Hybrid recorder mega-log tn

Similar documents
Process transmitter RMA422

Process Transmitter RMA 422

Multifunction devices

Capacitance Level Measurement Electronic insert FEC 12

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Operating instructions Electronic preset counter Type series 717

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Pen and Multichannel Recorder: Digital Display

Level Measurement silometer FMC 420, FMC 423

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Panel-mounting thermostats, type series EM

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

multi-function meters

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

DPR100 C/D Pen and Multichannel Recorder: Digital Display

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

SCALE & WEIGHT DISPLAYS

PRINCIPLES AND APPLICATIONS

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Micro-DCI 53ML5100 Manual Loader

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Hybrid Chart Recorder 250 mm (10")

Standard RS232 RS ma

Capacitance Limit Detection nivotester FTC 420/421/422

DCP100 Digital Control Programmer Specifications

DMP 331i / DMP 333i LMP 331 i

RMA42. Technical Information

Bimetal Temperature Switch

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Rack mounted telephone- and leased line modem for industrial applications

Preset counters, electronic

Standard signal metering in wall-mounting case

Single Axis Position Controller

Series CT7N Bimetallic Overload Relays

Technical Information RIA45

Agilent 5345A Universal Counter, 500 MHz

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

02/11/2015

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

MTL Software. Overview

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Flexible Counter Series in DIN size 24 x 48 mm

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Programmable Power Supplies 188 W 384 W R&S HMP Series

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

GFT channel Time Interval Meter

IMPAC Infrared Thermometers

MICROPROCESSOR CALCULATION MODULE - S2000

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Generator protection relay

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

EVENT INPUT/OUTPUT MODULE [PUME]

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Intelligent Security and Fire Ltd

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Meteor Product Catalogue

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Transcription:

Technical information TI 039R/09 / e / 08.94 Part No.: 500 70 089 Hybrid recorder mega-log tn Universal line strip chart recorder with patented colour dot overwrite technology, 2, 3, or 6 analogue input for reliable multi channel recording. Application areas For multi channel recording without compromising response time. Where value is placed on: secure recording for long term monitoring and quality control combination record of a number of process related parameters precise identification of value changes clear limit infringement identification due to colour markings economical replacement for two normal line strip chart recorders Advantages Parallel recording of various fast signals Safe documentation due to patented Overwrite technology Reliable recording when the colour runs out Continuous information in your own language Universal connection of most frequently used analogue and digital signals Modular concept for optimum problem solving System compatible via serial interface Comprehensive text information both in the display and on the chart.

Mega-Log TN Unit features Patented Overwrite technology The combination of the advantages of industrially proven FAX technology with long term colour recording guarantees a safe and secure record. Fast channel identification due to colour. Clear proof of limit infringements due to coloured markings. No information is lost even when the coloured print wheel dries out, the black Safety lines continue the recording. Time and amplitude correct recording due to the continuous thermal record. The high resolution (8 dots/mm) fully maintenance free linear array thermal print head makes sure of the following even without ink: Reliable recording using Safety line. High resolution text printouts. Individual grids and scale printout for each channel. Recording only the most important section of the signal range ( Zoom ) and recording this on a preselectable section of the chart ( Zoning ). Always operational in real time, even on varying paper feed rates, due to date and time printout. The principle is simple: All channels are burnt into the paper simultaneously, without time offset, as a single colour (black) trace. These lines are then traced in colour using a multi colour print wheel. The unit can be set up to trace continuously or only in the case of a limit infringement. Overwrite principle: 1 Spikes Safety line indicates where swift changes occurred 2 Limit values Colour marks the trace when it becomes critical 3No ink Safety line writes when others loose their colour Variable analogue inputs Each channel can be set to its individual input signal. All inputs are galvanically isolated from each other as well as the system, can be calibrated by push buttons and are measured very quickly (10 times per second). Select the correct amplifier board: Standard input board for economic measurement of current (0/4...20mA) and voltage (0...1/10V) Universal input board (option) for selectable measurement of the most frequently used types of analogue signals (+/- mv/v/ma, RTDs, thermocouples and current and voltage measurement as on the standard input board). 2 x 20 digit fluorescent display Display The 2 x 20 digit fluorescent display is integrated in the recorder door. The advantages are: Operation even with a locked door (changes to the set up can only be done by using a security code). Measured values are displayed as digital or analogue values (trend bar graph) Read off values even in direct sunlight.

