Fluke 430 Series Three-Phase Power Quality Analyzers

Similar documents
Fluke 430 Series Three-Phase Power Quality Analyzers

Fluke 433, 434, 435. Service Manual. Three Phase Power Quality Analyzer

ScopeMeter 190 Series Specifications

Oscilloscopes for field applications

Oscilloscopes for field applications

Selection Table. Ordering Information

User Manual Power and Harmonics Analyzer Model PQ3350

ScopeMeter 190C/190B Series and ScopeMeter 120 Series

Full Disclosure Monitoring

Clamp 200 A AC/DC (+ V AC/DC + Ω)


User Manual. Power and Harmonics Analyzer Model PQ3350

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

ScopeMeter 190 Series and ScopeMeter 120 Series

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

20 years of ScopeMeter Test Tool Innovation Introducing the complete 190 Series II Technical Data. New 500 MHz

PowerMonic. FAQs [2/12]

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

ScopeMeter Test Tools

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Test Equipment Solutions Datasheet

Certificate of Calibration

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

R&S RT-Zxx High-Bandwidth Probes Specifications

Digital Storage Oscilloscopes 2550 Series

R&S RT-Zxx High-Voltage and Current Probes Specifications

ScopeMeter 190 Series

INSTRUCTION MANUAL POWER QUALITY ANALYZER

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

Fluke 279 FC True-rms Thermal Multimeter

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

ProcessMeter. Product Overview

multi-function meters

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Users Manual. Stroboscope. September 2014

JD725A Cable and Antenna Analyzer - Dual Port

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

Display Information Type Backlit blue on white STN Type

Full-featured CW Microwave Counters for Field, Factory or Lab

FEATURES. Measurement and Verification (M&V) Studies Electrical Load Profiling Energy Audits New Technology Assessment Studies

Event recording (or logging) with a Fluke 287/289 Digital Multimeter

02/11/2015

Fluke 434-II/435-II/437-II

R&S RT-Zxx Standard Probes Specifications

Portable Performance for Debug and Validation

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

Fluke 196C/199C. ScopeMeter. Users Manual

OPTICAL POWER METER WITH SMART DETECTOR HEAD

ISO-TECH IPM3005 Flexible AC Power Quality Tester Instruction Manual

R&S ZVA110 Vector Network Analyzer Specifications

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

PQ-Box 100 Quick Start Instructions

LMD-1541W. 15-inch high grade LCD monitor. Overview

R&S RT-Zxx Oscilloscope Adapters Specifications. Data Sheet V23.00

Advanced Test Equipment Rentals ATEC (2832)

R&S EDS300 DME/Pulse Analyzer Specifications

Microwave Counter, Power Meter and DVM in One Portable Package

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

PORTABLE OSCILLOSCOPE

TSG 90 PATHFINDER NTSC Signal Generator

Sources of Error in Time Interval Measurements

LAUREL ELECTRONICS, INC.

Manual PCE-830 power anlayser

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

LED Driver Linear / area fixed output

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

HD-CM HORIZON DIGITAL CABLE METER

Data Pattern Generator

PicoScope 6407 Digitizer

FRQM-2 Frequency Counter & RF Multimeter

80i-500s AC CURRENT PROBE FOR OSCILLOSCOPES

QuickSpecs. HP VH27 27-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit

Advanced Test Equipment Rentals ATEC (2832)

LA1500R USER S GUIDE.

2016 RIGOL TECHNOLOGIES, INC.

: V [p-p] (high impedance) AUDIO IN Stereo mini Jack (M3) x 1 (Shared with DVI-D IN) 0.5 V [rms] D-sub 9-pin x 1 / x 1, RS-232C Compatible

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

i1000s Calibration Manual AC Current Probe for Oscilloscopes

PA9PLUS Portable Power Quality Analyzer

SlimLine. Compliant to DO-160D Document # Rev H. www. rosenaviation.com. www. rosenaviation.com

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Introduction...2. Features...2 Safety Precautions...2. Installation...4

2 MHz Lock-In Amplifier

WVR500 Waveform/Vector Monitor

Fluke 19xB-19xC-2x5C. Service Manual. ScopeMeter. models 192B,196B,199B,192C,196C,199C,215C,225C

