Removal Of EMG Artifacts From Multichannel EEG Signal Using Automatic Dynamic Segmentation

Similar documents
Design of effective algorithm for Removal of Ocular Artifact from Multichannel EEG Signal Using ICA and Wavelet Method

Hybrid Wavelet and EMD/ICA Approach for Artifact Suppression in Pervasive EEG

Research Article Design and Analysis of a High Secure Video Encryption Algorithm with Integrated Compression and Denoising Block

DICOM medical image watermarking of ECG signals using EZW algorithm. A. Kannammal* and S. Subha Rani

Study of White Gaussian Noise with Varying Signal to Noise Ratio in Speech Signal using Wavelet

International Journal of Advance Research in Engineering, Science & Technology

Research Article. ISSN (Print) *Corresponding author Shireen Fathima

ECG Denoising Using Singular Value Decomposition

Multichannel Satellite Image Resolution Enhancement Using Dual-Tree Complex Wavelet Transform and NLM Filtering

Image Resolution and Contrast Enhancement of Satellite Geographical Images with Removal of Noise using Wavelet Transforms

Design Approach of Colour Image Denoising Using Adaptive Wavelet

COMPRESSION OF DICOM IMAGES BASED ON WAVELETS AND SPIHT FOR TELEMEDICINE APPLICATIONS

ECG ARTIFACT REMOVAL FROM SURFACE EMG SIGNALS BY COMBINING EMPIRICAL MODE DECOMPOSITION AND INDEPENDENT COMPONENT ANALYSIS

A Hybrid Pre-Processing Techniques for Artifacts Removal to Improve the Performance of Electroencephalogram (EEG) Features Extraction

Comparative Analysis of Wavelet Transform and Wavelet Packet Transform for Image Compression at Decomposition Level 2

WAVELET DENOISING EMG SIGNAL USING LABVIEW

EMBEDDED ZEROTREE WAVELET CODING WITH JOINT HUFFMAN AND ARITHMETIC CODING

Artifact rejection and running ICA

Research on sampling of vibration signals based on compressed sensing

Identification of Motion Artifact in Ambulatory ECG Signal Using Wavelet Techniques

MULTI WAVELETS WITH INTEGER MULTI WAVELETS TRANSFORM ALGORITHM FOR IMAGE COMPRESSION. Pondicherry Engineering College, Puducherry.

Robust Joint Source-Channel Coding for Image Transmission Over Wireless Channels

Image Denoising by Data Adaptive and Non-Data Adaptive Transform Domain Denoising Method Using EEG Signal

A Novel Approach towards Video Compression for Mobile Internet using Transform Domain Technique

SedLine Sedation Monitor

Brain-Computer Interface (BCI)

Single image super resolution with improved wavelet interpolation and iterative back-projection

Single Channel Speech Enhancement Using Spectral Subtraction Based on Minimum Statistics

ECG SIGNAL COMPRESSION BASED ON FRACTALS AND RLE

INTRA-FRAME WAVELET VIDEO CODING

Speech Enhancement Through an Optimized Subspace Division Technique

PROCESSING YOUR EEG DATA

EEG Eye-Blinking Artefacts Power Spectrum Analysis

Image Compression Techniques Using Discrete Wavelet Decomposition with Its Thresholding Approaches

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

Feature Conditioning Based on DWT Sub-Bands Selection on Proposed Channels in BCI Speller

3D MR Image Compression Techniques based on Decimated Wavelet Thresholding Scheme

CS229 Project Report Polyphonic Piano Transcription

Reduction of Noise from Speech Signal using Haar and Biorthogonal Wavelet

2-Dimensional Image Compression using DCT and DWT Techniques

Identification, characterisation, and correction of artefacts in electroencephalographic data in study of stationary and mobile electroencephalograph

BrainPaint, Inc., Malibu, California, USA Published online: 25 Aug 2011.

