & Accessories

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

CATEGORY 6A CABLING SOLUTIONS

Siam Pacific Electric Wire & Cable Co., Ltd.

02/11/2015

Micro duct Cable with HDPE Sheath for Installation by Blowing

DIAS power supply and DIC 221 fibre optic cable coupling module

technology Live on stage our cables!

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Automation. Automation. Guide for Servo Motors/Drives and BUS Systems. Make the right connection.

3M Super 23 Electrical Tape

SPECIFICATION. Optical Fiber Cable

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Brands that. Power. the Industry

Detailed Specifications & Technical Data

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Category 5e F/UTP Euroclass D ca Cables

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Detailed Specifications & Technical Data

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

LED MODULES READYLINE DL

3M Sensored Termination (15 kv) QX-T15I-vi1-E

High Voltage Cables kv. Handling and Operating Instructions

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Kwangil Electronic Introduction

Lightweight Low Fire Hazard Cables according to VG95218 part 28. Marine application profile with cross-reference to VG95218, parts 61 to 66

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Gear up for the future.

Volition TM Category 5e cable 100 Ω, FTP

If you can t find what you re looking. CABLEMASTER Range of Cables. for we can make it!

Generator protection relay

Comprehensive elevator cable systems Catalogue

BTNS TM. FTP Compact Module

STRUCTURED CABLING SYSTEMS (SCS)

btnet new products Modular and preloaded patch panels btnet

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Transcription:

Special Cables

Photo: HELUKABEL Special Cables T 1

Special Cables The name HELUKABEL stands for standard cables and lines, cables for data technology, preassembled cables, cable accessories and also special cables such as system cables and all types of customised special solutions. And we ve been doing it for 30 years. We design, construct, and produce insulation and sheath materials for standard to high tech applications, including PVC, PE, PP, TPE-E, TPE-O, PUR, silicon, fluoro-plastics, halogen-free polymers, to name just a few. Our cables meet requirements in terms of reelability, suitability for drag chains, increasingly high speed and acceleration, as well as extreme alternating bending cycles for a minimum bending radius, and resistance to rough environmental conditions regarding high and low temperatures, humidity, oils, petrol and other chemicals. Our qualified staff in the Special Cables department would be happy to advise you on an individual basis and develop and design your leads. We set great store by providing the right line for the right purpose. Depending on the type of cable, we can deliver in as fast as 4 6 weeks for a minimum quantity of 100 m. Just ask us. Our tailor-made range of products will win you over. T T 2

Contents Description Single Conductors TOPFLE 303 07V-K-YÖ,double insulation 0,6/1kV flexible PVC single core, oil resistant... TOPFLE 300,high flexible PVC single core, 0,6/1kV for drag chain and free move application... TOPFLE 1002,flexible double insulated single core 1000V... TOPFLE 302 / 302-UL,very high flexible PVC single core double insulated 0,6/1kV... TOPFLE 301 / 301-C,unscreened(double insulated)/ screened high flexible PUR single core 0,6/1kV for drag chain application... TOPFLE 304 / 304-C,unscreened(double insulated)/ screened high flexible PVC single core 0,6/1kV for drag chain application... GALVANICABLE,high-current cable, high flexible and halogen-free... Trailing Cables Flugzeugheber-T,trailing, PUR... BAULIFTKABEL B101 / B102 / B103,to be used at plant elevators... Cables for Photovoltaic Installations SOLARFLE - PV1-F... SOLARFLE - PV1-F TWIN... Cables for Wind Power Stations HELUWIND WK 103w-T, WK 103w EMC D-T,UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore... HELUWIND WK 103k-T, WK 103k EMC D-T,UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened,... HELUWIND WK 135-T, WK 135 D-EMC T,UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90 C (80 C acc. to UL), suitable for offshore. HELUWIND WK 137-T / WK 137 EMV D-TFT4,UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90 C, (80 C according to UL)... HELUWIND WK 300w-Torsion 1,8/3kV,UV-resistant... HELUWIND WK 305-Torsion 1,8/3kV,UV-resistant, suitable for offshore... HELUWIND WK H07BN4-F WIND-Torsion,Torsion +/- 150 /1m, UV-resistant, 750V/90 C... HELUWIND WK 101 H,0,6/1kV halogen-free... HELUWIND WK Fire Alarm Cable-Torsion,halogen-free, FT1, 24V... HELUWIND WK-NTSCGEWOEU-Torsion,3,6 / 6kV... HELUWIND WK DLO 2kV,FT4, UV-resistant, UL44 1kV, 90 C, VW-1, LS, MSHA... HELUWIND WK Powerline ALU 105 C robust,0,6/1kv or 1,8/3kV... HELUWIND WK THERMFLE 5,halogen-free, +5 C... HELUWIND WK (N)A2H,0,6/1kV, halogen-free... Sensor actuator and distributor Cables SENSORFLE,sensor actuator cable, PVC, PUR, PVC/PUR... VERTEILERFLE two-approvals,sensor actuator and distributor cables PVC, PUR, PVC/PUR... VERTEILERFLE, for sensor actuator distributor boxes, PVC, PUR or PVC/PUR... SENSORFLE-H,sensor actuator cables, halogen-free, high flexible drag chain cable, PUR, mantle EVA +125 C... Cables for airport 400 Hz AIRPORT 400 Hz,trailing, PUR, halogen-free, flame retardant... AIRPORT 400 Hz,trailing, PUR, halogen-free, flame retardant... Truck Cables HELUTRUCK 270,with ADR-approval, PVC low voltage cable for commercial vehicles... HELUTRUCK 271,with ADR-approval, PUR low voltage cable for commercial vehicles... HELUTRUCK 272 / 273,Flat cable for the sideways lighting with GGVS-authorization, Battery cable, battery charging cable... Page T 5 T 6 T 7 T 8 T 9 T 10 T 11 T 13 T T 18 T 19 T 27 T 28 T 29 T 30 T 31 T 32 T 33 T 34 T 35 T 36 T 37 T 38 T 39 T 40 T 42 T 43 T 45 T 46 T 49 T 50 T 52 T 53 T 54 T 3

TOPFLE 303 07V-K-Yö TOPFLE 300 TOPFLE 1002 TOPFLE 302 / 302-UL TOPFLE 301 / 301-C TOPFLE 304 / 304-C GALVANICABLE Single Conductors Photo: HELUKABEL These lines are specially designed for use as connecting cables in energy supply chains, handling equipment, robots, machine tools, and manufacturing and processing machines, and in almost all areas of flexible use with free movement. Optimised insulation materials ensure resistance to oil, greases, coolants, hydraulic liquids, as well as countless alkalis and solvents. Optimised exterior diameters, reduced weights, and outstanding torsion characteristics are the standout features of many of the single cores listed here. T T 4

TOPFLE 303 07V-K-YÖ double insulation 0,6/1kV flexible PVC single core, oil resistant Special PVC single-core cable with double insulation and oil-resistant sheath Temperature range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 600/1000 V A.C. test voltage, 50 Hz 3000 V Insulation resistance min. 20 MOhm/km Minimum bending radius for flexible installation 12 cable ø Bare copper, fine wire conductor to DINVDE0295 cl.5 and IEC608 cl.5 Special PVC core insulation, cold-resistant colour black / green-yellow Special PVC sheath, TM5 acc. to HD21.1S2/A16 Sheath colour grey These cables have been tested according to VDE207 and VDE0473 and found to be totally oil resistant PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodb) Improved mechanical protection due the double insulation This cable is used for conditions of increased mechanical stress. For flexible use with free movement without tensile stress or forced movements in dry, moist and wet environments, but not suitable for use outdoors. The cable may be laid in trays, troughs and channels. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. core-/sheath-color black/grey core-/sheath-color green-yellow/grey Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 75460 1x6 8,5 58,0 94,0 10 75449 1G6 8,5 57,6 94,0 10 75461 1x10 9,5 96,0 3,0 8 75469 1G10 9,5 96,0 3,0 8 75462 1x16 11,5 154,0 209,0 6 73859 1G16 11,5 154,0 209,0 6 75463 1x25,0 240,0 308,0 4 75470 1G25,0 240,0 308,0 4 75464 1x35 15,0 336,0 440,0 2 75471 1G35 15,0 336,0 440,0 2 75465 1x50 17,5 480,0 572,0 1 75472 1G50 17,5 480,0 572,0 1 75466 1x70 20,0 672,0 792,0 2/0 75473 1G70 20,0 672,0 792,0 2/0 75467 1x95,0 912,0 1155,0 3/0 75474 1G95,0 912,0 1155,0 3/0 72184 1x120 23,5 1152,0 1267,0 4/0 75475 1G120 23,5 1152,0 1267,0 4/0 72185 1x150 26,5 40,0 1650,0 300 kcmil 75476 1G150 26,5 40,0 1650,0 300 kcmil 75468 1x185 29,0 1776,0 2134,0 350 kcmil 75477 1G185 29,0 1776,0 2134,0 350 kcmil 741 1x240 31,0 2304,0 2943,0 500 kcmil 75478 1G240 31,0 2304,0 2943,0 500 kcmil 72082 1x300 35,0 2880,0 3600,0 600 kcmil 75479 1G300 35,0 80,0 3600,0 600 kcmil T 5

TOPFLE 300 high flexible PVC single core, 0,6/1kV for drag chain and free move application Special PVC single-core cable with oil-resistant insulation based on DINVDE0281 part13 and in accordance with HD21.13S1 Temperature range flexing -5 C to +80 C fixed installation -40 C to +80 C Nominal voltage U0/U 600/1000 V A.C. test voltage, 50 Hz 3000 V Insulation resistance min. 20 MOhm/km Minimum bending radius for flexible installation 7,5 cable ø Bare copper, extra fine wire conductor to DINVDE0295 cl.6 and IEC608 cl.6 Oil-resistant special PVC insulation Colour see table, or as desired If this cable is to be double-insulated, then its external diameter and weight must be adapted. Caution with existing cables. PVC self-extinguishing and flame retardant, test method B according to VDE0472 part804 and IEC60332-1 Chemical resistance see table Technical Information Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling devices, robots, and nearly any area requiring flexible used and free motion. Due to its resistance to mineral oils these cables are well suited for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly critical areas. Suitable for installation in dry, damp and wet environments. With the black sheath, can also be used outdoors. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. TOPFLE 300 black TOPFLE 300 green-yellow Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 79623 1x2,5 4,2 24,0 42,0 79627 1G2,5 4,2 24,0 42,0 79624 1x4 5,1 38,4 58,0 12 79628 1G4 5,1 38,4 58,0 12 79625 1x6 6,0 57,6 85,0 10 79629 1G6 6,0 57,6 85,0 10 79626 1x10 7,4 96,0 130,0 8 79630 1G10 7,4 96,0 130,0 8 75431 1x16 8,8 154,0 210,0 6 75438 1G16 8,8 154,0 210,0 6 75432 1x25 10,7 240,0 300,0 4 75439 1G25 10,7 240,0 300,0 4 75433 1x35 12,1 336,0 420,0 2 75440 1G35 12,1 336,0 420,0 2 70519 1x50,0 480,0 580,0 1 70536 1G50,0 480,0 580,0 1 75434 1x70 16,3 672,0 780,0 2/0 75441 1G70 16,3 672,0 780,0 2/0 737 1x95 18,3 912,0 1010,0 3/0 75442 1G95 18,3 912,0 1010,0 3/0 75435 1x120 20,0 1152,0 1200,0 4/0 73885 1G120 20,0 1152,0 1200,0 4/0 75436 1x150 23,0 40,0 1600,0 300 kcmil 75443 1G150 23,0 40,0 1600,0 300 kcmil 72872 1x185 24,8 1776,0 2030,0 350 kcmil 75444 1G185 24,8 1776,0 2030,0 350 kcmil 75437 1x240 28,7 2304,0 2600,0 500 kcmil 75445 1G240 28,7 2304,0 2600,0 500 kcmil TOPFLE 300 red Part no. No.cores x 79631 1x2,5 79632 1x4 79633 1x6 79634 1x10 78106 1x16 78107 1x25 78108 1x35 70518 1x50 78109 1x70 78110 1x95 78111 1x120 Outer Ø Cop. mm weight kg/km 4,2 24,0 5,1 38,4 6,0 57,6 7,4 96,0 8,8 154,0 10,7 240,0 12,1 336,0,0 480,0 16,3 672,0 18,3 912,0 20,0 1152,0 Weight kg/km 42,0 58,0 85,0 130,0 210,0 300,0 420,0 580,0 780,0 1010,0 1200,0 AWG-No. 12 10 8 6 4 2 1 2/0 3/0 4/0 TOPFLE 300 blue Part no. No.cores x 79635 1x2,5 79636 1x4 79637 1x6 79638 1x10 78112 1x16 78113 1x25 781 1x35 78115 1x50 78116 1x70 78117 1x95 73884 1x120 Outer Ø Cop. mm weight kg/km 4,2 24,0 5,1 38,4 6,0 57,6 7,4 96,0 8,8 154,0 10,7 240,0 12,1 336,0,0 480,0 16,3 672,0 18,3 912,0 20,0 1152,0 Weight kg/km 42,0 58,0 85,0 130,0 210,0 300,0 420,0 580,0 780,0 1010,0 1200,0 AWG-No. 12 10 8 6 4 2 1 2/0 3/0 4/0 T T 6

