OPERATION MANUAL. UF-112 Universal Frame. UF-112PS Power Supply Module. 2 nd Edition - Rev.1

Similar documents
OPERATION MANUAL. UFM-30DDA Digital Distribution Amplifier. UFM-3DDAEX Expansion Card. 2 nd Edition - Rev.2 Software Version 1.

USO RESTRITO. UFM-147DFS Frame Synchronizer and Time Base Corrector. 1 st Edition - Rev. 4

OPERATION MANUAL. UFM-147DFS Frame Synchronizer and Time Base Corrector. 1 st Edition - Rev. 4

OPERATION MANUAL. HVS-AUX16A HVS-AUX32A HVS-AUX64A Auxiliary Unit. 3 rd Edition

OPERATION MANUAL. UFM-30UDC Digital Up/Down/Cross Converter. 2 nd Edition

OPERATION MANUAL. USF-402AADC Audio Analog Digital Converter. 1 st Edition

2 M/E - 3 M/E Digital Video Switcher. HVS-4000 Series

HDV for LIVE MC-10AD. The Best Gear for HDV Camcorder LIVE Applications. HD/ SD A D C onve rte r

OPERATION MANUAL. UFM-30FRC HD/SD/Analog Composite Frame Rate Converter. 1 st Edition - Rev.1

USO RESTRITO. UFM-30FRC HD/SD/Analog Composite Frame Rate Converter. 1 st Edition - Rev.1

HVS-300HS "1M/E HANABI Portable"

Model 1421 Distribution Amplifier

OPERATION MANUAL. HVS-30RU Remote Unit. HVS-30FP Front Panel. 3 rd Edition

OPERATION MANUAL. MV-410RGB Multi Viewer. 3 rd Edition Rev. 2

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

HD/SD 1 M/E - 2 M/E Video Switcher HVS-390HS HANABI. HD/SD 1 M/E - 2 M/E Video Switcher HVS-390HS HANABI

OPERATION MANUAL. MV-410RGB Multi Viewer. 3 rd Edition Rev. 2 USO RESTRITO

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

DISTRIBUTION AMPLIFIER

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

12G/3G/HD/SD/ASI Routing Switcher MFR-5000/ G/3G/HD/SD/ASI Routing Switcher MFR-5000/8000

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

Operating Instructions

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

HMV160 High-definition Multi-viewer Display Processor USER MANUAL

OPERATION MANUAL. USF-1013DEMUX Digital Audio Demultiplexer. 2 nd Edition. Software Version Higher

HD/SD 1M/E Digital Video Switcher HVS-1000HS "1M/E HANABI"

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

OPERATION MANUAL. HVS-AUX8 Auxiliary Unit HVS-AUX16 HVS-AUX32. S/N Higher. S/N Higher. 9 th Edition (Version 4.

TBC & Matrix Switcher TBC-5000 Instruction Manual

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

PLL1920M LED LCD Monitor

TM-A9U TM-A9UCV COLOR VIDEO MONITOR INSTRUCTIONS

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

/ PAT01 USER MANUAL

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

ARS x4 MATRIX SWITCHER Instruction Manual

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

HD/SD 1M/E Digital Video Switcher HVS-1000HS "1M/E HANABI"

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

SDP-RFD AC-3 /RF DEMODULATOR (120V/230V) INSTALLATION/ TECHNICAL MANUAL

All In One. FA-9100/RPS "THE Processor" FA-9100/RPS. Multi Purpose Signal Processor

TM-A130SU INSTRUCTIONS COLOR VIDEO MONITOR TM-A130SU

.Power Distribution Center. PD-1. Instruction Manual

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

CM-S23349SV. Vari-Focal IR Bullet Camera

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

Outdoor IR Audio Camera

CM-S38901SV TVL IR Long Range camera

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

HVS-350HS "1.5M/E HANABI"

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

DA VGA Line Receiver User s Guide

Winmate Communication INC.

