Weschler Analog Switchboard Meters

Similar documents
30 STYLE LISTINGS SWITCHBOARD METERS

WESCHLER INSTRUMENTS. Yokogawa AC Voltage Switchboard Meters

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

ANALOGUE METERS FOR MARINE APPLICATIONS

SCALE & WEIGHT DISPLAYS

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

Measurement and Instrumentation

LAUREL ELECTRONICS, INC.

263 Series LED Bargraph Indicator and Controllers

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Clamp 200 A AC/DC (+ V AC/DC + Ω)

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

BE1-81O/U Frequency Protection. Washington State University Hands-On Relay School.

GP-500 SERIES - Low Voltage

Type Contact form Model

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

Crompton Switchboard Meters

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

TESTING METHODS AND RELIABILITY -POWER

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

SAFETY TERMS AND SYMBOLS

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

ScopeMeter 190 Series Specifications

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Series CT7N Bimetallic Overload Relays

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

HOBO H Energy Logger

ELECTRONIC HARMONICS METER RELAY

Certificate of Calibration

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

MILLITARY SPECIFICATION SHEET

Type MG-6 Auxiliary Relay Class 1E

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Modular Lube Lubrication Systems System Controls

Standard RS232 RS ma

multi-function meters

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Kuhnke Technical Data. Contact Details

Level Measurement silometer FMC 420, FMC 423

EA350. Generator Automatic Voltage Regulator Operation Manual

SAL Series Wireless Clock (V1)

Operating Instructions

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Magnecraft Power Relays

BE3-GPR GENERATOR PROTECTIVE RELAY

EVC300i. Generator Automatic Voltage Regulator Operation Manual

PRINCIPLES AND APPLICATIONS

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Multifunction Digital Timer

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

Henkel Installation Handbook LINEGUARD 2001

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies

Photoelectrics Through-beam Type PA18C.T..., DC

MT32 Telemetry Multi channel telemetry system for rotating application

Automated Local Loop Test System

LARGE DIGITAL TEMPERATURE LED DISPLAYS

Magnetic and Hydraulic-Magnetic Circuit Breaker

ABB IEC International Pin and Sleeve

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

DIRECT DRIVE ROTARY TABLES SRT SERIES

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

TELEDYNE HASTINGS INSTRUMENTS

Model Number Structure

Procurement of IC TESTER & TRAINER KITS, OSCILLOSCOPES, FG S, DECADE BOXES AND ANALOG METERS

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

MICRO SERIES COUNTERS & TIMERS LARGE DIGIT MODEL

Linear flow controls VFC Linear flow controls with actuator IFC

Flat-Bed Module Recorders

Directional Couplers and Splitters

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

DATA SHEET Panorama Rudder Indicator, TRI-2

COHERENCE ONE PREAMPLIFIER

LONWORKS Fibre Optic Converter

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Instruction Manual Model BlockUpconverter

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

TABLE OF CONTENTS. Instructions:

Magnetic Sensor - Incremental EHP

Installation and Operating Instructions. Vari-Watt Power Controller

AF-300 E11 Adjustable Frequency Drive

True RMS AC/DC Mini Clamp Meter

Transcription:

Weschler Analog Switchboard Meters High accuracy, full view design Volts, amps, watts, vars, speed, frequency and power factor High overload capacity Military and Nuclear versions Ultimate in reliability and performance Special scales and calibration Formerly Westinghouse brand TAUT-BAND SUSPENSION Type K-241 & 261 instruments, except those which rotate continuously, use taut-band suspension. The taut-band suspension has unique advantages over the conventional pivot and jewel movement: Type K-241 & 261 instruments are designed to achieve the ultimate in reliability and performance. These instruments are recommended for use on electric utility switchboards and industrial process control panels. Commercial instruments comply with ANSI Standard C39.1 for 1% class switchboard instruments. The Hi-Shock versions were developed to meet the special needs of U.S. Navy shipboard applications. They are also suitable for commercial, marine and industrial applications subjected to humid conditions or severe mechanical shocks. It eliminates friction, giving better accuracy and almost perfect repeatability. It gives top performance under adverse conditions of shock and vibration. It reduces maintenance, thereby saving money throughout the lifetime of the instrument. It assures longer life, reducing annual depreciation and replacement costs. It has greater sensitivity, reducing power burdens on circuits being measured. To facilitate quick, accurate reading, even under adverse conditions, all K-241 instruments feature the Westinghouse full view 250 design. The window is flat, reducing light reflection to minimize the need for a non-glare surface. The dial scale is beveled for a 60 viewing angle. Types Available Function Ranges Type Designation Mechanism DC Microammeter 50µA to 1mA KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Milliameter 1mA to 1A KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Ammeter 1A to 50A KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Millivoltmeter 50mV to 1V KX-241 Com & HI, 241 Com Permanent-magnet moving coil DC Voltmeter 1V to 800V KX-241 Com & HI, 241 Com Permanent-magnet moving coil AC Milliammeter 10mA to 1A KA-241 Com & HI, 261 Com Iron Vane AC Ammeter 1A to 20A KA-241 Com & HI, 261 Com Iron Vane AC Voltmeter 10V to 750V KA-241 Com & HI, 261 Com Iron Vane AC Frequency 50, 60 & 400Hz KX-241 Com & HI With Separate Transducer AC Frequency 50, 60 & 400Hz KR3-241 Com Self Contained Transducer AC Frequency 395-405Hz KR4-241 HI Self Contained Transducer AC Power Factor 0-1-0 KI-241 Com & HI, 261 Com Rotating Vane AC Power Factor 0.5-1-0.5 KJ-241 Com Self Contained Transducer AC Synchroscope -- KI-241 Com & HI, 261 Com Rotating Vane AC Wattmeter 0.1 to 10A KP-241 Com & HI, 261 Com & HI Self Contained Transducer AC Varmeter 0.1 to 10A KP-241 Com & HI, 261 Com&HI With External Phase Shifter AC Varmeter 0.1 to 10A KV-241 Com & HI, 261 Com & HI Self Contained Transducer Rectifier Milliammeter 1mA to 1A KC-241 Com & HI, 261 Com Permanent-magnet moving coil Rectifier Ammeter 1A to 17A KC-241 Com & HI, 261 Com Permanent-magnet moving coil Rectifier Voltmeter 5V to 600V KC-241 Com & HI, 261 Com Permanent-magnet moving coi Resistance Thermometer All Popular Ranges KX-241 Com & HI, 261 Com Self Contained Bridge Speed Indicator 0-25, up to 13000pps KX-241 Com & HI, 261 Com Self Contained Transducer Synchrotie 0-360 KS-241 Com, Unmounted Transmitter Self-Synchronous 43 FULL VIEW DESIGN See more information online at weschler.com/analog KA241 MODIFICATIONS AVAILABLE DIALS: Black Dual Scale Special Colors, Legends Weather resistant Cover ELECTRICAL: Intermediate Ratings Special Calibrations Offset or Suppressed Zero Multiple Rating Special Sensitivity