TOPFLE 1002 flexible double insulated single core 1000V Special PVC single-core cable with double insulation approved to ULAWM Style1032 Temperature range flexing -5 C to +90 C fixed installation -40 C to +90 C Nominal voltage acc. to VDE U0/U 600/1000 V acc. to UL 1000 V A.C. test voltage, 50 Hz 4000 V Insulation resistance min. 20 MOhm x km Minimum bending radius for flexible installation 7,5x cable ø for fixed installation 3x cable ø Bare copper conductor, fine wire stranded 1st insulation: special PVC, black colour 2nd insulation: special PVC Sheath colour black PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodb) PVC single-core cable suitable for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms, and in open air (fixed installation). Must not be installed directly in the ground or water. This two-approvals single-core cable is preferred for use in export-oriented mechanical engineering, in machine tools, production lines and systems engineering. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x 1x1,5 1x2,5 1x4 1x6 1x10 1x16 AWG-No. Outer Ø mm Cop. weight kg/km Weight kg/km 30,0 49,0 75,0 118,0 180,0 250,0 Part no. No.cores x 1x25 1x35 1x50 1x70 1x95 1x120 AWG-No. Outer Ø mm Cop. weight kg/km Weight kg/km 701377 16 4,5,4 701381 4 11,6 240,0 370,0 701378 5,0 24,0 701382 2 13,0 336,0 490,0 701379 12 6,1 38,4 701383 1 16,0 480,0 665,0 700160 10 7,2 57,6 701384 2/0 17,1 672,0 910,0 701380 8 9,0 96,0 701387 3/0 19,5 912,0 1195,0 700159 6 10,2 154,0 701388 4/0,3 1152,0 1545,0 T 7

TOPFLE 302 / 302-UL very high flexible PVC single core double insulated 0,6/1kV TOPFLE 302 Bare copper, extra fine wire conductor to Sheath UV-resistant Special PVC single-core cable with double insulation flexible at low temperatures DINVDE0295 cl.6 and IEC608 cl.6 PVC insulation flexible at low temperatures, PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN Temperature range natural colour 60332-1-2/ IEC60332-1 (equivalent flexing -15 C to +80 C PVC sheath compound TM2 flexible at low DINVDE0472 part804 test methodb) fixed installation -40 C to +80 C temperatures Chemical resistance see table Technical Nominal voltage U0/U 600/1000 V Sheath colour black, UV-resistant Information A.C. test voltage, 50 Hz 3000 V Insulation resistance min. 20 MOhm x km Minimum bending radius for flexible installation 5x cable diameters TOPFLE 302-UL as above, but with additional UL Approval Style 10107 Nominal voltage UL 1000 V The cable is permissible for overvoltage category II These cables are specially designed for use as connecting cables on sliding contacts for current collectors, and also for use in energy supply chains, automatic handling devices, robots, machine tools, machining and processing equipment, and nearly any area requiring flexible used and free motion. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. TOPFLE 302 without UL-approval TOPFLE 302 with UL-approval Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x AWG-No. Outer Ø Cop. Weight mm weight kg/km kg/km mm weight kg/km kg/km 72946 1x1,5 4,0,4 25,0 16 700231 1x1,5 16 5,2,4 25,0 73924 1x2,5 4,5 24,0 42,0 700232 1x2,5 6,4 24,0 42,0 72950 1x4 5,6 38,4 58,0 12 700233 1x4 12 7,0 38,4 58,0 72945 1x6 6,1 57,6 85,0 10 700234 1x6 10 7,5 57,6 85,0 75450 1x10 8,0 96,0 130,0 8 701351 1x10 8 9,1 96,0 130,0 72947 1x16 9,8 153,6 190,0 6 7001 1x16 6 10,8 153,6 190,0 75451 1x25 11,8 240,0 280,0 4 701352 1x25 4 13,1 240,0 280,0 75452 1x35 12,9 336,0 400,0 2 701353 1x35 2,1 336,0 400,0 75453 1x50,6 480,0 520,0 1 701354 1x50 1 15,8 480,0 520,0 72944 1x70 17,5 672,0 720,0 2/0 700235 1x70 2/0 19,0 672,0 720,0 75454 1x95 20,2 912,0 1050,0 3/0 701355 1x95 3/0 21,5 912,0 1050,0 75455 1x120 21,6 1152,0 10,0 4/0 701356 1x120 4/0 23,2 1152,0 10,0 75456 1x150 23,5 40,0 1500,0 300 kcmil 701357 1x150 300 kcmil 25,2 40,0 1500,0 75457 1x185 25,7 1776,0 1940,0 350 kcmil 701358 1x185 350 kcmil 27,0 1776,0 1940,0 75458 1x240 29,5 2304,0 2675,0 500 kcmil 701359 1x240 500 kcmil 31,5 2304,0 2675,0 T T 8

TOPFLE 301 / 301-C unscreened(double insulated)/ screened high flexible PUR single core 0,6/1kV for drag chain application TOPFLE 301 (unscreened) Special PUR single-core cable acc. to ULAWM Style10553 Temperature range flexing -15 C to +80 C Nominal voltage acc. to VDE U0/U 600/1000 V acc. to UL 1000 V A.C. test voltage 3000 V Insulation resistance min. 20 MOhm x km Minimum bending radius 7,5 cable ø TOPFLE 301C (screened) Tech. data as per TOPFLE 301 Coupling resistance max. 250 Ohm/km TOPFLE 301 (unscreened) Bare copper, extra fine wire conductor to DINVDE0295 cl.6 and IEC608 cl.6 PVC core insulation flexible at low temperatures, grey PUR sheath Colour black or green-yellow TOPFLE 301C (screened) Structure as per TOPFLE 301, but additionally Fleece wrapping between screen and sheath Tinned copper braided screening, 85% coverage Sheath colour black PUR outer sheath: low adhesion, flame retardant, extremely abrasion resistant, resistant to UV, oil, hydrolysis and microbial attack Optimised insulation materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents The optimised external diameter and the reduced weight facilitate use in multi-shift operation with extreme alternating bending stress cycles Thanks to its excellent mechanical characteristics, the wear-resistant, notch-resistant, flame-retardant PUR sheath provides high functional reliability over long periods TOPFLE 301 (unscreened) These cables are specially designed for use in energy supply chains, automated handling equipment, robots, machine tools, processing and manufacturing machinery. TOPFLE 301C (screened) s as described above, additionally optimal compliance with electromagnetic compatibility (EMC) requirements on account of the 85% coverage by the braided screening. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. TOPFLE 301 double insulated, black unscreened TOPFLE 301C black screened EMC Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 75375 1x6 7,1 58,0 85,0 10 75399 1x6 7,8 95,0 4,0 10 75376 1x10 8,8 96,0 130,0 8 75400 1x10 9,5 124,0 170,0 8 75377 1x16 10,5 154,0 190,0 6 75401 1x16 10,8 186,0 0,0 6 75378 1x25 11,2 240,0 280,0 4 75402 1x25 12,2 278,0 340,0 4 75379 1x35 13,5 336,0 400,0 2 75403 1x35 13,7 384,0 460,0 2 75380 1x50 15,8 480,0 520,0 1 75404 1x50 15,4 530,0 580,0 1 75381 1x70 18,0 672,0 720,0 2/0 75405 1x70 17,6 753,0 820,0 2/0 75382 1x95 20,4 912,0 1050,0 3/0 75406 1x95 21,7 1006,0 1200,0 3/0 75383 1x120,2 1152,0 10,0 4/0 75407 1x120,4 1257,0 1350,0 4/0 75384 1x150 25,0 40,0 1500,0 300 kcmil 75408 1x150 24,3 1562,0 1680,0 300 kcmil 75385 1x185 28,0 1776,0 1940,0 350 kcmil 75409 1x185 26,5 1895,0 2100,0 350 kcmil 75386 1x240 32,5 2304,0 2645,0 500 kcmil 75410 1x240 30,3 2704,0 3100,0 500 kcmil TOPFLE 301 double insulated, green-yellow unscreened Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km 75387 1G6 7,1 58,0 85,0 10 75388 1G10 8,8 96,0 130,0 8 75389 1G16 10,5 154,0 190,0 6 75390 1G25 11,2 240,0 280,0 4 75391 1G35 13,5 336,0 400,0 2 75392 1G50 15,8 480,0 520,0 1 75393 1G70 18,0 672,0 720,0 2/0 75394 1G95 20,4 912,0 1050,0 3/0 75395 1G120,2 1152,0 10,0 4/0 75396 1G150 25,0 40,0 1500,0 300 kcmil 75397 1G185 28,0 1776,0 1940,0 350 kcmil 75398 1G240 32,5 2304,0 2645,0 500 kcmil T 9

TOPFLE 304 / 304-C unscreened(double insulated)/ screened high flexible PVC single core 0,6/1kV for drag chain application Special PVC single-core cable TOPFLE 304 Temperature range Bare copper, extra fine wire conductor to flexing -5 C to +80 C DINVDE0295 cl.6 and IEC608 cl.6 fixed installation -40 C to +80 C PVC insulation, green-yellow Nominal voltage U0/U 600/1000 V PVC sheath compound TM2 A.c. test voltage, 50 Hz Sheath colour grey 3000 V TOPFLE 304C Insulation resistance Construction as above, but min. 20 MOhm x km Tinned copper braid, coverage 85% Minimum bending radius for flexible installation 5x cable ø PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodb) Chemical resistance see table Technical Information Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling devices, robots, and nearly any area requiring flexible used and free motion. TOPFLE 304C Optimum compliance with requirements for electromagnetic compatibility (EMC) by 85% coverage from the braided screen. EMC = Electromagnetic compatibillity To optimise the EMC features we recommend a large round contact of the copper braiding on both ends. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. TOPFLE 304 TOPFLE 304C Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 79639 1G2,5 4,5 24,0 42,0 79653 1G2,5 5,9 40,0 55,0 79640 1G4 5,6 38,4 58,0 12 79654 1G4 6,5 50,0 75,0 12 79641 1G6 6,1 57,6 85,0 10 79655 1G6 8,3 88,0 125,0 10 71544 1G10 8,0 96,0 130,0 8 79656 1G10 8,7 124,0 170,0 8 79642 1G16 9,8 154,0 190,0 6 79657 1G16 10,3 190,0 300,0 6 79643 1G25 11,8 240,0 280,0 4 79658 1G25 12,4 260,0 420,0 4 79644 1G35 12,9 336,0 400,0 2 79659 1G35 13,7 405,0 620,0 2 79645 1G50,6 480,0 520,0 1 79660 1G50 15,4 560,0 825,0 1 79646 1G70 17,5 672,0 720,0 2/0 79661 1G70 17,5 780,0 1090,0 2/0 79647 1G95 20,0 912,0 1050,0 3/0 79662 1G95 21,0 1030,0 1395,0 3/0 79648 1G120 21,6 1152,0 10,0 4/0 79685 1G120,4 1311,0 1770,0 4/0 79649 1G150 23,5 40,0 1500,0 300 kcmil 79663 1G150 24,3 1527,0 1930,0 300 kcmil 79650 1G185 25,7 1776,0 1940,0 350 kcmil 79664 1G185 26,5 1940,0 2635,0 350 kcmil 79651 1G240 29,5 2304,0 2675,0 500 kcmil 79665 1G240 30,3 2530,0 3380,0 500 kcmil 79652 1G300 32,5 2880,0 3300,0 600 kcmil 79666 1G300 35,0 3050,0 3500,0 600 kcmil T T 10