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

SAC6840N 2X1 Switcher USER MANUAL

Monochrome Video Monitors

28 4K LED monitor. User Manual M284K

TM-A13SU TM-A13UCV TM-A13SU-W INSTRUCTIONS COLOR VIDEO MONITOR

P-2 Installing the monitor (continued) Carry out as necessary

LT 4448 CHANGEOVER. Instruction Manual. Thank you for purchasing.

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

DIGI-BSR-4K Installation Guide

HVS-350HS "1.5M/E HANABI"

Model Camera System (CCTV) User Manual

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

17 /19. User's Manual

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

USER MANUAL Full HD Widescreen LED Monitor L236VA

VITEK VTM-TLM191 VTM-TLM240

E3/DS3 Fibre Extender

Electric Motorized Projection Screen PowerMax Tension Series

User Guide. Centrex Recording Interface

PLL2210MW LED Monitor

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Power Injector 1520 Series

DS / /113. Pair (TP) User s Guide

TFT LCD MONITOR USER MANUAL. L80AP and L101AP

VLHDMIEXTFIB_2017V1.0

9" B/W MONITOR CEM-09/09A-2 12" B/W MONITOR CEM-12/12A-2 OPERATION MANUAL

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

User Manual POE. Twisted Pair POE Extender

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

HD/SD Portable Video Switcher. HVS-300HS/300RPS "1M/E HANABI Portable" HD/SD Portable Video Switcher HVS-300HS/300RPS. "1M/E HANABI Portable"

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

User Manual Color video door phone

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

USER MANUAL Full HD Widescreen LED Monitor L215IPS

Transcription:

OPERATION MANUAL UF-112 Universal Frame UF-112PS Power Supply Module 2 nd Edition - Rev.1

Precautions Important Safety Warnings [Power] Caution Operate unit only on the specified supply voltage. Disconnect power cord by connector only. Do not pull on cable portion. Stop [Grounding] Do not place or drop heavy or sharp-edged objects on power cord. A damaged cord can cause fire or electrical shock hazards. Regularly check power cord for excessive wear or damage to avoid possible fire / electrical hazards. Caution Hazard Ensure unit is properly grounded at all times to prevent electrical shock hazard. Do not ground the unit to gas lines, units, or fixtures of an explosive or dangerous nature. Ensure power cord is firmly plugged into AC outlet. Caution [Operation] Hazard Hazard Do not operate unit in hazardous or potentially explosive atmospheres. Doing so could result in fire, explosion, or other dangerous results. Do not allow liquids, metal pieces, or other foreign materials to enter the unit. Doing so could result in fire, other hazards, or unit malfunction. [Transportation] If foreign material does enter the unit, turn power off and disconnect power cord immediately. Remove material and contact authorized service representative if damage has occurred. Caution Handle with care to avoid shocks in transit. Shocks may cause malfunction. When you need to transport the unit, use the original packing materials or alternate adequate packing.

[Circuitry Access] Do not remove covers, panels, casing, or access circuitry with power applied to the unit! Turn power off and disconnect power cord prior to removal. Internal servicing / adjustment of unit should only be performed by qualified personnel. Stop Do not touch any parts / circuitry with a high heat factor. Capacitors can retain enough electric charge to cause mild to serious shock, even after power is disconnected. Capacitors associated with the power supply are especially hazardous. Avoid contact with any capacitors. Hazard Unit should not be operated or stored with cover, panels, and / or casing removed. Operating unit with circuitry exposed could result in electric shock / fire hazards or unit malfunction. [Potential Hazards] Caution If abnormal smells or noises are noticed coming from the unit, turn power off immediately and disconnect power cord to avoid potentially hazardous conditions. If problems similar to above occur, contact authorized service representative before attempting to again operate unit. [Rack Mount Brackets, Ground Terminal, and Rubber Feet] Caution To rack mount or ground the unit, or to install rubber feet, do not use screws or materials other than those supplied. Otherwise, it may cause damage to the internal circuits or components of the unit. If you remove the rubber feet attached on the unit, do not reinsert the screws securing the rubber feet. [Consumables] Caution The consumables used in unit must be replaced periodically. For further details on which parts are consumables and when they should be replaced, refer to the specifications at the end of the Operation Manual. Since the service life of the consumables varies greatly depending on the environment in which they are used, they should be replaced at an early date. For details on replacing the consumables, contact your dealer.

