OPTEVA 868 THROUGH THE WALL ATM WITH mm ( 2") CEN-L SAFE L00 CALL -800-999-600 22 (9 6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-826-00A. 42 6") ( 6 (4") 8 SAFE AND HINGES (2 6") 80 SAFE ( 6 (4") 0 PAGE OF 6 9 6") ( 6") (2 (9 OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL 26 (49 W ITH ILLUMINATED SIGNAGE PANEL FASCIA 08 4 (42 4") 22 ( 8 W.O. (2") 8 FASCIA ( 4") PLAN VIEW 8FASCIA ( 4") 22 ( OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) SEE SHEET 2 OF 6 SEE WALL OPENING DETAIL FOR RECOMMENDED CLEARANCE REQUIRED AROUND FASCIA. 262 TOP OF TOUCH SCREEN 6") (49 0mm (2") MAXIMUM OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL 26 (49 W ITH ILLUMINATED SIGNAGE PANEL FASCIA 08 4 (42 4") NOTE: FOR VARIOUS FASCIA CONFIGURATIONS AND CONSUMER ACCESS DIMENSIONS SEE PAGE 6 OF 6 W.O. 0 4 6") (40 (2") SEE W ALL OPENING NOTE 0mm (2") MAXIMUM 0 (9 6 (2 6") AIR VENT 2 (2 24 80 6") (8 6") ( 49 (6") FILE NO. -604 REV. WALL OPENING NOTE : INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION FOR LOCATING WALL OPENING WILL HAVE TO BE ADJUSTED ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL NOT BE MET. EXTERIOR ELEVATION MAX. WALL HOLD 0 (2") (2 6") 0 8 ( 2") 0 SAFE (9 44 ( 2") VERTICAL SECTION 42 (
R 2 4 CONDUIT AND JUNCTION BOX REQUIREMENTS NOTE: 2mm (") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 02mm (4") SQ. X 4mm (2 DEEP JUNCTI0N BOX (ALL BY OWNER'S E.C.). DIEBOLD TO PROVIDE FLAT COVER WITH TAMPER SWITCH. WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO ATM, OWNER'S E.C. TO RUN 9mm ( 4") METAL CONDUIT FROM 02mm (4") SQ. X 4mm (2 DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. OWNER'S E.C. TO RUN 9mm ( 4") LIQUID TIGHT FLEX METAL CONDUIT OR 9mm ( 4") RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE. 9mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 02mm (4") SQ. X 4mm (2 DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 220 ( OF SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS). OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2,84 (86") FROM SIDE OF UNIT. JUNCTION BOXES MUST BE LOCATED WITHIN 220mm ( OF CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. BUILDING AIR PRESSURE BUILDING AIR PRESSURE DIFFERENCES AT THE ATM INSTALLATION LOCATION AFFECT THE INFILTRATION OF OUTSIDE AIR AND ACCOMPANY DIRT. THE ATM WILL OPERATE THROUGH ITS FULL RANGE OF FASCIA TEMPERATURES -4º C TO 4º C (-29º F TO 29º F) WITH ZERO (STATIC) OR POSITIVE AIR PRESSURE DIFFERENTIAL (MEASURED FROM THE INSIDE TO THE OUTSIDE OF THE BUILDING AT THE ATM INSTALLATION LOCATION). IF STATIC OR POSITIVE AIR PRESSURE CANNOT BE MAINTAINED, THE FASCIA LOWER LIMIT TEMPERATURE IS -20º C (-4º F). THE MAXIMUM NEGATIVE AIR PRESSURE ALLOWED IS 0.0" H O. SIGNAL CABLE RUN CONSTRAINTS THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. TYPE OF ELECTRICAL RUN FLUORESCENT, NEON OR INCANDESCENT LIGHTING FIXTURES UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT