Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

Similar documents
User s and operator s manual for art

LED Thunder S-150 Code 1097

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

User s and operator s manual for art Manuale d uso e dell operatore per art. 0302

SquareLED - Aura Bar & Matrix Beam Light 100

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

Spectra Batten (Order code: LEDJ95)

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

DMX LED light effect with 4 lenses

USER MANUAL Table of Contents

aorun manual V2.0 MARCH 2018

BROTHER, BROTHER & SONS

LED-PAR200B USER MANUAL. COLORsplash 200B

Stratos Duo RGB. User Manual. Order code: EQLED371

Waterfall 250 Pro. Elation Professional 4295 Charter Street Los Angeles, Ca Rev. 12/28/05

Fusion 120 Zoom. User Manual. Order code: EQLED068

LED-BANK4 USER MANUAL. COLORbank 4

SOFT LED 4 Vari-White INSTRUCTION MANUAL

USER MANUAL Table of Contents

DESIGN 250 PR PR LIGHTING LTD. No. 571, Yingbin Road, Dashi Panyu, Guangzhou, China

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

American DJ. User Instructions. Model: Mega Bar 50RGB

USER MANUAL Table of Contents

Hex-color RGBAW+UV LED strip light

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

USER MANUAL Table of Contents

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

LED Spere Direct Control 30 ORDERCODE 41125

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

ORDER CODE: EQLED65 USER MANUAL

LED Spot 300W. Please read this user manual before your operation

aorun manual V1.0 OCTOBER 2017

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

MS2540 Current Loop Receiver with RS485 Communication

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

180w led gobo moving USER MANUAL

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

OM2000N INSTALLATION MANUAL

Stage Wash 7x 10W LED Moving Head (RGBW)

PRODUCT SPECIFICATIONS

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

PRODUCT SPECIFICATIONS

VGAD-12 ORDERCODE

American DJ. User Instructions. American DJ

Snapshot. Q-Wash LED USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

Opti Tri White Par. User Instructions

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Image Marketing Projector 1.6

COLORtube EQ Controller

DJ SCAN 150 XT. Table of contents

USER MANUAL MHL-10W-7-RGBW MKII

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Features. High Brightness SMD LED Light source

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

ALO 060 DMX LED scanner

HEX16 Strip User Manual

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Snapshot DMX MEGA STROBE III. User Manual

LED SPOT HEAD USERS GUIDE

American DJ. User Instructions. American DJ Charter Street Los Angeles Ca Introduction

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

L632RG. User's Manual. DMX Address Chart RG 8 GOBO TWINKLING LASER SHOW SYSTEM

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

GR0660. Instruction manual

PILOT 250 PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

PLL1920M LED LCD Monitor

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

VRL PAR-1745 Par Lamp

CHROMAFLOOD 200 DATASHEET

LED IP65 Slimline Par RGBWA +UV 7x12W

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER


PRODUCT SPECIFICATIONS

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

LED Techno Strobe RGB ST-4000RGB USER MANUAL

Code 02E011 - DVP - Electronic Ballast Code 02E010 - DV - Magnetic Ballast

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

PL2410W LCD Monitor USER'S GUIDE.

MANUAL ENGLISH Core Club Ordercode: D2314

PLL2210MW LED Monitor

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

Transcription:

COEF srl. Via Albinatico, 80-82 51019 Ponte Buggianese (PT) ITALY www.coef.it / www.coef.net info@coef.it Graphic by PC CAD & VIDEO Sirio 150 / 150DV Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS Revision 1