Unequal Error Protection Codes for Wavelet Image Transmission over W-CDMA, AWGN and Rayleigh Fading Channels

Application of cepstrum prewhitening on non-stationary signals

Reconstruction of Ca 2+ dynamics from low frame rate Ca 2+ imaging data CS229 final project. Submitted by: Limor Bursztyn

Experiments on musical instrument separation using multiplecause

HBI Database. Version 2 (User Manual)

Adaptive bilateral filtering of image signals using local phase characteristics

Multiple-Window Spectrogram of Peaks due to Transients in the Electroencephalogram

CHROMA CODING IN DISTRIBUTED VIDEO CODING

E E Introduction to Wavelets & Filter Banks Spring Semester 2009

A NEW LOOK AT FREQUENCY RESOLUTION IN POWER SPECTRAL DENSITY ESTIMATION. Sudeshna Pal, Soosan Beheshti

Speech and Speaker Recognition for the Command of an Industrial Robot

Multi-step Independent Component Analysis for Removing Cardiac Artefacts from Back SEMG Signals

A review of CLS retracking. solutions for coastal altimeter waveforms

Motion Artifact removal in Ambulatory ECG Signal using ICA

Skip Length and Inter-Starvation Distance as a Combined Metric to Assess the Quality of Transmitted Video

Seismic data random noise attenuation using DBM filtering

Color Image Compression Using Colorization Based On Coding Technique

A COMPARATIVE STUDY ALGORITHM FOR NOISY IMAGE RESTORATION IN THE FIELD OF MEDICAL IMAGING

PERCEPTUAL QUALITY ASSESSMENT FOR VIDEO WATERMARKING. Stefan Winkler, Elisa Drelie Gelasca, Touradj Ebrahimi

Reproducibility Assessment of Independent Component Analysis of Expression Ratios from DNA microarrays.

Signal Processing with Wavelets.

EVALUATION OF SIGNAL PROCESSING METHODS FOR SPEECH ENHANCEMENT MAHIKA DUBEY THESIS

Real-time EEG signal processing based on TI s TMS320C6713 DSK

A SVD BASED SCHEME FOR POST PROCESSING OF DCT CODED IMAGES

An Efficient Low Bit-Rate Video-Coding Algorithm Focusing on Moving Regions

OBJECTIVE EVALUATION OF A MELODY EXTRACTOR FOR NORTH INDIAN CLASSICAL VOCAL PERFORMANCES

SOBI-RO for Automatic Removal of Electroocular Artifacts from EEG Data-Based Motor Imagery

Voice & Music Pattern Extraction: A Review

Lecture 2 Video Formation and Representation

A Parametric Autoregressive Model for the Extraction of Electric Network Frequency Fluctuations in Audio Forensic Authentication

TERRESTRIAL broadcasting of digital television (DTV)

A Novel Video Compression Method Based on Underdetermined Blind Source Separation

System Identification

Guidance For Scrambling Data Signals For EMC Compliance

OBJECT-BASED IMAGE COMPRESSION WITH SIMULTANEOUS SPATIAL AND SNR SCALABILITY SUPPORT FOR MULTICASTING OVER HETEROGENEOUS NETWORKS

Understanding the Limitations of Replaying Relay-Created COMTRADE Event Files Through Microprocessor-Based Relays

DELTA MODULATION AND DPCM CODING OF COLOR SIGNALS

Signal to noise the key to increased marine seismic bandwidth

New Efficient Technique for Compression of ECG Signal

An Effective Filtering Algorithm to Mitigate Transient Decaying DC Offset

OSL Preprocessing Henry Luckhoo. Wednesday, 23 October 13

A Parametric Autoregressive Model for the Extraction of Electric Network Frequency Fluctuations in Audio Forensic Authentication

Application of Wavelet Transform To Denoise Noisy Blind Signal Separation

Artifact Removal in Magnetoencephalogram Background Activity with Independent Component Analysis