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

LED Driver Compact fixed output

LED control gear Compact fixed output

PicoScope 6407 Digitizer

Transcription:

Fluke 430 Series Three-Phase Power Quality Analyzers Pinpoint power problems faster, safer and in greater detail Technical Data The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use handhelds are a must have for any person who maintains or troubleshoots three phase distribution. The new IEC standards for flicker and power quality are built right in to take the guess work out of monitoring. Records all your necessary values in a three phase system. Minimal setup required with intuitive menus. Highest safety rating in the industry. Four voltage and four current channels. Captures waveform data on all phases simultaneously. System-Monitor: Six power quality parameters on one dashboard Automatic Transient display: Never miss an event. Auto Trend: Don t waste time setting up recordings. Rugged, handheld recorder. Seven hours operating time per charge on NiMH battery pack. Transfer data files to your PC for reporting and analysis using FlukeView software. CAT IV 600 V and CAT III 1000 V safety rating Designed to help protect you and your equipment against electrical shock and fire, the Fluke 430 Series analyzers, accessories and charger are all certified to meet the stringent safety standards for use in CAT IV 600 V and CAT III 1000 V environments. They are the first tools of their kind to carry the CAT IV rating and therefore can be used at virtually all power connections and outlets in a low-voltage power distribution system.

Quickly see the trend Auto Trend feature allows fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set thresholds or intervals and without manually starting the process. Quickly view trends for voltage, current, frequency, power, harmonics or flicker on all phases and neutral. Analyze the trends using the cursors and zoom tools even while background recording continues. Measures everything Measure true-rms & peak voltage and current, frequency, dips and swells, transients, interruptions, power and power consumption, peak demand harmonics, inter-harmonics, flicker and unbalance. Simple menu structure with logical function grouping gives fast access to key measurements. AutoTrend automatically records all displayed parameters in the background. Toggle between data and trend view and use cursors and zoom to analyze measurements without interrupting the recording. Track harmonics up to the 50th, and measure and record THD in accordance with IEC61000-4-7 requirements. Automatic transient display Every time an event or distortion on voltage is detected, the instrument triggers and automatically stores voltage and current waveforms on all three phases and neutral. The analyzer will also trigger when a certain current value level is exceeded. Up to 40 dips, swells, interruptions and transients can be captured this way. You can see voltage transients as high as 6 kv and as fast as 5 microseconds. 2 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers

System-Monitor: Multi-parameter power quality health check on one display A single push of the MONITOR button delivers a single dashboard display of rms voltage, harmonics, flicker, interruptions, rapid voltage changes, swells, unbalance and frequency. The dashboard is updated live, showing compliance of each parameter to EN50160 limits or your own limits. Color-coded bars clearly show which parameters are inside (pass) or outside limits (fail). During a Monitor session, you can easily drill down to more detail of any parameter and view and capture its trend for a report. off line on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software. The software s view mode allows cursors and zoom tools to be used on stored measurements. Perform custom analysis and create reports, measurement data can also be exported to common spreadsheet programs. Store up to 10 measurement datasets, each dataset can contain up to 32 parameters and up to 50 screens for use in reports. Perform custom analysis and create reports with FlukeView Power Quality software. Measurement data can also be exported to common spreadsheet programs. The System-Monitor overview screen gives instant insight into whether the voltage, harmonics, flicker, frequency and the number of dips and swells fall outside the set limits. Easy-to-use Thanks to thoughtful features like user-friendly menus in local languages and setups with minimal steps. The high-resolution color screen updates every 200 ms and displays waveforms and wiring diagrams color coded to industry standards. Handy on-screen wiring diagrams for all commonly used three phase and single phase configurations guide you through connections. A detailed list is given of all events falling outside the set limits. By scrolling through the event list and selecting an event, the event can be analyzed in detail. Extensive data analysis possibilities The Fluke 430 Series provides three ways to analyze measurements. Cursors and zoom tools can be used live while taking measurements or The full color display uses region specific industry-standard colorcoding (user selectable) to correlate measurements with actual wiring. Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 3