Roll chart or Z fold paper The Mega-Log T recorder operates with either roll chart or Z fold paper. Roll chart paper for long term recording. Z fold paper for quick convenient viewing even when recording. KCombination cassette for roll and Z fold paper Limit monitoring Five individually presettable limits per channel initiate on request an event printout, activate relays or preset the paper feed rate to your chart requirement. Built-in timer You select the times and weekdays when your recorder needs to be operational. The advantages are: You minimise paper usage. You have a quick overview of process data because unimportant data is not recorded. Mega-Log TN Expanded functions/ Options Automatic signal analysis Your recorder analyses the incoming signal into minimum, maximum and average values per channel over preset time cycles. At the end of the preset time the values are then printed out in a table including measurement point identification, times and engineering units. Loop power supply You can directly power up two wire transmitters (eg. temperature head transmitter) from the recorder. Relays On request relays can be used to transmit limit infringements and faults. The unit is always supplied with one fault / limit relay. Three further limit relays can be fitted (option). The stationary linear array thermal print head records fast spikes Text explains the graphic On demand the mega-log TN will record colour only on limit infringement - thus making limits easily recognisable. The Safetyline continues to record where others loose out on

Mathematic (virtual) channels. Mathematic module Let your recorder calculate! In addition to the normal analogue channels the recorder can have additional channels by mathematically combining the real channels (eg. difference for differential pressure, multiplication for usage calculation for current and voltage). These Mathematic channels can be used in the same way as real inputs (recording, analysis, limit monitoring etc.). Operation using control inputs You can make your recorder operate on external signals. These signals can: change the paper feed rate add explanatory text to the record add the instantaneous values by operating a push button preset the measuring time cycle or suppress recording, eg. when servicing (should only be used in combination with signal analysis). Counting and quantity recording The mega-log t can record quantities by using two impulse counter inputs and/or integrating the analogue input signals. The recorder prints these values out in an easy to read tabular report giving measurement period, daily, monthly and total quantities. Mega-Log TN Accessories, Operation Accessories Spade to screw terminal plug on adaptors. In strips for all signal inputs, control inputs and power supply. Configuration, readout and setting up software Readex T on disk (IBM compatible computers, is always delivered with the serial interface option) Roll chart paper (unprinted, 120 mm wide, approx. 20 m long) Z fold paper (unprinted, 120 mm wide, 12 m long) Setting up / operation Matching the recorder to the measurement application and reading out values can be done at the recorder or remotely (using a PC). Local input and read-out. Local operation is done using the film keypad on the front of the recorder All setting up steps are divided into functional groups. This means that all general parameters (such as feed rate, date and time) or channel specific values are allocated in individual setting up chapters. Benefits: Swift access to single setting up positions for changes or corrections. Structured and user led system for initial setting up. Expansion options are easy to add. Changing values is possible by following a simple schematic using five operation keys. The display assists you in every step of the way using explanatory text. If the unit is not being set up the actual values can be: called up singly displayed as a numeric value or in the form of a trend bar graph displayed in a scroll sequence for single or all channels. On request even minima, maxima, average values and counter values can be displayed. Display: Trend bar graph rising

Mega-Log TN Exapanded functions / Interfaces Dynamic process control DPC Using this interface the recorder can learn and store the sequence of a repeating process (batches). Variations from a stored reference process in subsequent processes y Block time Limit monitoring are dynamically monitored for infringement of preset tolerance bands. If infringement occurs the effect is the same as limit infingement (text printout, feed rate change, activate relay). A1 A2 -tz +tz t y(tn) Dynamic process control DPC Proces start: Activate control input (terminal 83) Time window tz for memorized values (here for value y(tn)) Process end: Deactivate contol input (terminal 83) Serial interface / PC programme Readex T The alternatively selectable interfaces (RS 232, RS 422/485) can be connected to process systems. The Readex T PC programme enables: Remote setting up and storing of various unit parameters Text printout on the recorder Central readout of instantaneous values/daily minima, maxima, average values/counter values all dependent on the unit configuration. Memory / readout of signal analyses The signal analysis, compiled min, max and average (or counter value) information can be stored in the unit (RAM 128 KByte or 512 KByte). These can be transmitted to a PC, displayed there and stored on the hard disk drive (eg. for further analysis using spread sheets). This is also included in the Readex T software. Readex T: operation level / measured value table Fig. left: Readex T: Graphic display of signal analysis Fig. right: Readex T: Display of counter values