LabView Exercises: Part II

Quantitative Evaluation of Artifact Removal in Real Magnetoencephalogram Signals with Blind Source Separation

LOCOCODE versus PCA and ICA. Jurgen Schmidhuber. IDSIA, Corso Elvezia 36. CH-6900-Lugano, Switzerland. Abstract

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

Design of Electrocardiography Signal Acquisition and Processing Software Module

PACKET-SWITCHED networks have become ubiquitous

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

2. AN INTROSPECTION OF THE MORPHING PROCESS

Channel models for high-capacity information hiding in images

Adaptive decoding of convolutional codes

POST-PROCESSING FIDDLE : A REAL-TIME MULTI-PITCH TRACKING TECHNIQUE USING HARMONIC PARTIAL SUBTRACTION FOR USE WITHIN LIVE PERFORMANCE SYSTEMS

IJESRT. (I2OR), Publication Impact Factor: 3.785

Analysis of Packet Loss for Compressed Video: Does Burst-Length Matter?

AGH University of Science and Technology Measurement & Instrumentation Department Kraków, Poland

Transcription:

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 12, Issue 3 Ver. IV (May June 2017), PP 30-35 www.iosrjournals.org Removal of EMG Artifacts from Multichannel EEG Signal Using Automatic Dynamic Segmentation and Adaptive Thresholding with Multilevel Decomposed Wavelets K.P. Paradeshi 1, Research Scholar, Professor Dr. U.D. Kolekar 2, 1 Associate Professor, PVPIT, Budhgaon Sangli, Maharashtra. 2 Professor and Principal, APSIT, Thane. Mumbai, Maharashtra. Abstract: Background: Like the brain, muscles also generate electrical signals. These signals are picked up by EEG electrodes and become muscle artifacts in EEG recording. MA is looking like fast oscillations. EEG signals disturbed by MA have larger amplitudes than normal EEG signals. Human beings have a large number of muscles all over their bodies. The muscle movement that happens near electrodes, such as teeth squeezing, jaw clenching, forehead movements will have a huge impact on the power spectrum of EEG signals. Usually, presence of the MA in EEG signals will increase the power of EEG signals in the frequency band from roughly 20Hz to 50Hz. Materials and methods: 16 channel EEG signals are acquired with EMG artifacts. The subject is instructed to do jaw clenching, forehead movement, teeth squeezing at different instances during the time of recording. The captured EEG signal is imported in MATLAB. Sampling rate used is 1024 Hz. Statistical parameters like PSNR, RMSE are used for comparison. EMG artifacts frequently affected the EEG signal and contaminated valuable information. The present work deals with novel automatic dynamic size independent components based on statistical information of signal and development of multilevel decomposition with adaptive threshold for removing of EMG artifacts. Automatic and dynamic segmentation is the major feature of this method. A particular segment can be analyzed and processed independent of other segments. The present adaptive threshold method is best suitable for removal of muscle artifacts. Results: Present method is better for suppression of EMG artifacts and preserves brain neural activity information as compared with static segmentation. Conclusion: Automatic dynamic segmentation method with adaptive thresholding of multilevel decomposed wavelets is showing superior performance over conventional static segmentation method. It removes EMG artifacts significantly by preserving brain neural activity. Keywords: Adaptive threshold, muscle artifacts, Automatic segmentation, RMSE, dynamic partition, PSNR. I. Introduction The disturbing myogenic activity not only powerfully affects the visual analysis of EEG, but also most certainly impairs the results of EEG signal processing tools such as source localization. This discussion focuses on the particular context of the contamination epileptic signals (interictal spikes) by muscle artifact, as EEG is a key diagnostic tool for this pathology. In this context, the aim was to evaluate the ability of two stochastic approaches of blind source separation, namely independent component analysis (ICA) and canonical correlation analysis (CCA), and of two deterministic approaches, namely empirical mode decomposition (EMD) and wavelet transform (WT) to remove muscle artifacts from EEG signals. To quantitatively compare the performance of these four algorithms, epileptic spike-like EEG signals were simulated from two different source configurations and artificially contaminated with different levels of real EEG-recorded myogenic activity. The efficacy of CCA, ICA, EMD, and WT to correct EMG artifact was evaluated both by calculating the normalized MSE between denoised and original signals and by comparing the results of source localization obtained from an artifact-free as well as raw signals, before and after artifact correction.tests on real data recorded in an epileptic patient are also presented. The results obtained in the context of simulations and real data show that EMD outperformed the three other algorithms for the denoising of data highly contaminated by muscular activity. For less noisy data, and when spikes arose from a single cortical source, the myogenic artifact was best corrected with CCA and ICA. Otherwise when spikes originated from two distinct sources, either EMD or ICA offered the most reliable denoising result in highly noisy data, while WT offered the better denoising result for less noisy data. These results suggest that the performance of muscle artifact correction methods strongly depends on the level of data contamination, and of the source configuration underlying EEG signals [1]. A novel technique (Automatic Wavelet Independent Component Analysis, AWICA) for automatic EEG artifact removal is presented. AWICA is based on the joint use of the Wavelet Transform and of ICA.It DOI: 10.9790/1676-1203043035 www.iosrjournals.org 30 Page