Upon Receipt Unpacking UF-112/UF-112PS units and their accessories are fully inspected and adjusted prior to shipment. Operation can be performed immediately upon completing all required connections and operational settings. Check your received items against the packing lists below. UF-112 ITEM QTY REMARKS UF-112 1 AC Cable 1 Operation Manual 1 UF-112PS ITEM QTY REMARKS UF-112PS 1 Front unit for redundant power supply, rear uint Screw 2 Front and rear units for 1ea. (bind, M3 x 6) AC Cable 1 Check Check to ensure no damage has occurred during shipment. If damage has occurred, or items are missing, inform your supplier immediately. Rack Mounting The UF-112 can be mounted to EIA standard rack units. When rack mounting a unit, remove the rubber feet and use the accessory rack mount brackets (rack ears).

Table of Contents 1. Prior to Starting... 1 1-1. Welcome... 1 1-2. About the UF-112/UF-112PS... 1 1-3. Features... 1 1-4. About This Manual... 1 2. Panel Descriptions... 2 2-1. Front Panel... 2 2-2. Front Interior... 2 2-3. Slot No.... 3 2-4. Rear Panel... 4 2-4-1. Rear Panel Slot... 4 2-4-2. Connecting Peripherals... 5 2-5. Cooling Fan... 6 2-6. Power Unit... 7 2-7. Connector... 8 2-7-1. Connector Specifications... 8 2-7-2. Alarm Output... 9 2-7-3. Connection Circuit Example... 11 3. Installation... 12 3-1. UFM Module Installation... 12 3-1-1. Rear UFM Module Installation... 13 3-1-2. Front UFM Module Installation... 14 3-2. Power Supply Installation... 16 3-2-1. Power Unit Installation... 16 3-2-2. Removing Power Unit... 18 4. Remote Power Monitoring... 20 5. Specifications and Dimensions... 21 5-1. Specifications... 21 5-2. External Dimensions... 22 5-2-1. UF-112... 22 5-2-2. UF-112PS... 23

1. Prior to Starting 1-1. Welcome Congratulations! By purchasing UF-112 Universal Frame you have entered the world of FOR-A and its many innovative products. Thank you for your patronage and we hope you will turn to FOR-A products again and again to satisfy your video and audio needs. FOR-A provides a wide range of products, from basic support units to complex system controllers, which have been increasingly joined by products for computer video based systems. Whatever your needs, talk to your FOR-A representative. We will do our best to be of continuing service to you. 1-2. About the UF-112/UF-112PS The UF-112 Universal Frame allows the building of any system at a low cost and a minimum of space. Up to twelve UFM modules can be installed. Installation of the optional redundant power supply allows increased safety during operation. 1-3. Features Up to twelve UFM modules (boards) can be installed to match system requirements. Installation of the UF-112PS enables a redundant power supply (dual power supply) configuration. All modules can be replaced from the front. Front power unit and front UFM module both support hot-swapping. Alarm sensors (Temperature Error/ Fan Stop/ Power Unit Voltage Error) and status indicators (GENLOCK/ Power) are shown on front LEDs. Alarm data can be output from rear connectors. (Two make-contact outputs and two open-collector outputs.) GENLOCK input (BB or Tri-Level Sync) with loop-through. (The input GENLOCK can be supplied to all UFM modules installed in the unit.) EIA standard 3RU size 1-4. About This Manual Before connecting or operating your unit, read this operation manual thoroughly to ensure you understand the product. After reading, it is important to keep this manual in a safe place and available for reference. 1