Mega-Log TN Installation/dimensions Dimensions: Front and side elevation, panel cutout Laboratory housing dimensions Wall cabinet dimensions Desk top housing dimensions

Mega-Log TN Terminal layout Mega-Log TN rear panel with 4 pole screw terminal adaptor on the auxiliary voltage connections Mega-Log TN terminal layout Analogue inputs: Control inputs: 111 +Channel 1 Sense Loop + 81 Time mark 1 112 Channel 1 Pt 100 A Loop 82 Time mark 2 113 Channel 1 Pt 100 B - - -83 External measuring period 211 +Channel 2 Sense Loop + 84 Recording suppressed 212 Channel 2 Pt 100 A Loop 85 Count input A 213 Channel 2 Pt 100 B - - -86 Count input B 311 +Channel 3 Sense Loop + 87 Time synchronisation 312 Channel 3 Pt 100 A Loop 88 External feed rate change 313 Channel 3 Pt 100 B - - -89 Instantaneous value printout 411 +Channel 4 Sense Loop + 90 Text 2 0 412 Channel 4 Pt 100 A Loop 91 Text 2 1 413 Channel 4 Pt 100 B - - -92 Text 2 2 511 +Channel 5 Sense Loop + 93 Text 2 3 512 Channel 5 Pt 100 A Loop 94 Text printout command input 513 Channel 5 Pt 100 B - - -95 + Remote synch. power supply 611 +Channel 6 Sense Loop + 96 Remote synch. output 612 Channel 6 Pt 100 A Loop 97 Not used 613 Channel 6 Pt 100 B - - - 98 Not used + + Auxiliary power source +24 V - Auxiliary power source (Common for control inputs) Relays: Serial interface: 41 Normally closed (nc) Relay 1 Sub D connector to DIN 41 652 42 Common (c) Relay 1 9 pole socket 43 Normally open (no) Relay 1 a) RS 485 b) RS 422 c) RS 232 1 Screen Screen Screen 44 Normally closed (nc) Relay 2 2 TXD 45 Common (c) Relay 2 3 RXD/TXD( ) RXD( ) RXD 46 Normally open (no) Relay 2 4 TXD( ) 5 GND GND GND 51 Normally closed (nc) Relay 3 6 52 Common (c) Relay 3 7 GND 53 Normally open (no) Relay 3 8 RXD/TXD(+) RXD(+) 9 TXD(+) 54 Normally closed (nc) Relay 4 55 Common (c) Relay 4 56 Normally open (no) Relay 4