GALVANICABLE high-current cable, high flexible and halogen-free Temperature range flexing -40 C to +80 C fixed installation -50 C to +80 C Operating voltage U0/U 600/1000 V Test voltage 3500 V Insulation resistance min. 20 MOhm/km Minimum bending radius 15x cable ø Bare copper, ultra-fine wire conductors acc. to DINVDE0295 cl.6 and IEC608 cl.6 Extremely thick PUR wearing sheath Natural colour, smooth, glossy PUR wearing sheath: extremely abrasion resistant, halogen-free, resistant to UV, oil, hydrolysis and microbial attack Chemical resistance: PUR demonstrates significantly better chemical resistance when compared with other materials, e.g. rubber or PVC The extremely thick PUR sheath means longer service life This cable is employed as a highly-flexible high-current cathode cable for electroplating drum systems and as a wearing cable in the chemical industry. Special feature: Despite the extremely thick wearing sheath, the highly flexible conductor enables good contact when installing the pear push. Good flexibility is likewise ensured when the pear push comes into contact with the parts to be electroplated. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 700768 1x35 17,2 336,0 548,0 2 74749 1x120 27,0 1152,0 1520,0 4/0 75497 1x50 19,0 480,0 686,0 1 700769 1x150 28,0 40,0 2002,0 300 kcmil 75498 1x70 21,5 672,0 950,0 2/0 700770 1x185 30,5 1776,0 2610,0 350 kcmil 75499 1x95 24,0 912,0 1386,0 3/0 700771 1x240 36,0 2304,0 3820,0 500 kcmil T 11

Flugzeugheber-T BAULIFTKABEL B101 / B102 / B103 Trailing Cables Photo: HELUKABEL Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and torsional stress. Trailing cables are frequently used in building machinery, conveyors and lifting systems, and cranes. T T 12

Flugzeugheber-T trailing, PUR Temperature range flexing -20 C to +80 C Nominal voltage control cores 300/500 V power supply cores 0,6/1 kv A.C. test voltage, 50 Hz control cores 1500 V power supply cores 4000 V Minimum bending radius for flexible installation 15x cable ø Part no. 70736 PUR outer sheath: low adhesion, flame Bare copper, extra fine wire conductor to retardant, extremely abrasion resistant, DINVDE0295 cl.6 and IEC608 cl.6 halogen-free, resistant to UV, oil, hydrolysis Polyethylene core insulation DIN and microbial attack 47100/0.34 PUR-jacket flame retardant according to Core insulation: special PVC, flexible at low DINVDE0482 part265-2-1/ EN50265-2-1/ temperatures, black with number 6-20/0,75 IEC60332-1 (equivalent DINVDE0472 and number 1-5/4 part804 test methodb) 0,34 cores stranded in pairs and screened with doubled copper braid Inner sheath of special PVC flexible at low temperatures Cores stranded with elements Inner sheath of special PVC flexible at low temperatures over cores PUR outer sheath with embedded support braiding Sheath colour grey RAL 7001 Part no. 77548 Bare copper, extra fine wire conductor to DINVDE0295 cl.6 and IEC608 cl.6 Core insulation TPE-E, black with number +gnye/1 and 2,5 Polypropylene core insulation, colour code DIN 47100/0,34 0,34 cores stranded in a pair Pairs screened with aluminium-coated polyester foil and tinned copper braiding Cores and pairs stranded PUR outer sheath with embedded support braiding Sheath colour orange RAL 2003 This hybrid cable is designed for the aircraft industry, and contains cores for power supply, control cores, and cores for a positioning laser. The cable is used to control and position a support robot, which absorbs loads at specific points when loading extremely heavy items, for example during loading of aircraft assemblies in large transport aircraft of the Airbus industry. The cable is trailing, UV and weather-resistant, and is provided with an extremely wear-resistant and petrol-resistant special sheath. Part no. 77548 is designed for similar applications, as a load-reducing lifter in aircraft assembly. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 70736 5x 4+ 5x 3G0,75 + 2 x 2 x 0,34 25,6 390,0 600,0 12 77548 5x 2,5+ 18G1,0+ 4x 2x 0,34 27,0 461,0 750,0 T 13

BAULIFTKABEL B101 / B102 / B103 to be used at plant elevators Temperature range flexing -10 C to +80 C Nominal voltage control cores 300/500 V power supply cores 0,6/1 kv A.c. test voltage, 50 Hz control cores 1500 V power supply cores 3000 V Minimum bending radius 10x cable diameters Bare copper wire, highly flexible Core insulation of plastic, flexible at low temperatures, with number and gnye Sheath of special plastic, flexible at low temperatures, black Optional separate copper screening of the control cores Sheath UV-resistant In carriage version with special support braiding and with PUR sheath particularly resistant to wear, oil, hydrolysis and microbial attack These hybrid cables are used for power supply and control of vertical lifts in the construction industry. There are 3 cable versions. B101: Here the cable is drawn vertically from a drum as a drag cable via the load platform. The load platform pulls the cable along as it moves up. During the downwards motion the cable returns to the drum automatically. Our special versions are used at heights of up to about 150 m. B102: For greater heights, a so-called carriage version is employed, in which the cable is fed at the centre of the tower, i.e. half the way up. B103: Here the cable is guided via a spring-loaded drum. These vertical construction lifts are used during new construction and renovation work on high buildings. The rack lattice elements are fastened at intervals to the exterior facade. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. BAULIFTKABEL B101 BAULIFTKABEL B102 Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 73519 5x 2,5+ 10G1,0 20,0 0,0 306,0-74293 4x 16+ 1G2,5+ 2x 2x 1,0 28,5 830,0 1080,0 6 73913 5x 2,5+ 11G1,0 20,0 5,6 320,0 74670 4x 16+ 1G2,5+ 2x 2x 1,0 28,5 787,0 1080,0 6 70402 3x 4+ 7G1,0 17,4 184,0 360,0 12 74297 4x 25+ 1G2,5+ 2x 2x 1,0 33,4 1176,0 1500,0 4 70931 4x 6+ 9G1,0 20,5 330,0 555,0 10 781 4x 35+ 4G2,5+ 2x 2x 1,0+ 1 38,0 1500,0 1850,0 2 70377 4x 6+ 10G1,0 21,0 340,0 575,0 10 x 1,0 71901 4x 6+ 15G1,0,0 388,0 625,0 10 71369 4 x 10 + 10G1,0 25,0 480,0 870,0 8 BAULIFTKABEL B103 78123 4x 16+ 6G1,0 26,1 700,0 1250,0 6 Part no. No.cores x Outer Ø Cop. Weight AWG-No. 78124 4 x 16 + 10G1,0 29,0 710,0 1300,0 6 weight 78125 4 x 16 + 15G1,0 31,5 760,0 1380,0 6 mm kg/km kg/km 73726 4x 16+ 1G2,5+ 4x 1,0 28,5 830,0 60,0 6 77532 4x 2,5+ 3G1,0 13,0 125,0 230,0 77538 4x 2,5+ 3G1,0 15,3 125,0 280,0 T T

Photo: HELUKABEL Cables & Wires for Renewable Energies T 15

SOLARFLE - PV1-F SOLARFLE - PV1-F Twin Cables for Photovoltaic Installations Photo: HELUKABEL T T 16

Contents Description Page SOLARFLE - PV1-F... T 18 SOLARFLE - PV1-F TWIN... T 19 T 17

SOLARFLE - PV1-F Temperature range -40 C to +90 C Max.Temp. at conductor +120 C Nominal voltage According to VDE 600/1000 V AC 1800 V DC conductor/conductor AC test voltage 10000 V Minimum bending radius fixed installation 4 x outer diameters flexing 10 x cable diameter The SOLARFLE - PV1-F is used for cabling solar modules. Part no. 7045 705892 705891 7046 705776 705775 7047 705778 705777 7048 705894 705893 7049 706840 706839 704230 704231 704232 704233 704234 705738 705739 706288 706289 No.cores x 1x2,5 1x2,5 1x2,5 1x4 1x4 1x4 1x6 1x6 1x6 1x10 1x10 1x10 1x16 1x16 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 Jacket colour black blue red black blue red black blue red black blue red black blue red black black black black black black black black black Bare copper, tinned, finely stranded Ozone resistant acc. to EN 50396 according to DIN VDE 0295 class 5 and IEC Weather und UV resistant acc. to HD 605/A1 608 cl. 5 Halogen-free acc. to EN 50267-2-1, EN Double-insulated 60684-2 Insulation cross-linked Polyolefin Resistant to acid and bases acc. to EN Outer sheath cross-linked Polyolefin 60811-2-1 Sheath colour black, red or blue Flame-resistant acc. to VDE 0482-332-1-2, Approvals DIN EN 60332-1-2, IEC 60332-1 According to PV1-F requirement profile for Very robust and abraison-resistant sheath PV cable DKE/VDE AK 411.2.3 acc. to DIN EN 53516 VDE (Reg. 8266) Resistant to short-circuits up to 200 C TÜV (2 PfG 1169/08.2007, R60025298) thanks to their double insulation; RoHS and CE compliant short-circuits temperature 200 C / 5sec. UL certification in progress (UL Subject Anticipated service life - 25 years 4703) Hydrolysis and ammoniac resistant Note Not for direct installation in ground Version with rodent protection available: Solarflex- PV1-F NTS (V2A braiding) All types with metre marking Outer Ø mm 4,5 4,5 4,5 5,2 5,2 5,2 5,9 5,9 5,9 6,9 6,9 6,9 8,3 8,3 8,3 10,0 11,0 13,0 15,3 17,0 19,1,7 25,5 28,3 Cop. weight kg/km 24,0 24,0 24,0 38,4 38,5 38,4 57,6 57,6 57,6 96,0 96,0 96,0 153,6 153,6 153,6 240,0 336,0 480,0 672,0 912,0 1152,0 40,0 1776,0 2304,0 Weight kg/km 42,0 42,0 42,0 60,0 60,0 60,0 82,0 82,0 82,0 123,0 123,0 123,0 190,0 190,0 190,0 285,0 376,0 530,0 745,0 960,0 10,0 1550,0 1930,0 2550,0 AWG-No. T T 18

SOLARFLE - PV1-F TWIN Temperature range -40 C to +90 C Max. temp. at conductor +120 C Nominal voltage According to VDE U0/U 600/1000 V AC 1800 V DC conductor/conductor AC test voltage 6500 V, 50 Hz, 15 kv DC Minimum bending radius Single 1,5 cable diameters Multiple 10 cable diameters The SOLARFLE - PV1-F TWINis used for cabling solar modules. Part no. No.cores x 2x2,5 2x4 Outer Ø Cop. min. - max. weight mm kg/km 5,4-11,0 50,0 5,8-11,8 80,0 Bare copper, Class 5, tinned, finely stranded according to DIN VDE 0295 class 5 and IEC 608 cl. 5 Double-insulated Insulation cross-linked special Polyolefin Outer sheath cross-linked special Polyolefin Sheath colour: black Weight kg/km 106,0 2,0 AWG-No. Part no. No.cores x 2x6 2x10 Approval: TÜV 2Pfg 1169/08.2007 UV-, ozone-resistant, weather-resistant Halogen-free Abrasion and cut resistant Relatively flexible Easy to strip Flame-resistant according to VDE 0482 Part 332-1-2, IEC 60332-1-2 Resistant to short circuits up to 200 C thanks to double insulation, short circuit temperature 200 C/5 sec. Anticipated service life 25 years Note Cross-sections up to 2 x 16 are available on request Outer Ø Cop. min. - max. weight mm kg/km 6,8-13,6 120,0 7,8-15,8 200,0 Weight kg/km 182,0 254,0 AWG-No. 707234 705769 10 707235 12 707236 8 T 19

