Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Similar documents
Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Technical Manual. Model 7266 Master and Model 7266 Slave

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

Industriefunkuhren. Technical Manual. LED Display 3550 (25mm / 6 Digit / 7-Seg.) ENGLISH. Version:

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Gamma instabus. Technical product information

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Absolute Encoders Multiturn

DLP200M 2 Relay Module for Heating and Cooling Plants

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Spectra Batten (Order code: LEDJ95)

Aegis Electronic Group

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

ODW-621. RS-232 Point-to-point applications

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Technical Description

Fusion 120 Zoom. User Manual. Order code: EQLED068

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

INDEP. QUARTZ MIN. - 1/2 MIN. AFNOR / IRIG B DHF / RADIO

MICROMASTER Encoder Module

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

02/11/2015

Technical data. General specifications. Indicators/operating means

OM2000N INSTALLATION MANUAL

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

DCP100 Digital Control Programmer Specifications

One channel video link With duplex data and contact closure

Fibre Optic Modem ODW-611

SAT IF distribution system

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Stratos Duo RGB. User Manual. Order code: EQLED371

SG4424 HDTV Slave Sync Generator User Guide

Rack mounted telephone- and leased line modem for industrial applications

DLP600M 6+1 Relay Module for Heating and Cooling Plants

multi-function meters

Analogue output module DAO 081

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

I N S T R U C T I O N D A T A

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

EGM Einthoven Goldberger Module Type 701

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

3G/HD/SD-SDI to HDMI Converter

Model :UVC-S100 (Universal Video Converter)

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

GMB101R BLACK BURST & PATTERN GENERATOR GMB101R-M 09/06/08

Process transmitter RMA422

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

USER S MANUAL. FX2N-8AD Analog input block

DMP 331i / DMP 333i LMP 331 i

Operating instructions

PRINCIPLES AND APPLICATIONS

INSTALLATION & USER GUIDE

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Style 5S Clock / Timer

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Telemetry Receiver Installation Guide

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Model Number Structure

VariTime TM Digital Sync Generator, PT 5210

Transcription:

Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013

2 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

INPORTANT NOTES Version number (Firmware / Manual) THE FIRST TWO DIGITS OF THE VERSION NUMBER OF THE TECHNICAL MANUAL AND THE FIRST TWO DIGITS OF THE FIRMWARE VERSION MUST COMPLY WITH EACH OTHER. THEY INDICATE THE FUNCTIONAL CORRELATION BETWEEN DEVICE AND TECHNICAL MANUAL. THE DIGITS AFTER THE POINT IN THE VERSION NUMBER INDICATE CORRECTIONS IN THE FIRMWARE / MANUAL THAT ARE OF NO SIGNIFICANCE FOR THE FUNCTION. Downloading Technical Manuals All current manuals of our products are available free of charge via our homepage on the Internet. Homepage: E-mail: http://www.hopf.com info@hopf.com Symbols and Characters Operational Reliability Disregard may cause damages to persons or material. Functionality Disregard may impact function of system/device. Information Notes and Information. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 3 / 20

SERVICE RELIABILITY Safety regulations The safety regulations and observance of the technical data serve to ensure trouble-free operation of the device and protection of persons and material. It is therefore of utmost importance to observe and compliance with these regulations. If these are not complied with, then no claims may be made under the terms of the warranty. No liability will be assumed for any ensuing damage. Safety of the device This device has been manufactured in accordance with the latest technological standards and approved safety regulations The device should only be put into operation by trained and qualified staff. Care must be taken that all cable connections are laid and fixed in position correctly. The device should only be operated with the voltage supply indicated on the identification label. The device should only be operated by qualified staff or employees who have received specific instruction. If a device must be opened for repair, this should only be carried out by employees with appropriate qualifications or by. Before a device is opened or a fuse is changed all power supplies must be disconnected. If there are reasons to believe that the operational safety can no longer be guaranteed the device must be taken out of service and labelled accordingly. The safety may be impaired when the device does not operate properly or if it is obviously damaged. CE-Conformity This device fulfils the requirements of the EU directive 2004/108/EC "Electromagnetic Compatibility" and 2006/95/EC "Low Voltage Equipment". Therefore the device bears the CE identification marking (CE = Communautés Européennes = European communities) The CE indicates to the controlling bodies that the product complies with the requirements of the EU directive - especially with regard to protection of health and safety for the operator and the user - and may be released for sale within the common markets. 4 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