2. Panel Descriptions 2-1. Front Panel To remove the front panel, loosen the two knob screws on the front panel face, and then grasp the knob screws to pull them out. UF-112 UNIVERSAL FRAME 1 2 GENLOCK IN GENLOCK IN TEMP TEMP DC POW DC POW 2-2. Front Interior The slot configuration shown below is revealed when the front panel is removed. (1) (2) (4) (3) (5) GENLOCK ON IN TEMP OFF DC (1) Slot for Power Supply module Used to mount the front module of standard power supply. (2) Slot for Power Supply module Used to mount the front module of redundant power supply (UF-112PS). (3) Slots for UFM modules Used to mount the front modules of UFM cards. For the module operating procedures, refer to the respective module operation manual. (4) Slot for Control module Slot is dedicated to UFM-30CTL front module. (5) Fan unit Used to cool modules to prevent overheating. The fan motor should be checked regularly. Redundant Power System Two power units can be installed in the UF-112. The standard power unit is installed in slot (1) in the standard configuration. Slot (2) is an optional slot for the redundant power supply (UF-112PS). The power unit can be replaced without stopping the supply of power to the main unit, If a problem ever occurs in one of the power units, once the two power units are installed and the two power switches are turned on. 2

2-3. Slot No. The slots are numbered 1, 2, 3, 12 starting from the right side as viewed from the front. When one power unit is installed PS1 SLOT 7 SLOT 8 SLOT 1 SLOT 2 SLOT SLOT 9 SLOT 10 SLOT 11 SLOT 12 SLOT 3 SLOT 4 SLOT 5 SLOT 6 When two power units are installed PS1 PS2 SLOT 7 SLOT 1 SLOT 8 SLOT 2 SLOT SLOT 9 SLOT 10 SLOT 11 SLOT 12 SLOT 3 SLOT 4 SLOT 5 SLOT 6 3

2-4. Rear Panel 2-4-1. Rear Panel Slot The rear panel has the following slot configuration. (5) (4) (3) (2) (1) GENLOCK IN ALM AC100-240V ~ 50/60Hz IN RATING LABEL (1) Slot for Power Supply module See section 2-4-2. "Connecting Peripherals." (2) Slot for Power Supply module Used to mount the rear module of redundant power supply. See section 3-2-1. "Power Unit Installation" for power supply installation. (4) Slot for Control module Slot is dedicated to UFM-30CTL rear module. (4) Slots for UFM modules Used to mount the rear modules of UFM cards. (5)GENLOCK IN, CONNECTOR See section 2-4-2. "Connecting Peripherals." 4

2-4-2. Connecting Peripherals S/No. GENLOCK IN ALM 1 2 LAN RS-422 (10/100BASE-T) UFM-30CTL AC100-240V ~ 50/60 Hz IN RATING LABEL Installation example: UFM Rear Modules (9) (8) (7) (6) (5) (4) (3) ALM GENLOCK IN (2) (1) (1) GENLOCK inputs Used to input the external reference signal (Black Burst or Tri-Level Sync). The genlock signal is distributed to twelve internal modules. Bottom connector is a loopthrough of GENLOCK IN. The loopthrough connector must be 75 ohm terminated if it isn t connected to other system equipment. (2) indicator The indicator turns off during normal operation. If it lights up red, one or more fans fail. Power off the frame and replace the failed fan, if necessary. (3) connector Used to output the alarm signal indicating fan, power or temperture failure. See section 2-7. " Connector" for the connector pin assignments. (4) GND terminal To prevent an electrical shock, be sure to either connect the ground terminal to a ground wire or unplug the AC power cable from the AC outlet before performing any work. (5) AC IN (AC100V-240V 50/60Hz) Used for connection to AC power source via supplied cable. (6) Power unit screw Used to secure the power unit. See section 3-2. "Redundant Power Supply (UF-112PS) Installation." 5

2-5. Cooling Fan (1) Fan These cooling fans prevents overheating due to heat generated inside the device. Do not block the fan intake with other equipment, since the air inside the main unit is blown out from the intake located on the right side of the unit. (1) (Front Panel) Indicators The Fan Alarm indicators are placed on the front panel of power units and on the left side of the frame rear panel. The indicator turns off during normal operation. If any indicator lights up red, one or more fans fails. (See the table below) If it lights up red, one or more fans fail. Power off the frame and replace the failed fan, if necessary. indicators Indicator on Power supply unit Indicator on UF-112 rear side Normal condition Turns Off Turns Off Error condition Turns red when a power supply fan error or unit fan error occurs. See section 2-7-2. Alarm Output. If a fan failure occurs in either one of the power units in the the redundant power supply, only the relevant fan indicator turns on. If a fan failure occurs in both units, both fan indicators turn on. Turns red when a power supply fan error or unit fan error occurs. 6