INTRODUCTION Thank you for using the Sirio 150 / 150DV! The Sirio 150 / 150DV projects, thanks to an extremely efficient optic system (international patent n. WO99/40361), a powerful light beam which can create numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach incredible levels. The Sirio 150 / 150DV comes in two versions: Cod. 02B010 Cod. 02B011 Sirio 150 for Mastercolour 150W (CDM-T 150W/942 - CDM-SA/T 150W/942). Sirio 150DV with shutter for Mastercolour 150W (CDM-T 150W/942 - CDM-SA/T 150W/942). The Sirio 150 / 150DV can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers. The input protocol is the DMX 512. To drive the Sirio 150 / 150DV we suggest to use our controller MasterShow 512. To make the most of its possibilites and for a correct functioning of this unit in the years to come, we suggest you to read carefully this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections and you will be easily able to use it. ATTENTION: carefully read the directions of this manual. Exclusively follow the safety rules in force and do not carry out assembly and/or maintenance operations without taking all precautions as indicated in the different sections or without the necessary specialization. This manual must always accompany the equipment, therefore it must be available and readable at any moment if necessary. Also in case of sale, rent, change of place and/or ownership, these documents shall be enclosed with the relative equipment. ADVICES FOR A CORRECT INSTALLATION This equipment is destined to an exclusively Professional use. READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.Instruction to prevent injury or damage due to electric shock, fire, mechanical hazards and UV radiation hazards. PROTECTION AGAINTS FIRE 1)This equipment is designed for use with the following lamps only: Mastercolour 150W CDM-T 150W/942 CDM-SA/T 150W/942. Do not use any other type of lamp! 2) Maintain minimum distance of 0.3 meter from walls or any other type flammable surfaces. 3) Maintain minimum distance of 1.0 meter to lighted objects. 4) Replace fuses only with the specified type and rating. 5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm. PROTECTION AGAINST ELECTRIC SHOCK 1) This equipment must be earthed. 2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord. 3) For connection to the mains supply proceed as pict.3 page 6. 4) Disconnect power before installing the lamp or servicing (service personnel). PROTECTION AGAINST MECHANICAL HAZARDS 1) Use secondary safety chain when fixing this equipment. 2) Hot lamp explosion hazard. Do not open the equipment for 300 seconds after switching off. 3) Equipment surface may reach temperature up to 90 C. Allow about five minutes before handling. 4) Replace the lamp if it is damaged or thermally deformed and however after 6000 life hours. PROTECTION AGAINST UV RADIATION HAZARDS 1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged. 2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced, for example, by cracks or deep scratches. 3) Do not look directly at the lamp while lamp is on.t Declaration of CE conformity COEF srl. Via Albinatico, 80-82 / 51019 Ponte Buggianese (Pistoia) ITALY Declare that the product Sirio 150 / 150DV is in conformity with 89/336 EEC-EMC directive and with the actual required safety standars in accordance with LVD 73/23 EEC Pag. 2 http://www.coef.it - info@coef.it

DANGER SIGNAL: Generic dager signal and electric shock danger signal. GENERAL WARRANTY CONDITIONS The guarantee is valid for a period of 12 months from the date of purchase of the equipment. The guarantee is not valid in case a wrong voltage or frequency is selected. The parts which are proved to have manufacturing defects are also covered by the guarantee. The external parts of the equipment, its removable elements and lamps are excluded from the guarantee; for these parts we recommend to follow the directions supplied by their manufacturers. The guarantee is not valid in case of tampering or repairs carried out by non-authorized personnel. The replacement of the equipment during the validity of the guarantee is not provided for. The transport freights from and to the manufacturer for repairs under guarantee are at Customer s charge. When applying for the repair, always mention the serial number and the model of the equipment. PACKING CONTENTS Carefully check the contents of the packaging and the completeness of the components. If any of the parts listed hereunder is missing, please contact your Dealer immediately: Sirio 150 / 150DV complet unit This user manual Lamp (upon request) Wall fixing plate PROTECT NATURE. DO NOT DISPOSE OF THE PACKAGING IN THE ENVIRONMENT. CAREFULLY KEEP THE BOX AND THE COMPONENTS OF THE PACKAGING FOR ANY DISPLACEMENT OR RE-SHIPMENT OF THE EQUIPMENT. Do not leave the packaging elements (polystyrene, nylon, metal parts, etc.) unattended. TECHNICAL NOTES LAMP Mastercolour CDM-T 150W/942 or CDM-SA/T 150W/942) Averange lamp life: 6000 hours Colour temperature: 4200 K Luminous flux: 14000 lumen Colour rendering index: 96 Ra OPTIC/COLOUR SYSTEM New concept optical system (patent pending) Full CYM color mixing, unlimited variety of colours and shades High resolution stepper motors Colour crossfades can be programmed at four different speeds or in real time DIMMER (for code 02B011 only) 0-100% continuosly variable (256 steps) CONTROL INPUT Interface standard: RS-485; opto-coupled input Protocol: USITT DMX 512 Stand-alone control: auto mode function master/slave (synchro mode) POWER SUPPLY Rated voltage: 230 Vac on request: 208 Vac 60 Hz; 200 Vac 50 Hz Rated frequency: 50 or 60 Hz Rated current: 1.1A Rated power: 250 Va FUSES Lamp fuse: 3.15A/250V T (time-delay) Electronics fuse: 1.6A/250V T (time delay) http://www.coef.net - info@coef.it Pag. 3