Specifications Input characteristics Voltage inputs Number of inputs 4 (3 phases + neutral) Maximum input voltage 1000 Vrms Maximum peak voltage 6 kv Input impedance 4 MΩ / 5 pf Bandwidth 9 khz, up to 100 khz for transient display Scaling 1:1, 10:1, 100:1, 1000:1 and variable Current inputs Number of inputs 4 (3 phases + neutral) Type Clamp on current transformer with mv output Range 1 to 400 Arms with included clamps (I400S) 0.1 to 3000 Arms with optional clamps Input impedance 50 kω Bandwidth 9 khz Scaling 0.1, 1, 10, 100, 1000 mv/a and variable Nominal frequency 40 to 70 Hz Sampling system Resolution 16 bit analog to digital converter on 8 channels Maximum sampling speed 200 ks/s on each channel simultaneously RMS sampling 5000 samples on 10/12 2 cycles according IEC 61000-4-30 PLL synchronization 4096 samples on 10/12 2 cycles according IEC 61000-4-7 Display modes Waveform display Phasor Matrix readings AutoTrend graph Bargraph Eventlist Measurement modes Scope Available in Scope and Transient mode Captures 8 waveforms simultaneously Display update rate 5 x per second Up to 10/12 times horizontal zoom 2 Cursors: Single vertical line showing min, max, avg reading at cursor position Shows real time phasor diagram Available in Scope and Unbalance mode Display update rate 5 x per second Available in Volts/Amps/Hertz, Harmonics, Power & Energy, Flicker and Unbalance mode Available in Volts/Amps/Hertz, Dips & Swells, Harmonics, Power & Energy, Flicker, Unbalance, Inrush and Monitor mode Cursors: single vertical line showing with min, max, avg reading at cursor position Available in Harmonics and Monitor mode Available in Dips & Swells and Monitor mode Vrms, Arms, Vcursor, Acursor, Vfund, Afund, Hz, V phase angles, A phase angles Volts/Amps/Hertz Vrms, Vpk, V Crest Factor, Arms, Apk, A Crest Factor, Hz Dips and Swells Vrms 1 2, Arms 1 2 Captures up to 1000 events with date, time, duration, magnitude and phase identification with programmable thresholds Harmonics DC, 1 to 50 Harmonic Volts, THD Volt, Harmonic Amps, THD Amps, K Amps, Harmonic Watts, THD Watts, K Watts, Interharmonic Volts 4, Interharmonic Amps 4 (relative to fundamental or to total rms) Power and Energy 4 Watts, VA, VAR, Power factor, Cos ϕ / DPF, Arms, Vrms, kwh, kvah, KVARh, peak demand interval using trend, KYZ revenue meter verification via optional input Flicker Pst( 1min ), Pst, Plt, PF5, Vrms 1 2, Arms 1 2, Dc, Dmax, TDEX Unbalance Vneg, Vzero, Aneg, Azero, Vfund, Afund, Hz, V phase angles, A phase angles Transients 4 Vrms, Arms, Vcursor, Acursor Inrush Currents 4 Inrush Current, Inrush duration, Arms 1 2, Vrms 1 2 System Monitor Vrms, Arms, Harmonic Volts, THD Volts, Plt, Vrms 1 2, Arms 1 2, Vneg, Hz, dips and swells, unbalance. All parameters are measured simultaneously in accordance with EN50160. Using Flagging to indicate unreliable readings according IEC61000-4-30. 4 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers

Specifications continued Accuracy, resolution and range Volt/Amps/Hertz Measurement range Resolution Accuracy Vrms (AC+DC) 1 to 1000 Vrms 0.1 Vrms ± 0.5 % of nominal voltage Vpk 1 to 1400 Vpk 1 V 5 % of nominal voltage CFV 1.0 to > 2.8 0.1 ± 5 % Arms (AC+DC) 0 to 20,000 Arms 1 0,001 to 10 Arms 1 ± 1 % of reading ± 5 counts 3 with included clamps 0 to 400 Arms 0.1 and 1 Arms Apk using 1mV/A scaling 0-5500 Apk 10 A ± 5 % CFA using 1mV/A scaling 1 to 10 0.1 ± 5 % 50 Hz nominal 42.50 to 57.50 Hz 0.01 Hz ± 0.1 % of nominal frequency 60 Hz nominal 51.00 to 69.00 Hz 0.01 Hz ± 0.1 % of nominal frequency Dips and swells Vrms 1 2 (AC+DC) 0.0 to100 % of nominal voltage 0.1Vrms ± 1 % of nominal voltage Arms 1 2 (AC+DC) 0 to 20,000 Arms 1 0,001 Arms to 10 Arms ± 1 % of reading ± 5 counts 3 with included clamps 0 to 400 Arms 0.1 Arms and 1 Arms Threshold levels Programmable in percent of nominal voltage Duration hhh,mm,ss,mmm with half-cycle cycle time resolution Harmonics Harmonic selection (n) DC, 1 to 50 Inter-Harmonic selection Off, 1 to 49 Vrms Relative (%f): 0.0 to 100.0 % 0.1 % ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) Absolute: 0.0 to 1000 Vrms 0.1 Vrms ± 5 % of reading ± 2 counts Arms Relative (%f): 0.0 to 100.0 % 0.1 % ± 0.1 % ± n x 0.1 % (± 0.4 % for %r) Absolute: 0.0 to 4000 mv x selected 1 mvrms x selected clamp scaling ± 5 % of reading ± 5 counts clamp scaling Watts Relative: 0.0 to 100.0 % 0.1 % ± n x 2 % Absolute: depends on selected clamp ± 5 % of reading ± n x 2 % and voltage scaling of reading, ± 10 counts DC voltage Relative: 0.0 to 100.0 % 0.1 % ± 1 % Absolute: 0.0 to 1000 V 0.1 V ± 5 % of reading ± 10 counts THD 0.0 to 100.0 % 0.1 % ± 2.5 % Hz 0 to 3500 Hz 1 Hz ± 1Hz Phase angle -360 º to +360 º 1 º ± n x 1.5 º Power and Energy Watt 1.0 W to 20.00 MW 1 0.1 W to 1 kw 1 ± 1.5 % of reading ± 10 counts 3 VA 1.0 VA to 20.00 MVA 1 0.1 VA to 1 kva 1 ± 1.5 % of reading ± 10 counts 3 VAR 1.0 VAR to 20.00 MVAR 1 0.1 VAR to 1 kvar 1 ± 1.5 % of reading ± 10 counts 3 kwh 00.00 kwhr to 200.0 GWhr 1 0.01 Whr to 100 Whr 1 ± 1.5 % of reading ± 10 counts 3 kva 00.00 kvahr to 200.0 GVAhr 1 0.01 VAhr to 100 VAhr 1 ± 1.5 % of reading ± 10 counts 3 kvar 00.00 kvarhr to 200.0 GVARhr 1 0.01 VARhr to 100 VARhr 1 ± 1.5 % of reading ± 10 counts 3 Power Factor 0 to 1 0.01 ± 0.03 3 Cos ϕ / DPF 0 to 1 0.01 ± 0.03 3 Flicker Pst (1min), Pst, Plt, PF5 0.00 to 20.00 0.01 Within ± 5 % of tabulated values instantenous Flicker according IEC61000-4-15 Dc %, Dmax % and Time d(t) 0.0 to ± 100.0 % for Dc % and 0.1 % for Dc % and Dmax % and ± 1% for Dc % and Dmax % and exceeds limits. As described Dmax % and 0.000 to 9.999s 10 ms for Time 20 ms for Time per IEC 61000-3-3 for Time Unbalance Volts 0.0 to 5.0 % 0.1 % ± 0.5 % Current 0.0 to 20 % 0.1 % ± 1 % Transient capture Volts ± 6000 Vpk 1 V ± 15 % of cursor reading ± 2.5 % of Vrms Minimum detect duration 5 µs Sampling rate 200 ks/s Inrush mode Arms (AC+DC) 0.000 to 20.00 karms 1 0.001 to 10 Arms 1 ± 1 % of meas ± 5 counts 3 Inrush Duration mm:ss:mmm between 7.5 s to 10 ms ± 20 ms (Fnominal = 50 Hz) 30 m selectable Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 5