1 5 6 7 8 2-6. Power Unit (4) GENLOCK ON IN 2 3 4 RESET UFM-30CTL FUNCTION TEMP OFF DC Installation example: UFM-30CTLt Module Installation example: UFM Front Module ON GENLOCK IN OFF TEMP DC (1) (2) (3) (1) ON/OFF switch This is the ON/OFF switch for the power. The power turns ON when set to the side. (2) LED indicators The DC power indicator, Genlock indicator and the power alarm indicators are located here. See section 2-7-2. "Alarm Output" for alarm indication. If any power alarm indicator lights up red, turn off the frame power and check the power supply unit. Change the failed power unit, if necessary. Indicator LED GENLOCK Description This LED turns green when the DC power is normally supplied to the modules In the redundant power supply both indicators light up green even when only one of the power units is powered on. This LED turns green when an external reference signal (Black Burst or Tri-Level Sync) is input to the GENLOCK connector LED Normal condition Error condition Turns Off Turns red. (See section 2-5. "Cooling Fan.") TEMP Turns Off Turns red when a temperature error occurs in the power supply module(s). DC_ Turns Off Turns red when a voltage error occurs in the power module(s).. (3) Power unit eject lever To remove the power unit, release and take off an screw on the front and rear panel of the power unit respectively, and then pull out the eject lever. (4) Power unit screw Tighten this screw to firmly secure the power unit. To remove the power unit, remove both screws at the front and rear panels. 7

2-7. Connector 2-7-1. Connector Specifications 15-pin D-sub female Compatible connector: 15-pin D-sub male DA-15PF-N (JAE) Cover: Metal hood Short screw DA-C4-J10-S1 (JAE) *Using inch screws GPI Connector Assignment Table (15-pin D-sub female) No. Signal Signal Details No. Signal Signal Details 1 +24V +24VDC output (*1) 9 +24V +24VDC output 2 GND GND 10 GND GND 3 GND GND 11 2 Power alarm (*2) 4 1 Fan alarm (*2) 12 GND GND 5 COM Common alarm 13 POWALM1- Common contact alarm1- (*3) 6 POWALM1 + 7 POWALM2 + 8 N/C N/C Contact alarm1+ (*3) 14 POWALM2- Common contact alarm2- (*4) Contact alarm2+ (*4) 15 N/C N/C (*1)Max. current per pin at +24 VDC output: 125 ma, Max. current using both pin1 and pin 9: 250mA (*2)Open collector output. Max 24VDC/50mA (*3)A short circuit occurs between the pin 6 contact alarm1+ and pin 13 common contact alarm1- whenever a power voltage (Max 24VDC/0.5A) error, fan stoppage, or a temperature error occurs in the power unit. (*4) A short circuit occurs between the pin 7 contact alarm2+ and pin 14 common contact alarm2- whenever a power voltage (Max 24VDC/0.5A) error, fan stoppage, or a temperature error occurs in the power unit. 8

2-7-2. Alarm Output The connector output and front LED status corresponding to each unit and board status are shown in the tables below. Standard power supply only Power ON/OFF OFF ON Fan operation Power unit temperature Power output voltage - Green Green Green Green Front LED status GENLOCK IN *1 *1 *1 *1 *1 - - Red - - TEMP - - - Red - DC_ - - - - Red 1 Open Open 0V Open Open 2 Open Open Open Open 0V POWALM1+, POWALM1- status Shorted (Electrical connection) : Normal, : Error, -: Off *1 Depends on GENLOCK IN signal status Open (No Electrical connection) Shorted (Electrical connection) Shorted (Electrical connection) Redundant power supply installed (Status of PS2 when PS1 is turned ON) Shorted (Electrical connection) Power ON/OFF OFF ON Fan operation Power unit temperature Power output voltage Not output Green Green Green Front GENLOCK IN *1 *1 *1 Same as LED - Red - standard status TEMP - - Red power supply DC_ Red only 1 Open 0V Open 2 0V 0V 0V POWALM2+, POWALM2- status Shorted (Electrical connection) : Normal, : Error, -: Off *1 Depends on GENLOCK IN signal status Shorted (Electrical connection) Shorted (Electrical connection) 9