TABLE OF CONTENTS Contents Page 1 General... 7 2 Connecting Elements of Module 7628... 8 3 Commissioning... 9 4 Configuration of Module 7628... 9 4.1 Access the Module 7628... 10 4.2 Parameterization of Module 7628... 11 4.2.1 Overview of DIP Switches / Jumper... 11 4.2.1.1 DIP Switch DS1... 12 4.2.1.2 DIP Switch DS2... 13 4.2.1.3 Jumper J3/J4... 13 4.2.2 Parameterization of the Synchronization Source... 14 4.2.3 Parameterization of the Signal Outputs... 14 4.2.3.1 Selection of the Output Format IRIG-B / IEEE C37.118 / AFNOR... 14 4.2.3.2 Signal Output in Relation to the Synchronization Signal... 14 4.2.3.3 Parameterization of the Value for the SyncOFF Timer... 15 4.2.3.4 Time Basis for Output IRIG-B / IEEE C37.118 / AFNOR... 15 4.2.4 Parameterization of the Output Amplitude (only applicable for analogue signals)... 16 4.2.5 Parameterization of the Status LED (Green)... 16 5 IRIG-B / IEEE C37.118 / AFNOR NF S87-500... 17 5.1 IRIG-B nach IRIG Standard 200-98... 17 5.2 IRIG-B nach IRIG Standard 200-04... 18 5.3 IEEE C37.118-2005 (formerly IEEE 1344-1995)... 18 5.4 AFNOR NF S87-500... 18 6 Technical Data... 19 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 5 / 20

TABLE OF CONTENTS 6 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

GENERAL 1 General The Module 7628 is a compact IRIG-B generator for the integration into Clock Systems and signal converters. This module converts an internal fed time information into an IRIG-B signal (analogue or digital). The module can put out different IRIG-B Time Code Formats: IRIG-B according to IRIG Standard 200-98 (format does not include any year date) IRIG-B according to IRIG Standard 200-04 IEEE C37.118-2005 formerly IEEE 1344-1995) AFNOR NF S87-500 The output of signals is carried out via two completely potential isolated outputs. Here analogue or digital IRIG-B signals, depending on the module version, can be generated. Its function is guaranteed by just supplying the Module 7628 with power and providing appropriate time information. Both are usually carried out in the basis system the Module 7628 is integrated in. However the module can also be used in an independent signal converter. The Module 7628 requires approx. 2-3 minutes for a successful time synchronization, depending on the fed synchronization signal. As the module has no internal back-up clock and in order to receive an internal time for the time generation, it is required to synchronize the module after a reset or a power failure again. The according status of the module is shown by three LEDs in the front panel enabling to identify a successful or rather a disturbed synchronisation and the activities of the two signal outputs visually. The signal output of Module 7628 depends on the appropriate synchronization status and also on internal settings. The signal output is directly configured on the module via DIP switch and jumper. Functional Principle: 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 7 / 20

CONNECTING ELEMENTS OF MODULE 7628 2 Connecting Elements of Module 7628 Connection The signal output is processed via BNC connector female or a 3-pole pluggable screw terminal depending on the module version. Status Display The connecting elements have a LED (yellow) each showing the current signal outputs. The Status LED (green) indicates the synchronization status of the Module 7628 and is also used for diagnosis of the input signal at the internal synchronization input of the module in case of a problem. ANALOGUE signal outputs are marked with A1 and A2 (possibly A3 and A4) Module 7628 in DIN Rail Housing Module 7628 in 3U/4HP Panel (19" Systems) BNC Connector female Core - Signal Output POSITIVE Shield - Signal Output NEGATIVE Clamp 1 (+) - Signal Output POSITIVE 2 (n.c.) - not connected 3 (-) - Signal Output NEGATIVE DIGITAL signal outputs are marked with D1 and D2 (possibly D3 and D4) Module 7628 in DIN Rail Housing Module 7628 in 3U/4HP Panel (19" Systems) BNC Connector female Core - Signal logic - HIGH active Shield - GND (Ground) Clamp 1 (H) - Signal logic - HIGH active 2 ( ) - GND (Ground) 3 (L) - Signal logic - LOW active 8 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