Specifications continued Trend recording Method AutoTrend automatically records min, max and average values over time for all readings being displayed for the 3 phases and neutral simultaneously Volts/amps/hertz, harmonics, power and energy, flicker and unbalance mode Sampling Recording time Zoom Dips and swells mode Sampling Recording time Zoom Inrush currents and flicker PF5 mode Sampling Recording time Zoom Monitor mode Sampling Recording time Limits Measurement method Vrms, Arms Vpeak, Apeak V Crest Factor A Crest Factor Hz Vrms 1 2, Arms 1 2 Harmonics Watt VA VAR Power Factor Cos ϕ / DPF Unbalance Flicker Transient capture Inrush current 5 readings/sec continuous sampling per channel 1800 min, max and avg points for each reading From 30 min with 1 second display resolution up to 450 days with 6 hour display resolution Up to 6 x horizontal zoom 100/120 2 readings/sec continuous sampling per channel 3600 min, max and avg points for each reading From 90 sec with 25 msec display resolution up to 450 days with 3 hour display resolution Up to 12 x horizontal zoom 100/120 2 readings/sec continuous sampling per channel 3600 min, max and avg points for each reading From 7.5 sec with 25 msec display resolution up to 30 min with 500 msec display resolution for Inrush measurements and up to 2.5 hour with 2.5 sec display resolution for PF5 recordings Up to 12 x horizontal zoom Combination of 5 readings/sec and 100/120 2 readings/sec continuous sampling per channel depending on the parameter measured Up to 1 week with 10 min resoluton 1008 min, max and avg points for each reading According EN50160 or customer definable 10/12 2 cycle contiguous non overlapping intervals using 500/416 2 samples per cycle in accordance with IEC 61000-4-30 Absolute highest sample value within 10/12 2 cycle interval with 40 µs sample resolution Measures ratio between the Vpeak and Vrms Measures ratio between the Apeak and Arms Measured every 10 sec in accordance with IEC61000-4-30 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle. This technique is independent for each channel in accordance with IEC 61000-4-30. Calculated from 10/12-cycle gapless harmonic group measurements on Voltage and Amps according to IEC 61000-4-7 Selectable Total or Fundamental real power display Calculates average value of instantaneous power over 10/12 cycle period for each phase Total Active Power P T =P 1 + P 2 + P 3 Selectable Total or Fundamental apparent power display Calculates apparent power using Vrms x Arms value over 10/12 cycle period Total Apparent Power is root mean square of real and apparent power Selectable Total of Fundamental reactive power display Calculates reactive power as root of VA squared minus Watt squared over 10/12 cycle period Capacitive and inductive load is indicated with capacitor and inductor icons Calculated Watt / VA Cos of angle between fundamental voltage and current The supply voltage unbalance is evaluated using the method of symmetrical components according to IEC61000-4-30 According to IEC 61000-4-15 Flickermeter - Functional and design specification Includes 230 V 50 Hz lamp and 120 V 60 Hz lamp models Captures waveform triggered on signal envelope Additionally triggers on dips, swells, interruptions and Amps level as specified by IEC61000-4-30 The inrush current begins when the Arms half cycle rises above the inrush threshold, and ends when the Arms half cycle rms is equal to or below the inrush threshold minus a user-selected hysteresis value. The measurement is the square root of the mean of the squared Arms half cycle values measured during the inrush duration. Each half-cycle interval is contiguous and non-overlapping as recommended by IEC 61000-4-30. Markers indicate inrush duration. Cursors allow measurement of peak Arms half cycle. 6 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers

Specifications continued General Case Design Drip and dust proof Rugged, shock proof with integrated protective holster IP51 according to IEC60529 when used in tilt stand position Shock and Vibration Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2 Display Type Bright Full-Color LCD with CCFL backlight, 80cd/m 2 Size Resolution Contrast and brightness 115.2 x 86.4 mm (4.5 x 3.4 in) 320 x 240 pixels User adjustable, temperature compensated Screens 50 screen memories on Fluke 434 25 screen memories on Fluke 433 Data 10 data memories for storing data including recordings on Fluke 434 5 data memories for storing data including recordings on Fluke 433 Limit templates 2 preprogrammed, 2 administrator (programmable via FlukeView, 2 user locations) Real-time clock Time and date stamp for AutoTrend, Transient display and SystemMonitor Mechanical Size 256 x 169 x 64 mm (10 x 6.6 x 2.5 in.) Weight 2 kg (4.4 lb.) Power Line power Switchable 115 V, 230 V adapter with country specific plug Battery power Battery operating time Battery charging time Power saving Standards Measurement methods used Power Quality Rechargeable NiMH (installed) > 7 hours 4 hours Adjustable time for dimmed backlight with on screen power indicator IEC61000-4-30 class A EN50160 Flicker IEC 61000-4-15 Harmonics IEC 61000-4-7 Safety Compliance IEC/EN61010-1 (2nd edition) pollution degree 2; CAN/CSA C22.2 No 101.1; ANSI/ISA S82.01 Max voltage on banana input Max voltage on current BNC input Environmental Operating temperature Storage temperature Humidity Maximum operating altitude Maximum storage altitude Warranty Accessories Included CAT III 1000 V / CAT IV 600 V 42 Vpeak 0 C to +50 C (32 F to 122 F) -20 C to +60 C (-4 F to 140 F) 10 to 30 C: 95 % RH non condensing (50 to 86 F: 95 % RH non condensing) 30 to 40 C: 75 % RH non condensing (86 to 104 F: 75 % RH non condensing) 40 to 50 C: 45 % RH non condensing (104 to 122 F: 45 % RH non condensing) 3000 m (9842 ft) Derate to CAT II 1000 V / CAT III 600 V / CAT IV 300 V above 2000 m (6561 ft) 12 km (39,372 ft) 3 years on mainframe, 1 year on included accessories Hard carrying case with clamp holders BC430 4 current clamps, i400s 5 Test leads, 4 black, 1 green 5 Alligator clips, 4 black, 1 green Battery Charger Eliminator, BC430 FlukeView Software, SW43W (Fluke 434 only) Optical Cable for USB, OC4USB (Fluke 434 only) Color localization set, WC100 Getting Started (printed) User Manual (CD-ROM) 1 depending clamp scaling 2 50 Hz/60 Hz nominal frequency according to IEC 61000-4-30 3 Add clamp accuracy 4 The advanced functions: interharmonics, energy, transients and inrush are optional for the Fluke 433 and standard available on the Fluke 434 Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 7

Optional 430 Series Accessories i400s AC Current Clamp Replacement current clamp for the Fluke 430 Series: It is compatible with any oscilloscope, ScopeMeter Test Tool or Power Quality Analyzer that accepts BNC connectors and is capable of millivolt measurements. TLS430 Test Lead Set Test lead replacement set for the 430 Series Power Quality Analyzer. Set includes five test leads and five alligator clips. WC100 Multi-Color Wire Clips 32 wire clips in 8 colors easily snap onto test leads and current clamp cables to organize multiple leads and cables in a work area. CCS430 Color coding set for Fluke 430 Series. C430 Hard carrying case. OC4USB Optical cable for USB. BC430 Battery charger 230 V/110 V. Fluke-433/UGK Upgrade kit for Fluke 433, includes FlukeView software, USB cable and advanced feature upgrade. Ordering information Model Fluke-433 Three-Phase Power Quality Analyzer Fluke-434 Three-Phase Power Quality Analyzer Fluke-433UGK Upgrade Kit for Fluke 433 Fluke offers a full suite of power quality test tools to locate, predict, prevent and troubleshoot power problems. Handheld troubleshooters for instant analysis Ready-to-use event loggers Full Disclosure power analyzers Power calibrators and standards backed by Fluke metrology expertise The Fluke power quality set of products offers the highest level of performance and maintains the Fluke promise of rugged and reliable test tools. 8 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ 2004 Fluke Corporation. All rights reserved. All copyrights are the property of their respective owners. Printed in U.S.A. 9/2004 2276752 D-US-N Rev A