Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Similar documents
Advances in multi-pixel Geiger mode APDs (Silicon Photomultipliers).

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Production and Development status of MPPC

Solid State Photon-Counters

A new Scintillating Fibre Tracker for LHCb experiment

SciFi A Large Scintillating Fibre Tracker for LHCb

Beam test of the QMB6 calibration board and HBU0 prototype

CMS Upgrade Activities

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Sensors for the CMS High Granularity Calorimeter

Sensors for precision timing HEP

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

A very brief review of recent SiPM developments

CAEN Tools for Discovery

Silicon PhotoMultiplier Kits

Application of Hamamatsu MPPC to T2K near neutrino detectors

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

An extreme high resolution Timing Counter for the MEG Upgrade

HAPD and Electronics Updates

Perugia 16 June 2009 Flavio Dal Corso INFN-Padova 1

MPPC and MPPC module for precision measurement

Drift Tubes as Muon Detectors for ILC

Development of an Abort Gap Monitor for High-Energy Proton Rings *

Current status of Hamamatsu Si detectors mainly for High Energy Physics Experiments

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

PoS(PhotoDet 2012)018

An extreme high resolution Timing Counter for the MEG experiment Upgrade

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

The CALICE test beam programme

Front End Electronics

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

arxiv: v1 [physics.ins-det] 1 Nov 2015

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

MPPC (multi-pixel photon counter)

Tests of Timing Properties of Silicon Photomultipliers

Investigation of Avalanche Photodiodes for EM Calorimeter at LHC. LPNHE, Ecole Polytechnique, F Palaiseau, FRANCE. B. Ille, D.

SciFi A large Scintillating Fibre Tracker for LHCb

News in Photodetectors

Front End Electronics

A TARGET-based camera for CTA

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

A Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout

TORCH a large-area detector for high resolution time-of-flight

Monolithic Thin Pixel Upgrade Testing Update. Gary S. Varner, Marlon Barbero and Fang Fang UH Belle Meeting, April 16 th 2004

HARDROC, Readout chip of the Digital Hadronic Calorimeter of ILC

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

Optical Link Layout Options

The CMS Detector Status and Prospects

Advanced Sensor Technologies

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

The hybrid photon detectors for the LHCb-RICH counters

Photonic Devices for Vehicle Evolution

Versatile Link. Radiation Qualification

Status of GEM-based Digital Hadron Calorimetry

High ResolutionCross Strip Anodes for Photon Counting detectors

Double Screening Tests of the CMS ECAL Avalanche Photodiodes

Status of the Timing Detector Plastic+SiPM Readout Option

Neutron Irradiation Tests of an S-LINK-over-G-link System

The Status of the ATLAS Inner Detector

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

with Low Cost and Low Material Budget

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

DAQ Systems in Hall A

arxiv: v1 [physics.ins-det] 2 Dec 2008

The ATLAS Pixel Detector

Present Status and Future Upgrade of KEKB Injector Linac

Diamond detectors in the CMS BCM1F

NMOS linear image sensor

Digital BPMs and Orbit Feedback Systems

MPPC modules. MPPC array modules for very-low-level light detection, 16 ch analog output. C13368/C13369 series (Analog output type)

MCP Upgrade: Transmission Line and Pore Importance

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note

THE ATLAS Inner Detector [2] is designed for precision

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Performance of the MCP-PMT for the Belle II TOP counter

Radiation-Hard Optical Link for SLHC

Review of High Quantum Efficiency Large Area Photomultiplier Tubes

A pixel chip for tracking in ALICE and particle identification in LHCb

Linac 4 Instrumentation K.Hanke CERN

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

Design Studies For The LCLS 120 Hz RF Gun Injector

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

VTA0832H Series Linear Photodiode Array (PDA) for X-ray Scanning

Position Resolution of Optical Fibre-Based Beam Loss Monitors using long electron pulses

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

Transcription:

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade Yuri Musienko* FNAL(USA) Arjan Heering University of Notre Dame (USA) For the CMS HCAL group *On leave from INR(Moscow) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 1