COMMISSIONING Example: A1/A2 BNC Connector female LED Meaning Status LED (green) Synchronisation status LED on on/off 900/100 msec on/off 100/900 msec on/off approx. 2 Hz FLASHING off Function Signal output synchronized Signal output realized with active SyncOFF Timer Signal output on basis of internal time information of the module (without external synchronization) Module is in testing mode for signal output Module has no valid time information Board damaged / no voltage A1 A2 BNC A1 A2 LED (yellow) Indication of signal output at BNC connector female A1 LED (yellow) Indication of signal output at BNC connector female A2 Function Signal output of IRIG-B / IEEE C37.118 / AFNOR Signal output of IRIG-B / IEEE C37.118 / AFNOR 3 Commissioning After the parameterization of the module (via DIP switch and jumper) has been completed commissioning is carried out by switching-on the basis system or rather the converter. 4 Configuration of Module 7628 The used synchronization signal and the signal output at the connecting elements need to be configured according to the appropriate application. Attention: Never work on the open unit when voltage is applied! Danger to life! ESD The system contains ESD-sensitive components, briefly when touching these elements ESD safety measures needs to be observed. Using the module in hopf basis systems the relevant settings are usually carried out at the factory. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 9 / 20

CONFIGURATION OF MODULE 7628 4.1 Access the Module 7628 For the configuration of the component it needs to be pulled out of the appropriate hopf basis system / converter and the following steps are to be accomplished: 1. Switch-off and disconnect the device 2. Loosen the fixing screws of the appropriate front panel 3. Pull the panel with Module 7628 carefully out of the housing. Ensure that no internal connecting cables are turned off or get damaged. 4. Configure the component via DIP switch and jumper. 5. Afterwards insert the component carefully into the housing by considering the connecting cable. 6. Fix the front panel with the screws. 10 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

CONFIGURATION OF MODULE 7628 4.2 Parameterization of Module 7628 There are two DIP switches and two jumpers on Module 7628 for parameterization. The DIP Switch DS1 and the jumper J3/J4 are on the component side and (TOP) and the DIP Switch DS2 on the conductor side (BOTTOM). The jumpers are only available on module versions for analogue signal outputs. Component Side Conductor Side 4.2.1 Overview of DIP Switches / Jumper The DIP Switch should only be adjusted with an appropriate tool in order to avoid damage to the switch. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 11 / 20

CONFIGURATION OF MODULE 7628 4.2.1.1 DIP Switch DS1 SW8 off on Step Size for SyncOFF Timer 10 minutes 1 hour SW7 SW6 Factor for SyncOFF Timer off off 2x SW8 (Step Size) SyncOFF Timer (20min / 2h) off on 4x SW8 (Step Size) SyncOFF Timer (40min / 4h) on off 6x SW8 (Step Size) SyncOFF Timer (60min / 6h) on on 8x SW8 (Step Size) SyncOFF Timer (80min / 8h) SW5 off Service Mode Reserved for. The setting should not be changed and must always be off! SW4 SW3 SW2 SW1 Selection of Sync Source off off off off 01: hopf Binary string with PPS (NTP configuration) off off off on 02: hopf System-BUS 6000 with PPS off off on off 03: hopf System-BUS 7001 with PPS off off on on 04: hopf Master/Slave-String Transmission cycle: every minute off on off off 05: hopf Master/Slave-String Transmission cycle: every second off on off on 06: hopf Master/Slave-String with PPS Transmission cycle: every min. off on on off 07: hopf Master/Slave-String with PPS Transmission cycle: every sec. off on on on 08: DCF77 Pulse (1Hz) Local time (MEZ) on off off off currently not connected (currently hopf Binary string with PPS) on off off on currently not connected (currently hopf Binary string with PPS) on off on off currently not connected (currently hopf Binary string with PPS) on off on on currently not connected (currently hopf Binary string with PPS) on on off off currently not connected (currently hopf Binary string with PPS) on on off on currently not connected (currently hopf Binary string with PPS) on on on off currently not connected (currently hopf Binary string with PPS) on on on on currently not connected (currently hopf Binary string with PPS) DIP Switch SW5 of DS1 must always be off (service mode). For the signal generation the selection of the sync source 08: DCF77 pulse (1Hz) local time (MEZ) means a fixed defined difference time (Time Zone Offset) of +1h from local time to UTC for the time zone MEZ. The other sync source settings use the difference time transferred with the sync source signal. 12 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