HELUWIND WK 103w HELUWIND WK 103k HELUWIND WK 135-Torsion HELUWIND WK 137-Torsion HELUWIND WK 300w-Torsion HELUWIND WK 305-Torsion HELUWIND WK H07BN4N4-F WIND-Torison HELUWIND WK 101 H HELUWIND WK fire warning cable Torsion HELUWIND WK-NTSCGEWOEU-Torsion HELUWIND WK DLO 2kV HELUWIND WK Powerline ALU HELUWIND Thermflex 5 HELUWIND WK (N)A2H Cables for Wind Power Stations Photo: HELUKABEL T T 20

Contents Description Page Functional view of Wind Power Station... T Selection table Cables & Wires... T 23 HELUWIND WK 103w-T, WK 103w EMV D-T UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore... T 27 HELUWIND WK 103k-T, WK 103k EMV D-T UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened... T 28 HELUWIND WK 135-T, WK 135 D-EMV T UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90 C (80 C nach UL), suitable for offshore... T 29 HELUWIND WK 137-T / WK 137 EMV D-T FT4 UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90 C (80 C according to UL) T 30 HELUWIND WK 300w-Torsion 1,8/3kV UV-resistant... T 31 HELUWIND WK 305-Torsion 1,8/3kV UV-resistant, suitable for offshore... T 32 HELUWIND WK H07BN4-F WIND-Torsion Torsion +/- 150 /1m, UV-resistant, 750V/ 90 C... T 33 HELUWIND WK 101 H 0,6/1kV halogen-free... T 34 HELUWIND WK Fire Alarm Cable-Torsion halogen-free, FT1, 24V... T 35 HELUWIND WK NTSCGEWOEU-Torsion 3,6 / 6kV... T 36 HELUWIND WK DLO 2kV FT4, UV-resistant, UL44 1kV, 90 C, VW-1, LS, MSHA... T 37 HELUWIND WK Powerline ALU 105 C robust 0,6/1kV oder 1,8/3kV... T 38 HELUWIND WK THERMFLE 5 halogen-free, +5 C... T 39 HELUWIND WK (N)A2H 0,6/1kV halogen-free... T 40 T 21

Functional view of Wind Power Station Rotor blade Gearbox Brake Pod Generator Wind-direction tracking Rotor hub & blade adjustment Tower Cables and wires for use in: Pod Cable loop Tower Tower control / transformer Base of tower Tower control / transformer Base Medium-high voltage level T T

Selection table Cables & Wires Torsion Cables Usage, see chart on page T UL-Style CSA CE VDE* fire tests FT4 fire tests FT1 (with FT2) nominal voltage according to UL nominal voltage according to VDE halogen-free oil resistant II** oil resistant I UV-resistant offshore employment temp. non-flexing from (in C) temp. non-flexing to (in C) temp. flexing from (in C) temp. flexing to (in C) twistable +/- 150 per meter twistable +/- 0 per meter twistable +/- 90 per meter can be found on page WK 103w-T 10678 0,6/ cruus 1000V 21179 1kV (*) -40 +90-35 +90 T 27 WK 103w EMV D-T 10678 0,6/ cruus 1000V 21179 1kV (*) -40 +90-35 +90 T 27 WK 103k-T 10269 2570 cruus 1000V 0,6/ 1kV -40 +80-40 +80 T 28 WK 103k EMV D-T 10269 2570 cruus 1000V 0,6/ 1kV -40 +80-40 +80 T 28 WK 135-T 10553 20234 cruus 60332-3 1000V 0,6/ 1kV -40 +90-40 +90 T 29 WK 135 EMV D-T 10553 20234 cruus 60332-3 1000V 0,6/ 1kV -40 +90-40 +90 T 29 WK 137-T FT4 10553 20234 cruus 1000V 0,6/ 1kV -40 +90-40 +90 T 30 WK 137 EMV D-T 10553 20234 cruus 1000V 0,6/ 1kV -40 +90-40 +90 T 30 WK 300w-T 1,8/ 3kV -40 +90-35 +90 T 31 WK 305-T 60332-3 1,8/ 3kV -40 +90-40 +90 T 32 WK H07BN4-F WIND-T 450/ 750V -45 +90-35 +90 T 33 WK 101 H 0,6/ 1kV -50 +100-40 +90 T 34 WK Fire Alarm Cable-T 24V -50 +90-40 +80 +/- 215 T 35 WK NTSCGEWOEU-T 3,6/ 6kV -40 +90-40 +90 +/- 100 T 36 WK DLO 2kV UL 44 2000V -40 +90 T 37 WK Powerline ALU 60332-3 0,6/ 1kV -40 +105-20 +105 T 38 WK Thermflex 5 0,6/ 1kV -55 +5-20 +120 T 39 WK (N)A2H 60332-3 0,6/ 1kV -30 +90-5 +50 T 40 *in preparation ** in accordance with UL 1277, Table 11.2 for multi-core types T 23

Selection table Cables & Wires Control Cables Usage, see chart on page T UL-Style CSA CE HAR with VDE Reg.-No. FT1 equivalent to IEC 60332-1 nominal voltage according to UL nominal voltage according to VDE halogen-free oil resistant II UV-resistant temp. non-flexing from (in C) temp. non-flexing to (in C) temp. flexing from (in C) temp. flexing to (in C) Cu-Shield can be found on page JZ-500 300/ 500V -40 +80-15 +80 A 6 F-CY-JZ 300/ 500V -40 +80-40 +80 A 27 Y-CY-JZ 300/ 500V -40 +80-5 +80 A 32 JZ-500 HMH JZ-500 HMH-C 60332-3 300/ 500V -40 +70-15 +70 A 62 A 71 MEGAFLE 500 MEGAFLE 500-C 60332-3 300/ 600V 300/ 500V -40 +80-30 +90 A 64 A 73 JZ-600 JZ-600-Y-CY 0,6/ 1kV -40 +80-5 +80 A 16 A 36 Single 600-J/-O Single 600-CY -J/-O 600 V 0,6/ 1kV -40 +90-5 +90 N 120 N 121 JZ-600 HMH JZ-600 HMH-C 60332-3 0,6/ 1kV -40 +70-15 -5 +70 A 66 A 75 JZ-600-UL/CSA JZ-600-Y-CY-UL/CSA 1kV 0,6/ 1kV black -40 +80-5 +80 N 10 N 20 JZ-602 JZ-602-CY 600V -40 +90-5 +90 N 7 N 17 JZ-603 JZ-603-CY 600V 300/ 500V -40 +70-5 +70 N 9 N 19 H07RN-F H07RN-F/SOOW 600V 450/ 750V -40 +90 F 6 N 80 HELUTHERM 5 MULTI HELUTHERM 5 MULTI-C 60332-3 300/500V to 1,0 mm 2 450/750V -55 +5-35 +120 from 1,5 mm 2 E 5 E T T 24

Selection table Cables & Wires Data Cables Usage, see chart on page T UL-Style CSA CE HAR with VDE Reg.-No. FT1 equivalent to IEC 60332-1 nominal voltage according to UL nominal voltage according to VDE halogen-free oil resistant II UV-resistant temp. non-flexing from (in C) temp. non-flexing to (in C) temp. flexing from (in C) temp. flexing to (in C) Cu-Shield can be found on page TRONIC-CY PAAR-TRONIC-CY 350/ 500V -40-30 +80-5 +80 B 9 B 11 DATAFLAMM DATAFLAMM-C 350/ 500V -40 +70-5 +70 B 8 B 23 DATAFLAMM-C-PAAR 350/ 500V -40 +70-5 +70 B 24 LiYY-UL LiYY-TP-UL 300V -20 +80-10 +80 N 65 N 67 SUPERTRONIC -PURö SUPERTRONIC -C-PURö 350V -40 +70-5 +70 C 33 C 34 SUPERTRONIC -330 PURö SUPERTRONIC -330-C-PURö 300V 300V -50 +80-40 +80 N 102 N 103 SUPER-PAAR-TRONIC-C-PUR SUPER-PAAR-TRONIC 340-C-PUR 300V 350V -50 +70-40 +70 C 35 N 104 Single Conductors H07 V-K/(H)07 V-K H05Z-K/H07Z-K -30-40 +80 +90-5 +70 K 8 K 16 FIVENORM -40-55 +90 +5-5 -35 +90 +120 N 113 HELUTHERM 5 600V HELUTHERM 5 600V UL -55 +125-35 +120 K N 118 TC TRAY CABLES UL/CSA TRAYCONTROL 300 FT4 300-25 +105-25 +105 N 38 TRAYCONTROL 300-C FT4 300-25 +105-25 +105 N 40 TRAYCONTROL 300-C TP FT4 300-25 +105-25 +105 N 44 TRAYCONTROL 500 1277 FT4 1000-40 +90-5 +90 N 27 TRAYCONTROL 500-C 1277 FT4 1000-40 +90-5 +90 N 35 JZ-604 TC TRAY CABLE 1277 FT4 600-25 +90-5 +90 N 25 JZ-604-YCY TC TRAY CABLE 1277 FT4 600-25 +90-5 +90 N 34 T 25

Selection table Cables & Wires TC TRAY CABLES UL/CSA Usage, see chart on page T UL-Style CSA CE HAR with VDE Reg.-No. FT1 equivalent to IEC 60332-1 nominal voltage according to UL nominal voltage according to VDE halogen-free oil resistant II UV-resistant temp. non-flexing from (in C) temp. non-flexing to (in C) temp. flexing from (in C) temp. flexing to (in C) Cu-Shield can be found on page TRAYCONTROL 600 1277 FT4 1000-40 +90-5 +90 N 30 Communication Cables Industrial Ethernet 105 C Industrial Ethernet S-FTP TORDIERFLE BUS Cable HELUWIND WK CAN BUS 105 C 60332-1 300V 100V -40 +105-40 +105 R 94 60332-1 300V 100V -20 +80-20 +80 R 99 600V 100V -40 +105-20 +60 R 133 BUS Cable indoor Profibus SK outdoor _ 600V _ 100V 100V -40-40 +70 +70-5 -5 +60 +60 R 118 BUS Cable Torsion Profibus L2 industry _ CM _ 300V _ 100V 100V -40-40 +75 +70-25 -5 +75 +60 R 1 AT-V(ZN)Y(ZN)Y AT-V(ZN)H(ZN)11Y submitted _ submitted _ FT4 submitted _ -40-40 +90 +90-40 -40 +90 +90 R 36 Fibre Optic Cable mobile, trailing A-V(ZN)11Y 60332-1 -30 +70-20 +70 R 34 Fibre Optic Cable mobile A-V(ZN)Y FT4-30 +80-20 +80 R 35 Fibre Optic Breakoutcable Industry HCS I-V(ZN)YY FT4-30 +85-20 +85 R 44 LWL-Breakoutkabel Industrie HCS I-V(ZN)Y11Y -20 +80-20 +80 R 41 Plastic-fibre Optic cable industry POF/PE I-V2Y, I-V2Y(ZN)11Y 60332-1 -20 +80-20 +80 R 46 Fibre Optic Indoor/Outdoor Cable A/I-DQ(ZN)BH Fibre Optic Outdoor Cable A-DQ(ZN)B2Y (central) 60332-1 -20 +60-5 +50 R -20 +60-5 +50 R 20 T Fibre Optic Outdoor Cable A-DQ(ZN)B2Y (stranded) -20 +60-5 +50 R Fibre Optic Outdoor Cable A-DQ(ZN)B2Y (stranded, Multi-fibre) -20 +60-5 +50 R 23 T 26

