Quality Assurance Implementation at the Roberts Proton Therapy Center. James McDonough 3 August 2013

Similar documents
Implementing a Proton Beam Scanning System within an Operating Clinical Facility

Promises and Perils of Proton Therapy Beam Delivery (Implications) or Towards Cost Effective Particle Therapy

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

G. Pittá(*), S. Braccini TERA Foundation, Novara, Italy (*) Corresponding author.

Development of New Carbon Therapy Facility and Future Plan of HIMAC

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

A NOVEL GANTRY FOR PROTON THERAPY AT THE PAUL SCHERRER INSTITUTE

Madero Ote. 686, Centro Histórico, C.P Morelia, Michoacán México. #300, Col. Cuauhtémoc, C.P Morelia, Michoacán, México

A Comparison of DPM and VMC++ Mont Carlo codes applied to heterogeneous media

PBS Products from Pyramid

Request for Proposals

III. Proton-therapytherapy. Rome SB - 3/5 1

Classic. Best Practice QA Solutions for All Rotational Therapies & IMRT For International Use Only. Classic. RIT113 Technical Specifications

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

LIGHT PROTON THERAPY PROJECT

Scope: All CT staff technologist

Equipment Quality Control for Digital Radiography February 22, Imaging Physics CancerCare Manitoba

National Institute of Radiological Sciences. Naoya Saotome

QUALITY CONTROL AND PATIENT DOSES FROM X-RAY EXAMINATIONS IN SOME HOSPITALS IN THAILAND

Published text: Institute of Cancer Research Repository Please direct all s to:

FFDM Quality Control in Canada - a Vendor Neutral Approach

Dental Line. High frequency intraoral x-ray unit. radiology ahead

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

2017 Computed Tomography

2012 Computed Tomography

Standard. Substitute Test or Procedure. Required Test or. 1 Scan Increment Accuracy. Initially and Annually Initially and Annually

SPEAR 3: Operations Update and Impact of Top-Off Injection

Recent developments in cyclotrons for proton therapy at IBA

FDA MAMMOSCAN FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM MAMMOGRAPHY

-Technical Specifications-

RSNA 2006 November 26 to December 1 Chicago. Guest author for ImPACT Dr. Koos Geleijns, Medical Physicist, Leiden University Medical Center.

DICOM Correction Proposal

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Transfer Radiation Thermometer With Temperature Range Of 0 C To 3,000 C

Status of GEM-based Digital Hadron Calorimetry

Particle Beam Production - A Synchrotron-Based System - Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

Mechanical aspects, FEA validation and geometry optimization

World First Slim Cassette Type Digital Mammo. Upgrade Solution

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

The trigger for the New Electromagnetic Calorimeter NewCal

2

Proton Engineering Frontier Project

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Therapy Control and Patient Safety for Proton Therapy

The PEFP 20-MeV Proton Linear Accelerator

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Technologist Quality Control Procedures

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

Beam Loss Detection for MPS at FRIB

What to consider when choosing a mammography display

IMPAC Infrared Thermometers

Practix. Mobile Radiography. All a Bucky station needs plus mobility. Practix 400

Standard Operating Procedure of nanoir2-s

Optical Link Layout Options

Mahdad Manavi LOTS Technology, Inc.

Undulator Protection for FLASH and for the European XFEL

Beam Commissioning of GRIFFIN Beam Line

The FAIR plinac RF Systems

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

MultiFlex An Innovative I 2 PL Device and an Outstanding Nd:YAG Laser in One Versatile Platform

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

arxiv: v1 [physics.ins-det] 1 Nov 2015

Collimation and Light Field Brightness

Staff dose and good prac/ces in CT guided IR procedures. Jonas Andersson Medical Physicist, Ph.D.

Data Collection Using APEX3. March 30, Chemical Crystallography Laboratory

Connection for filtered air

THE THERAC-25 ACCIDENTS

HELICAL SCAN TECHNOLOGY: ADVANCEMENT BY DESIGN

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

IAEA RER/9/135 COURSE ON OPTIMIZATION IN COMPUTED TOMOGRAPHY Sofia, Bulgaria, Tube current modulation and dose reduction : How TCM works

HAPD and Electronics Updates

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Lensed Fibers & Tapered Ends Description:

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Intuitive Workflow by Barco. Designed for the way you work, naturally.

UArm. Series. Analog or Digital U-Arm System

Checking the fluids of the cart

LUMIGEN INSTRUMENT CENTER X-RAY CRYSTALLOGRAPHIC LABORATORY: WAYNE STATE UNIVERSITY

Development of Continuous Line Scanning System Prototype for Proton Beam Therapy

Overview of NIRS Accelerator Activity

Coronis 5MP Mammo. The standard of care for digital mammography

SYNCHRO REPLA:Y SYNCHRO REPLA:Y. NEW: ALEX at 3 Hz! MEDICINE AND AESTHETICS. The First Alexandrite Laser Working at 3 Hz

Signage for Bus Stop and Airport

Coronis Uniti (MDMC-12133) 12MP diagnostic display system for PACS and breast imaging

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

ISOMET. Compensation look-up-table (LUT) and Scan Uniformity

THE IBA SUPERCONDUCTING SYNCHROCYCLOTRON PROJECT S2C2

PATIENT POSITION IMAGING PARAMETERS

Physics Requirements for the CXI Ion Time-of-Flight

AAMD Writing Competition Guidelines for Submission

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

Product Data Sheet 4656 EZ

Assessment of the Impact of Dark Signal on Image Quality in Computerized Mammography. Introduction