CONFIGURATION OF MODULE 7628 4.2.1.2 DIP Switch DS2 SW8 off on Identification of Input Signal via Status LED (Green) Status LED (green) for synchronization display Diagnosis Mode Indication of the received synchronization signal at the internal input of Module 7268 SW7 SW6 Signal Output IRIG-B / IEEE C37.118 / AFNOR off off Always when time in the module is valid off on When the module is currently synchronized or the SyncOFF Timer is active on off Only when the module is currently synchronized on on Test Mode Test signal output SW5 SW4 SW3 Selection of Output Format IRIG-B / IEEE C37.118 / AFNOR off off off IRIG-B / B007+B127 (time, year, second of day) off off on IRIG-B / B003+B123 (time, second of day) off on off IRIG-B / B006+B126 (time, year) off on on IRIG-B / B002+B122 (time) on off off IEEE C37.118 (formerly IEEE 1344) on off on AFNOR NF S87-500 on on off Not connected (currently IEEE C37.118) on on on Not connected (currently IEEE C37.118) SW2 SW1 Selection of the Time Zone for the Output off off Local time off on UTC time on off Standard time (local time without ST/WT changeover) on on Not connected (currently local time) 4.2.1.3 Jumper J3/J4 The output amplitude BNC connector female A1/A2 is set via jumper J3/J4 (chapter 4.2.4 Parameterization of the Output Amplitude (only applicable for analogue signals)). These jumpers are not available at outputs for digital outputs. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 13 / 20

CONFIGURATION OF MODULE 7628 4.2.2 Parameterization of the Synchronization Source Adjustment via: DS1 / SW1-SW4 Default: No Default-Setting The Module 7628 can be synchronized by different time information. Using these modules in hopf basis systems the necessary settings are performed by default (ex Works). Using the module in converter units the settings may be required by the customer. This selection determines what kind of time information should be evaluated by the module. Currently hopf specific time formats as well as the DCF77 pulse (1Hz) with local time (MEZ) are available for the synchronization. 01: hopf Binary string with PPS (NTP configuration) 02: hopf System-BUS 6000 with PPS 03: hopf System-BUS 7001 with PPS 04: hopf Master/Slave-String Transmission cycle: Every minute 05: hopf Master/Slave-String Transmission cycle: Every second 06: hopf Master/Slave-String with PPS Transmission cycle: Every min. 07: hopf Master/Slave-String with PPS Transmission cycle: Every sec. 08: DCF77 Pulse (1Hz) Local time (MEZ) There is no synchronization of the Module and also no generation of the signal for the output in case of an incorrect setting. 4.2.3 Parameterization of the Signal Outputs The output of the IRIG-B signal can be parameterized for different applications. 4.2.3.1 Selection of the Output Format IRIG-B / IEEE C37.118 / AFNOR Adjustment via: DS2 / SW3-SW5 Default: OFF/OFF/OFF This setting determines which of the available time (IRIG-B / IEEE C37.118 / AFNOR NF S87-500) should be put out at the connecting elements. 4.2.3.2 Signal Output in Relation to the Synchronization Signal Adjustment via: DS2 / SW6-SW7 Default: OFF/OFF The behaviour of the signal output in relation to the internal condition of synchronization can be set. If the module is in a synchronization state without having outputs, the outputs are inactive (no output of a carrier signal). 14 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