HELUWIND WK 103w-T, WK 103w EMC D-T UV-resistant, UL/CSA-Style 10678/21179 Single-/Multicore Temperature range flexing -35 C up tp +90 C fixed installation -40 C up tp +90 C installation -20 C up tp +90 C Operating temperature at conductor max. +90 C Nominal voltage acc. to VDE U0/U 0,6/1kV also for 1500V DC capable acc. to UL 1000V Test voltage 50 Hz 3000 V Min. bending radius flexing 10 x cable diameter fixed installation 4 x cable diameter Torsion application +/-0 per 1 m for unshielded types +/- 90 per 1 m for shielded types Approvals UL/CSA-Style 10678/21179 cruus*, CE compliant Flame test FT1 Special stranded bare copper wires according to IEC 608 Special insulation heat-resistant Core identification black with numbers + gnye or colour code DIN 47100 Multicore cores stranded Tinned copper wrapped at EMV-shielded types Sheath Special compound heat-resistant Sheath colour black UV-resistant multi-climate operation torsion tested flame-retardant oil-resistant recyclable easy to tailor Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C. = The product conforms to the EC low-voltage directive 2006/95/EG. T 27

HELUWIND WK 103k-T, WK 103k EMC D-T UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened, Temperature range flexing -40 C up tp +80 C fixed installation -40 C up tp +80 C installation -40 C up tp +80 C Operating temperature at conductor max. +90 C Nominal voltage acc. to VDE U0/U 0,6/1kV also for 1500V DC capable acc. to UL 1000V Test voltage 50 Hz 3000 V Min. bending radius flexing 10 x cable diameter fixed installation 4 x cable diameter Torsion application +/-0 per 1 m for unshielded types +/- 90 per 1 m for shielded types Approvals UL-Style 10269/2570 cruus*, CE compliant Flame test FT1 Special stranded bare copper wires according to IEC 608 Special insulation cold flexing Core identification black with numbers + gnye or colour code DIN 47100 Multicore cores stranded Tinned copper wrapped at EMV-shielded types Sheath Special compound heat-resistant Sheath colour black UV-resistant multi-climate operation torsion tested flame-retardant oil-resistant recyclable easy to tailor Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C. = The product conforms to the EC low-voltage directive 2006/95/EG. T T 28

HELUWIND WK 135-T, WK 135 D-EMV T UV-resistant, UL/CSA-Style** 10553 / 20234, Single-/Multicore 90 C (80 C acc. to UL), suitable for offshore Temperature range flexing -40 C up tp +90 C fixed installation -40 C up tp +90 C acc. UL up to +80 C Operating temperature at conductor max. +90 C Nominal voltage acc. to VDE U0/U 0,6/1kV also for 1500V DC capable acc. to UL 1000V Test voltage 50 Hz 3000 V Min. bending radius flexing 10 x cable diameter fixed installation 4 x cable diameter Torsion application +/-150 per 1m Approvals UL-Style10553/20234 cruus, CE compliant Flame test FT1 IEC 60332-3-24 Halogen free IEC 60754-1 Smoke density IEC 61034-1+2 Special stranded bare copper wires according to IEC 608 Special insulation Core identification black with numbers + gnye or colour code DIN 47100 Multicore cores stranded Tinned copper wrapped at EMV-shielded types Sheath Special compound heat-resistant Sheath colour black halogen-free Extrem abrasion resistant high flame-retardant torsion testet suitable for Offshroe extremely oil resistant UV resistant recyclable Multi climate operation CCV non-adhesive Note The listed part numbers show only a small list of our production range. All types can be produced as Single- or Multicore, screened or unscreened versions. Please contact us with your individual requirements via fax +497150 9209-5135. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +50 C. = The product conforms to the EC low-voltage directive 2006/95/EG. Advantages of WK135-T over H07BN4-F: Burning behavior as per FT1 and IEC 60332-3-24 increased wear-resistance Recyclable T 29

HELUWIND WK 137-T / WK 137 EMV D-TFT4 UV-resistant, suitable for offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90 C, (80 C according to UL) Temperature range flexing -40 C up tp +90 C fixed installation -40 C up tp +90 C acc. UL up to +80 C Operating temperature at conductor max. +90 C Nominal voltage acc. to VDE U0/U 0,6/1kV also for 1500V DC capable acc. to UL 1000V Test voltage 50 Hz 3000 V Min. bending radius flexing 10 x cable diameter fixed installation 4 x cable diameter Torsion application +/-150 per 1m Approvals UL-Style10553/20234 cruus, CE compliant Flame test FT4 IEC 60332-3-24 Halogen free IEC 60754-1 Smoke density IEC 61034-1+2 Special stranded bare copper wires according to IEC 608 Special insulation Core identification black with numbers + gnye or colour code DIN 47100 Multicore cores stranded Tinned copper wrapped at EMV-shielded types Sheath Special compound heat-resistant Sheath colour black halogen-free Extrem abrasion resistant high flame-retardant torsion testet suitable for Offshroe extremely oil resistant UV resistant recyclable Multi climate operation CCV non-adhesive Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C. = The product conforms to the EC low-voltage directive 2006/95/EG. Advantages of WK137-T over H07BN4-F: Burning behaviorcsa FT4 + IEC 60332-3-24 increased wear-resistance Recyclable T T 30

HELUWIND WK 300w-Torsion 1,8/3kV UV-resistant Temperatur range flexing -35 C to +90 C fixed instal. -40 C to +90 C assemgly -20 C to +90 C Operating temperature max. +90 C Nominal voltage according VDE U0/U 1,8/3kV Test voltage 50 Hz 9000 V Min. bending radius flexing 10 x Leitungsdurchmesser fixed instal. 5 x Leitungsdurchmesser Torsion application +/-90 per 1m Special stranded bare copper wires according to IEC 608 Special insulation Core identification black Sheath Special compound Sheath colour black The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +30 C. = The product conforms to the EC low-voltage directive 73/23EWG bzw. 93/68EWG. UV resistant Multi climate operation torsion testet flame retardant oil resistant recyclable easy to tailor Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. T 31

HELUWIND WK 305-Torsion 1,8/3kV UV-resistant, suitable for offshore Temperature range flexing -35 C up tp +90 C fixed installation -40 C up tp +90 C Operating temperature at conductor max. +90 C Nominal voltage U0/U 1,8/3kV Test voltage 50 Hz 9000 V Min. bending radius flexing 10 x cable diameter fixed installation5 x cable diameter Flame retardant IEC 60332 Halogen free IEC 60754-1 Smoke density IEC 61034-1+2 Torsion application +/-150 per 1m Special stranded bare copper wires according to IEC 608 Special insulation Core identification black Sheath Special compound Sheath colour black halogen free extremely abrasion resistant Offshore suitable UV resistant Multi climate operation torsion testet flame retardant oil resistant recyclable easy to tailor Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. No reduction factor for ambient temperature up to +50 C. = The product conforms to the EC low-voltage directive 73/23EWG bzw. 93/68EWG. T T 32

HELUWIND WK H07BN4-F WIND-Torsion Torsion +/- 150 /1m, UV-resistant, 750V/90 C Temperature range: Ambient temperature at least -45 C +90 C at the conductor Nominal voltage: 450/750V Test voltage: 3000V Min. bending radius: 6 x cable diameter Torsion application: +/-150 per 1m Approvals: CE conformed Special bare stranded copper wire, as IEC 608 Special EPR insulation black Special EPR Sheath compound Sheath colour black The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. UV-resistant Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +4971509209-5135. T 33

HELUWIND WK 101 H 0,6/1kV halogen-free Temperature range: flexing -40 C to +9 0 C fixed installation acc. to UL -40 C to +90 C assembly -40 C to +90 C Operation temperature on conductor max. +90 C Nominal voltage: according to VDE U0/U 0.6/1kV, according to UL 1000V Test voltage 50 Hz: 3000 V Min. bending radius: 10 x cable diameter Torsion application: WK135-Torsion up to +/-150 per 1m Approvals: UL-style** 10553 singlecore types UL-style** 20234 multicore types cruus, CE conformed Flame test: FT4* in preparation Special bare stranded copper wire, as. per DIN VDE 0295 Special conductor insulation Conductor colours, black with numbers + gnye Cores cabled together by multicore types () = Screened version optional (EMC) Special SSH jacket compound, non-adhesive colour: black The HELUWIND WK 125 and WK 135-Torsion series of cables were specifically designed for use in wind turbines. We supply the leading wind turbines manufacturers with our cables. Advantages of WK 125 and 135-T over H07BN4-F: Burning behavior as per FT4 and IEC 60332-3-24 increased wear-resistance. Recyclable = The product conforms to the EC low-voltage directive 2006/95/EG UV-resistant oil-resistant in accordance with UL 1277, Table 11.2 oil resistant II non-adhesive high flame-retardant halogen-free Multi climate operation Torsion elastic (WK 135-T) Extrem abrasion-proof sheath Sea water resistant recyclable Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. T T 34

HELUWIND WK Fire Alarm Cable-Torsion halogen-free, FT1, 24V Temperature range: flexing -40 C to +80 C fixed installation -50 C to +90 C Nominal voltage: 24V Test voltage: Conductor/conductor 1500V conductor/shield 800V Minimum bending radius: 10 x cable diameter Torsion application: 3 x 360 on 5m Approvals: IEC 60332-1, test type B acc. to VDE 0472 Part 804, CE-conformed Flame test: FT1 Special stranded bare copper wires according to IEC 608 cl. 6 Special Polyester insulation Core identification black with numbers 1 _ cores stranded tinned copper helically wound for EMC screening Sheath PUR Sheath colour red RAL 3000 The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. very good oil and petrol-resistance acc. to DIN VDE 0250 and 0472 very resistant to acids, alkali and solvents extremely abrasion resistant halogen free Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +4971509209-5135. T 35

HELUWIND WK-NTSCGEWOEU-Torsion 3,6 / 6kV Temperature range flexingmin. -40 C +90 C atconductor Nominal voltage U0/U 1,8/3kV Test voltage 10kV Torsion application +/-100 per 1m free hanging Approvals acc. to DIN VDE 0250-813 CE compliant Minimum bending radius Special stranded tinned copper wires according to IEC 608 Special EPR insulation Core identification black conduction layer MC or CRSheath Sheathcolour black The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. for torsion application UV resistant Ozon resistant Oil resistant Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax+4971509209-5135. T T 36

HELUWIND WK DLO 2kV FT4, UV-resistant, UL44 1kV, 90 C, VW-1, LS, MSHA Temperature range: flexing -40 C to +90 C Nominal voltage: DLO 2000V Approvals: UL44, CSA, ICEA S-68-516/NEMA WC-8, MSHA, VW-1, FOR CT USE. LS CERTIFIED Flame test: FT4, FT1 Special tinned stranded copper wire, acc. to ASTM B-172, ASTM B-33 Special wrapping Special EPR insulation Special CPE jacket compound, non-adhesive Jacket colour: black The HELUWIND WK DLO was specifically designed for wind power applications for nominal voltageup tp 2kV. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. UV-resistant Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax+4971509209-5135. T 37

HELUWIND WK Powerline ALU 105 C robust 0,6/1kV or 1,8/3kV Temperature range flexing -20 C up tp +105 C fixed installation -40 C up tp +105 C Nominal voltage acc. to VDE U0/U 0,6/1kV or 1,8/3kV Test voltage 50 Hz 2500 V or 9kV Min. bending radius flexing 10 x cable diameter fixed installation4 x cable diameter Approvals in acc. to DIN VDE 0250-813 CE compliant Flame test IEC 60332-1 Special stranded bare copper wires Special insulation heat-resistant Core identification black Sheath Special compound heat-resistant Sheath colour black The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. UV resistant flame retardant oil resistant rexycable easy to tailor Note Our WK Powerline robust with the special shielding ist especially for flexing using or for heavy conditions. Pleasse ask for more notes and informations about the properties and the assembly. Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax +49 7150 9209-5135. HELUWIND WK Powerline ALU 0,6/1 kv HELUWIND WK Powerline ALU 1,8/3 kv HELUWIND WK Powerline ALU robust 0,6/1 kv HELUWIND WK Powerline ALU robust 1,8/3 kv HELUWIND WK Powerline ALU robust halogen free 0,6/1 kv All options in burial design possible. T T 38