Outline CMS HCAL and motivation for its Upgrade HB&HE upgrade challenges Status of photo-sensor development for the HB&HE upgrade R&D plans for 2011-2012 NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 2

CMS HCAL HF HO HB HE HPD HB, HE, HO similar technology: scintillator tiles with Y11 WLS fiber readout, brass (steel for HO) absorber. 19 ch. HPD was selected as the CMS HCAL photodetector. NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 3

Motivation for the HB/HE photo-detector upgrade 1. G-APDs/SiPMs have better quantum efficiency, higher gain, and better immunity to magnetic fields than HPDs. Since SiPMs operate at relatively low voltages, they do not produce large pulses from high voltage breakdown that mimic energetic showers like HPDs do. These features of the SiPMs together with their low cost and compact size compared to HPDs enable several major changes to the HCAL. 2. Implementation of depth segmentation which has advantages in coping with higher luminosities and compensating for radiation damage to the scintillators. This is made possible by the use of SiPMs. 3. Use of timing to clean up backgrounds, made possible by the extra gain and better signal-to-noise of the SiPMs. Status of the HO calorimeter upgrade is discussed in the NDIP- 2011 poster (ID-101): J.Freeman Progress on the SIPM Upgrade of the CMS Outer Hadron Calorimeter (HO) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 4

Longitudinal segmentation of the CMS HCAL NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 5

Segmentation schemes Color code represents the layers that are grouped into separate readout channels. The left scheme maximizes resolution by concentrating separate readout channels to groups of layers where the energy density is highest. The right scheme maximizes redundancy and robustness of the calorimeter by providing two rear readout channels with interleaving sampling of the hadronic showers. NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 6

EDU vs. ODU concepts 18x1 mm 2 G-APD array 8x4.84 mm 2 G-APD array NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 7

The most important HB/HE G-APD/SiPM requirements High PDE(515 nm): 15-30% Number of pixels (effective pixels): >15 000 1/mm 2 Fast pixel recovery time: 5 100 ns (depends on the pixel density) Good radiation hardness > 3*10 12 n/cm 2 (10 years of SLHC) - Gain*PDE change < 20% - noise < 1 MIP at 50 ns integration time Low optical cross-talk between cells <10% Low sensitivity to neutrons < 10-5 1/n at 30 p.e. threshold? Low temperature coefficient < 5%/C High reliability NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 8

HB/HE photo-sensor candidates (end of 2008) MPPC S10362-050 (Hamamatsu) - PDE(515nm)=25-30 %; Gain~7*10 5 - X-talk =10-15% - dynamic range: 400 cells/mm 2 (1936 cell (for 4.84 mm 2 ) << 25 000) - cell recovery time: τ~ 15-20 нсек MPPC S10362-025 (Hamamatsu) -PDE(515nm)~20 %; Gain~2.5*10 5 - X-talk <15% - dynamic range: 1600 cells/mm 2 (7744 cell (for 4.84 mm 2 ) << 25 000) - cell recovery time: τ~ 6 нсек MAPD-A (Zecotek, Singapore): - PDE(515нм)~14%; Gain~5*10 4 - X-talk <15% - dynamic range: 15 000 cells/mm 2 (72 600 cells (for 4.84 mm 2 )) - cell recovery time (95%): ~300 µs >> 1 µs MAPD-A (Zecotek, Singapore): - PDE(515нм)~12%; Gain~2*10 4 - X-talk <15% - dynamic range: 40 000 cells/mm 2 (193 600 cells (for 4.84 mm 2 )) - cell recovery time (95%): ~300 µs >> 1 µs We also studied devices from : FBK, CPTA, ST-Micro, Sens-L But all these SiPMs had low cell density <1000 cells/mm 2 NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 9