Redundant power supply installed (Status of PS1 when PS2 is turned ON) Power ON/OFF OFF ON Fan operation Power unit temperature Power output voltage Front LED status Not output Green Green Green GENLOCK IN *1 *1 *1 - Red - TEMP - - Red DC_ Red 1 Open 0V Open 2 0V 0V 0V POWALM1+, POWALM1- status Shorted (Electrical connection) : Normal, : Error, -: Off *1 Depends on GENLOCK IN signal status Shorted (Electrical connection) Shorted (Electrical connection) Same as standard power supply only Redundant power supply installed (PS1/PS2) Power ON/OFF OFF ON Fan operation Power unit temperature Power output voltage - Green Green Green Green Front LED status GENLOCK IN *1 *1 *1 *1 *1 - - Red - - TEMP - - - Red - DC_ - - - - Red 1 Open Open 0V Open Open 2 Open Open Open Open 0V POWALM1+/2+, POWALM1-/2- status Shorted (Electrical connection) Open (No Electrical connection) Shorted (Electrical connection) *2 Shorted (Electrical connection) *3 Shorted (Electrical connection) *3 : Normal, : Error, -: Off *1 Depends on GENLOCK IN signal status *2 When a fan motor fails, the pins are shorted not in both power supply units but only in the failed power supply unit. *3 The pins are shorted only in the failed power supply unit. 10

2-7-3. Connection Circuit Example Example of 1/2 (Open-Collector Output) Circuit Output +24V DC Power (Use internal +12VDC power supply or, if external power is used, it must not exceed +24DCV.) 1 2 R (Determine the resistance value, so that the current value of the output pin will not exceed 50mA.) 50mA max COM UF-112 side Example of POWALM1,2 (Alarm Out Contact Relay) Circuit POWALM1+ (2+) Close when error occurs or the power turns OFF. Relay contact POWALM1- (2-) UF-112 side Rated voltage Rated current 24VDC 0.5A 11

3. Installation Caution Be careful that the UFM moduls are not damaged by static electricity. Be sure to use a body ground for preventing electrostatic damage by making the UF-112 casing and your body at the same electric potential. After installing UFM modules or a power module, the front panel must be installed before operating the UF-112 in your system. To install the front panel, grasp the two knob screw on the front panel face, and tighten and attach the screws. 3-1. UFM Module Installation UFM modules can be installed in any empty slots. If there are empty slots, it is better to install the modules with space between them rather than bunched together to prevent internal overheating and simplify the signal connection work from the rear panel. IMPORTANT A UFM module set consists of a front and rear module. Be sure to always install the front and rear modules in the same slot positions. The front UFM module can be installed with the power on. The power must always be turned off, however, when installing the rear UFM module. Be sure to always install blank panels in the empty slots. This helps to prevent the intrusion of foreign objects and internal overheating. For the UFM-30CTL installation, see the UFM-30CTL operation manual. 12

3-1-1. Rear UFM Module Installation (1) Turn OFF the power of the UF-112. (2) Removing the blank panel A blank panel is installed in the slot where the rear UFM module will be installed in the UF-112 rear panel. Remove the two set screws on both sides of the blank panel, and then take out the blank panel. Keep the removed blank panel in a safe place. Remove the blank panel (3) Inserting the rear UFM module Board guide rails are provided for each slot. Put the board into the guide rail, and then insert slowly and carefully. Guide rail Guide rail Guide rail Guide rail (4) Securing the module Use the two screws removed in step (1) to secure the board firmly in place on the right and left. 13