Transcription:

Quality Assurance Implementation at the Roberts Proton Therapy Center James McDonough 3 August 2013 1

Roberts Proton Therapy Center Machine configuration and layout 4 gantries, 1 fixed beam line, 1 research room Delivery systems Fixed beam room has a dedicated PBS nozzle 1 gantry currently using DS & US; will be commissioned for PBS 1 gantry currently using PBS; previously treated with US 2 gantries treating with DS; will likely stay that way 5 linacs, 2 CT-Sims, 1 PET-CT-Sim, 1 MRI plus treatment planning & exam rooms in adjacent space on same floor as the proton center (total is approximately 80,000 square feet) The Abramson Cancer Center occupies ~200,000 square feet on the floors above where radiation oncologists see their new consult and follow up patients 2

Roberts Proton Therapy Center ~100 patients treated per day (in ~12 hrs) Typical patient mix 30% prostate, prostate bed, prostate whole pelvis 20% GI 15% lung 15% CNS 10% H&N 10% other (sarcoma, Gyn, breast, ) ~15% Pediatric ~10% re-irradiation 3

Roberts Proton Therapy Center Staffing ~10 FTE physicists (~25 physicists in department) 3 MMP students help with morning QA ~20 therapists (~55 in whole clinic) 10 treatment planners (includes 2 physicists) ~15 FTE clinical MDs in proton + linac 4

Daily Machine QA 1 physicist + 2-3 medical physics students perform QA All rooms: Align MatrixX using x-ray system & check lasers; perform safety checks (door, lights, video/intercom, radiation detector, pause) For DS & US rooms: two beams measure output (constancy 3%), flatness (2%)& symmetry(3%), and range (3 mm) using IBA Faraday detector in the Y-jaw). For PBS rooms: three beams one for range (dose within 20% on falling edge) & two for output (2%), flatness & symmetry (2%), and field size (2 mm). In the room that has a range shifter one of the fields will use that. If all goes well rooms with DS take 15-20 minutes; the rooms with PBS take 20-30 minutes and the room with both US&DS takes 20-30 minutes. 5

Weekly/Monthly QA No weekly QA Monthly QA Mechanical tests for gantry, collimator, couch angles X-ray vs proton alignment at 4 gantry & 2 collimator (DS/US) angles, 3 field sizes; x-ray vs compensator alignment (DS/US) DS Range/Modulation (Zebra or water tank), output (PPC05) for 5 fields; US R/M for 4 fields & output for 7 fields PBS test pattern (5 energies, 3 gantry angles), spot spacing (4 fields covering full 34 x 25 cm 2 ), R/M & output for 3 fields Takes 2-3 hours per room Equipment used: PPC05, LynX, MatrixX, Zebra, sometimes Blue Phantom 6

Test Pattern 7

Annual QA Standard monthly measurements TRS-398 using FC-65 for R15M10 and R25M10 Check Matrix & PPC05 calibrations Star shots for couch, gantry and (for DS/US) collimator PDDs to get range and modulation for 7 beams (DS); 4 beams (US); & 3 beams (PBS) Field size measurements (3 fields) for DS/US ball test for PBS to check alignment of x-ray and proton Dose/MU linearity RPC TLDs 8

Patient Specific QA DS Use MatrixX to measure the output of each field at mid-sobp to determine MUs. We compare this to a model based on the MGH model. Also verify compensators using a depth gauge. We use the measurement for the MUs but if it differs from the model by >3% we investigate by running standard fields to see if something has changed. Takes ~15 minutes to prepare the validation plan + ~30 minutes to set up and run the fields. Another physicist enters the MUs as part of the initial check. US Same as DS except we also measure range & modulation with Zebra. Tolerance on range is 2 mm; modulation is 88-92%.Takes an extra 30 minutes. PBS Use MatrixX to measure 3 depths proximal, mid-sobp, and distal. Use gamma analysis (>90% pass 3% & 3 mm) to compare to Eclipse. If mid- SOBP output is 5-10% off we renormalize the plan. If <3% off we do nothing; for 3-5% we evaluate plan to decide whether to normalize. Takes 30-45 minutes to prepare validation and export planes; another 30-60 minutes to deliver each field three times; and another 30 minutes for the analysis. 9

Unique Implementations MLC (For DS & US) + Very helpful when feathering + Therapists are happy not dealing with apertures - Sometimes causes large air gaps - Limits DS & US field size (24 cm x 18 cm) - Limits PBS field size (34 cm x 25 cm) - Snout cannot translate in PBS mode Range-shifter close to the patient (PBS) Minimum range out of the nozzle is 7.5 cm so a range-shifter is needed but we cannot move our snout. To minimize the spot size we have made several versions of range-shifters mounted on, or built into, the couch. 10

Top 3 wish list items 1. Better treatment planning (Eclipse) especially dealing with heterogeneities and range uncertainties tools to make optimization easier (e.g., tapering dose at matched PBS fields) faster PBS optimization 2. Better interface between Aria & IBA We essentially have no R&V system neither side pays any attention to daily, session, or total dose limits We have huge issues with Aria containing the right information about fractions delivered, dose delivered, & even planned dose We still cannot get our imaging into off-line review in a smooth way 3. Faster beam delivery (IBA) better room switching time currently ~35 sec; want ~15 sec better layer switching time (PBS) currently 5-6 seconds; want 2-3 seconds. 4 & 5 - Verification of range in patient & a 3-D dosimeter 11

12