Mega-Log TN Technical data Measurement unit Measurement frequency/resolution Measurement ranges: Standard input board Measurement range: Multi function board (Option) 100 ms (all channels) resolution 15 Bit Voltage: 0... 1/10 V (over range: max. 50 V) Current: 0/4... 20 ma via shunt (over range: max.100 ma) Cable open circuit monitor: 2 ma (range 4... 20 ma) Input impedance > = 1 MOhm on voltage / 50 Ohm on current (on rear panel board) Accuracy: Base accuracy: < = 0.1 % of FSD Long term drift: < = 0.2 % of FSD. Power up drift up to 4 h: < = 0.1 % of FSD. Temperature drift: < = 0.2 % / 10 K 0/4.. 20 ma via 50 Ωshunt Ni 100-60.. +180 C Pt 500-100.. +600 C Pt 100-100.. +600 C Pt 1000-100.. +600 C Type L -200.. +900 C Type K -200.. +1372 C Type U -200.. +600 C Type J -210.. +1200 C Type B 200.. +1820 C Type T -270.. +400 C Type S 0.. +1800 C Type N -270.. +1300 C Type R -50.. +1800 C Compensation: internal, ext. 0 C, ext. 20 C, ext. 50 C, ext. 60 C, ext. 70 C, ext. 80 C 0.. 1 V ±1 V 0... 10 V ±0,2 V ±10 V ±0,1 V ±5 V ±50 mv ±2 ±20 mv Base accuracy: 0,20 % of FSD Power up drift up to 4h: 0,10 % of FSD Temperature drift: 0,20 % of FSD/10 K Cable open circuit monitor: on thermocouples from approx. 50 kohm Damping Time constant presettable: 0.. 999,9 s, System base damping can be ignored Influencing effects Climatic To DIN 40040, 43782/Part 2 Operation temperature: 0.. +50 C Storage temperature:- 20.. +70 C Recording paper: to DIN 16234 EMC/immunity To NAMUR recomendations NE 21: No functional interference due to: Elect. fast transients (bursts): Level 4, IEC 801-4 VDE 0843/4 Electrostatic discharge: Level 4, IEC 801-2 VDE 0843/2 Electromagnetic fields: Level 3, IEC 801-3 VDE 0843/3 (Exception RTDs or ranges < 1V: Level 2, max. allowable deviation on RTD 1,5 % of, range, at ± 20 mv 0,6 % of range) Normal mode noise > 40 db at input range/10 (50 Hz / 60 Hz ±0.5 Hz) rejection Common mode < = 0.1 % measurement span at 160 V (50 Hz/60 Hz noise rejection ±0,5 Hz), (Standard input board) Power failure No function loss due to mains power loss for up to 20 ms Potential difference Channel to channel 160 V RFI To EN 55011: Class A

Recording unit / display Recording unit Linear array thermal head, static, resolution 8 dots/mm for "Safety line" recording (monochrome signal trace). Colour overwrite using changeable 2, 3 or 6 channel colour print wheel (colour capacity: > 300,000 dots / chamber) Colour sequence: 2 and 3 channel versions: Channel 1 : blue, Channel 2 : red, Channel 3 : green 6 channel version: Channel 1 : violet, Channel 2 : red, Channel 3 : black, Channel 4 : green, Channel 5 : blue, Channel 6 : brown Paper feed rate Feed rate types: Standard (optional: external) all presettable to: 0-5-10-20-60-120-240-300-600-1200- 1800-3600-7200 mm/h Channel Numbering individual curves, printout next to the signal line identification Paper type Selectable roll (approx. 20 m) or Z fold paper (approx. 12 m) Chart divisions Presettable in rough (5... 15 divisions) and fine (2,5, 10) grids per channel Recording range per (Part) signal range: 000.1... 100 % in engineering units channel Channel offset: 1 mm... 100 mm preselectable Display Door integrated 2 x 20 digit fluorescent display for digital and/or trend bar graph display of measured values Operation language: german, english, french, italian, spanish, danish, dutch (please indicate which language is required on the order) Power supply Supply ranges AC: 230 V - 115 V - 24 V (50/60 Hz each +10/-15%) DC: 24 V ±20 % Electrical safety To VDE 0411/IEC 348 Primary fuse 315 ma slow blow (230 V power supply) 630 ma slow blow (115 V power supply) 3.15 A slow blow (24 V AC/DC power supply) Housing / connections Housing Sheet steel for panel mounting 144 x 144 mm Colour RAL 7016 Housing door Selectable with latch or lock,integrated display Protection class IP 44 to DIN 40050 Installation depth 320 mm Connections Spade terminals (DIN 46244), 6.3 x 0.8 mm or 2.8 x 0.8 mm