CONFIGURATION OF MODULE 7628 Different output criteria can be set: Signal output always when time is correct By means of this synchronization signal a module internal clock is synchronized that independently runs until the next reset in case of a synchronization failure. This time basis is used for the signal generation if the synchronization signal is lost. When the module is currently synchronized or the SyncOFF Timer is active In this mode a signal output is only provided when the module is really synchronized by the internal synchronization signal and as long as the SyncOFF Timer is not expired (after synchronization failure). The SyncOFF Timer is automatically activated when the external synchronization of the module fails. The SyncOFF Timer is reset automatically after re-synchronization. Only when the module is currently synchronized With this adjustment only a signal output is provided while the module is really synchronized via the internal synchronization signal. Output of test signal For test purposes the output of an "IRIG-B signal" is possible with this setting even without synchronization of the module. For the test signal a fixed-programmed time information is used. After start of the module with an activated test signal a time loop of one hour is put out. The time loop starts with the fixed-programmed time value: 14:30h 27th April 2007 The output format of the test signal complies with the one selected via the DIP switch for the "normal" output. 4.2.3.3 Parameterization of the Value for the SyncOFF Timer Adjustment via: DS1 / SW6-SW8 Default: OFF/OFF/OFF Based on the adjustment of the appropriate output mode the time for the output of signals after loss of the internal synchronization signal (e.g. in case of failure) can be determined via the SyncOFF Timer. Switch SW8 of DS1 is used for setting the increment of the time value. Switches SW6 to SW7 of DS1 are used for setting the factor for the increment. These three switches allow the adjustment of the SyncOFF Timer from 20-80 minutes or rather from 2-8 hours. 4.2.3.4 Time Basis for Output IRIG-B / IEEE C37.118 / AFNOR Adjustment via: DS2 / SW1-SW2 Default: OFF/OFF The synchronization sources supported by the module provide all necessary information in their protocols enabling the module to process the signal generation with the different time bases. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 15 / 20

CONFIGURATION OF MODULE 7628 4.2.4 Parameterization of the Output Amplitude (only applicable for analogue signals) Adjustment via: J3 and J4 Default: 2-3 The output amplitude for the connecting elements A1/A2 is set via the jumpers J3/J4. The load-dependent amplitude ranges are defined in Chapter 6 Technical Data. Jumper J3 for Output at Connecting Element A1 1-2 Small amplitude 2-3 Large amplitude Jumper J4 for Output at Connecting Element A2 1-2 Small amplitude 2-3 Large amplitude 4.2.5 Parameterization of the Status LED (Green) Adjustment via: DS2 / SW8 Default: OFF For the diagnosis of the internal synchronization signal the status LED (green) can be adjusted to indicate the internal input signal of the module 1:1. 16 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

IRIG-B / IEEE C37.118 / AFNOR NF S87-500 5 IRIG-B / IEEE C37.118 / AFNOR NF S87-500 The following telegrams / Time Code formats can be put out by Module 7628: IRIG-B according to IRIG Standard 200-98 IRIG-B according to IRIG Standard 200-04 IEEE C37.118-2005 (formerly IEEE 1344-1995) AFNOR NF S87-500 5.1 IRIG-B nach IRIG Standard 200-98 The IRIG-B format consists of a time code of 74 bits and a repeat rate of one second. The bit frame is 10msec. The quality rating of a bit is marked by the pulse width modulation and is a multiple of a millisecond. For synchronisation on the beginning of the second a neutral logical condition is required named identifier. Logical 0 = 2msec H-level Logical 1 = 5msec H-level Identifier = 8msec H-level The 74 time code bits are divided into 30 bits for the BCD value of the seconds, minutes and hours and the current day of the year 27 bits for the input of control information 17 bits for the binary value of the current seconds of the day Within one second 100 bit frames can be transferred. Not used bit frames are completed with a logical zero. Information referring to the year, difference time UTC to local time and status daylight saving time / winter time are not included in the telegram according to IRIG Standard 200-98. 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 17 / 20

