Agilent 5345A Universal Counter, 500 MHz

Similar documents
Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

Microwave Counter, Power Meter and DVM in One Portable Package


Advanced Test Equipment Rentals ATEC (2832)

Full-featured CW Microwave Counters for Field, Factory or Lab

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

PM 6680B / PM 6681 / PM 6681R

Agilent 8560 E-Series Spectrum Analyzers

Agilent Technologies 54522A

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

Advanced Test Equipment Rentals ATEC (2832)

Data Pattern Generator

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Fluke PM6690. Frequency Counter/Timer/Analyzer

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

R&S FSMR Measuring Receiver Specifications

R-1550A Tempest Wide Range Receiver

R3267/3273 Spectrum Analyzers

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Datasheet SHF A

Digital Storage Oscilloscopes 2550 Series

!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

2 MHz Lock-In Amplifier

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Agilent PSA Series Spectrum Analyzers Data Sheet

PicoScope 6407 Digitizer

Microwave/Counter/Analyzer & Integrated Power Meter

8650A SERIES UNIVERSAL POWER METERS

Signal Stability Analyser

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Synthesized Clock Generator

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

R&S SMF100A Microwave Signal Generator Specifications

Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview

GFT Channel Digital Delay Generator

Section one: General description

R&S ZNBT Vector Network Analyzer Specifications

R&S ZVA110 Vector Network Analyzer Specifications

GFT Channel Slave Generator

Assembly Level Service Guide

E4416A EPM-P Series Single Channel Power Meter

PicoScope 6407 Digitizer

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Microwave/Counter/Analyzer with Integrated Power Meter MCA3000 Series Datasheet

R&S FPC1000 Spectrum Analyzer Specifications

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Keysight Technologies ad Integrated RF Test Solution

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Agilent 4-Port PNA-L Microwave Network Analyzer

ScopeMeter 190 Series Specifications

SDS1000C Specifications

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

THE ART OF ENGINEERING

L-Band Block Upconverter

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

Synthesized Block Up- and Downconverter Indoor / Outdoor

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R-1580A Microwave Downconverter. Product Brochure

R&S ZND Vector Network Analyzer Specifications

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

MICROWAVE MEASURING INSTRUMENTS

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Digital Delay/Pulse Generator

ATS MS/s 8-Bit PCI Digitizer

GFT channel Time Interval Meter

R&S SMB100A RF and Microwave Signal Generator Specifications

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Digital Delay/Pulse Generator

MULTIBAND 1/3 RACK-MOUNTED

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

PAM-1840 Preamplifier Operation Manual

Digital Delay/Pulse Generator

R&S EDS300 DME/Pulse Analyzer Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Agilent 8153A Lightwave Multimeter Technical Specifications

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

4 MHz Lock-In Amplifier

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

SYNTHESIZED COMMUNICATION CONVERTERS

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

Features. PFD Output Voltage 2000 mv, Pk - Pk. PFD Gain Gain = Vpp / 2π Rad khz 100 MHz Square Wave Ref.

SatLabs Recommendation for a Common Inter-Facility Link for DVB-RCS terminals

N5264A. New. PNA-X Measurement Receiver. Jim Puri Applications Specialist March Rev. Jan Page 1

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

User s Manual of Signal Level Meter TABLE OF CONTENTS

NI PXI/PXIe-2543 Specifications

R&S SMBV-Z1 Reference Frequency Converter Specifications

Transcription:

Agilent 5345A Universal Counter, 500 MHz Data Sheet Product Specifications Input Specifications (pulse and CW mode) 5356C Frequency Range 1.5-40 GHz Sensitivity (0-50 deg. C): 0.4-1.5 GHz -- 1.5-12.4 GHz -25 dbm 12.4-18 GHz -20 dbm 18-26.5 GHz -20 dbm 26.5-34 GHz -15 dbm 34-40 GHz -10 dbm 0.4-1.5 GHz -- 1.5-12.4 GHz +5 dbm 12.4-18 GHz +15 dbm 18-26.5 GHz +15 dbm 26.5-40 GHz +15 dbm 36-110 GHz -- Damage Level: +25 dbm peak Impedance: 50 ohm NOMINAL SWR: (typical) 0.4-1.5 GHz -- 1.5-10 GHz <2:1 10-18 GHz <3:1 18-26.5 GHz <3:1 26.5-34 GHz <3:1 34-40 GHz <5:1 36-110 GHz -- Connector: APC 3.5 male with collar HP 5345A/55A Frequency Range: 0.4-1.5 GHz