consists of a two-step procedure relying on the concepts of kurtosis and Renyi s entropy. Both synthesized and real EEG data are processed by AWICA and the results achieved were compared to the ones obtained by applying to the same data the wavelet enhanced ICA method recently proposed by other authors. Simulations illustrate that AWICA compares favorably to the other technique. The method here proposed is shown to yield improved success in terms of suppression of artifact components while reducing the loss of residual informative data, since the components related to relevant EEG activity are mostly preserved [2]. A new method for muscle artifact removal in EEG is presented, based on canonical correlation analysis (CCA) as a blind source separation (BSS) technique. This method is demonstrated on a synthetic data set. The method outperformed a low-pass filter with different cutoff frequencies and an independent component analysis (ICA) based technique for muscle artifact removal. In addition, the method is applied to a real ictal EEG recording contaminated with muscle artifacts. The proposed method removed successfully the muscle artifact without altering the recorded underlying ictal activity [3,7]. The methods of wavelet threshold denoising and independent component analysis (ICA) are introduced. ICA is a novel signal processing technique based on high order statistics, and is used to separate independent components from measurements. The extended ICA algorithm does not need to calculate the higher order statistics, converges fast, and can be used to separate subgaussian and supergaussain sources. A prewhitening procedure is performed to decorrelate the mixed signals before extracting sources. The experimental results indicate the electromyograpm (EMG) and electrocardiograh (ECG) artifacts in electroencephalograph (EEG) can be removed by a combination of wavelet threshold denoising and ICA [4]. The electroencephalogram (EEG) signals were usually contaminated by electromyography (EMG) signals. Multivariate empirical mode decomposition (MEMD) based method is proposed to remove EMG artifacts from the EEG signals. Firstly, the EEG signals were decomposed by the MEMD into multiple multivariate intrinsic mode functions (MIMFs) with different frequency bands. Then the power spectra were calculated for every MIMF by using the Welch method. Because the power spectrum of EEG and EMG were focused on different frequency ranges, the MIMFs which included the EMG artifacts could be got rid of. Finally, the clean EEG could be reconstructed by the remaining MIMFs. In this study, the MEMD-based method was used to remove the EMG artifacts for different signal-to-noise ratio (SNR). The experimental results indicated that the SNR of EEG signals could be obviously improved in different conditions and the mean square error (MSE) of EEG signals also could be significantly reduced [5]. The artifacts appear as noise in the recorded EEG signal individually or in a combined manner. Usually physicians are misled by these noisy signals and the EEG analysis can go wrong. Removal of noise signal which can be EMG, ECG or a combination of these two artifacts from the corrupted EEG signal and also signal enhancement both using recurrent learning technique are carried out. For this purpose RTRL (Real Time Recurrent Learning) algorithm is implemented which is the most recent and sophisticated real time neural network algorithm [6]. II. Methodology 16 channel EEG signals are acquired with EMG artifacts. The subject is instructed to do jaw clenching, forehead movement, teeth squeezing at different instances during the time of recording. The captured EEG signal is imported in MATLAB. Sampling rate used is 1024 Hz. Statistical parameters like Standard deviation, PSNR, RMSE are used for comparison. EMG artifacts frequently affected the EEG signal and contaminated valuable information. Dynamic segmentation is carried out to partition the EEG signal into a number of independent components. Segments are unequal length and automatic segmentation is done using the property of stationary waves, hence, called as dynamic segments. EEG signal is non-stationary but within segments, each IC has unique stationary properties. Global threshold value (GTV) of raw EEG is calculated using the property of mean, median and standard deviation. Out of these threshold values the numerical maximum selected as GTV. Two levels Discrete Wavelet Transform (DWT) of each IC is taken using HAAR wavelet family. One IC is first decomposed into four wavelets. It computes the approximation coefficients matrix ca and details coefficients matrices ch, cv, and cd (horizontal, vertical, and diagonal, respectively), obtained by wavelet decomposition of the input matrix.successive DWT is taken of the decomposed wavelets. Thus, the wavelets are distributed as 4 wavelets for first decomposition, 16 wavelets for second decomposition, 64 wavelets for third decomposition, 256 wavelets for fourth decomposition, and 1024 wavelets for fifth decomposition. This process of n th decomposition is restricted to size of RAM memory and processing power of central processing unit. Hence, 3 to 5 decomposition is sufficient to greater accuracy. n=1 is the normal wavelet based method. Local Threshold Value (LTV) is calculated using mean, median and standard deviation of decomposed wavelets. Numerical maximum out of these selected as LTV. Total number of LTV is equal to number of wavelets M. GTV and LTV are relative to the DWT method as decomposition progressed, previously calculated LTV treated as GTV in the next decomposition. Threshold means replacement of the values in the DOI: 10.9790/1676-1203043035 www.iosrjournals.org 31 Page