Options 30 event texts max. digits per text: 15 Print command via limit infringement or external signals Integration Additional integration of the analogue signal Presettable per channel Presettable integration time base (second, minute, hour and day) 4 counters per analogue input for Presettable measuring period (10 digit) Day (10 digit) Month (12 digit) Totaliser (12 digit) Periodic printout ( statistic ) Analysis of analogue input into: minimum, maximum and average values over selectable time cycles. Mathematic module 3 additional channels, these mathematically combine the values on the real analogue inputs (summation Housing models Desk top housing Loop power Up to 5 power supplies can be supplied (alternative to an analogue channel) Per channel: 24 V DC ± 10 %, 24 ma, short circuit protected 2 count inputs max. 25 Hz (function: see control inputs) Control inputs To DIN 19240: Feed rate change, time marks, measurement external start/stop, instantaneous value printout, 15 text printouts externally controlled, time synchronisation (in connection with control input remote synchronisation ) Function: Logical 0 equals -3 V... + 5 V Logical 1 equals +12 V... +30 V a) External voltage source with positive voltage impulses up to 24 V Input resistance: apprx. 10 kohm Bounce time: max 5 ms b) Potential free contacts Control outputs 1 control output for remote synchronisation of a number of recorders On hour change: Fleeting contact for 700 ms Auxiliary voltage Aux. voltage from recorder Serial interface RS 232 C, RS 422/RS 485 (including PC operation software Readex T ) Technical alterations reserved

MEGA-LOG TN How to order Colour line strip chart recorder Mega-Log TN Power supply: H 230 V AC, 50/60 Hz F 15 V AC, 50/60 Hz D 24 V DC/AC Model: 1 144 mm x 144 mm panel mounted, roll chart paper 2 Desk top model, rubber feet, mains cover, roll chart paper 3 144 mm x 144 mm panel mounted, Z fold chart paper 4 Desk top model, rubber feet, mains cover, Z fold chart paper 7 Laboratory housing (with HW options) A Wall mounting cabinet IP 65 Operating language/programme: A German (I with 30 event texts) B English (K with 30 event texts) C French (L with 30 event texts) D Italian (M with 30 event texts) E Spanish (N with 30 event texts) F Dutch (P with 30 event texts) G Danish (R with 30 event texts) Front door/paper illumination: A Door with latch B Door with lock E Door with latch and paper illumination F Door with lock and paper illumination Signal preparation and evaluation: A Without signal preparation and evaluation B MM = Mathematic module C INT = Integration D SA = Periodic statistic printout of minimum/maximum/average values I DPC = Dynamic process control Q MM + INT + SA + DPC Count inputs and control inputs 1 0 Without count /control inputs 1 CI = 2 count inputs 2 TMC = 2 time marks 3 REM = External signal analysis release / measurement suppression 7 CI + TMC + REM Control input 2 0 without control input 1 EF = External feed rate change 2 MOM = Instantaneous value printout 3 ETP = 15 externally released text printouts 7 EF + MOM + ETP Further in/outputs A Without further in/outputs B RS 232 = RS 232 serial interface C RS 4 = RS 485/422 serial interface D SYNC = Remote synchronisation E REL = Relay N RS 232 + 128 KByte memory T RS 232 + REL + SYNC + 128 KByte memory Number of analogue inputs 2 Two analogue inputs 3 Three analogue inputs 6 Six analogue inputs (In/outputs): Channel 1 1 Standard input (0... 1/10 V, 0/4... 20 ma) 6 Universal input (U, I, TC, RTD) (In/outputs): Channel 2 0 Channel 2 not required 1 Standard input (0... 1/10 V, 0/4... 20 ma) 6 Universal input (U, I, TC, RTD) (In/outputs): Ch. 3 (same as Ch. 2) (In/outputs): Ch. 4 (same as Ch. 2) (In/outputs): Ch. 5 (same as Ch. 2) (In/outputs): Ch. 6 (same as Ch. 2) TN- Complete order code Other configurations on request

For other applications: Hybrid recorder mega-log t Maintenance free single colour line strip chart recorder, 1 to 6 analogue inputs for continuous and discontinuous measured value recording Hybrid recorder mega-log tp Economic colour dotting recorder with patented Dot-to-Dot joining technology, 6 analogue inputs for recording slow changing signals Hybrid recorder mega-log tl Fast colour line strip chart recorder using permanent overwrite technology. 1 to 3 analogue inputs, for continuous process recording Data-Manager memo-log Multi functional system component for recording, memorising, monitoring, compressing and displaying analogue process data Export division E+H II Endress+Hauser Instruments international Postfach 2222 97574 Weil am Rhein West Germany Tel. (07621) 975-02 TI 039R/09 / e / 08.94 Printed in Germany (500 70 089)