Sensitivity (0-50 deg. C): 0.4-1.5 GHz -15 dbm 1.5-12.4 GHz -- 12.4-18 GHz -- 18-26.5 GHz -- 26.5-34 GHz -- 34-40 GHz -- Damage Level: +24 dbm peak (use in BNC Connector) Impedance: 50 ohm NOMINAL SWR: (typical) 0.4-1.5 GHz <2:5:1 Connector: BNC CW Mode HP 5356C FM Tolerance: Auto Mode: 60 MHz p-p, rate: dc - 10 MHz Man Mode: 80 MHz p-p, rate: dc - 10 MHz AM Tolerance: Any modulation index provided the minimum signal level is greater than the counter sensitivity. Acquisition Time (typical): Auto Mode: 1.4s (Option 001: 1.1s) Man Mode: 15 ms GATE TIME <= 100 ms: Acquisition time + 4 x HP 5345A GATE TIME + HP 5345A Sample Rate + 125 ms GATE TIME > 100 ms: Acquisition Time + HP 5345A GATE TIME + HP 5345A Sample Rate + 35 ms LSD: 1 divided by 5345A GATE TIME Resolution: +/-2 x LSD +/- 10e-10 RMS x FREQ Accuracy (after 1 min. warmup): Resolution +/- Timebase error x FREQ FM Tolerance: Auto Mode: 60 MHz p-p, rate dc - 10 MHz Man Mode: 80 MHz p-p, rate: dc - 10 MHz AM Tolerance: Any modulation index provided the minimum signal level is greater than the counter sensitivity. Acquisition Time (typical): Auto Mode: 1.4s (Option 001: 1.1s) Man Mode: 15 ms GATE TIME <= 100 ms: Acquisition time + 4 x HP 5345A GATE TIME + HP 5345A Sample Rate + 125 ms

GATE TIME > 100 ms: Acquisition Time + HP 5345A GATE TIME + HP 5345A Sample Rate + 35 ms LSD: 1 divided by 5345A GATE TIME Resolution: +/-2 x LSD +/- 10e-10 RMS x FREQ Accuracy (after 1 min. warmup): Resolution +/- Timebase error x FREQ 5345A/55A FM Tolerance: Instantaneous frequency must not exceed 0.,4-1.5 GHz range AM Tolerance: Any modulation index provided the minimum singal level is greater than the counter sensitivity. Acquisition Time (typical): FREQ >= 800 MHz: <1 ms FREQ <800 MHz: HP 5345A Sample rate + 35 ms Acquisition time + HP 5345A GATE TIME + HP 5345A Sample Rate + 35 ms LSD: 1 divided by 5345A GATE TIME Resolution: +/-5 x LSD Accuracy (after 1 min. warmup): Resolution +/- Timebase error x FREQ Pulse Mode 5356C FM Tolerance: Input Auto Mode: 50 MHz p-p, Chirp Input Man Mode: 80 MHz p-p, Chirp Input Auto Mode:Input Man Mode: Acquisition Time + Calibration Time + HP 5345A SAMPLE RATE + 60 ms + ((1 us + HP 5345A GATE TIME) / (EXT GATE WIDTH x PRF)) Pulse Width: Input Auto Mode: Min: 100 ns Max: 20 ms Input Man Mode: Min: 75 ns Max: 20 ms Pulse Repetition Frequency: Input Auto Mode: Min: 50 Hz Max: 2 MHz Input Man Mode: Min: 50 Hz Max: 2 MHz Maximum Video Feed-Through: 15 mv p-p typical for RF burst rise and fall times >10 ns. Accuracy (after 1 min. warmup): +/-2 x LSD +/- rms Jitter +/- Gate Error +/- Timebase Uncertainty 5345A/55A FM Tolerance: Instantaneous frequency must not exceed 0.4-1.5 GHZ range

Acquisition Time + Calibration Time + HP 5345A SAMPLE RATE + 60 ms + ((1 us + HP 5345A GATE TIME) / (EXT GATE WIDTH x PRF)) Pulse Width: Min: 150 ns Max: 1 s Pulse Repetition Frequency: Min: 100 Hz Max: 1 MHz Maximum Video Feed-Through: 15 mv p-p typical for rf burst rise and fall times >10 ns. Accuracy (after 1 min. warmup): +/- (16 x LSD) +/- (5 x rms Jitter) +/- Gate Error +/- Timebase Uncertainty 5345A Inputs, Separate Inputs: Range: (dc coupled): 0 to 500 MHz (ac coupled, 50 ohm): 4 MHz to 500 MHz (ac coupled, 1 Mohm): 200 Hz to 500 MHz Impedance: selectable, 1 Mohm (nominal) shunted by approximately 45 pf or 50 ohm (nominal). Sensitivity: X1: 25 mv rms sine wave and 75 mv peak-to-peak X10: 300 mv sine wave and 900 mv peak-to-peak pulse Dynamic Range (50 ohm and 1 Mohm): X1: 25 mv to 300 mv rms sine wave and 75 mv to 900 mv p-p pulse X10: 300 mv to 2.0 V rms sine wave and 900 mv to 6.0V p-p pulse Linear Operating Range: -2.0 to +2.0V dc (nominal) Trigger Level: Adjustable over +/- 2.0V dc Preset: centers trigger level to 0V dc (nominal) at 25 degrees C Drift: +/-10 mv dc max., 0 degrees C to 50 degrees C Output: Channel A and B trigger voltages (x ATTEN) available at rear panel BNC connectors Accuracy: X1: +/-15 mv X10: +/-150 mv (nominal) Slope: independent selection of positive or negative slope 50 ohm, X1: +/-7V dc, 7V rms below 5 MHz, 3.5 Vrms (+24 dbm) 5 MHz and above 1 Mohm, X1: +/-350V dc, 250V rms to 20 khz, decreasing to 3.5V rms above 5 MHz