New candidate from Zecotek: MAPD-3N (2009) Schematic structure (a) and zone diagram Micro-pixel APD (MAPD) (b) of a (Z. Sadygov et al, arxiv;1001.3050) MAPD cell recovery Measured using double LED pulse method MAPD cell schematics This structure doesn t contain quenching resistors. Specially designed potential barriers are used to quench the avalanches. NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 10

MAPD-N linearity (Z. Sadygov et al, arxiv;1001.3050) Dependence of the MAPD (135 000 cells, 3x3 mm 2 area) signal amplitude A (in relative units) on the number of incident photons N NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 11

2009 prototype module We decided to perform BT-2009 to understand challenges using G-APDs in HCAL. Separate read-out of HCAL layers (1-2-2-12 segmentation) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 12

CERN H2 TB-2009 setup NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 13

TB-2009 with 15K/mm 2 MAPDs NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 14

Challenges using G-APD in HCAL Our candidates didn t complelly satisfy the requirements of the CMS HB/HE upgrade R&D to develop G-APD for HB/HE started in 2009 NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 15

R&D goals for Zecotek Zecotek can produce MAPDs with >15 000 cells/mm 2 keeping high PDE >25% at the same time. However the existing MAPDs have slow cell recovery time (~300 µs for 95% recovery). It has to be reduced a factor of ~100 to satisfy the CMS HCAL upgrade requirements. We set the following main R&D goals for Zecotek - PDE(515nm): >20 %; - number of cells: ~27 000/mm 2 (MAPD-EDU concept), 50-70K cells for 2.2x2.2 mm 2 MAPD- ODU solution - cell recovery time (95% cell recovery): ~ 1-10 µs - gain ~30 000 60 000 - optical cross-talk: <10% - radiation hardness: up to ~10 13 n/cm 2 - low sensitivity to neutrons: 10-5 1/n at 1 MIP threshold (?) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 16

R&D goals for Hamamatsu Hamamatsu can t produce MPPCs with >5 000 cells/mm 2 keeping high PDE >15% at the same time. However it can produce devices with very fast cell recovery time (<6 ns). The emission time of Y11 WLS is ~10 ns. MPPCs with fast cell recovery time <5 ns should have a factor 2-3 larger dynamic range in comparison to the MPPCs with slow cell recovery time. We set the following main R&D goals for Hamamatsu: - PDE(515nm)>15 %; - number of cells: 4 489 cells/mm 2 (or ~20 000 cells for 2.2x2.2 mm 2 MPPC-ODU solution) - cell recovery time: τ~ 5 ns (the maximum dynamic range of such MPPCs should be extended to ~11 000-12000 p.e/mm 2 ) - gain ~200 000 - optical cross-talk: <10% - radiation hardness: up to ~10 13 n/cm 2 - low sensitivity to neutrons: 10-5 1/n at 1 MIP threshold (?) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 17

MPPCs with increased dynamic range In June 2010 Hamamatsu developed for CMS new large dynamic range MPPCs Main MPPC parameters MPPCs photos taken using microscope NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 18

Linearity for Y11 and fast LED light (R q =1.67 MOhm, 15 µm MPPCs) Fast LED light: the MPPC with 4 500 cells is equivalent to a SiPM with 4 500 cells. Y11 light (emission time ~10 ns): the same MPPC works as a SiPM with 7 500 cells. Pixel recovery time constant: τ~11 ns. NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 19

Fast 15 µm MPPCs In March 2011 we received 3 new typs of 1 mm 2 MPPCs from Hamamatsu (free samples): - MPPC with R q =2 MOhm - MPPC with R q =500 kohm - MPPC with R q =370 kohm 15 µm cell pitch Such parameters of MPPCs as VB, Gain, Capacitance, Cell resistor, 35 ps laser response, PDE(515 nm) were measured at CERN APD Lab. Set-ups for cell recovery time and linearity measurements were improved (the LED was replaced with much faster and brighter one) Cell recovery was measured for new 15 mm cell pitch MPPCs (500k Ohm and 2 MOhm quenching resistors) MPPC linearity of 15 µm (500 kohm) for Y11 WLS light was measured NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 20