DMX IN - DMX OUT fig.1 POWER INPUT The equipment must be earthed. If this rule is not followed, the warranty will be void. IP 66 grade: to ensure the declared IP grade choose the correct size of the cables (from 3 to 6.5mm). All the gaskets and the glass must be keeped in full working order. BEFORE USING Read all cautions and warnings to page 1 prior to install this equipment. Particularly, read the following: Before connecting the equipment to the power system: 1) Make sure that the mains voltage and frequency correspond to rated values shown on the label (pict.1). 2) Connect the mains power cable to the electronic boards inside and if necessary (synchro-mode) the DMX cable. The Sirio 150 / 150DV is made for a mains voltage 230V 50 Hz; 1,1A For a power supply of 100V-120V it is necessary to use one auto transformer with the following features: Output voltage 230V. Output current 2A. Before any operation on the fixture a) Disconnect power before lamp s replacement (page 5) or servicing (service personnel). b) Do not open the lamp cover for 300 seconds after switching off. c) Wear gloves and goggles to re-lamping (page 5) or to work inside the unit (service personnel). Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm. The unit must be positioned at least 30 cm. from walls or other flammable surfaces and minimum 1.0 meter to lighted objects. External surfaces temperature: After 5 minutes work; Tc=75 C. Once the thermic balance has been obtained; Tc=90 C.t Pag. 4 http://www.coef.it - info@coef.it

INSTALLATION OF THE LAMP d) Replace the lamp when the lamp life is exhausted (6000 hours) to avoid bad peformances of the fixture or that the optic system is damaged by the lamp explosion. e) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness has been reduced, for example, by cracks or deep scratches. f) The lamp must be replaced if it has been damaged or thermally deformed. g) In case of installation of the spot to a truss, check carefully that the fixture is fixed with a chain to both truss and unit. In case of replacement of the lamp or maintenance, do not open the fixture unless 5 minutes have passed from the switching off. DICHROIC BLADE (C) PARABOLE (D) LAMP (E) SCREW (B) SCREW (A) SHUTTER BLADE (F) fig.2 1) Disconnect power before installing the lamp. Wear gloves and goggles. 2) Unscrews the four screws on the glass cover and fully open the eight dichroic and shutter blades (C and F ). 3) Unscrews the screws A and B and remove the reflector parabole (D). 4) Insert the lamp (E) into the lampholder socket. Do not touch the quarz bulb with fingers. If this happenes, clean the bulb before use with dry cloth and alcohol. Polish with a dry cloth. 5) Screws the glass cover. http://www.coef.net - info@coef.it Pag. 5