SEPARATION FROM OTHER CABLES BELOW 2 KVA 2- KVA ABOVE KVA 2mm (") 2mm (") 2mm (") 2mm (") 0mm ('-0") 60mm (2'-0") POWER REQUIREMENTS: THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW. 00-2 VAC (+6%, -0%) AT 0 (±%) Hz, SINGLE-PHASE 00-2 VAC (+6%, -0%) AT 60 (±%) Hz, SINGLE-PHASE 200-240 VAC (±0%) AT 0 (±%) Hz, SINGLE-PHASE 200-240 VAC (±0%) AT 60 (±%) Hz, SINGLE-PHASE POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. 00-2 VAC (+6%, -0%) SERVICE, DISCONNECT AT 20 AMPERES 200-240 VAC (±0%) SERVICE, DISCONNECT AT 0 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6000-4-. POWER USAGE MACHINE STATUS WITH HEATER IDLE (NO TRANSACTION) 24 WATTS 4 WATTS TRANSACTION (DISPENSE 0 WATTS 80 WATTS OR BULK NOTE) IN PROGRESS RAPID PROCESSING 422 WATTS 922 WATTS TRANSACTION IN PROGRESS CONFIGURATION IDMbd, 4 HIGH AFD, AND RAPID PROCESSING SYSTEMS CONFIGURED FOR SIMULTANEOUS IDM (INTELLIGENT DEPOSITORY MODULE) AND (ENHANCED CASH RECYCLING MODULE) OPERATIONS. THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE ATM, AND THE TYPE OF TRANSACTION THE ATM IS PERFORMING. VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED. HEAT OUTPUT CONFIGURATION PROCESSOR, SVD, MOTORIZED CARD READER, JOURNAL PRINTER, 80mm RECEIPT PRINTER, 2 BTU/HR IDLE WITH HEATER 240 BTU/HR TRANSACTION WITH HEATER 46 BTU/HR RAPID PROCESSING WITH HEATER OPERATING ENVIRONMENT: SAFE LOCATION 0º C TO 8º C (0º F TO 00º F) RELATIVE HUMIDITY (NON-CONDENSING) 20 TO 80% AT 2º C (90º F), 20 TO % AT 8º C (00º F) WEIGHT OF UNIT: 9kg (2,0 LBS.) UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT 64mm (2 2") 2mm (6") 0mm ('-0") 0mm ( 6") 6mm (") 2mm (6") CAUTION LABEL SIGNAL CABLE INSTALLATION CONSTRAINTS: RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION PAGE 2 OF 6 AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. 0 89 ( 2") 4 ( 4") 4 (6 6") 40 6") 9 ( 4 ( 08 4") (4 20 (2 (2 2") AIR VENTS AIR VENTS 2 4 4 9 6") (4 49 9 (6") ( SERVICE DOOR FILE NO. -604 REV. 80 SAFE ( BACK ELEVATION VERTICAL SECTION
WALL OPENING DETAIL NO. -604 REV. PAGE OF 6 RFILE W.O. 0 4 REQUIRED FOR WALLS EXCEEDING 0mm (2") 6") (40 (2") 4 ( 6") 22 (9 6") 8 (2") 8W.O. (2") PLAN VIEW PROVIDE VERTICAL AND HORIZONTAL FLAT PLUMB SURFACE AROUND WALL OPENING FOR PROPER INSTALLATION OF THE ATM ( 6") 96 6 ( 6 (") 8 W.O. (") SEE W ALL OPENING NOTE (2") 6 6 (") (") 06 0mm (2") MAXIMUM 6") (2 400 ( REQUIRED W HEN LIGHT PANEL IS INSTALLED W.O. 0 4 6") (40 (2") SEE W ALL OPENING NOTE 0mm (2") MAXIMUM WALL OPENING NOTE: INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION FOR LOCATING WALL OPENING WILL HAVE TO BE ADJUSTED ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL NOT BE MET. VERTICAL SECTION EXTERIOR ELEVATION