1 Mohm, X10: +/- 350V dc, 250V rms to 20 khz, decreasing to 35V rms above 5 MHz 5345A Inputs, Common Input Range: dc coupled: 0-400 MHz ac coupled, 50 ohm: 4-400 MHz ac coupled, 1 Mohm: 300 Hz-400 MHz Impedance: 50 ohms remains 50 ohms; 1 Mohm becomes 500 kohm (nominal) shunted by approximately 80 pf. Sensitivity: 50 ohm, X1: 50 mv rms sine wave and 150 mv p-p pulse 50 ohm, X10: 600 mv rms sine wave and 1.8V p-p pulse 1 Mohm: <=50 MHz = 25 mv rms 50-200 MHz = 75 mv rms 200-400 MHz = 120 mv rms Dynamic Range: 50 ohm, X1: 50 mv to 600 mv rms sine wave and 150 mv to 1.8V p-p pulse 50 ohm, X10: 600 mv to 4.0V rms sine wave and 1.8V to 12V p-p pulse 1 Mohm: same as Separate Inputs 50 ohm: +/-5.0V dc or 5V rms 1 Mohm: same as Separate Inputs Trigger Level: adjustable over the range +/-4.0V dc (X ATTEN) in 50 ohm or +/-2.0V dc in 1 Mohm (X ATTEN) Output: Channel A and B trigger voltages times 2 (X ATTEN) available at rear panel BNC connectors Accuracy: 50 ohm, X1: +/-30 mv nominal 50 ohm, X10: +/-300 mv nominal 1 Mohm: same as Separate Inputs Frequency Range: 0.00005 Hz to 500 MHz Resolution: +/- LSD +/- ((Noise Trigger Error) / (Gate Time)) x Frequency Lease significant digit (LSD) is nine digits per second of measurement time. With DISPLAY POSITION switch in AUTO, the LSD error is +/-1 count if the most significant digit (MSD) is 1 through 4, and +/-2 counts if the MSD is 5 through 9. Accuracy: Resolution +/- Timebase Error x Frequency Measurement Time: When in MIN the GATE TIME is 50 ns or one period of the input signal, whichever is greater. When the GATE TIME is set to one of the decade steps, the counter will reset if a stop trigger is not reached within 3.5 times the GATE TIME setting. Decade GATE TIME settings range from 100 ns to 1000s. When using EXT GATE, the measurement cycle time consists of the GATE TIME divided by the duty cycle of the EXT GATE signal plus the time required to reach the next STOP trigger level after the end of the last EXT GATE pulse. General Display: 11-digit LED display and sign. Decimal point is positioned with DISPLAY POSITION control or positioned after the first, second or third most significant digit if DISPLAY POSITION is in AUTO.

Sample rate: rate continuously variable from <0.1s to <5s with front-panel control. In HOLD position the last reading is maintained until the counter is reset or an EXT ARM signal is applied. External arm input: counter can be armed by a -1.0V (-5.0V max) signal applied to the rear panel 50 ohm input for greater than 500 ns. Minimum time between EXT ARM and acceptance of start pulse is <1 us (typical). Operating temperature: 0 degrees C to 50 degrees C. Power requirements: 100/120/220/240V rms +5% -10% 48 to 66 Hz, maximum power 250 VA. Size: 132.6 mm H x 425 mm W x 495 mm D (5.22 in x 16.75 in x 19.95 in); 17kg (37 lb). Output Programmable over the GPIB, the 5345A can transfer more than 9000 measurements per second over the bus. The fast throughput saves time and reduces cost for systems applications. Flexible Gating For applications requiring more detailed information than the average frequency in a burst, the 5345A can accept your choice of measurement gates. External gates as short as 20 ns can be used for profiling the frequency content of a chirp radar, or characterizing the post-tuning drift of voltage-controlled oscillators. Automatic Averaging The automatic averaging algorithm improves accuracy. By lengthening the gate time, you can reduce the effect of jitter and noise on your measurements. High-Stability Timebase The built-in timebase ages at the rate of 5 x 10 e-10 per day, extending the calibration cycle to two years while maintaining khz accuracy for a 20 GHz measurement.