HELUWIND WK THERMFLE 5 halogen-free, +5 C Temperature range flexing -20 C to +120 C non-flexing -55 C to +5 C Nominal voltage U0/U 0,6/1 kv Test voltage 3000 V Insulation resistance min. 100 MOhm x km Minimum bending radius flexiing 12,5-15x cable diameter fixed installation 4x cable diameter flame retardant IEC 60332-3-24 Cat. C Tinned stranded copper wire, acc. toiec 608 cl.5 Special insulation, polyolefin-copolymer halogen-free, flame retardant Jacket colour black Halogen-free, no release of corrosive or toxic gases Reduced propagation of fire Minimal smoke generation Good abrasion-resistance Goodoil and weathering resistance Resistant to UV radiation and ozone Thermal class B The materials used are silicone and cadmium-free and free of substances harmful to paint adhesion Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax+4971509209-5135. This special cable is used for example as a generator connecting cable in wind-turbines installations. Other installation uses: Connection cable for Heating Class B (130 C) installations for motors, transformers, relays, coils, electro-magnets, etc. Aggregate connections in the automobile industry. Halogen-free wiring of switchgear and control cabinets Connections for heating equipment. Supplies for high power lighting for industry, sports centres and street lighting. The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. T 39

HELUWIND WK (N)A2H 0,6/1kV, halogen-free Temperature range fixed installation -40 C to +90 C during assembly -5 C to +50 C max. +90 C at conductor Nominal voltage Uo/U 0,6/1kV also for 1500V DC capable Test voltage 50 Hz 4kV Approvals acc. to VDE CE compliant Min. bending radius 15 x cable diameter Flame test acc. to DIN VDE 0482 part 266-2, BS 4066, part 3 / EN 50266-2 / IEC 60332-3-24 (acc.din VDE 0472 Teil 804 cat. C) Smoke density acc. DIN VDE 0482 part 268, HD 606, EN 50268-12 / IEC 61034-12, BS 76 Teil 12 (acc. DIN VDE 0472 Teil 816) Corrosivity acc. VDE 0482 Teil 267 / DIN EN 50267-2-2 / IEC 60754-2 (acc. DIN VDE 0472 part 813) Halogen free acc. DIN VDE 0482 part 267 / EN 50267-2-1 / IEC 60754-1 (acc. DIN VDE 0472 part 815) ALU Conductor acc. IEC608cl.2 Special insulation VPE Core identification black Sheath Polymer compoun Sheathcolour black The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables. = The product conforms to the EC low-voltage directive 2006/95/EG. Halogen-free UV resistant Note Available cross sections, part no. and prices on request. Please contact us with your individual requirements via fax+4971509209-5135. T T 40

SENSORFLE VERTEILERFLE 2-Approvals VERTEILERFLE SENSORFLE-H Sensor actuator and distributor Cables Photo: HELUKABEL These cables for decentralised installation and control technology are used in plug systems, sensors and actuators. They constitute an important connecting element between the periphery and the PLC in production systems. While previously it was necessary to carry out timeconsuming wiring of switchgear cabinets and machines, now field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry. T 41

SENSORFLE sensor actuator cable, PVC, PUR, PVC/PUR Temperature range flexing -5 C to +80 C fixed installation -30 C to +80 C Peak operating voltage to 0,25 350 V from 0,34 500 V A.c. test voltage, 50 Hz to 0,25 1200 V from 0,34 2000 V Minimum bending radius Sensorflex PUR 7,5x cable ø Sensorflex PVC/PUR 7,5x cable ø Sensorflex PVC 15x cable ø Sensorflex PVC Bare copper, fine wire conductors in acc. with DINVDE0295 cl.5 and/or cl.6 and IEC608 cl.5 and cl.6 PVC core insulation, core colours see below Special PVC sheath Sensorflex PUR Bare copper, ultra-fine wire conductors acc. to DINVDE0295 cl.6 and/or IEC608 cl.6 PVC core insulation, core colours see below PUR sheath Sensorflex PVC/PUR Construction as above, except PVC inner sheath, with PUR sheath applied over it by means of coextrusion Sensorflex PVC Extensively oil resistant. Chemical Resistance - see table Technical Informations PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodb) Sensorflex PUR PUR sheath: low adhesion, extremely abrasion resistant, resistant to hydrolysis and microbial attack Sensorflex PVC/PUR The cables with the highly flexible stranded conductor, cl. 6, are suitable for drag chain applications These cables are produced to high quality specifications and conform with a yellow sheath to the DESINA -standard Sheath colour yellow (RAL1021) according to DESINA Note All cables can be delivered with UL/CSA approval and Cu shield. Desina : Explanation: see introduction. For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the I/O points to the system periphery enables significant reductions in installation costs. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. yellow 76061 76062 76063 76064 76065 76066 76071 76070 73485 73484 78240 76072 73870 orange 76076 76077 76078 76079 76080 76081 76086 76085 76087 76088 78241 76089 76090 grey 73473 73466 73474 73471 76094 76095 73472 76099 73368 72973 73728 73657 73548 No.cores x Jacket material 3x0,25 PVC 3x0,25 PUR 4x0,25 PVC 4x0,25 PUR 5G0,25 PVC 5G0,25 PVC/PUR 3G0,34 PVC/PUR 3x0,34 PVC 4x0,34 PVC 4x0,34 PVC/PUR 5x0,34 PVC 5G0,34 PVC 5G0,34 PVC/PUR Core colours brown, blue, black brown, blue, black brown, blue, black, white brown, blue, black, white brown, blue, black, white, green-yellow brown, blue, black, white, green-yellow brown, blue, green-yellow brown, blue, black brown, blue, black, white brown, blue, black, white brown, blue, black, white, grey brown, blue, black, white, green-yellow brown, blue, black, white, green-yellow Fine wire High Outer Ø flex ** mm 4,4 4,4 4,7 4,7 4,8 4,8 4,9 4,9 5,2 5,2 5,9 5,9 5,9 Cop. weight kg/km 7,2 7,2 9,6 9,6 12,0 12,0 9,8 9,8 13,1 13,1 16,4 16,4 16,4 Weight kg/km,0,0 26,0 26,0 30,0 30,0 30,0 30,0 43,0 43,0 54,0 54,0 54,0 AWG-No. 24 24 24 24 24 24 T T 42

VERTEILERFLE two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR Special PVC or PUR sheath acc. to UL Style 2464 for PVC, or UL Style 20233 for PUR Temperature range flexing -5 C to +80 C fixed installation -30 C to +80 C Nominal voltage 300/500 V A.c. test voltage, 50 Hz to 0,25 1200 V from 0,34 2000 V Minimum bending radius Sensorflex Two approvals PVC 7,5x cable ø Sensorflex Two approvals PUR 15x cable ø PVC cables Bare copper, fine wire in acc. with DINVDE0295 cl.5 or IEC608 cl.5 PVC core insulation, core colours see below Special PVC PUR cables Bare copper, ultra-fine wire conductors acc. to DINVDE0295 cl.6 and/or IEC608 cl.6 PVC core insulation Core colours see below PUR sheath Part Nos. 79907, 75642, 79850 Construction like SENSORFLE two-approvals, except with polypropylene core insulation PVC cables Extensively oil resistant. Chemical Resistance - see table Technical Informations PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC60332-1 (equivalent DINVDE0472 part804 test methodb) PUR cables Low adhesion, extremely abrasion resistant, resistant to hydrolysis and microbial attack Special feature The cables with the highly flexible stranded conductor, cl. 6, are suitable for drag chain applications The types with PVC/PUR sheath material have a PVC inner sheath, with a PUR sheath applied over it by means of coextrusion Note All additional cross-sections, also with UL/CSA approval, are available on request. For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the I/O points to the system periphery enables significant reductions in installation costs. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. SENSORFLE 2-APPROVALS Part no. Jacket colour No.cores x 78284 Grey RAL 7001 3x0,25 79907 Grey RAL 7001 4x0,25 78286 Grey RAL 7001 6x0,25 76345 Grey RAL 7001 3x0,34 76347 Grey RAL 7001 4x0,34 76348 Grey RAL 7001 5G0,34 76349 Grey RAL 7001 5G0,34 79850 Grey RAL 7001 5G0,34 78287 Grey RAL 7001 5G0,34 78288 Grey RAL 7001 3G0,75 76351 Grey RAL 7001 3G0,75 73571 Grey RAL 7001 3G0,75 75642 Black RAL9005 3G0,75 Jacket material PUR PUR PVC PVC PVC PVC/PUR PVC/PUR PUR PVC/PUR PUR PVC PVC PUR Core colours brown, blue, black brown, blue, black, white brown, blue, black, white, grey, pink brown, blue, black brown, blue, black, white brown, blue, black, white, green-yellow brown, blue, black, white, green-yellow brown, blue, black, white, green-yellow JZ, black with numbering + greenyellow JZ, black with numbering + greenyellow brown, blue, green-yellow JZ, black with numbering + greenyellow JZ, black with numbering + greenyellow Fine wire High flex ** Outer Ø mm 4,4 4,7 5,2 4,9 5,2 5,9 5,9 5,9 5,9 5,9 6,7 6,7 5,9 Cop. weight kg/km 7,2 9,6,4 9,8 13,1 16,4 16,4 16,4 16,4 21,6 28,8 21,6 21,6 Weight kg/km 18,0 18,0 36,0 30,0 43,0 54,0 54,0 54,0 54,0 58,0 88,0 58,0 58,0 AWG-No. 24 24 24 18 18 18 18 Continuation T 43

VERTEILERFLE two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR SENSORFLE 2-APPROVALS Part no. Jacket colour No.cores x 74551 Grey RAL 7001 4G0,75 78289 Grey RAL 7001 4G0,75 78290 Grey RAL 7001 2x1 77352 Black RAL9005 2x1 76350 Grey RAL 7001 11G1 78291 Grey RAL 7001 2x1,5 73587 Grey RAL 7001 3G1,5 Verteilerflex 2-APPROVALS Part no. Jacket colour No.cores x 76352 Grey RAL 7001 4G0,34 76353 756 76354 76355 76356 Grey RAL 7001 Grey RAL 7001 Grey RAL 7001 Grey RAL 7001 Grey RAL 7001 6G0,34 8G0,34 8G0,34 12G0,34 16G0,34 Jacket material PUR PVC/PUR PVC PVC PVC/PUR PVC PVC Jacket material PVC/PUR PVC/PUR PUR PVC/PUR PVC/PUR PVC/PUR Core colours JZ, black with numbering + greenyellow JZ, black with numbering + greenyellow black with number 1-2 black with number 1-2 black with number 1-8, bn, bu, gn, ye brown, blue brown, blue, green-yellow Core colours brown, blue, green-yellow, white, green, yellow, grey brown, blue, green-yellow, white, green, yellow, grey, pink, red white, red-blue, green, wh-green, yellow, brown-green, gy-pink, brown, blue, green-yellow brown, blue, green-yellow, white, green, yellow, grey, pink, red, black, violet brown, blue, gnye, gnwh, white, rdbu, green, whgn, yellow, bngn, grey, whye, pink, yebn, red bn, bu, gnye, gnwh, wh, rdbu, gn, whgn, ye, bngn, gy, whye, pk, yebn, rd, whgy, bk, gybn, vt Fine wire Fine wire High flex ** High flex ** Outer Ø mm 6,9 7,0 7,2 7,2 12,0 6,8 6,9 Outer Ø mm 8,7 9,1 10,0 9,1 10,3 10,5 Cop. weight kg/km 29,0 29,0 19,2 19,2 105,6 29,0 44,0 Cop. weight kg/km 35,0 42,0 65,0 48,0 61,0 74,0 Weight kg/km 66,0 66,0 56,0 56,0 5,0 75,0 94,0 Weight kg/km 82,0 106,0 3,0 110,0 138,0 170,0 AWG-No. 18 18 17 17 17 16 16 AWG-No. T T 44