3-1-2. Front UFM Module Installation (1) Removing module holder The slot module holder is provided in the UF-112 front panel. Loosen the top screw and bottom screw securing the holder, and then take it off. (2) Inserting the front UFM module Board guide rails are provided for each slot. Put the board into the guide rail, and then insert slowly and carefully. Guide rail Guide rail 14

(3) Securing the modules Attach the slot module holder that was removed in step (1). Tighten the top screw and bottom screw to firmly secure the holder in place. 15

3-2. Power Supply Installation The UF-112PS (redundant power supply) is installed to the UF-112 frame as shown in the procedure below. Use the same procedure for replacing a power unit. Cation To prevent an electrical shock, be sure to either connect the ground terminal to a ground wire or unplug the AC power cable from the AC outlet before performing any work. In case of an emergency, the redundant power supply can be installed with the power on. However, normally the UF-112. power should be turned OFF during installation. After installing UFM modules or a power module, the front panel must be installed before operating the UF-112 in your system. To install the front panel, grasp the two knob screw on the front panel face, and tighten and attach the screws. 3-2-1. Power Unit Installation (1) Installing the power unit Insert the power unit slowly and carefully into each slot. ON GENLOCK IN ON GENLOCK IN TEMP TEMP OFF DC OFF DC 16

(2) Securing the power unit Tighten the screw at the front panel of the power unit to firmly secure the unit. Tighten screw (bind, M3 x 6) Tighten screw (bind, M3 x 6) Redundant Power Supply (UF-112PS) ON GENLOCK IN ON GENLOCK IN TEMP TEMP OFF DC OFF DC (3) Tighten the screw at the rear panel of the power unit to firmly secure the unit. Tighten screw (bind, M3 x 6) Tighten screw (bind, M3 x 6) AC100-240V ~ 50/60 Hz IN AC100-240V ~ 50/60 Hz IN RATING LABEL IMPORTANT Connect the power cable, and then turn on the power switch on the power unit front panel. Turn ON the power switches for both the standard power supply and redundant power supply units. The system will not automatically switch to the redundant power supply when a power supply error occurs unless both power supplies are turned ON. 17

3-2-2. Removing Power Unit IMPORTANT Turn off the power unit to be replaced and disconnect the power cable before uninstalling the power unit. The system can operate continuously by leaving the other power supply power on. (1) Remove the screw securing the power unit at the rear panel. Remove screw Remove screw AC100-240V ~ 50/60 Hz IN AC100-240V ~ 50/60 Hz IN RATING LABEL (2) Remove the screw securing the power unit at the front panel. Remove screw Remove screw ON GENLOCK IN ON GENLOCK IN TEMP TEMP OFF DC OFF DC 18

(3) Removing the power unit Remove the power unit slowly and carefully from each slot. ON GENLOCK IN ON GENLOCK IN TEMP TEMP OFF DC OFF DC 19

4. Remote Power Monitoring The dipswitch S1 in each power unit inside allows you to remotely monitor the power status via LAN. The remote monitoring is disabled at the factory default setting. To enable the remote monitoring, proceed as follows. NOTE To monitor the power status via LAN, the remote control module UFM-30CTL (separate purchase) is required. Use the browser installed on your PC or an optional UF-NETRU for the status monitoring. 1. Remove the power unit from the UF-112. (See section 3-2-2. "Removing Power Unit.") 2. Remove the cover from the power unit as follows. (1) Remove the bind screw from the front. (2) Remove two bind screws from the top. (3) Remove two flat-head screws from the side. Bind screw Flat-head screw (4) Take off the cover. (4) (3) (3) Front face Side face (1) Top face (2) (2) ON OFF GENLOCK IN TEMP DC 3. Change Pin 8 of the dipswitch S1 from Off to On (remote monitoring). Side face S1 The switch position is indicated by the white square. Do not change other settings. 4. Put back the cover of the power unit. Secure the cover to the unit with the screws removed above. 5. Install the power unit again to the UF-112 frame. (See section 3-2. "Power Supply Installation.") 6. Attach the front panel and secure the panel with two side screws. 20