Catalog page is not available for this product. Return to our website & click the INFO link for information, or call 800-903-9870 WESCHLER INSTRUMENTS Manufacturer & Distributor of Meters, Instruments and related equipment Action Instruments Adalet AEMC Alaron Altek Amprobe API (Absolute Process) Applied Technical Ashcroft ATC (Westcon/Diversified) Bacharach Control Switches Crompton Dixson EIL Electro Industries E-Mon D-Mon Empro ENM Extech Flexcore Fluke Fuji Electric / TTI Hioki Hoyt Instrument Transformer International Instrument Ideal Jewell Kessler Ellis (KEP) Kobold Laurel Electronics MANUFACTURERS LFE London Electronics Madison Martel / Beta Megger / Biddle Meterman MeterMaster Midwest Transformers Modutec Monarch National Meter Newport NK Technologies Non-Linear Systems Noshok Partlow Pyragon Pyromation Raytek Red Lion Selco / Asahi Simpson Texmate Transmation Triplett Vaisala VAS / Doric Veris Weschler Westinghouse Weston (A&M) Yokogawa Meters Analog Digital Bargraph Panel Process Power Switchboard Mil Spec Large Display Meter Relays Sensors Temperature Pressure Flow Strain Position Load Voltage Current Speed Level Humidity Vibration Transducers Current Transformers Potential Transformers Shunts PRODUCTS Signal Conditioners Isolators Transmitters Looop Splitters Alarms Switches Test Equipment Multimeters Clamp-On Meters Thermometers Humidity Meters Light Meters Megohmmeters Hipot Testers Ground Testers Insulation Testers Cable Testers Power Analyzers Process Calibrators Miscellaneous Counters Timers Clocks Controllers Recorders Data Loggers Power Supplies Protection Relays Enclosures & More www.weschler.com 800-903-9870 fax: 800-903-9590 info@weschler.com

Yokogawa AC Watt & VAR Switchboard Meters Accurate to Within ±1% of Full Scale Weathertight Construction Ideal for Adverse Conditions () Easy to Read Up to 30 Feet Away (AB-16) Taut-Band Suspension ±1% of FS basic accuracy class Rectifier Instruments ±1 1 2% @ 25 C calibrated on sine wave Operating Temperature Range 0 40 C (32 F 104 F) 2,300VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils 1.2x continuous; AC ammeters 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Approx. 2.5 seconds (except AB-16) Full Scale 250 (360 for synchroscopes) Deflection Angle Case Size 4 1 4" 8 3 4" Model AB-16 Size (H x W x D) 4.33" x 4.33" x 4.85" 8.69" x 8.69" x 4.85" Barrel (cutout) 4.03" Full Scale Length 6.9" 13.8" VAR METER Rating (Amperes) Rating (Volts) Scale Cat. No. AB-16 Cat. No. Single Phase/2-Wire, 1-Element, Transformer Rated, 60 Hz 5 120 103 31 A 121 31 A 5 120 103 762 A * 121 762A * 3-Phase/3-Wire, 2-Element, Transformer Rated, 50/60 Hz (Cannot Use with External Phase Shifter) 5 120 103 28 A 121 28 A 5 120 103 812A 121 812A 3-Phase, 3-Wire, 2-Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters 5 120 103 32 A 121 32 A 5 120 103 772A * 121 772A * 3-Phase/4-Wire, 2 1 2-Element, Transformer-Rated, 50/60 Hz (Cannot Use External Phase Shifter) 5 208 103 29 B 121 29 B 5 208 103 742B 121 742B 3-Phase/4-Wire, 2 1 2-Element, Transformer-Rated, 60 Hz for Use with External Phase Shifters 5 120 103 34 A 121 34 A 5 120 103 792A * 121 792A * Order by description. Specify CT (Current Transformer) and/or PT (Potential Transformer) ratios if used and scale desired. * Used for 0-Center when calibrating watts are less than ±380. Used for 0-Center when calibrating watts less than ±658. Used for 0-Center when calibrating watts are less than ±760. The 2 1 2-element varmeters used on 4-wire 3-phase 120V L-N systems are rated 208V because they are connected line-to-line. Sixth digit signifies pointer deflection (1-zero left, 2-zero center). Photos not to scale AB-16 AC Wattmeters Non-Isolated (cannot be use with external phase shifter for VARs) Single-Phase/2-Wire, 1-Element, Self-Contained, 50/60 Hz Rating Scale AB-16 Amperes/Volts Cat. No. Cat. No. 1.25 120 0-125 Watts 103 211AARC7GCB 121 211AARC7GCB 2.50 120 0-250 Watts 103 211AAWP7CJB 121 211AAWP7CJB 5 120 0-500 Watts 103 211ARBU7CRB 121 211ARBU7CRB 10 120 0-1000 Watts 103 211AWDP7DAB 121 211AWDP7DAB Single-Phase/2-Wire, 1-Element, Transformer-Rated, 50/60 Hz 5 120 + 103 21 A 121 21 A 3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60 Hz 5 120 103 22 A 121 22 A 5 240 + 103 22 C 121 22 C 5 480* 103 22 D 121 22 D 5 600* 103 22 E 121 22 E 3-Phase/4-Wire, 2 1 2-Element, Transformer-Rated, 50/60 Hz (voltage balanced) 5 69 103 25 F 121 25 F 5 120 + 103 25 A 121 25 A 5 240 103 25 C 121 25 C + Order by Description. Specify CT (Current Transformer) and/or PT (Potential Transformer) Ratios if Used, and Scale Desired. * UL Version in Short Case, Non-UL Version in Long Case. Sixth Digit Signifies Pointer Deflection (1-Zero Left, 2-Zero Center) Custom Scaling Nonstandard Ranges Zero-Center Color Bands WATT METER Nonstandard Frequencies OPTIONS (WHERE APPLICABLE) 48