VERTEILERFLE for sensor actuator distributor boxes, PVC, PUR or PVC/PUR Temperature range PVC cables PVC cables flexing -5 C to +80 C fixed installation -30 C to +80 C Operating voltage Bare copper, fine wire conductors in acc. with DINVDE0295 cl.5 and/or cl.6 and/or IEC608 cl.5 and cl.6 Extensively oil resistant. Chemical Resistance - see table Technical Informations U0/U 300/500 V PVC core insulation PVC self-extinguishing and flame retardant A.c. test voltage, 50 Hz Core colours see below according to VDE 0482-332-1-2, DIN EN 2000 V Special PVC sheath 60332-1-2/ IEC60332-1 (equivalent Minimum bending radius PUR cables DINVDE0472 part804 test methodb) highly flexible 7,5x cable ø Bare copper, extra fine wire conductor to PUR cables flexibel 15x cable ø DINVDE0295 cl.6 and IEC608 cl.6 Low adhesion, extremely abrasion resistant, PVC core insulation resistant to hydrolysis and microbial attack Core colours see below Special feature PUR sheath The cables with the highly flexible stranded conductor, cl. 6, are suitable for drag chain applications The types with PVC/PUR sheath material have a PVC inner sheath, with a PUR sheath applied over it by means of coextrusion Note All cables can be delivered with UL/CSA approbation and Cu shield. Further core numbers, cross-sections an sheath colours available on request. These cables are used in connector systems for sensors an actuators. In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. black 76105 76639 76107 72961 76109 76110 76108 71254 76111 76112 76113 761 76640 74034 grey 76115 73574 73993 74729 72951 76117 76118 76119 77642 76120 76121 761 79921 76123 No.cores x 4G0,34 4G0,34 6G0,34 8G0,34 8x0,34 8x0,34 8x0,34 11x0,34 12x0,34 16G0,34 16G0,34 8G0,5 12G0,5 x0,5 16G0,5 16G0,5 Jacket material PVC PVC/PUR PVC/PUR PVC/PUR PVC PUR PVC/PUR PVC PVC/PUR PVC/PUR PVC/PUR PUR PUR PVC PVC/PUR PUR Core colours brown, blue, black, white, green-yellow yellow, white, green, grey, green-yellow, brown, blue white, green, yellow, grey, pink, red, brown, blue, green-yellow grey. pink, red, black, violet, white, green, yellow, brown, blue, green-yellow white, green, yellow, grey, pink, red, black, violet, blue, brown white, green, yellow, grey, pink, red, black, violet, blue, brown white, green, yellow, grey, pink, red, black, violet, blue, brown black with number 1-2+DIN 47100 pink, yebn, red, gypk, white, rdbu, green, whgn, yellow, bngn, gy, whye blue with no.1-2 + gnye, gypk, wh, rdbu, gn, whgy, ye, bngy, whye, pk, yebn, rd, whgy, bk, gybn, vt bn, gypk, rdbu, whgn, bngn, whye, yebn, gybn, bu, wh, gn, ye, gy, pk, rd, bk, vt, gnye brown, blue, green-yellow, grey-pink, red-blue, white-green, brown-green, white, green, yellow, grey gypk. rdbu, whgn, bngn, whye, yebn, white, green, yellow, grey, pink, red, brown, blue, gnye Black, with printing BR1, BR2, BL1, BL, numbers 1- gy, bngn, gn, rdbu, gypk, wh, whgn, whgy, bk, whye, pk, ye, rd, yebn, vt, gybn, gnye, bn, bu gypk, wh, rdbu, gn, whgn, ye, bngn, gy, whye, pk, yebn, rd, whgn, bk, vt, bn, bu, gnye Fine wire High Outer Ø flex ** mm 5,8 8,7 9,1 9,1 9,1 9,1 8,8 10,0 10,3 12,5 10,5 9,9 10,4 12,3 11,6 11,6 Cop. weight kg/km 18,0 36,0 42,0 48,0 41,0 41,0 36,0 65,0 61,0 89,0 74,0 68,0 87,0 125,0 106,0 106,0 Weight kg/km 58,0 82,0 106,0 110,0 107,0 107,0 102,0 3,0 138,0 193,0 170,0 136,0 160,0 201,0 183,0 183,0 AWG-No. 20 20 20 20 20 T 45

SENSORFLE-H sensor actuator cables, halogen-free, high flexible drag chain cable, PUR, mantle EVA +125 C Temperature range Li12Y11Y/Li9Y11Y flexing -30 C to +80 C fixed installation -40 C to +80 C Li4G4G flexing -25 C to +125 C fixed installation -40 C to +125 C Operating voltage up to 0,25 350 V 0,34 and greater 500 V A.c. test voltage, 50 Hz up to 0,25 1200 V 0,34 and greater 2000 V Minimum bending radius Sensorflex-H Li12Y11Y Approx. 5x cable ø Sensorflex-H Li9Y11Y Approx. 7,5x cable ø Sensorflex-H Li4G4G Approx. 15x cable ø Sensorflex-H (Li12Y11Y-HF) Bare copper, extra-fine wire conductor according to DINVDE0295 cl.6 and IEC608 cl.6 TPE core insulation, core colours see below PUR sheath Sensorflex-H (Li9Y11Y-HF) Bare copper, extra-fine wire conductor according to DINVDE0295 cl.6 and IEC608 cl.6 PP core insulation, core colours see below PUR sheath Sensorflex-H (Li4G4G) Tinned copper, fine wire conductor according to DINVDE0295 cl.5 and IEC608 cl.5 EVA-based compound for core and sheath Sheath red/brown ( RAL8016) Sensorflex-H (Li12Y11Y-HF) Sensorflex-H (Li9Y11Y-HF) PUR sheath, low adhesion, extremely abrasion resistant, resistant to hydrolysis and microbial attack Highly flexible drag chain cable Sensorflex-H (Li4G4G) Heat-resistant Not suitable for use with drag chains For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the I/O points to the system periphery enables significant reductions in installation costs. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. SENSORFLE-H (Li12Y11Y) high flexible drag chain cable, PUR Part no. black grey No.cores x Jacket Core colours material 76283 76299 2x0,25 PUR brown, blue 76284 76300 3x0,25 PUR brown, blue, black 76285 76301 4x0,25 PUR brown, blue, black, white 76286 76302 5x0,25 PUR brown, blue, black, white, grey 76287 76303 2x0,34 PUR brown, blue 76288 76304 3x0,34 PUR brown, blue, black 76289 76305 4x0,34 PUR brown, blue, black, white 76290 76306 5x0,34 PUR brown, blue, black, white, grey 78265 78266 5G0,34 PUR brown, blue, black, white, green-yellow 76291 76307 2x0,5 PUR brown, blue 78267 78268 3G0,5 PUR JZ, black with numbering + greenyellow 76292 76308 3x0,5 PUR brown, blue, black 76293 76309 4x0,5 PUR brown, blue, black, white 76294 76310 5x0,5 PUR brown, blue, black, white, grey Fine wire High Outer Ø flex ** mm 4,4 4,4 4,7 4,8 4,9 4,9 5,2 5,9 5,9 5,0 5,7 5,0 5,5 6,0 Cop. weight kg/km 4,8 7,2 9,6 12,0 6,5 9,8 13,1 16,4 16,4 9,6,4,4 19,2 24,0 Weight kg/km,0,0 26,0 30,0 30,0 30,0 43,0 54,0 54,0 40,0 43,0 40,0 47,0 55,0 AWG-No. 24 24 24 24 20 20 20 20 20 Continuation T T 46

SENSORFLE-H sensor actuator cables, halogen-free, high flexible drag chain cable, PUR, mantle EVA +125 C SENSORFLE-H (Li12Y11Y) high flexible drag chain cable, PUR Part no. black 76295 78269 76296 78271 76297 78273 76298 grey 76311 78270 76312 78272 76313 78274 763 No.cores x 2x0,75 3G0,75 3x0,75 4G0,75 4x0,75 5G0,75 5x0,75 Jacket material PUR PUR PUR PUR PUR PUR PUR Core colours brown, blue brown, blue, green-yellow brown, blue, black brown, blue, black, green-yellow brown, blue, black, white JZ, black with numbering + greenyellow brown, blue, black, white, grey SENSORFLE-H (Li9Y11Y) high flexible drag chain cable, PUR Part no. Jacket colour No.cores x Jacket Core colours material 75801 Grey RAL 7001 3x0,25 PUR brown, blue, black 77468 Grey RAL 7001 4x0,25 PUR brown, blue, black, white 76705 Grey RAL 7001 8x0,25 PUR DIN 47100 77427 Grey RAL 7001 4x0,34 PUR brown, blue, black, white 77428 Grey RAL 7001 3G0,75 PUR JZ, black with numbering + greenyellow 78275 Grey RAL 7001 3x0,75 PUR JZ, black with numbering + greenyellow 77429 Grey RAL 7001 4G0,75 PUR JZ, black with numbering + greenyellow SENSORFLE-H (Li4G4G) unqualified for drag chain cable, sheath EVA Part no. Jacket colour No.cores x Jacket Core colours material 78359 Red-brown RAL 4G0,75 EVA brown, blue, black, green-yellow 8016 73575 Red-brown RAL 3G1 EVA brown, blue, green-yellow 8016 Fine wire Fine wire Fine wire High Outer Ø flex ** mm 5,7 5,9 5,9 6,2 6,0 7,0 7,0 High flex ** High flex ** Outer Ø mm 4,5 4,7 6,0 4,9 6,2 6,2 6,2 Outer Ø mm 7,0 7,0 Cop. weight kg/km,4 21,6 21,6 28,8 28,8 36,0 36,0 Cop. weight kg/km 7,2 9,6 19,2 13,1 21,6 21,6 28,8 Cop. weight kg/km 28,8 29,0 Weight kg/km 47,0 54,0 54,0 67,0 66,0 80,0 80,0 Weight kg/km,0 26,0 49,0 43,0 54,0 54,0 66,0 Weight kg/km 65,0 60,0 AWG-No. 18 18 18 18 18 18 18 AWG-No. 24 24 24 18 18 18 AWG-No. 18 17 T 47

AIRPORT 400 Hz Cables for airport 400 Hz Photo: HELUKABEL Special cable for drum reeling purpose meeting the highest mechanical stresses. Mobile cable in flexible feeds in 400 Hz units, especially as aircraft feeder line on airports. The qualified employees of our special cable department will give individual advice and assistance to develop and construct your cable. Your personal advice is important to us in order that we can offer you the right cable for your purpose. Depending on the cable type these special cables can be offered with a minimum length of 100 m, with short delivery periods. T T 48