wavelets greater than LTV with new value ε. It is categorised depending on the value of ε. ε=0, µ, GTV and spatial called respectively as zero replacement threshold, mean replacement threshold, maximum level threshold and co-ordinate to co-ordinate spatial replacement threshold in this literature. Zero replacement threshold removes all information where as it is assumed to be the original information lies in between mean and GTV. Threshold is carried out at highest (suppose n=5, at 5 th decomposition) decomposed wavelets and after completion of process; Inverse DWT (IDWT) is taken whenever move to lower decomposition. Spatial threshold is implemented as progressed to lower decomposed (n=5 to 4, 4 to 3, 3 to 2 and 2 to 1 decomposition) wavelets. At the 1 st decomposition, it is replaced with spatial data which is better estimation of original data in the artifact zone. Final clean EEG is obtained by IDWT of first decomposed wavelet. III. Dynamic Segmentation EEG is non-stationary signal which does not possess certain properties of statistics. A stationary signal is significant in the signal processing due to its predefined statistical property. As EEG is non-stationary, it is partitioned into number of segments in which within that segments signal possess stationary property. These segments are treated as independent components of EEG signal. Analysis and processing of EEG segments provides noise filtering, artifacts removing and many more applications. A segment is valid, if it satisfies law of statistics for stationary signal. Analysis of non-stationary segments results into uncorrelated data and loss of valuable certain information within that segment. Equal size segments do not hold property of stationary signal. Equal size static segmentation method is not suitable for EEG signal processing. Hence, unequal size or dynamic segmentation is desirable. Nonstationarity of signal can be quantified on the regular time lags by measuring statistics of the signal. The signal within time lag deemed as stationary if there is no considerable variation in these statistics. Skewness, Kurtosis and discriminate are the measure statistical property of time lag provides the information regarding signal. These parameters are vital in the determination of segments and artifacts present in the signal. Skewness is a measure of symmetry or, more precisely, the lack of symmetry of the distribution. A distribution, or data set, is symmetric if it looks the same to the left and right of the center point. The skewness is defined for a real signal as, (1) Algorithm for automatic segmentation is as follows, I: Take channel as counter. Initially select first channel. II: obtain number of Rows(R) and column (C) of channel. III: Initialize a variable to store RowStart of each segment. IV: Take maximum row as counter V: calculate skewness and calculate difference of current and old values of skewness. VI: if difference is greater than 0.5 then mark the current row as end of segment and (row +1) as start of new segment. Store the values of skewness as old segment values. VII: repeat V to VI to last row. VIII: store the RowStart to the memory IX: repeat II to VIII to last channel. Wavelet threshold process is used to remove EMG artifacts present in the EEG signal. Threshold means replacing current data which is greater than threshold value with the new value. Threshold value is calculated as, (2) (3) N=100, mad=median absolute deviation of signal (4) Threshold value is the numerical maximum of. Selection of the threshold value is an essential element of the algorithm. Here simple fixed form threshold can be used. (5) where N is the length of the data segment to be processed, and σ 2 = median ( W(d, b) ) / 0.6745 is the estimator of the magnitude of the neural wide band signal part. DOI: 10.9790/1676-1203043035 www.iosrjournals.org 32 Page