REQUIRED MINIMUM SERVICE AREA REQUIRED MINIMUM SERVICE AREA ALL ELECTRICAL AND DATA CABLES MUST ENTER UNIT IN THIS AREA NOTE: SHOWN IS THE REQUIRED MINIMUM AREA FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE REQUIRED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. 6 (4") 840 (2 6") 80 SAFE ( 6 (4") 8 (2 2") PAGE 4 OF 6 4 ( 6") 8 6 (4") 244 (4 6") 0 (4 8 8 ") (4 (96 8 ") 6") 2 ( 6") 8 ( 4") 2 ( 6") 2 FILE NO. -604 REV. (9 PLAN VIEW - REQUIRED MINIMUM SERVICE AREA
4 ( 4") 80 ( 9 (28 6") 40 9 2 ( 6") CABLE ENTRY OPENING NOTE 40 (29 CABLE ENTRY (SEE NOTE) 0 8 2") ( 0 (9 ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE ATM PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING ENTERS FROM THE SIDE OF THE ATM. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH DISPENSER. POWER CABLE PLATE 29mm ( DIA. HOLE FOR ALARM CABLES (SIDE ENTRY) OPENING FOR POWER CORD AND DATA CABLES (SIDE ENTRY) OWNER'S INSTALLER TO DRILL (4) 9mm ( 4") DIA. X 20mm (8" MIN.) DEEP HOLES IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4) 9mm ( 4")-0 X 20mm ( LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) DIEBOLD PART NUMBER 29-066-000A, HILTI PART NUMBER 28220). 20MIN. ( 02 (4") MIN. 9 ( 2") PLAN/SECTION - SAFE FLOOR - (4) 2.4mm (") DIA. FLOOR MOUNTING HOLES NOTES: FOR ADDED SECURITY: IT IS RECOMMENDED THAT THE ATM SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR YOUR INSTALLATION. ANCHORING THE ATM TO CONCRETE FLOORS: IT IS RECOMMENDED THAT THE ATM BE ANCHORED TO CONCRETE FLOORS WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 9mm ( 4") ANCHOR BOLT THAT IS 20mm ( LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 02mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE ATM IS EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE ATM IS ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS. PAGE OF 6 FILE NO. -604 REV. VIEW "A" MINIMUM HOLE 20mm ( VIEW "B" MINIMUM CONCRETE 02mm (4")
CONSUMER ACCESS DIMENSIONS TOP OF TOUCH SCREEN TOP FUNCTION KEY COIN DOOR BAR CODE SCANNER RECEIPT PRINTER CARD READER IDMbd LOWER KEYPAD (MIDDLE EPP KEY) ADVANCED FUNCTION DISPENSER TOP OF TOP ADVANCED RECEIPT KEYPAD IDMbd CARD BAR CODE COIN TOUCH FUNCTION FUNCTION PRINTER (TOP EPP KEY) LOWER READER SCANNER DOOR SCREEN KEY DISPENSER 262 9 26 96 2 8 49 84 09 9 889 2 9 2 0 2 08 2 (49 6") (2 6") (4 (0 4") ( 6") (8 ( 4") ( 6") ( 6") (4 4") (2 ( 6") (") (8 (8 6") (8 (40 4") (8 (42 6") (8 - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF BEZEL TOP OF TOUCH SCREEN TOP FUNCTION KEY IDMbd UPPER LCD BAR CODE SCANNER PASSBOOK PRINTER CARD READER RECEIPT PRINTER KEYPAD (MIDDLE EPP KEY) ADVANCED FUNCTION DISPENSER PAGE 6 OF 6 TOP OF TOUCH SCREEN TOP FUNCTION KEY 262 (49 6") (2 6") 9 (4 26 (0 4") - FROM BOTTOM OF SAFE PASSBOOK PRINTER 96 ( 6") - FROM FRONT EDGE OF BEZEL 2 (8 8 ( 4") 49 ( 6") KEYPAD (TOP EPP KEY) 84 ( 6") 09 (4 4") ADVANCED FUNCTION DISPENSER (2 9 ( 6") RECEIPT PRINTER 88 (4 4") 2 (8 899 CARD READER ( 2 (8 BAR CODE SCANNER IDMbd UPPER 0 (40 4") 2 (8 28 (4 2 (8 IDM V UPPER IDMbd LOWER FILE NO. -604 REV. 889 IDM V LOWER (0") 2 (8 IDM V UPPER 28 (4 2 (8 - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF BEZEL