CONNECTION TO THE MAINS POWER AND TO THE DMX SIGNAL / REPLACING FUSES To connect the Sirio 150 / 150DV to the mains power, remove the cover located behind the fixture, and connect the cable to the electronic board as shown in pict. 3. The connection to the DMX signal to the Sirio 150 / 150DV must be made by using standard DMX cables as shown in pict. 3/a HIGH VOLTAGE! Always disconnect the mains supply before opening the connections area. To ensure the IP66 rate choose the correct size of the cables (from 3 to 6.5 mm.) In order to avoid any problem in the signal transmission, it is warmly suggested to use a cable for high speed data transmission. The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long. If the lines have a total length over 150-200 mts it is suggested to use any DMX Repeater Amplifier MAINS VOLTAGE CABLE 230Vac/ Fig. 3 Fig. 3/a DMX CABLE DMX TERMINAL LINE The wrong connection of the terminal line or its non-connection are probably the most frequent reasons for the defective functioning of the. The is a terminal resistor fitted at the end of the cable furthest from the transmitter. The terminal resistor should have the same value as the impedance of the connection cable. We suggest to use a terminal with a 100 ohm resistor. It is recommanded that all DMX 512 systems have the terminal resistor fitted in the DMX output of the last fixture. Pag. 6 http://www.coef.it - info@coef.it

SIRIO 150 / 150DV SETUP DMX 512 CONTROL 1) Connect the DMX data cable coming from the controller to the DMX-IN connector on the electronic board (see pict. 3/a). 2) Connect the DMX data cable to the DMX-OUT connector on the electronic board to control the next Sirio 150 / 150DV (see pict. 3/a). 3) Select the DMX starting address by operating on the rotary switches (UNITS, TENS, HUNDREDS). EXAMPLE 1: 1 DMX 512 OUTPUT Connection controller-spot with 1 DMX512 Output Consolle DMX Consolle DMX EXAMPLE 2: 2 or more DMX 512 Output Connection controller-sopt with 2 or more DMX512 Output EXAMPLE 3: Connection controller-spot to 1 DMX512 Output over 150mts long Consolle DMX LINE> 150mt. (With microphonics or audio cable) DMX Signal Amplifer EXAMPLE 4: Connection controller-spot to 1 DMX512 Output over 150mts long Consolle DMX LINE> 150mt. (With microphonics or audio cable) DMX Signal Amplifer DMX 512 CHANNELS ASSIGNEMENT IN THE SIRIO150 / 150DV The rotating switches to assign the channels DMX 512 are located on the printed circuit of the electronics which is inside the connections area. There are three rotating switches, and each one is numbered from 0 to 9: one for the UNITS, one for the TENS, one for the HUNDREDS. In the picture below it is shown the position of the three switches when using four Sirio 150 / 150DV in DMX 512. Spot N.1 Spot N.2 Spot N.3 Spot N.4 Channels 1-6 Channels 7-12 Channels 13-18 Channels 19-24 http://www.coef.net - info@coef.it Pag. 7

AUTO - MODE CONTROL 1) Set n 6 on the HUNDREDS rotary switch (MASTER). 2) Choose the games by operating on the UNITS and TENS rotary switches. Available games: from n 1 to n 15 (see appendix B ). Game n 11 is the one which enables all the colors. SYNCHRO - MODE CONTROL (pict. below) 1) Interconnect all the Sirio 150 / 150DV (max 32) by using the DMX standard cables. 2) Set the first Sirio 150 / 150DV as MASTER by setting n 6 on the HUNDREDS rotary switch. 3) Choose the games by operating on the UNITS and TENS rotary switches (on MASTER fixture). Games: from n 1ton 15 4) Set all the rest of the Sirio 150 / 150DV as SLAVE by setting n 7 on the HUNDREDS rotary switch. EXAMPLE OF CONNECTION AND SETTING OF 4 SIRIO 150/150DV IN SYNCHRO-MODE Spot 1 as MASTER Sample game 12 Spot 2 as SLAVE Spot 3 as SLAVE Spot 4 as SLAVE DMX LISTING Pag. 8 http://www.coef.it - info@coef.it

APPENDICE B Complet list of available games http://www.coef.net - info@coef.it Pag. 9