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant Temperature range Fine copper wire in acc. with DINVDE0295 Low adhesion, abrasion resistant, -40 C to +90 C Nominal voltage and IEC608 Core insulation TPE, black halogen-free, resistant to UV-, oil-, hydrolysis and microbial attack 115/200 V with number 1-6 + blue/..., Special feature: Operating voltage U0/U 0,6/1 kv with number 7-30/1 4 cores each 1 twisted to a quad The use of four-core cables to transmit large amounts of power in a 400 Hz grid results in Test voltage Cores and 6 bundles laid-up together voltage asymmetries and larger inductive 4000 V PUR inner sheath voltage losses. These unfavourable cable Bending radius Support braiding characteristics can be improved through the flexing 7x cable ø fixed installation 4x cable ø PUR outer sheath, orange (RAL 2003) Part No. 75992 Bare copper conductor, 7 strands employment of seven-core cables. In this case the central core is used as a protective or earth conductor (green/yellow or blue) Core insulation cross-linked polyethylene, and six cores with the same cross-section black with number 1-6 + gnye (black with imprint) stranded in a single layer Polyethylene inner sheath around the central core. Each pair of two Concentric conductor of plain Cu wires, cross-section 35 opposite cores is connected in parallel to a phase conductor. Black polyehtylene outer sheath Note Distribution only over authorised partner 400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons, 400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors. s: Below floor level cable dispensers (drums), attached to jetways and retractable articulated cable carries. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 700573 7x 25+ 6x 4x1,0 41,0 1910,0 20,0 4 75992 7G35 35,8 2746,0 3050,0 2 770009 7x 35+ 6x 4x1,0 45,5 2625,0 2950,0 2 700574 7x 50+ 6x 4x1,0 51,0 3590,0 4030,0 1 T 49

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant Temperature range Part Nos. 700566-700569 Part Nos. 700570, 770001-770003 -40 C to +90 C Fine copper wire in acc. with DINVDE0295 Low adhesion, abrasion resistant, Nominal voltage and IEC608 halogen-free, resistant to UV-, oil-, 115/200 V Special plastic core insulation hydrolysis and microbial attack Operating voltage Sheath colour yellow (RAL1021) U0/U 0,6/1 kv Part Nos. 700570, 770001-770003 Note Test voltage Fine copper wire in acc. with DINVDE0295 4000 V and IEC608 Distribution only over authorised partner Bending radius 6x cable ø Core insulation TPE, grey with number 1-4/1 Core 1 stranded with bundle conductor Double-sheath TPE/PUR Sheath colour yellow (RAL1021) Part Nos. 700571, 770005, 770004, 700572 Each set of 4 parts, 700570, 770001-770003, is stranded 400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons, 400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors. Highly flexible, and can thus be plugged directly into the connector in the aircraft without an adapter, and without endangering the contacts. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 700566 1x 35 11,5 336,0 430,0 2 700571 4x 1x 35+ 4x 1,0 33,0 98,0 2600,0 2 700570 1x 35+ 4x 1,0,0 375,0 490,0 2 770005 4x 1x 50+ 4x 1,0 40,0 2074,0 3900,0 1 770001 1x 50+ 4x 1,0 17,0 519,0 600,0 1 770004 4x 1x 70+ 4x 1,0 50,0 2844,0 4300,0 2/0 700567 1x 50 12,6 480,0 665,0 1 700572 4x 1x 120+ 4x 1,0 56,0 4765,0 7400,0 4/0 700568 1x 70,0 672,0 910,0 2/0 770002 1x 70+ 4x 1,0 18,7 711,0 800,0 2/0 770003 1x 120+ 4x 1,0 25,0 1191,0 00,0 4/0 700569 1 x 120 23,0 1152,0 1545,0 4/0 T T 50

HELUTRUCK 270 HELUTRUCK 271 HELUTRUCK 272 / 273 Truck Cables Photo: HELUKABEL These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. T 51

HELUTRUCK 270 with ADR-approval, PVC low voltage cable for commercial vehicles Temperature range -40 C to +85 C Bare copper, fine wire in acc. with DINVDE0295 cl.5 or IEC608 cl.5 Test voltage Cold-resistant special PVC core insulation 2000 V min. 5 minutes Core coding: Capacitance up to 9 cores by colour, max. 50 pf/m for the data pair 10 cores and above white with numbers max. 100 pf/m between data pair cores (see below) and the other cores Special PVC sheath Insulation resistance Colour black min. 20 MOhm x km Minimum bending radius 12x cable ø Cold-resistant special PVC sheath, UV-resistant Largely resistant to oil, weather, and chemicals; Chemical resistance see table Technical Information PVC self-extinguishing and flame retardant, test methodb according to VDE0472 part804 and IEC60332-1 These cables conform to the national standard ISO41 and the international standard DIN/ISO67 Component codes TÜ.EGG.073-03 Special feature: Complies with GGVS regulations Approved and tested by the TÜV technical inspectorate These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for trailers and semitrailers. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 700016 2x 0,5 4,8 9,6 40,0 20 700577 2x 1,5 6,6 28,8 66,0 16 700575 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 700579 4x 1,5 7,5 57,6 106,0 16 700582 7 x 0,75 7,3 50,4 101,0 18 75262 6x 1,5+ 1x 2,5 10,3 110,5 187,0 16 75255 2x 1 6,0 19,2 56,0 17 700032 7x 1,5 10,3 100,8 185,0 16 75254 2x 1 6,0 19,2 56,0 17 75261 7x 1,5 8,9 100,2 165,0 16 75256 3x 1 6,3 28,8 66,0 17 75263 8x 1,5+ 1x 2,5 11,7 139,2 238,0 16 700578 3x 1 6,6 28,8 66,0 17 700583 8x 1,5+ 5x 2,5,8 235,2 360,0 16 75257 4x 1 6,8 38,4 80,0 17 75267 9x 1,5+ 4x 2,5,8 200,0 350,0 16 75260 5x 1+ 1x 2,5 9,0 72,0 132,0 17 75265 10 x 1,5 + 3 x 2,5,4 215,0 366,0 16 75258 5x 1 7,5 48,0 98,0 17 75319 10 x 1,5 + 3 x 2,5 + 2 x 1,5,4 244,8 393,0 16 700580 5x 1+ 1x 2,5 9,0 72,0 132,0 17 700017 10 x 1,5 + 3 x 2,5 + 2 x 1,5,3 244,8 391,0 16 75259 5x 1+ 1x 2,5 9,0 72,0 132,0 17 75266 10 x 1,5 + 3 x 2,5 13,0 216,0 345,0 16 700581 5x 1+ 1x 2,5 9,0 72,0 132,0 17 700018 11 x 1,5 + 3 x 2,5 13,5 230,4 365,0 16 700576 2x 1,5 6,6 28,8 66,0 16 7002 3x 2,5+ 4x 1,5 10,3 129,6 1,0 T T 52

HELUTRUCK 271 with ADR-approval, PUR low voltage cable for commercial vehicles Temperature range Bare copper, fine wire in acc. with PUR outer sheath, low adhesion, abrasion -40 C to +85 C Test voltage DINVDE0295 cl.5 or IEC608 cl.5 Cold-resistant special PVC core insulation resistant, halogen-free, resistant to UV-, oil-, hydrolysis and microbial attack 2000 V min. 5 minutes Core coding: These cables conform to the national Capacitance max. 50 pf/m for the data pair max. 100 pf/m between data pair cores and the other cores up to 9 cores by colour, 10 cores and above white with numbers (see below) Inner sheath from special PVC standard ISO41 and the international standard DIN/ISO67 Component codes TÜ.EGG.074-03 Special feature: Insulation resistance PUR outer sheath Complies with GGVS regulations min. 20 MOhm x km Colour black Approved and tested by the TÜV technical Minimum bending radius Also available with PVC sheath inspectorate 12x cable ø PUR sheath provides high resistance to abrasion, UV and wear These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for trailers and semitrailers manufactured for the transport of GGVS hazardous substances. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 75528 2x 1 6,0 19,0 56,0 17 700591 5x 1+ 1x 0,25 9,0 72,0 132,0 17 700585 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 75533 5x 1+ 1x 2,5 9,0 72,0 132,0 17 75529 2x 1 6,0 19,0 56,0 17 700590 5x 1+ 1x 2,5 9,0 72,0 132,0 17 700586 2x 1,5 6,6 28,8 67,0 16 75534 5x 1+ 1x 2,5 9,0 72,0 132,0 17 700587 2x 1,5 6,6 28,8 67,0 16 75536 6x 1,5+ 1x 2,5 10,3 110,4 187,0 16 75932 2x 4+ 3x 1,5+ 2x 1,5 12,0 8,8 230,0 12 700592 7 x 0,75 7,9 50,4 100,0 18 75541 2x 6+ 3x 1,5+ 2x 1,5 12,0 187,2 320,0 10 75535 7x 1,5 8,9 100,8 165,0 16 75540 2x 6+ 3x 1,5 12,0 158,6 270,0 10 75537 8x 1,5+ 1x 2,5 11,7 139,2 238,0 16 75530 3x 1 6,3 28,8 66,0 17 75539 10 x 1,5 + 3 x 2,5,4 2,0 366,0 16 700588 3x 1 6,3 28,8 66,0 17 700594 10 x 1,5 + 3 x 2,5,4 2,0 366,0 16 75531 4x 1 6,8 38,5 80,0 17 75538 10x 1,5+ 3x 2,5+ 2x 1,5,4 244,8 393,0 16 700589 4x 1,5 7,5 57,6 105,0 16 700595 18 x 1,5 17,0 259,2 520,0 16 75532 5x 1 7,5 48,1 98,0 17 700596 25 x 1,5 19,9 360,0 730,0 16 T 53

HELUTRUCK 272 / 273 Flat cable for the sideways lighting with GGVS-authorization, Battery cable, battery charging cable HELUTRUCK 272 HELUTRUCK 272 UV-resistant, largely resistant to oil, Temperature range Bare copper wire conductors in acc. with weather, and chemicals, self-extinguishing -40 C to +85 C DINVDE0295 cl.5 or IEC608 cl.5 and flame retardant, test method B Test voltage Special PVC core insulation, cold-resistant according to VDE0472 part804 and 2000 V Core colours white, brown (Part No.76706), IEC60332-1 Insulation resistance white, black (Part No.78983, 700035) Chemical resistance see table Technical min. 20 MOhm x km Cold-resistant special PVC sheath Information Minimum bending radius Colour black HELUTRUCK 272 fixed installation 5x cable ø HELUTRUCK 273 Polarity easy to determine by a white line HELUTRUCK 273 Bare copper, fine wire in acc. with on the sheath above the white core Temperature range DINVDE0295 cl.5 or IEC608 cl.5 HELUTRUCK 273-40 C to +85 C Special PVC core insulation, cold-resistant Complies with GGVS regulations Nominal voltage 75 V DC Core colours red and black Cold-resistant special PVC sheath Approved and tested by the TÜV technical inspectorate Test voltage Colour black The additional sheath means that the cable 3000 V Also available with PUR sheath is very robust, and can be installed without Insulation resistance a corrugated conduit min. 20 MOhm x km Installation time is shorter due to twin Minimum bending radius design fixed installation 15x cable ø Polarity is easy to determine even without stripping thanks to an imprint with the type designation and on the sheath over the positive core. This helps prevent wrong connections The special construction of the conductor enables optimal crimping Easy mechanical separation of the sheath web HELUTRUCK 272 This low-voltage cable is designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for trailers and semitrailers. This flat cable can be used for simple and quick contacting of sidelights by means of core penetration. Its flat construction and the special contacting method eliminate the need for time-consuming assembly of cables. This facilitates quick installation, making it possible to save a great deal of time. HELUTRUCK 273 This battery cable can be used between the battery and the ultimate consumer (e.g. DC motor of the tail-lift). = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. HELUTRUCK 272 HELUTRUCK 273 Part no. No.cores x Outer Ø Cop. Weight AWG-No. Part no. No.cores x Outer Ø Cop. Weight AWG-No. mm weight kg/km kg/km mm weight kg/km kg/km 76706 2x1,5 6,8 28,8 90,0 16 75507 2x2,5 9,4 48,0 87,0 78983 2x1,5 6,8 28,8 90,0 16 75508 2x4 11,5 77,0 125,0 12 700035 2x1,5 6,8 28,8 90,0 16 75509 2x6 15,2 116,0 175,0 10 75510 2x10 18,8 192,0 270,0 8 75511 2x16 21,0 308,0 390,0 6 75512 2x25 25,6 480,0 575,0 4 75513 2x35 28,0 672,0 820,0 2 755 2x50 33,0 960,0 1065,0 1 75515 2x70 36,0 16,8 75,0 2/0 T T 54