Yokogawa Mini Switchboard Meters AC/DC Amps, Volts and Frequency To Order Insert Number Code for Each Letter to Select Catalog Number. Order Example: 218200-A42 (0-150) A B A B 2182 Basic Unit 218100 DC Ammeters and Voltmeters 218200 AC Ammeters and Voltmeters 218830 Frequency Meters Rating and Scale DC Ammeter DC Voltmeter AKM 500 madc VNL 30 VDC ALA 1 ADC VNT 50 VDC ALS 5 ADC VPK 100 VDC AMT 10 ADC VPZ 150 VDC AND 15 ADC VRX 300 VDC ANG 20 ADC V01 1 madc ANL 30 ADC 35-10-50 madc A01 50 mvdc 36-4-20 madc A05 100 mvdc 37-1-5 VDC AC Ammeter AC Voltmeter AKG 300 maac VPK 100 VAC AKM 500 maac VPZ 150 VAC ALA 1 AAC V12 150 VAC(for PT) ALC 1.5 AAC VRX 300 VAC ALS 5 AAC VSI 600 VAC A42 5 AAC (for CT) V20 70-130 VAC* AMF 7.5 AAC V21 140-260 VAC* AMT 10 AAC * Expanded Scale ANL 30 AAC Frequency Meter H40 115V 45-55 Hz H60 230V 45-55 Hz H41 115V 55-65 Hz H61 230V 55-65 Hz H42 115V 45-65 Hz H62 230V 45-65 Hz Mini Switchboard Series Compact Size 3" Case Accurate to Within ±1.5% of Full Scale Taut-Band Suspension ±1.5% of FS basic accuracy class Rectifier Instruments ±1.5% @ 25 C calibrated on sine 2,600 VAC for 1 minute between circuit & case Overload Rating Voltmeter or potential coils 1.2x continuous; AC ammeters 2x continuous, 10x for 1 second; Current coils other than AC ammeters 1.5x continuous, 10x for 1 second Approx. 2.5 seconds Full Scale Deflection Angle/Length 250 /5.5 Case ABS resin, black Size (H x W x D) 3.18" x 3.18" x 4.35" Barrel (cutout) 2.84" Dia. Watt, Var & Power Factor To Order Insert Number Code for Each Letter to Select Catalog Number. Order Example: 2185-34-W56 A B C 2185 : Power Factor ±5% of scale length : Watts/VARS ±1.5% of FS value 2,600 VAC for 1 minute between circuit & case NOTE: All units supplied with external transducers. Except balanced Power Factor Meter. A Basic Unit 2185 AC Wattmeters 2186 AC Varmeters 2187 AC Power Factor Meter B Function/Connection Watts 34 Three Phase, Four Wire Vars 33 Three Phase, Three Wire 34 Three Phase, Four Wire Power Factor 33 Three Phase, Three Wire C Input Watts VARs Power Factor W55 120V-1A AC M55 120V-1A AC C55 120V-1A AC W56 120V-5A AC M56 120V-5A AC C56 120V-5A AC W65 240V-1A AC M65 240V-1A AC C65 240V-1A AC W66 240V-5A AC M66 240V-5A AC C66 240V-5A AC OPTIONS (WHERE APPLICABLE) Custom Scaling Nonstandard Ranges Adjustable Potentiometer (Voltmeters Only) Color Bands 44