IV. Results And Discussion Mainly three different types of artifacts are considered for analysis. Table 1 shows the values of PSNR and RMSE of Subject 1 and Subject 2 due to jaw clenching artifact. Table 2 shows the values of PSNR and RMSE of Subject 3 and Subject 4 due to teeth squeezing artifact. Table 3 shows the values of PSNR and RMSE of Subject 5 and Subject 6 due to forehead movement artifact. Figure 1 shows the raw EEG signal with jaw clenching artefact and Figure 2 shows the clean EEG signal after removal of jaw clenching artifact. Figure 3 shows the raw EEG signal with teeth squeezing artifact and Figure 4 shows the clean EEG signal after removal of teeth squeezing artifact. Figure 5 shows the raw EEG signal with forehead movement artifact and Figure 6 shows the clean EEG signal after removal of forehead movement artifact. For Subject 1 PSNR value is 3.16 whereas RMSE is 25.71 for jaw clenching artifacts. Actually statistically results are dependent upon how heavily artifacts are buried in the signal. Automatic dynamic segmentation method is powerful new technique for removal of EMG artifacts. Clearly we can visualize the correction made by this method for removal of different EMG artifacts as shown in Figure 1 to Figure 6. Table 1: Results of EMG artifact due to Jaw Clenching Subject(s) PSNR RMSE Subject 1 3.16 25.71 Subject 2 3.862 22.77 Figure 1: Raw EEG signal with jaw clenching EMG artifacts Subject1 Figure 2: Clean EEG signal after removal of jaw clenching EMG artifacts of Subject 1 Table 2: Results of EMG artifacts due to teeth squeezing Subject(s) PSNR RMSE Subject 3 7.8767 16.99 Subject 4 5.6916 17.50 DOI: 10.9790/1676-1203043035 www.iosrjournals.org 33 Page

Figure 3: Raw EEG signal with teeth squeezing EMG artifacts of Subject 3 Figure 4: Clean EEG signal after removal of teeth squeezing EMG artifacts of Subject 3 Table 3: Results of EMG artifacts due to forehead movements Subject(s) PSNR RMSE Subject 5 11.9759 24.99 Subject 6 11.1842 22.69 Figure 5: Raw EEG signal with forehead movement EMG artifact of Subject 5 Figure 6 Clean EEG signal after removal of forehead movement EMG artifact of Subject 5 DOI: 10.9790/1676-1203043035 www.iosrjournals.org 34 Page