IRIG-B / IEEE C37.118 / AFNOR NF S87-500 The below drawing shows the IRIG-B signal quality rating in analogue and digital format. position identifier reference bit low high 8ms 8ms 2msec 5msec IRIG-B analog IRIG-B digital PPS 5.2 IRIG-B nach IRIG Standard 200-04 The IRIG-B Standard 200-04 is an extension of the Standard 200-98. Additional IRIG telegrams with extended information were defined. For example, the current year is additionally sent in the first control information field. That enables the issue of complete time/date information 5.3 IEEE C37.118-2005 (formerly IEEE 1344-1995) This version of the IRIG Standard is an extension of the IRIG Standard 200-98. The 27 bits of the control information field are occupied with fixed data as year, time offset between UTC and local time, daylight saving time / winter time status etc. It is downward compatible to the IRIG Standard 200-98 (the IRIG Standard 200-98 is included as a subset). 5.4 AFNOR NF S87-500 This IRIG standard is issued by the French Institute of Engineering Standard and is built up on the Standard IRIG 200-98. 27 bits of the control information field are occupied with fixed data as year, month etc. It is downward compatible to IRIG Standard 200-98 (the IRIG Standard 200-98 is included as a subset). 18 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01

TECHNICAL DATA 6 Technical Data The company hopf withhold the right to hard- and software alterations at any time. General General Data Operation Installation Position Protection Type of Board Dimensions of Module via DIP switch and jumper any position IP00 multi-layer board 80mm x 40mm Power Supply 5V DC ± 5% (via internal plug-in connection ) Power Consumption MTBF Weight approx. 500mA when both outputs are under load with 50Ohm approx. 830mA when short-circuits at both outputs > 950,000 hours approx. 0.05kg Temperature Range Operation Storage Humidity 0 C to +50 C -20 C to +75 C max. 90%, non condensing CE compliant to EMC Directive 89/336/EC and Low Voltage Directive 73/23/EC Safety / Low Voltage Directive DIN EN 60950-1:2001 + A11 + Corrigendum EN 61000-6-4 EMC (Electromagnetic Compatibility) / Interference Immunity EN 610000-4-2 /-3/-4/-5/-6/-11 EN 61000-6-2 EN 61000-3-2 /-3 Radio Interference Voltage EN 55022 Radio Interference Emission EN 55022 EN 55022 Class B EN 55022 Class B Analogue Signal Outputs Potential Isolation Insulation Voltage: at least 500V DC 1000M Output Voltage A1/A2 Jumper J3/J4 600 Ω Load Resistance 50 Ω Load Resistance Position 1-2 approx. 3.9 Vpp approx. 2.8 Vpp Position 2-3 approx. 7.5 Vpp approx. 5.6 Vpp IRIG-B Modulation Depth 3 : 1 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01 19 / 20

TECHNICAL DATA Digital Signal Outputs Potential Isolation Insulation Voltage: at least 500V DC 1000M Output Voltage D1/D2 Output HIGH Current: max. 40 ma Voltage: 5V +/-10% Output LOW Current: max. -40 ma Voltage: 0.0-0.6V Supported Output Formats IRIG-B / Bxx7 (time, year, second of the day) according to IRIG Standard 200-04 IRIG-B / Bxx3 (time, second of the day) according to IRIG Standard 200-04 IRIG-B / Bxx6 (time, year) according to IRIG Standard 200-04 IRIG-B / Bxx2 (time) according to IRIG Standard 200-04 IEEE C37.118-2005 (formerly IEEE 1344) AFNOR NF S87-500 Accuracy Synchronisation via serial String + PPS or rather via DCF77 Pulse Accuracy of generation (Offset to external PPS/DCF77 pulse): + 7 to 8µs Jitter (Offset to external PPS/DCF77 pulse): +/-40ns Synchronisation via serial String Accuracy of implementation (Offset to serial time mark): + 180 to 220µs Jitter (Offset to serial time mark): +/-50µs 20 / 20 7628 IRIG-B Generator-Module for analogue / digital Signals - V02.01