New 15 µm MPPCs parameters C cell ~8 ff, for R q ~500 kohm τ~4 ns NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 21

2 MOhm MPPC: 35 ps laser response 20 ns NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 22

500 kohm MPPC: 35 ps laser response 20 ns NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 23

Cell recovery studies with fast UV LED Measured using double LED pulse method NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 24

R q = 2MOhm cell recovery 99% cell recovery after ~60 ns NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 25

R q = 500 kohm cell recovery 99% cell recovery after ~15 ns. 2.3 ns pixel dead time? NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 26

Linearity for Y11 light (R q =500 kohm, 15 µm MPPCs) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 27

Performances of new Hamamatsu MPPCs new MPPCs (15 µm cell pitch, R q =500 kohm) have a factor of 2.7 increased dynamic range for Y11 light due to very fast cell recovery time (~4 ns) at 4V over-voltage they have: - Gain=2*10 5 - PDE(515 nm)~17 % - ENF~1.1 linearity for Y11 light of 4489 cells/mm 2 MPPC (R q =500 kohm) corresponds to a G-APD with ~12 000 cells/mm 2 NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 28

Neutron fluxes in CMS For 3000 fb -1 : RBX HO: ~1-2*10 11 1 MeV n/cm 2, RBX HB&HE: ~1-2*10 12 1 MeV n/cm 2 HB RBX HE RBX Calculated using MARS code (http://cmstrk.fnal.gov/radsim/nfluenceg.php) NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 29

Neutron irradiation tests We performed SiPMs radiation hardness tests using neutrons (Е~1 МеV) at CERN IRRAD-6 facility (see NDIP-2011 talk A. Heering et all. Radiation damage studies of silicon photomultipliers at SLHC at CERN PS ) G-APDs with high cell density and fast recovery time can operate up to 3*10 12 neutrons/cm 2 (gain change is< 25%). NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 30

Neutron signals in FBK, KETEK and Zecotek G-APDs NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 31

Neutron signals in Hamamtsu MPPCs NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 32

Third party vendors in the Game NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 33

Large dynamic range SiPMs with bulk integrated quenching resistors from NDL(Beijing) (see NDIP-2011 presentation of Han Dejun Progress on SiPM with bulk quenching resistor ) Schematic structure of the SiPM with bulk integrated resistors (S=0.5x0.5 mm 2, 10 000 cells/mm 2 ) SiPM non-linearity n on p (structure for green light) sensitive area - 0.25 мм 2 number of cells - 2 500 operating voltage- 26.5 V quenching resistor value - 200-300 ком NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 34

SiPM from KETEK (Germany) Sensitive area: 1 mm 2 Number of cells: 400 PDE(515 nm)~25 % Gain (dvb~4v): 5*10 6 Dark Count (0.5 ph.e.): ~1.5*10 6 Opt. cross-talk (dvb~4v): 10% NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 35

Specs for photo-sensors EDU ODU NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 36

Summary We are in the middle of the R&D stage to develop photo-sensors for the CMS HCAL Phase-I Upgrade. Significant progress on the development of large dynamic range, fast, radiation hard G-APD/SiPM photosensors was achieved over the last year. Currently we are working with 6 G-APD/SiPMs producers: Hamamatsu, Zecotek, CPTA, KETEK, FBK, NDL. We received very promising devices from Hamamatsu and Zecotek. New devices are expected from all the G-APD/SiPM producers at the end of this summer. In July and October we plan to have beam tests at CERN to check the EDU/ODE concepts. At the end of 2011 we expect to have at least one candidate which satisfy most of requirements of the CMS HCAL Phase-I Upgrade. We should select 1-2 producers to continue R&D in 2012 with the goal to improve parameters of the selected G-APDs-candidates and finally select the best photosensor for the CMS HB/HE Phase-I Upgrade. NDIP-2011, Lyon, 8.07.2011 Y. Musienko (Iouri.Musienko@cern.ch) 37