Yokogawa Power Factor, Frequency & Synchroscope Meters Accurate to Within ±1% of Full Scale Weathertight Construction Ideal for Adverse Conditions () Easy to Read up to 30 Feet Away (AB-16) Taut-Band Suspension Except Synchroscopes AB-16 A NALOG M ETERS Power Factor AB-16 Amperes Volts Scale Cat. No. Cat. No. Single-Phase 2 Wire 60 Hz 5 120.5-1-.5 103 412 FCAD 121412 FCAD 3-Phase 3 & 4 Wire, 50 & 60 Hz, Balanced System Only 5 120.5-1-.5 103 402 FCAD 121 402 FCAD 5 208*.5-1-.5 103 402 CCAD 121 402 CCAD 5 240.5-1-.5 103 402 FEAD 121 402 FEAD 5 480.5-1-.5 103 402 FFAD 121 402 FFAD 5 600.5-1-.5 103 402 FGAD 121 402 FGAD 3-Phase 3 Wire, 50/60 Hz, Unbalanced Systems 5 120.5-1-.5 103 462 FCAD 5 240.5-1-.5 103 462 FEAD 3-Phase 4-Wire, 50/60 Hz, Unbalanced Systems 5 120+.5-1-.5 103 472 FCAD 5 208+.5-1-.5 103 472 CCAD 5 240++.5-1-.5 103 472 FEAD Frequency Meters, 120V Rated Scale Center AB-16 (Hz) Freq, Hz Cat. No. Cat. No. 45-55 50 103 372 AGAG 121 372 AGAG 45-65 55 103 372 AJAJ 121 372 AJAJ 48-52 50 103 372 AKAK 121 372 AKAK 50-70 60 103 372 ALAL 121 372 ALAL 55-65 60 103 372 ANAN 121 372 ANAN 58-62 60 103 372 ATAT 121 372 ATAT 59-61 60 103 372 ASAS 121 372 ASAS 350-450 400 103 372 BHBH 121 372 BHBH 390-410 400 103 372 BLBL 121 372 BLBL Synchroscopes Pivot and Jewel Scale Normal VAC AB-16 Freq. Cat. No. Cat. No. Slow-Fast 50/60 120 106 452 ADAA 120 452 ADAA Slow-Fast 50/60 240 106 452 DDAA 120 452 DDAA Slow-Fast 400 120 106 452 ACAA 120 452 ACAA * Line to line 208V (120V line to neutral) + Line to line ++ Line to neutral ±1% of FS basic accuracy class Rectifier Instruments ±1 1 2% @ 25 C calibrated on sine wave Power Factor Meters ±1% of scale length Balanced system (20-100% rated current) Unbalanced system (±3% of scale length) Frequency Meters 45 Hz 55 Hz, ±0.15 Hz 55 Hz 66 Hz, ±0.15 Hz 58 Hz 62 Hz, ±0.093 Hz 350 Hz 450 Hz, ±1.5 Hz 2,300 VAC for 1 minute between circuit and case Overload Rating Voltmeter or potential coils, 1.2x continuous AC ammeters, 2x continuous, 10x for 1 second. Current coils other than AC ammeters, 1.5x continuous, 10x for 1 second Approx. 2.5 seconds (except AB/DB-16) Full Scale Deflection Angle 250 Case Size Model Size (H x W x D) Barrel (Cutout) Scale Length 4 1 4" AB-14 4.33" x 4.33" x 6.75" 4.03" 6.9" 4 1 4" 4.33" x 4.33" x 6.75" 4.03" 6.9" 8 3 4" AB-16 8.69" x 8.69" x 6.75" 4.03" 13.8" 49