5. Specifications and Dimensions 5-1. Specifications UF-112 Installable Modules Max. 12 modules + 1 Control card (UFM-30CTL) Genlock In BB: 0.429 Vp-p (NTSC) / 0.45 Vp-p (PAL) or Tri-level sync:0.6 Vp-p 75Ω BNC x 1, loop-through (Terminate with 75Ω terminator, if unused.) Interfaces : 15-pin D-sub (female) (power, fan and, temperature alarm) Temperature 0ºC to 40ºC Humidity 30% to 90% (no condensation) Power 100 VAC to 240 VAC ±10%, 50/60 Hz Consumption 374 VA (366 W) (When 100 VAC, max. draw) Dimensions 430 (W) x 132 (H) x 375 (D) mm Weight 10 kg (w/ one power supply unit) Consumables (if used 24 hours a day at normal temperature) Cooling fan: Replace every 3 years. Power: Replace every 5 years. UF-112PS Power Consumption Maximum output current Dimensions Weight Temperature Humidity 100 VAC to 240 VAC 50/60Hz 374 VA (366W) (If 100 V AC supplied at maximum output current) +24VDC 11.2A 72(W) x 117.5(H) x 363.6(D)mm 2.5kg 0 C to 40 C 30% to 90% (no condensation) 21

GENLOCK IN TEMP DC POW GENLOCK IN TEMP DC POW UNIVERSAL FRAME 5-2. External Dimensions 5-2-1. UF-112 (All dimensions in mm) GENLOCK IN ALM AC100-240V ~ 50 /60Hz IN RATING LABEL t2.6 26.5 24.5 375 2x2-6.4x12 28 76 28 UF-112 6.4 57 37.5 1 2 37.5 132 65 300 430 462 480 65 22

5-2-2. UF-112PS (All dimensions in mm) 23

Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

01/20/2012 Printed in Japan FOR-A COMPANY LIMITED Head Office 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan Overseas Division Phone: +81(0)3-3446-3936, Fax: +81(0)3-3446-1470 Japan Branch Offices Osaka/Okinawa/Fukuoka/Hiroshima/Nagoya/Sendai/Sapporo R&D/Production Sakura Center/Sapporo Center FOR-A America Corporate Office 11155 Knott Ave., Suite G&H, Cypress, CA 90630, USA Phone: +1-714-894-3311 Fax: +1-714-894-5399 FOR-A America East Coast Office 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee, NJ 07024, USA Phone: +1-201-944-1120 Fax : +1-201-944-1132 FOR-A America Distribution & Service Center 2400 N.E. Waldo Road, Gainesville, FL 32609, USA Phone: +1-352-371-1505 Fax: +1-352-378-5320 FOR-A Corporation of Canada 346A Queen Street West, Toronto, Ontario M5V 2A2, Canada Phone: +1-416-977-0343 Fax: +1-416-977-0657 FOR-A Latin America & the Caribbean 5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, USA Phone: +1-305-931-1700 Fax: +1-305-264-7890 FOR-A UK Limited UNIT C71, Barwell Business Park, Leatherhead Road, Chessington Surrey, KT9 2NY, UK Phone: +44(0)20-8391-7979 Fax: +44(0)20-8391-7978 FOR-A Italia S.r.l. Via Volturno 37, 20047 Brugherio MB, Italy Phone: +39-039-881-086/103 Fax: +39-039-878-140 FOR-A Corporation of Korea 1007, 57-5,Yangsan-ro,Yeongdeungpo-gu, Seoul 150-103, Korea Phone: +82(0)2-2637-0761 Fax: +82(0)2-2637-0760 FOR-A China Limited 708B Huateng Bldg., No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Phone: +86(0)10-8721-6023 Fax: +86(0)10-8721-6033 FOR-A Middle East-Africa Office Jebel Ali Free Zone, LOB-16, Office 619, P. O. Box: 261914 Dubai, UAE Phone: +971 4 887 6712 Fax: +971 4 887 6713 *The contents of this manual are subject to change without notice.