Table 4 shows the results of PSD and Standard Deviation of raw EEG signal and clean EEG signal for different types of EMG artifacts. These performance parameters are used for analysis of different types of artifacts. Mainly Subject 1 and Subject 2 are showing the vales for jaw clenching EMG artifacts. For Subject 1 PSD of Raw EEG signal is 17.468 whereas PSD of clean EEG signal is 13.5021.Similarly Standard deviation values are 17.3772 for raw EEG signal and 6.0837 for clean EEG signal are tabulated. Subject 3 and Subject 4 are concerned with Teeth squeezing artifacts and their values are also tabulated in table 4.Forehead movement EMG artifacts is concerned with Subject 5 and Subject 6.Raw EEG signals are having higher values of PSD and standard deviation whereas clean EEG signals are having lower values of PSD and standard deviation. We have also obtained the minimum values of RMSE. Table 4 Results of PSD and Standard Deviation of raw EEG signal and clean EEG signal. Subject(s) Type of EMG Artifacts PSD of Raw EEG in db PSD of Clean EEG in db Standard Deviation of Raw EEG Standard Deviation of Raw EEG Subject 1 Jaw clenching 17.468 13.5021 17.3772 6.0837 Subject 2 Jaw clenching 22.7844 19.4531 9.7918 3.4885 Subject 3 Teeth squeezing 21.3917 14.7326 6.1659 5.8379 Subject 4 Teeth squeezing 22.2516 17.4126 6.9151 5.44 Subject 5 Forehead Movement 29.2146 22.5581 17.2508 8.4881 Subject 6 Forehead Movement 26.6826 21.76 15.1939 8.0253 V. Conclusion Results obtained using present method is more promising as compared to earlier methods. Lower values of RMSE and higher values of PSNR means artifacts are suppressed predominantly. Automatic dynamic segmentation and adaptive thresholding with multilevel decomposed wavelets is best suited for removal of different types of EMG artifacts. The said method is showing superior performance over conventional static segmentation method. Raw EEG signals are having higher values of PSD and standard deviation whereas clean EEG signals are having lower values of PSD and standard deviation. It indicates that after applying the said techniques different types of EMG artifacts mentioned in the study are greatly suppressed. References [1]. Safieddine et al. EURASIP Journal on Advances in Signal Processing 2012, 2012:127. [2]. Nadia Mammone, Fabio La Foresta, Carlo Morabito, Automatic Artifact Rejection From Multichannel Scalp EEG by Wavelet ICA, IEEE SENSORS JOURNAL, VOL. 12, NO. 3 MARCH 2012. [3]. Wim De Clercq, Anneleen Vergult, Bart Vanrumste, Wim Van Paesschen, Sabine Van Huffel, Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram, IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING,2006. [4]. Weidong Zhou, Jean Gotman, Removal of EMG and ECG Artifacts from EEG Based on Wavelet Transform and ICA, Proceedings of the 26th Annual International Conference of the IEEE EMBS San Francisco, CA, USA September 1-5, 2004. [5]. Chaolin Teng, Yanyan Zhang, Gang Wang, The Removal of EMG Artifact from EEG Signals by the Multivariate Empirical Mode decomposition, 978-1-4799-5274-8/14/20l4 IEEE. [6]. H. N. Suresh, C. Puttamadappa, Removal OF EMG and ECG artifacts from EEG based on real time recurrent learning algorithm, International Journal of Physical Sciences Vol. 3 (5), pp. 120-125, May, 2008. [7]. Xun Chen, Chen He, Hu Peng, Removal of Muscle Artifacts from Single-Channel EEG Based on Ensemble Empirical Mode Decomposition and Multiset Canonical Correlation Analysis, Journal of Applied Mathematics, Hindawi Publishing Corporation, Volume 2014, Article ID 261347, 10 pages, http://dx.doi.org/10.1155/2014/261347. DOI: 10.9790/1676-1203043035 www.iosrjournals.org 35 Page